| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.9 L+₹2.7 L (18.8%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 3 | L3₹17.6 L+₹3.4 L (23.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THEN LOWEST BIDDER | |
| 4 | L4₹20.2 L+₹5.9 L (41.5%)Rejected-Finance 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | L4 | Rejected-Finance OTHER THEN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L2 | SB ENTERPRISES L4 | VIDHATA ELECTRICALS L3 | ANIKET TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Rubbing/ scratching complete old paint of 33/11KV power transformer of capacity 6.3 MVA, through cleaning with kerosene/thinner oil and providing two coats of metallic Grey paint including writing MES No on Transformer body with black paint complete all as specified and directed by Engr-in-Charge.. | 2 | Each Job | 5,000 ₹10,000 | 15,999 ₹31,998 | 7,000 ₹14,000 | 4,000 ₹8,000 Lowest |
| 2.00 | M&L for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed by Engr-in-Charge. | 20 | Cum | 1,200 ₹24,000 | 999 ₹19,980 | 800 ₹16,000 | 500 ₹10,000 Lowest |
| 3.00 | M&L for out door end temination kit of heats shrinkable suitable for 95 sqmm to 120 sqmm HT 3 core 11000 volts XLPE cable type complete all as specified and directed by Engr-in-Charge. | 2 | Each Job | 1,800 ₹3,600 Lowest | 1,999 ₹3,998 | 3,500 ₹7,000 | 2,500 ₹5,000 |
| 4.00 | M&L for complete servicing of VCB Capacity 400 to 600 Amps, 11 KV, 50 Hz, Model- JVAC No-Make : CG installed at 33 KV MRS by using required T & P including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments complete all as directed by Engr-in-Charge. The serviing covers the following :-
(a) Through cleaning of breaker chamber
(b) Lubrication of shutter mechanism/moving parts
(c) Checking of shutter movement
(d) Checking door interlocks with breaker
(e) Checking of breaker interlocks with panel door | 11 | Each Job | 7,000 ₹77,000 | 5,909 ₹64,999 | 3,000 ₹33,000 | 2,000 ₹22,000 Lowest |
| 5.00(f) Checking of breaker rack in/out inside the panel. (g) Coiling of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test/service Aux. switch operation (k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking of damping device and setting. (n) Tightness, checking of power connection. (o) Checking of breaker ON/OFF operation manually and electrically. (p) Checking of closing timings. Note : Spares shall be measured and paid sapartely under relevent items. | |||||||
| 5.01 | Supply only TNC Switch 25A IEC-60947-3, 11 KW - 12.8A. | 3 | Each | 2,000 ₹6,000 | 499 ₹1,497 Lowest | 1,350 ₹4,050 | 500 ₹1,500 |
| 5.02 | Supply only Push Button Emergency complete | 1 | Each | 850 ₹850 | 399 ₹399 | 540 ₹540 | 200 ₹200 Lowest |
| 5.03 | Supply only Push Button Assy. | 3 | Each | 900 ₹2,700 | 499 ₹1,497 | 450 ₹1,350 | 200 ₹600 Lowest |
| 5.04 | Supply only Tulip Contact. | 3 | Each | 800 ₹2,400 | 299 ₹897 | 400 ₹1,200 | 200 ₹600 Lowest |
| 5.05 | Supply only Racking operating Mechanism 12 KV 1250A 31.5KA. | 2 | Each | 2,000 ₹4,000 Lowest | 3,199 ₹6,398 | 8,500 ₹17,000 | 2,000 ₹4,000 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Jul 2025, 6:00 pmClosed
HQ CWE (AF) Jammu
HQ CWE (AF) Jammu AIR FORCE STATION JAMMU
CA NO CWEAFJ-13/2025-26 REPAIR AND MAINT OF 33KV POWER TRANSFORMER CONTROL PANELS BREAKERS AND ALLIED WORK OF 33 KV MAIN RECEIVING STATION AT AF STN JAMMU
2025_MES_717676_1
CA NO CWEAFJ-13/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAMMU
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF JAMMU
₹40,000
Yes
12 Dec 2025
30 Jun 2025
30 Jul 2025
30 Jun 2025
28 Jul 2025
14 Jul 2025
Amount
Rubbing/ scratching complete old paint of 33/11KV power transformer of capacity 6.3 MVA, through cleaning with kerosene/thinner oil and providing two coats of metallic Grey paint including writing MES No on Transformer body with black paint complete all as specified and directed by Engr-in-Charge..
M&L for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed by Engr-in-Charge.
M&L for out door end temination kit of heats shrinkable suitable for 95 sqmm to 120 sqmm HT 3 core 11000 volts XLPE cable type complete all as specified and directed by Engr-in-Charge.
M&L for complete servicing of VCB Capacity 400 to 600 Amps, 11 KV, 50 Hz, Model- JVAC No-Make : CG installed at 33 KV MRS by using required T & P including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments complete all as directed by Engr-in-Charge. The serviing covers the following :- (a) Through cleaning of breaker chamber (b) Lubrication of shutter mechanism/moving parts (c) Checking of shutter movement (d) Checking door interlocks with breaker (e) Checking of breaker interlocks with panel door
(f) Checking of breaker rack in/out inside the panel. (g) Coiling of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test/service Aux. switch operation (k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking of damping device and setting. (n) Tightness, checking of power connection. (o) Checking of breaker ON/OFF operation manually and electrically. (p) Checking of closing timings. Note : Spares shall be measured and paid sapartely under relevent items.
Supply only TNC Switch 25A IEC-60947-3, 11 KW - 12.8A.
Supply only Push Button Emergency complete
Supply only Push Button Assy.
Supply only Tulip Contact.
Supply only Racking operating Mechanism 12 KV 1250A 31.5KA.
Supply only Shunt Closing Release 24V.
Supply only Shunt Tripping Release 24V.
Supply only mechanical caupling with pins.
Supply only Door Handle JVAC.
Supply only Shroud Side JVAC.
Supply only 11 KV VCB Connection accessories 1250 Amps.
Supply only Window glass complete for door VCB.
Supply only Spring stored Energy Actuator FSA-1 Drive for Breaker.
Supply only Vaccum Interrupters Bottle 12 KV
Supply only PT HRC fuse 3.15 Amps for VCB 11 KV Incomer
Supply only Aluminium PG clamp size 4-6 Inch, thickness 5-10mm, full finish type polished at 33 KV Yard.
Supply only heavy duty (Suitable for HT ) aluminium thimble of size 120 to 240 sqmm
Note : The repaired breaker will be checked by the firm for the following :- (a) Through cleaning of breaker chamber (b) Lubrication of shutter mechanism / moving parts (c) Checking of shutter movement (d) Checking door interlocks with breaker (e) Checking of breaker interlocks with panel door (f) Checking of breaker rack in/out inside the Panel. (g) Coiling of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test / Service Aux. switch operation.
(k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking of VCB interapted value healthiness of all three poles. (n) Checking of damping device and setting. (o) Tightness, checking of power connection. (p) Checking of breaker ON/OFF operation manually and electrically. (q) Checking of closing timings. (r) Test result report also will be handover to Engr-in-Charge (s) The breaker shall be repaired through authorised dealer or representative of manufacturer only. Recommended authorised Rep by CG OEM or any other reputed firm recommended by manufacturer. (ii) The parts required will be measured and paid under relevant items of BOQ as above.
M & L for overhauling of 33 KV Outdoor VCB -04 Nos and Indoor C&R - 02 Nos Breaker Model : IEC-62271-100, making capacity-62.5, current capacity -1250 Amp, Closing Coil - 24 VDC including 33 KV Equipment and Control Panel - 02 Nos Make : CG after removing the old worn out spare parts and replacing with the same make, assembling, erecting, connecting, testing and commissioning complete with undermentioned scope of work :- (i) Removal /Isolation of live conductor from the breakers. (ii) Removal of pole column from structure. (iii) Inspections and aligments of mechanism for proper operations.
(k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking of VCB interapted value healthiness of all three poles. (n) Checking of damping device and setting. (o) Tightness, checking of power connection. (p) Checking of breaker ON/OFF operation manually and electrically. (q) Checking of closing timings. (r) Test result report also will be handover to Engr-in-Charge (s) The breaker shall be repaired through authorised dealer or representative of manufacturer only. Recommended authorised Rep by CG OEM or any other reputed firm recommended by manufacturer. (ii) The parts required will be measured and paid under relevant items of BOQ as above.
M & L for replacement of unserviceable Fixed Contact suitable for Isolator 36 KV nominal voltage 33 KV having copper (ETP) material including moving blade made of copper (ETP) 706 of existing sample or latest technology including replacement of steel screws and washers of required size and fixing in position complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old chain link fencing and applying two coats aluminium painting with angle complete all as specified and directed by Engr-in-Charge.
Disconnecting for servicing of the Power Transformer of capacity 6.3 MVA, 33/11 KV installed at 33 KV Main Receiving Station of GE (AF) Jammu from HV/LV transmission line, control cables, conservator, bushing connections for testting including checking of transformer oil upto desired level in suitable capacity including testing complete yard. The following test are will be consider during service of transformers and test result report also will be handover to JE E/M / Engr-in-Charge.
Note : The repaired breaker will be checked by the firm for the following :- (a) Through cleaning of breaker chamber (b) Lubrication of shutter mechanism / moving parts (c) Checking of shutter movement (d) Checking door interlocks with breaker (e) Checking of breaker interlocks with panel door (f) Checking of breaker rack in/out inside the Panel. (g) Coiling of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test / Service Aux. switch operation.
Supply and fixing toughened glass with Gasket suitable for 33/11KV 6.3 MVA Kirloskar transformer's temperature gauge chamber as per existing size complete all as specified and directed by Engr-in-Charge.
Oil testing of Power Transformer from Govt approved laboratory as per relevant IS given and submitting the test report thereof. (IS 1866-1983 for oil in service) (a) Electric strength (BDV) with 4 mm gap) (b) Water content. (c) Specific resistance (Resistivity) at 90 degree centigrade. (d) Di-electric decipation factor (tan delta) at 90 degree centigrade. (e) Neutralization value (total acidity) (f) Interfacial tension at 27 degree centigrade. (g) Flash point (h) Sediment and/or sludge.
M&L for heating, filtration and dehydration of Transformer Oil of 33/11 KV 6.3 MVA Power transformer as per IS : 10028 (Part-III) 1981 Para 5.2 dehydration/filtration plant to achieve dielectric strength of More than 60 KV at 4mm gap complete all as specified and as directed. Note : Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor at his own expenses to the entire satisfaction of the Engr-in-Charge.
(a) The cost of dehydration machine including T & P will be deemed to be included in the quoted rate. (b) The contractor will arange electric supply to run the dehydration machine and cost of the same will be deemed to be included in the quoted rate. (c) The contractor will give in writing in advance for Schedule of dehydration / repair of transformer in order to plan shut down. (d) The contractor will arrange labour, T & P and stores in a manner to restore the electric supply within stipulated time i.e maximum within 08 hours. (e) Dehydration and topping up of oil will be carried out in front of rep of deptt and necessary test report be submitted by the contractor.
Supply only new EHV, 60 KV grade Transformer Oil as per IS-335 for cleaning purpose during rectification work of 6.3 MVA, 33/11 KV Power Transformer Note- Old transformer oil reuse for servo stabilizers and distribution 11 KV transformers all as specified and directed by Engr-in-Charge.
Servicing and checking of Current / Potential Transformer / Lightening Arrester 11 and 33 KV including Comlete yard. (i) Checking of IR value with insulation tester of 5000 volts between phases to earth and between the phases with breaker open and close position and submitting the report. (ii) Operating timings closing/tripping with timer set and submitting the report. (iii) Gas pressure check through gas pressure gauge and submitting the report. (iv) Measuring of contact resistance with contact resistance meter (CRM) and submitting the report. (v) Checking of leakage of oil. (vi) Checking of IR value and submitting the report. (vii) Tightening of connections of control cables.
S&F for 11 KV lightening arrestor/surge arrestor complete all as specified and directed by Engr-in-Charge.
Supply and fixed Contact Assembly complete 33 KV 1250 Amp isolator switch (horizonal type) complete all as specified and as directed by Engr-in-Charge
Servicing and repairing of the battery bank with charger of standby supply from battery bank to all VCBs panel connection, 33/11 KV installed at 33 KV Main Receiving Station of GE (AF) Jammu, test result report also will be handover to JE E/M / Engr-in-Charge.
Supply and fixing in replacement of silca gel for Transformers complete all as specified.
Supply and fixing Cable Jointing Kit for 11 KV grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories of size 185 to 240 Sqmm complete all as specified and as directed and Engr-in-Charge.
Silica Gel breather for main tank, type : HPO-C, Gel Capacity 3.3 Kgs complete with Assembly complete all as specified and directed by Engr-in-Charge.
Silica Gel Breather for OLTC, type : HPO-A, Gel Capacity 1 Kg complete all as specified and as directed by Engr-in-Charge.
Danmet Chemical spray (DC> 2-26 having container 415ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricates, displaces and seals out moisture release rusted mechanism cleanse etc. complete all as specified and as directed by Engr-in-Charge. Make : Danmet Chemical Pvt Ltd
Taking out existing gravels/hardcore material from the bottom of substn/equipment completely for cleaning and spraying of anti grass chemical and screnning the hardcore material and refill the same at places complete all as specified and directed by Engr in charge. Note : Anti Grass chemical and loose filling of aggregate for topping up will be measured and paid separetly respective item of BOQ item No 2.
M&L for cleaning away all grass vegetation, scapling shrubs bushes under grouth roots and trees not exceding 30 cm grith and removing rubbish upto distance of 50 mtr out the periphery of area under cleaness complete all as specified and directed by Engr-in-Charge.
Painting of CT and PT plate covers with RYB coluor code and rusted portion of yard structure with two coat of super enamelled synthetic paint of smoke grey colour complete after preparing of old surface by scratching the old paint complete all as directed by Engr-in-Charge.
Supply, testing and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 11000 volts (Earthed) grade of size 120 sqmm 3 core complete all as per Engr-in-Charge.
Supply, testing and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 11000 volts (Earthed) grade of size 240 sqmm 3 core complete all as specified and directed by Engr-in-charge.
Supply, testing and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 11000 volts (Earthed) grade of size 95 sqmm 3 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches in hard/dense soil not exc 1.5 m wide and depth exc not exc 1.5 m for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 Sqm on plan and depth not exc 1.5 m and getting out complete all as specified and directed by Engr-in-charge.
Returning, filling in soil inculding spreading, leveling, watering & well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing surplus excavated soil to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed by Engr-in-charge.
Sand cushioning to under ground cable, provided with 8 cm thick layer before laying the cable and 15 cm thick layer after laying and stretching the cable complete all as specified and directed by Engr-in-charge.
M& L for one layer of un-reinforced precast concrete cable cover class HV Type I,flat,size 300 x 180 x 40 mm laid flat in trenches over the cable with length of cover perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed by Engr-in-charge.
S&F GI tubing Medium grade 80mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
S&F cable route indicator made out of 25 x 25 x 3.15 mm angle iron, 250 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation complete all as specified and directed by Engr-in-charge.
Supply and laying or fixing in relacement 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and laying or fixing in relacement 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supplying and laying synthetic Rubber insulated mats 3.0 mm thick for voltage upto 33 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed by Engr-in-charge.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv of sizes 2m x 1m for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed by Engr-in-charge.
Supply LT fire resistant PVC self adhesive electrical insulaion tape high quality size minimum 18 mtr long x 1.8 CM width complete all as specified and directed by Engr-in-charge.
Supply HT Insulation tape High quality size minimum 20 mtr long x 1.8 CM width complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of 11KV support insulator suitable for 11KV VCB (VCB make Kirloskar & CG ), dismantling and mantling of VCB Panel labour charge,high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete all as specified and directed by Engr-in-charge.
Supply and installed in replacement of 2 KVA invertor with battery backup upto 5 hrs including maint free batteres of cap 250Ah x 2 Nos including necessary wiring all as specified and directed by Engr-in-Charge. Make:- Exide/Luminious/Microtech
S&F in replacement of Distribution chart For 33/11KV Sub Stn consisting of all the Distribution Sub stn and not less than 1.8 mtr x 1.5mtr made of Flex in aluminium composit panels all as specified and directed by Engr-In-charge.
Supply and fixing of RYB LED type indicator operating with DC supply all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of space heater 80 Watt suitable for 11 KV VCB complete all as specified.
Supply and fixing in replacement of Amp meter suitable for 11KV VCB CG/Kirloskar as per existing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Volt meter suitable for 11KV VCB CG/Kirloskar as per existing complete all as specified.
Supply and fixing in replacement fault alarm complete all as specified.
Supply and fixing in replacement of remote HV winding temparature indicator O-150 Degree Centigrade complete all as specified.
Supply and fixing in replacement of remote LV winding temparature indicator O-150 Degree Centigrade complete all as specified.
Supply and fixing in replacement of remote Oil temparature indicator O-150 Degree Centigrade complete all as specified.
Supply to power house best quality woodern Bamboo ladder min height 9.5 mtr , step to step standared height complete all as specified and directed by Engr-in-Charge.
Supply to power house best quality woodern Bamboo ladder min height 11 mtr, step to step standared height complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of energy saving environmental friendly, long life exclusive innvative die- cast aluminium IP65 flood light with high power LED's as light source, suitable high lighting architectural features with lens of capacity 150W LED 6000K, complete all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of energy saving environmental friendly, long life exclusive innvative die- cast aluminium IP65 flood light with high power LED's as light source, suitable high lighting architectural features with lens of capacity 120W LED 6000K, complete all as specified and directed by Engr-In-charge.
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr-in-Charge.
M&L for painting to steel gantry towers & beams for 33 KV outdoor type switch yard complete including all accessories and equipment, support, structrure including preparation of steel surface by scraping and removing old paint, applying two coats good quality of aluminium paint as per following:- (a) Approximatly 11 mtr high towers - 6 set (b) Approximatly 03 Mtr high Frame pole - 21 Nos (e) Greasing of all contact points in 33 KV switch yard. Note : All the painting work will be carried out in the 33KV yard after proper shut down from JKPDL with prior approval of Engr-in-Charge.
MAMTA ENTERPRISES (BID ID -3374794)
VIDHATA ELECTRICALS (BID ID -3366080)
SB ENTERPRISES (BID ID -3370539)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .