Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹65.4 LAdmitted-Finance | +0.00% | ₹65.4 L | L1 | Admitted-Finance |
Tender Value
₹65.4 L
EMD Value
₹65,430
Closing Date
23 Feb 2026, 5:00 pmClosed
S.E. Electrical Circle (RandB) Bhubaneswar
S.E. Electrical Circle (RandB) Bhubaneswar, Nirman Soudha, Unit-V, 751001.
Supply and Laying of L T Cable in under grounding system from Main line to different hostel, Urmila Hostel and Baidehi hostel) at P.M.E.C., Sitapali at B erhampur, Ganjam
2026_EICCL_125762_1
Bid Identification No.S.E.E.C (RandB) 28/2025-26
National Competitive Bid
Electrical Works
90 days
Sitapali, G anjam
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹65,430
29 Apr 2026
9 Feb 2026
24 Feb 2026
9 Feb 2026
23 Feb 2026
9 Feb 2026
9 Feb 2026 - 16 Feb 2026
S/I/T&Commissioning of CPRI tested LT outdoor type double door floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm hot dip galvanised & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.The rate is inclusive of foundation(3 ft).80X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication. In commer-1-01 number of 800A 4P Icu=100%Ics,50Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula(FROM TRANSFORMER) Busbar-1&2 04 numbers of 800Amps aluminum busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 03 numbers of 320A 4P MCCB,,36Ka LSIG MCCB with micro processor based release Ics=100%Icu( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA) Out going- 02 numbers of 200A 4P MCCB,,36Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA) Instrument- (i) phase indicating lamp with toggle switch & HRC fuse in all the incoming and outgoing feeders (ii) 06 sets of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication 1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN)
S/I/T&Commissioning of CPRI tested LT outdoor type double door floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm hot dip galvanised & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.The rate is inclusive of foundation(3 ft).40X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication. In commer-1-01 number of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula(FROM TRANSFORMER) Busbar-1&2 04 numbers of 400Amps aluminum busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 04 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA) Changeover- 01 numbers of 250A 4P ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA) Out going- 04 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA) Instrument- (i) phase indicating lamp with toggle switch & HRC fuse in all the incoming and outgoing feeders (ii) 01sets of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication 1 no. 3P+N 40kA type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN) Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
185sqmm 3 1/2 core
300sqmm 3 1/2 core
1 core 400 sqmm Al armoured cable (to be used from Transformer LT bushing to 800A outdoor panel incomer, 2 runs per phase)
3.5 core 35 sqmm
3.5 core 50 sqmm
4 core 10 sqmm
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x300 sq mm
3.5 core x185 sq mm
1 core 400 sqmm
4 core 10 sqmm
3.5 core 35 sqmm
3.5 core 50 sqmm
Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
Supplying and laying 25 mm x 5 mm G.I strip on surface or in recess for connection etc as required.
Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing as required
Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-polycab/KEI/Finolex/Gloster/v-guard/Havells/RR Kabel
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, 10kA single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year.
Changing of Silica Gel etc of existing100-1250kva Transformer.
Top up of the new transformer oil in existing 100-1250kva transformer as per required.
Replacement of jumper conducter with socket required as per site.
Supply and fixing of Danger plate
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka 3P+N with 63A 4P MCB, 10kA, C series shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 no 63A 4P MCCB 16kA,C series with on/off trip indication ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS//ABB FORMULLA) Busbar-1&2 04 numbers of 100Amps AL. busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Secure/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB/Secure/Legrand) with CTs 100/5A 3 nos class 1 type(Make-Siemens/Schneider/ABB/Secure/Legrand)
Supply and fixing of Indicator lamp with toggler switch and fuse
Lightning Arrester(12KV,5KA) Station Class
DP Colouring (Alluminium )
Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire/Flameklog
Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire/Flameklog
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.80 MB
DTCN.pdf
Tender Documents • 0.90 MB
BOQ_580353.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid