Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6,490Qualified Make: NA
Model: TIPL DMM97 0 SRISHTI PLAZA COMMERCIAL PREMISES COOPERATIVE SOC SRISHTI PLAZA UNIT NO 011 GROUND FLOOR OFF SAKI VIHAR ROAD MUMBAI MAHARASHTRA 400072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | Make: NA
Model: TIPL DMM97 | L1 | Qualified | |
| 2 | L2₹15,000+₹8,510 (131.1%)Qualified Make: GWINSTEK
Model: GW Instek GDM-461 111 1ST FLOOR LAXMI DEEP TOWER LAXMI NAGAR DISTT CENTRE LAXMI NAGAR DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: GWINSTEK
Model: GW Instek GDM-461 | L2 | Qualified | |
| 3 | L3₹20,160+₹13,670 (210.6%)Qualified Make: Metrel
Model: Metrel MD 9030 True RMS H NO 6 3 902 A FLAT NO 310 CENTRAL COURT APARTMENTS RAJ BHAVAN ROAD SOMAJIGUDA HYDERABAD TELANGANA 500082 | HYDERABAD | TELANGANA | 500082 | Make: Metrel
Model: Metrel MD 9030 True RMS | L3 | Qualified | |
| 4 | L6₹30,000+₹23,510 (362.2%)Qualified Make: FLUKE
Model: Digital Multimeter (FLUKE) (Fluke 87 V Industrial Multimeter) 8 A MANGALDEEP APPARTMENT OPP PRJAPTI COLONY B S GAYATRI SOC SAIJPUR BOGHA SAIJPUR BOGHA AHMEDABAD | Make: FLUKE
Model: Digital Multimeter (FLUKE) (Fluke 87 V Industrial Multimeter) | L6 | Qualified | |
| 5 | L7₹37,680+₹31,190 (480.6%)Qualified Make: KUSAM-MECO
Model: KUSAM-MECO KM 839 F 31 MIDC SATPUR NASHIK CITY MAHARASHTRA SATPUR MIDC NASHIK NASHIK MAHARASHTRA 422007 | NASHIK | MAHARASHTRA | 422007 | Make: KUSAM-MECO
Model: KUSAM-MECO KM 839 | L7 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
6 Nov 2018, 10:00 amClosed
digital multimeter MSME Exemption For Years Of Experience And Turnover Yes Digital Multimeter ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 4.5 3.5
4.5
6.5 Measurement Type True RMS Average
True RMS Counts 50000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600
1000 DC Voltage Accuracy 0.05 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.001 0.001
0.01
1
10
100 AC Voltage Range 1000 600
1000 AC Voltage Accuracy 0.5 0.08
1 AC Voltage resolution 0.001 0.001
100 1/5 DC Current Range 10 3
10 DC Current Accuracy 0.05 0.005
1.5 DC Current resolution 0.001 0.001
100 AC Current Range 10 3
10 AC Current Accuracy 0.5 0.5
1.5 AC Current resolution 0.001 0.001
100 Resistance Range 500 40
50
60
100
500 Resistance Accuracy 0.08 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.01 0.001
100 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 1.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 0.001 0.001
NA Frequency Range ( KHz ) 300 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.001 0.001
NA Temperature Range ( Degree C ) -50 to 1000 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 1.5 1.5
NA Temperature resolution ( Degree C ) 0.1 0.001
NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available
Internal Memory min. 5000 points/200 readings * Computer Interface along with software Not Available * Dimensions ( mm X mm X mm ) - * Weight 870 * Other Features - * 2/5 SAFETY Safety Rating Category IV 600 V of IEC 61010 Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification UL
CE
CSA
TUV
VDE * POWER REQUIREMENTS Power Requirements Battery Operated * if Battery Operated
then Type of Battery Non- Rechargeable (Alkaline) * if rechargeable
then chemistry of the battery NA * if Non-rechargeable
then size of the battery cell AA * number of non- rechargeable the battery/cell 4 * Voltage of rechargeable Battery 1.5 * capacity of rechargeable battery(milli Ampere Hour) -2 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment - * WARRANTY Warranty 5 1
5 OPERATING CONDITION Minimum Operating Temperature -20 * Maximum Operating Condition 55 * Operating Humidity (RH) 90 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bhikshapathy Kawati 500058
DRDL
KANCHANBAGH P.O. 2 30
781551
GEM/2018/B/109641
digital multimeter
30 days
Telangana; Hyderabad
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter MSME Exemption For Years Of Experience And Turnover Yes Digital Multimeter ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 4.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 50000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.05 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.001 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 1000 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.5 0.08 | - | - | - |
| 1 AC Voltage resolution 0.001 0.001 | - | - | - |
| 100 1/5 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 0.05 0.005 | - | - | - |
| 1.5 DC Current resolution 0.001 0.001 | - | - | - |
| 100 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 0.5 0.5 | - | - | - |
| 1.5 AC Current resolution 0.001 0.001 | - | - | - |
| 100 Resistance Range 500 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 0.08 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.01 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 1.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 0.001 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 300 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.001 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -50 to 1000 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 1.5 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 0.1 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available | - | - | - |
| Internal Memory min. 5000 points/200 readings * Computer Interface along with software Not Available * Dimensions ( mm X mm X mm ) - * Weight 870 * Other Features - * 2/5 SAFETY Safety Rating Category IV 600 V of IEC 61010 Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL | - | - | - |
| CE | - | - | - |
| CSA | - | - | - |
| TUV | - | - | - |
| VDE * POWER REQUIREMENTS Power Requirements Battery Operated * if Battery Operated | - | - | - |
| then Type of Battery Non- Rechargeable (Alkaline) * if rechargeable | - | - | - |
| then chemistry of the battery NA * if Non-rechargeable | - | - | - |
| then size of the battery cell AA * number of non- rechargeable the battery/cell 4 * Voltage of rechargeable Battery 1.5 * capacity of rechargeable battery(milli Ampere Hour) -2 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment - * WARRANTY Warranty 5 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature -20 * Maximum Operating Condition 55 * Operating Humidity (RH) 90 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bhikshapathy Kawati 500058 | - | - | - |
| DRDL | - | - | - |
| KANCHANBAGH P.O. 2 30 | - | - | - |
Exempted
6 Nov 2018
25 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_781551.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .