| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC BEING L1 ACCEPTED | |
| 2 | L2₹7.8 L+₹490 (0.06%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-Finance L1 BEING ACCEPTED | |
| 3 | L3₹9.1 L+₹1.2 L (15.7%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L3 | Rejected-Finance L1 BEING ACCEPTED |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
23 Dec 2021, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Maint/Repair/Replacement of Internal electrification wiring DBs Sub Main Wiring Bldg earthing E/M fitting and fixtures and repair/servicing of ceiling fans Pedestal fans exhaust fans Geysers at CGRA Meenambakkam Thalakancherry and CGAS Air Stationetc
2021_MES_475018_4
8891/GE(I)(CG)
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹16,000
Yes
19 Jan 2022
8 Dec 2021
25 Dec 2021
8 Dec 2021
23 Dec 2021
11 Dec 2021
Amount
Taking down carefully copper/aluminium point wiring (light,fan, socket or power) including fixture and fittings complete including removing material from site and taken as credit and making good the disturbed surface of wall/floor etc to match with the existing surfaces complete all as specified and as directed.
Taking down carefully submain wiring with aluminum conductor cable 4/6/10/16 Sqmm with PVC conduit concealed/ on surfacecomplete including removing material from site and taken as credit and making good the disturbed surface of wall/floor etc to match with the existing surfaces complete all as specified and as directed.
Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non metallic rigid PVC conduit of 20 mm dia concealed / PVC casing/capping along with FRLS 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof and including 2mm thick terminal boxes MS sheet flush mounted with 3mm thick laminated hylem sheet for mountling switches, socket, fan regulators etc complete for one light point or one fan point controlled by one switch complete all as specified and as directed. Note: Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. Make of PVC conduit /casing/capping : Avon plast/ Kon seal / Garware.
All as per item No.03 here in before but one light point controlled by two way switches.
All as per item No.03 here in before but One 3 pin socket outlet 5 amps , independent .
All as per item No.03 here in before but One 3 pin socket outlet 5 amps ,on the same board with other switches.
All as per item No.03 here in before but One bell /buzzer point controlled by one push button on the same board with other switches,independent .
Material and labour for Point wiring with 4 Sqmm single core FRLS PVC insulated unsheathed copper conductor cable, drawn into and including non metallic rigid PVC conduit of 20 mm dia concealed / PVC casing/capping along with 4.0 sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof and including 2mm thick terminal boxes MS sheet flush mounted with 3mm thick laminated hylem sheet for mountling switches, socket, fan regulators etc complete for One 3 pin socket outlet 15 amps , independent .complete all as specified and as directed. Note: Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware.
Removing unserviceable wiring from conduit/batten/casing/caping on surface of wall/ceiling and Material and Labour for 2x1.5 sqmm (Nominal area) FRLS unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into existing non metalic rigid PVC conduit of 20 mm dia complete all as specified and asdirected. Note:- Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian..
Material and labour for Sub main wiring with two run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 4.00 Sq mm single core , multi stranded copper conductor PVC insulated unsheathed FRLS cable as earth continuity conductor drawn into existing non metallic PVC conduit 25 mm dia and conduct accessories. PVC casing /caping concealed/surface of wall/ceiling/roof complete all as specified and as directed. Notes: (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. (ii) Three different color wires shall be used for phase, neutral and earth. (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . (iv) Three run of 4.0 Sqmm cable and one run of 25 mm dia PVC conduit/casing caping will be measured as one unit. (v)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian.
Material and labour for Sub main wiring with four run of single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and two run of 4.00 Sq mm single core , multi stranded copper conductor PVC insulated unsheathed FRLS cable as earth continuity conductor drawn into existing non metallic PVC conduit 25 mm dia and conduct accessories. PVC casing/caping concealed/surface of wall/ceiling/roof complete all as specified and as directed. Notes: (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. (ii) Five different color wires shall be used for phase, neutral and earth. (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . (iv) Six run of 4.0 Sqmm cable, and one run of 25mm PVC conduit/casing caping will be measured as one unit. Make of cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware.
Material and labour for Sub main wiring with four run of single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 6.00 Sq mm single core , multi stranded copper conductor PVC insulated unsheathed FRLS cable as earth continuity conductor drawn into existing non metallic PVC conduit 32 mm dia and conduct accessories. PVC casing/caping concealed/surface of wall/ceiling/roof complete all as specified and as directed. Notes: (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. (ii) Five different color wires shall be used for phase, neutral and earth. (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . (iv) Five run of 6.0 Sqmm cable, and one run of PVC conduit will be measured as one unit. Make of cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware.
Material and labour for Sub main wiring with four run of single core 10 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 10.00 Sq mm single core , multi stranded copper conductor PVC insulated unsheathed FRLS cable as earth continuity conductor drawn into existing non metallic PVC conduit 32 mm dia and conduct accessories. PVC casing/caping concealed/surface of wall/ceiling/roof complete all as specified and as directed. Notes: (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. (ii) Five different color wires shall be used for phase, neutral and earth. (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . (iv) Five run of 10.0 Sqmm cable, and one run of 25mm PVC conduit/casing caping will be measured as one unit. Make of cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware.
Supply and fix socket flush type 5 in one ,5Amp/240 Volts including taking down old unserviceable socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix socket flush type 5 in one, 16 Amp/240 Volts including taking down old unserviceable switches and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Switch piano flush type single pole one way 5 A 240 Volts including taking down old unserviceable switches and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Switch piano flush type two way 16 A 240 Volts including taking down old unserviceable switches and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Switch socket combination 2 in 1, 3/5 pin, 6 Amps Flush type 240 Volts including taking down old unserviceable switches socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Switch socket combination 2 in 1, 3/5 pin, 16 Amps Flush type 240 Volts including taking down old unserviceable switches socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Modular switch 6 Amps one way flush type 240v AC,including taking down old unserviceable modular switch and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Modular switch 6 Amps two way flush type, 240v AC, including taking down old unserviceable modular switch and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Modular socket 3 pin 6 Amps flush type 240v AC, including taking down old unserviceable modular socket and taken as credit complete all as specified and directed. Make: Legrand/Anchor/ABB
Supply and fix Modular socket 3 pin 16 Amps flush type , 240v AC, including taking down old unserviceable modular socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB
Supply and fix Stepped type electronic fan regulator flush type , 240V on the existing phenolic laminated sheet including taking down old unserviceable one and taken as credit complete all as specified and directed Make :Legrand/Anchor/Rider
Supply and fix Modular type electronic ceiling fan regulator, 2 module, 240 V including taking down old unserviceable one and taken as credit complete all as specified and directed Make: Legrand/Anchor/Rider.
Supply and fix ceiling rose 3 terminals PVC / Polycarbonate, isolated body complete all as specified and as directed. Make : Baja/Anchor/HPL
Supply and fix Lamp holder PVC / Polycarbonate, isolated body including taking down old unserviceable lamp holder and taken as credit complete all as specified and directed.
Supply and fix Call bell ding dong, AC, 240 V, single pole, including taking down old unserviceable calling bell and as credit complete all as specified and as directed. Make:- BajajRider/HPL
Supply and fix modular white cover plate with frame 2- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 3- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 4- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 6- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular white cover plate with frame 8- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 1/2 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 3 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 4 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 6 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and fix modular metal flush box for 8 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply and replace electronic ballast 36W in place of 40 Watts suitable for T8 FTL fittings complete all as specified and as directed.Make:Make :Surya/ /Philips/ Bajaj/CG
Supply and replace electronic ballast 28 Watts suitable for T5 FTL fittings complete all as specified and as directed.Make:Make :Surya/ /Philips/ Bajaj/CG
Supply and replace bi pin holder 36/40 Watts complete all as specified and as directed.Make:Make :Surya/ /Philips/ Bajaj/CG
Supply and replace tube rod 4 feet 36 Watts T- 8 complete all as specified and as directed.Make:Philips/Bajaj/CG
Supply and replace tube rod 4 feet 28 Watts T- 5 complete all as specified and as directed.Make:Philips/Bajaj/CG
Supply and fix sheet metal enclosure powder coated double door for Board distribution box with 200 Amps rated bus bar, MCB DB SPN 2 way , 240Volts including , Disconnecting electric connections, dismantling from position unserviceable DBs and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix sheet metal enclosure powder coated double door for Board distribution box with 200 Amps rated bus bar, MCB DB SPN 4 way , 240 Volts including , Disconnecting electric connections, dismantling from position unserviceable DBs and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix sheet metal enclosure powder coated double door for Board distribution with box 200 Amps rated bus bar, MCB DB SPN 8 way , 240 Volts including , Disconnecting electric connections, dismantling from position unserviceable DBs and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix sheet steel enclosure with socket plug top and MCBs complete single pole and neutral enclosure with 2- Pin and earth plug and socket complete with single pole MCB 25 Amp(DBOXX COMBO DP) capacity including fixing in walls duly embedded complete all specified as directed. Make:Indo Asian/L&T/Siemen
Supply and fix MCB 5-32A single pole 240 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix MCB 5-32A single pole and neutral, 240 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix MCB TP 5-32 Amps, 415 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix MCB TPN 5-32 Amps, 415 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix MCB TP 63Amps, 10 KA, 415 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen
Supply and fix MCB TPN 63-100Amps, 10 KA, 415 Volts including removing of old unserceable MCB complete all as specified and directed.Make:- Indo Asian/L&T/Siemen
Taking down unserviceable Electric meter of any type and capacity from meter box and removing and deposit to MES store complete all as specified and as directed.
Supply and fix Microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amp, 230 V, with optical communication port,conforming to IS:13779 complete all as specified and as directed.Make:L&T/Siemen
Supply and fix Microprocessor based Three phase electronic tamper proof energy meter of rating 10 to 60 Amp, 415 V, with optical communication port,conforming to IS:13779 complete all as specified and as directed. Make:L&T/Siemen
Taking down carefully unserviceable ceiling fans of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle, reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm (24/0.2mm) FRLS PVC flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and as directed. Notes :- Spare parts required for repair of defective parts will be measured and paid separatly under relevent items here in after.
Description all as per Sl item No 58 here in before but exhaust fan of any size
Description all as per Sl item No 58 here in before but wall mounted fan of any size.
Supply only ball bearing suitable for ceiling fan, exhaust fan, pedestal fan of same size as per existing defective one complete all as specified and as directed.(Make : Tata/SKF/NBC)
Supply only bush bearing suitable for ceiling fan, exhaust fan and pedestal fan complete all as specified and as directed.(Make : Tata/SKF/NBC)
Supply only condenser 2.5 MFD complete all as specified and as directed.(Make : usha/Keltron/Uptran)
Supply only condenser 4 MFD complete all as specified and as directed.(Make : usha/Keltron/Uptran)
Supply only shackle accessories complete with rubber bush, bolt, nut, split pin complete all as specified and as directed.
Cleaning and preparing the surfaces of ceiling fan of any size, removing the grease, carbon dust over the fan and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed.
Cleaning and preparing the surfaces of exhaust fan of any size, removing the grease, carbon dust over the fan and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed.
Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as per the old one, insulating, varnishing and pre heating for ceiling fan of 1200mm/1400mm sweep complete all as specified and as directed.
Description all as per Sl No 68 herein before but Exhaust fan upto 300mm sweep.
Description all as per Sl No 68 herein before but Exhaust fan above 300mm upto 450mm sweep.
Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and as directed. Notes :- Spares required for replacement will be measured and paid seperately.
Supply only new heating element of capactity 1.5KW with rubber gasket complete all as specified and as directed.Make:Racold/Venus/Bajaj
Supply only new heating element of capactity 2 KW with rubber gasket complete all as specified and as directed..Make:Racold/Venus/Bajaj
Supply only thermostat suitable for storage type water heater complete all as specified and as directed. Make:H-GURU/PIE BIG
Supply only Pressure release valve 15mm dia suitable for geyser complete all as specified and as directed.Make:KIRLOSKAR/L&T/LEADER
Supply only Air release valve 15mm dia suitable for geyser complete all as specified and as directed.Make:KIRLOSKER/L&T/LEADER
Supply only 3 core 2.5 Sqmm copper conductor FRLS PVC cable suitable for geysers of any size complete all as specified and as directed.(Make : Finolex/Poly cab /Plaza)
Supply only Non return valve 15mm dia suitable for geyser complete all as specified and as directed.Make:KIRLOSKER/L&T/LEADER
Supply and fix 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and as directed.(Make :Indo asian/ legrand/L&T)
Material and labour for Preparing external surfaces of water heater, cleaning and painting with one coat of synthetic enamel paint of white colour of approved make with brush and writing MES No complete all as specified and as directed.
Supply only Aparatus plate assembly suitable to fix thermostat, heating elements of geyser with nuts etc complete all as specified and as directed.
Supply only Fusible plug for geyser complete all as specified and as directed.(Make :Indo asian/ legrand/L&T)
Removing the copper tank from the geyser of any size , brazing to arrest the leakage, reassembling and refixing complete all as specified and as directed.
Supply and fix Bottom inspection chamber cover suitable for 25 Litres capacity geyser of any make/model complete all as specified and as directed.
Supply and fix Indication lamp suitable for geyser in round/rectangular shape complete all as specified and as directed.
Supply and replace 3 pin plug 15 Amps capacity complete all as specified and as directed, (Make: Anchor/Plaza)
Supply, fix and test water heater storage type (Geyser) of capacity 25 litres capacity, 5 Star rating, 2 KW heating element, ergoniminally styled plastic body. Unique temparature indicator dial, adjustable thermostat, magnesium anode for extra protection from corrison and leakage, glass line inner tank, PUF insulation, product warranty 2 years, Tank warranty 7 years, heating element warranty 3 years rust & shock proof autocut facility complete fixed at location as directed including one non return valve & one safety valve inbuilt of geyser fire retardant ISI mark supply cord with plug top and electrically operated suitable for 230 volts and cold water line 01 No and anchor bolts complete all as specified and directed. Note : Anchor bolt shall be grouted with hammer drill only. Make of Geyser : Bajaj /Racold/Venus
Removing unserviceable existing geyser tank and replacement of new tank of capacity 25 Ltrs made out of stainless steel and old one taken as credit complete all as specified and directed
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth strip of 32x6mm by means of bolts,nuts check nuts and washers of GI all as shown in electric plate No 3 connecting to earthing test point including necssary exacavation in any earth strata , PCC chambers in PCC 1:3:6 type C1, RCC 1:2:4 type B1 cover slab 50mm thick with 8 mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle watering pipe of GI 20 mm dia medium grade, funnels, lug and charcol,salt etc all as applicable and as per plate No 3 of SSR part 1 connecting test point and testing on completion and taking out old un serviceable earthing and taken as credit complete and all as specifed and as directed . Notes:-The rates quoted is inclusive of galvanised earth strip of 32x6mm conductor upto a length of 7.5m from the earth pit.
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32x6 mm galvanised iron strip complete and all as specifed and as directed .
Supply Only LED light fitting 4 feet white, 20W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed. Make:- Philps Cat Part No. BN021C LED20 S PSU CW GR S2 In case the make mentioned above is not available in market then equivalent price and specification in M/S Wipro /M/S Bajaj
Supply Only LED light fitting 2 feet white, 10W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed. Make:- Philps Cat Part No. BN 021 LED10S- 6500 PSU GR S1 or equivalent price and specification in M/S Wipro
Supply and replace Bell push 5A flush type including taking down old unserviceable Bell push and taken as credit complete all specified and as directed.. Make:- Legrand/Anchor/ABB
Supply Only LED Bulb 9 Watt including taking unserviceabl old fitting etc complete all as specified and as directed. Make :Philips/Wipro/CG
NOTE: The supply only item Nos: 91 and 92 mentioned in BOQ shall be executed as per monthly demand/repair raised from the CG unit concerned. The contractor will supply as per demand raised by the user to MES. The Department will issue Receipt Vocher for the above item supplied by the Contractor. Original Paid Voucher with GST Paid for the purchase of above items shall be produced to GE`s office before claiming the above items in RAR by the contractor. The fixing of above items will be executed through DL held with AGE E/M office through Baby Indent/Job card daily and Register in this regard shall be maintained by JE/AGE duly signed by User Periodically.
EVEREST ENGINEERING WORKS
Banyan Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .