Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹23.7 LAdmitted-Finance WARD 04 TOWN SIWALKHAS BAGHPAT ROAD MEERUT | L1 | Admitted-Finance | ||
| 2 | L2₹27.8 L+₹4.2 L (17.6%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | Rejected-Technical GRAM JANI KHURD MEERUT | - | Rejected-Technical BID REJECTED BY COMMITEE |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
13 Nov 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE CD PWD MEERUT
EE CD PWD MEERUT
Construction of a box culvert at chainage 1.630 and special repair work from chainage 3.200 to 3.800 on the Ukhalina Dhadhara road
2026_CEMRT_1205240_13
2030/3A DT 13-10-2026
Open Tender
Civil Works
Fixed-rate
60 days
EE CD PWD MEERUT
ABCD
3 documents required · 3 mandatory
₹944
₹3.0 L
EE CD PWD MEERUT
26 Nov 2026
5 Nov 2026
13 Nov 2026
5 Nov 2026
13 Nov 2026
5 Nov 2026
5 Nov 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of Structures/Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202./By Mechanical Means/Reinforced Cement Concrete | 2 | Cum | 1,030 | ₹2,060 |
| 2 | Dismantling Brick/Tile Work/Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202./Cement mortar | 12 | Cum | 400 | ₹4,800 |
| 3 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row / Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. / (B) 1000 mm dia | 5 | Mtr | 9,100 | ₹45,500 |
| 4 | Brick Soling / Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412 | 90 | Sqm | 550 | ₹49,500 |
| 5 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | 130 | Cum | 404 | ₹52,520 |
| 6 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 C.C. grade M 15 | 13 | Cum | 6,050 | ₹78,650 |
| 7 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m / IV. R.C.C. grade M 25 | 45 | Cum | 7,850 | ₹3,53,250 |
| 8 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m / III. C.C grade M 20 | 58 | Cum | 7,100 | ₹4,11,800 |
| 9 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 | 10 | MT | 71,000 | ₹7,10,000 |
| 10 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 | 32 | Nos | 180 | ₹5,760 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.98 MB
Tendernotice_2.pdf
PDF • 1.21 MB
BOQ_2283673.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .