Tender Value
₹11.1 L
Closing Date
19 Feb 2021, 6:00 pmClosed
Asst. GM(Engg-Elect)
AAI, Calicut International Airport
Replacement of Old Split AC units at various locations and provision of new split AC units for Arrival Baggage Claim area at Agatti Airport
2021_AAI_69719_1
AAI/AGT/Engg(E)/AC/NIT-03/2021
Open Tender
Electrical Works
Works
90 days
AAI Agatti Airport
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,120
Exempted
29 Jun 2021
10 Feb 2021
22 Feb 2021
11 Feb 2021
19 Feb 2021
11 Feb 2021
11 Feb 2021 - 18 Feb 2021
Amount
Supply, installation , testing and commissioning of Hi-Wall mounted 2.0 TR Split AC of 3 star rating with rotary compressor complete with initial charging with proper environment friendly refrigerant suitable to work on voltage 230 V +/- 10 % AC, 50 Hz, single phase, interconnecting power and control cable, refrigerant piping and drain pipe between indoor and outdoor unit(upto a length of 10 ft), pipe and cable covered with white tape complete as required.
Supply, installation , testing and commissioning of 5 KVA capacity suitable for operation on 230V, 50 Hz (Nominal rating) AC supply.
Extra for additional refrigerant piping between indoor unit and outdoor unit beyond 3.5 Mtr length alongwith power and control cable, copper pipe insulation, covering with white tape etc complete as required
Supply and laying of PVC Drain pipe of 25mm dia insulated with 6 mm thick nitrile rubber insulation(for indoor area portion to prevent condensation) s complete with necessary elbow, tees, reducer, connector complete as required.
Providing and fixing MS bracket/stand duly painted suitable for mounting of outdoor unit of 2 Ton AC as required
Providing and fixing the following on surface / angle iron frame / recess including connections, earthing the body, testing, commissioning etc. as required(But without MCB/RCCB/Isolator): TPN 4 Way MCB DB double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 Amps amps rating, 240/415 volts, 10 kA, “C” curve, three pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 Amps amps rating, 240/415 volts, 10 kA, “C” curve, four pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, laying,termination of 3C X 4 sqmm copper conducter insulated flexible unarmoured cable on surface /recess /above false ceiling /concealed space/ wall/ pipe /trunking etc.complete in all respects as required
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal/plastic enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel/plastic enclosure, on surface or in recess, with cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Havells Cat No. DHDCUSN020 or equivalent)
Supply and fixing of PVC / Plastic trunking (openable / type) for covering refrigerant copper pipe, drain pipe , cable etc between indoor unit and outdoor unit as required
Construction of pedestal/platform of suitable size for installation of split AC outdoor unit made out of cement concrete/ bricks block , PCC base finished with cement plastering and painted with approved shade of paint as required
Dismantling the existing Split AC unit comprising of indoor and outdoor unit and its accessories and shifting to a single point etc as required.
Buy back of old split of 1.5 TR rating
Buy back of old split of 2.0 TR rating
Buy back of old split of 3.0 TR rating
VOLKS ENERGIE PVT LTD
Ganga Enterprises
DEEPAKELECTRICALS
Mohammed Shafi C.K
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .