Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder as per NIT | |
| 2 | L2₹20.7 L+₹24,810 (1.21%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 bidder | |
| 3 | L3₹21.1 L+₹62,460 (3.05%)Rejected-Finance HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | L3 | Rejected-Finance Rejected being L3 bidder |
Tender Value
₹20.8 L
EMD Value
₹41,600
Closing Date
24 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, PIN- 914133, C/O 56 APO
CWEK/TOKEN-18/969 EWS/2025-26- PROVN OF 125 KVA GENERATOR SET FOR OTM ACCN UNDER GE 969 EWS JOB NO- LBCW/02/2024-25/RR BN
2025_MES_709783_1
CWEK/TOKEN-18/969 EWS/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 969 EWS
Class E and above and Category b i
7 documents required · 7 mandatory
₹500
GE 969 EWS
₹41,600
HQ 133 WORKS ENGRS
28 Jul 2025
23 May 2025
2 Jul 2025
23 May 2025
24 Jun 2025
6 Jun 2025
23 May 2025 - 26 May 2025
28 May 2025
Amount
Supply installation Testing & Commissioning of Diesel Engine driven generating set outdoor type of capacity 125 KVA suitable BHP, CPCB-IV nearest higher side 440 volts, AC 3 phase, 50 HZ 4 wire, 0.8 PF directly coupled alternator and engine water cooled with AMF Panel common steel base fixed on Cement concrete in foundation as per OEM recommendation DG set of 125 KVA platform with inbuilt AMF panel with 2 Nos suitable size of contactors as 01 No for main supply and 01 No for DG supply as per manufacturer recommendation and other accessories comprising of following. Note:- 1. The DG Set shall be designed considering the derating factor of altitude 5226 ft above sea level extreme cold climate in winters. The ambient temp varies from -10 degree C (in winter) to 35 degree C (in summer). 2. After considering of derating factor by Manufacturer on above location in ser No 1 the net output is reqd of 125 KVA DG set. 3. The Plinth shall be as per Manufacturer recommendation and the rate of plinth is deemed to be included in quoted rate. (a) ENGINE - ECO friendly for emission and noise (PCB NORM COMPLIACE) 4 stoke diesel Engine confirming to BS standered, 1500 RPM turbocharged water cooled complete with a provision for 10% overload capacity for one hour in 12 hours continous running on 125 KVA with standered accessories all as specified and required for safe handling and operation, salient features of accessories shall be as under:-
(i) Fly wheel with housing and starter ring for generating set. (ii) Dry pe Air filter. (iii) Lub Oil cooler assembly with accessories. (iv) Exhaust air manifold. (v) Exhaust silencer. (vi) Expansion bellow. (vii) Exhaust gas turbocharger. (viii) Fuel filter (pre micro). (ix) Lubrication oil filter. (x) 12 V electrical starting system with starting motor & battery charging alternator with self-starter and other auto electric accessories as recommended by manufacturer. (xi) Centrifugal by-pass filter. (xii) Front & rear engine mounting supports. (xiii) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge, Ammeter, electronic Hour meter, speedometer. (xiv) Safety against low lub oil pressure. (xv) Engine operation/Maintenance, spare parts Manual. (xvi) Engine test certificate. (xvii) Cold starting kit (xvii) Mechanical Governor (xviii) One MS frame suitable or mounting of Engine & alternator. (xix) Fuel tank of suitable capacity as per Manufacturer recommendation complete with fuel gauge inlet/outlet connections drain valve with plug etc.
(B) ALTERNATOR- Salient pole brushless copper wound type suitable for direct couple to engine self-excited, self-regulated with fast response thermistor type electronic automatic voltage withhold output voltage with in desired limit(+1%) Dynamically balanced 400/415 volts AC 3 phase 50 HZ, 4 wire 0.8 PF lagging 100 KW 1500 RPM star connected (4 wire) screen protected drip proof enclosures with radial fan mounted on rotor with insulation class- H suitable for ambient temperature varies from -4 degree C in winter to 35 degree C in summer with following accessories. (i) Battery of suitable capacity as per manufacturer recommendation with copper leads and terminals of suitable size. (ii) One set of AVM pads fitted on base frame (C) Acoustic Enclosure- Supply & install of Acoustic Enclosure suitable for 125 KVA DG set the degree of protection IP-42 conforming to IS-2147 as under:- (i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design Polyester based powder coated internally and externally with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The doors are gasketed with EPDM gaskets. (iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50mm thickness and density at 96 Kg /M3 covered with fiber glass cloth and perforated powder coats sheet specially designed alienators (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms (iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. (v) Emergency stop push button outside the container (vi) Provn of light inside the canopy 20W LED fitting with wiring and control switch
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sq mm 3.5 core, all as specified.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 core, all as specified.
M & L for earthing complete with galvanized Steel earth late electrode 60cm x 60cm x 6mm thick, pouried directly in ground (earth pit not less than 2.25 M deep below ground level, with top edge of the plate not less than 1.5 M below normal ground level, connected to and including Gl iron strip of size 32x6 mm flat by means of Gl bolts, nuts, and washers, protected by 40mm bore Gi light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia Gl medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggregate) including TMT reinforcement 80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embedded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-1 and all as specified and directed.
Excavation in trenches not exceeding 1,5 metre wide and not exceeding 1.5 metre in depth, for foundations, laying of pipes etc not exceeding 10sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in soft and loose soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm.in hard/dense soil, all as specified.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, all as specified.
Supply and laying of burnt clay building bricks, sub-class B (old size) Designation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and directed
M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second. yer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-I Note:-Sand shall be fine sand as specified for plastering.
M/S Inder Pal Singh (BID ID -3321383)
M/S ZAHOOR AHMAD KHAN (BID ID -3321213)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .