Tender Value
₹1.4 L
EMD Value
₹1,450
Closing Date
9 Oct 2026, 3:00 pm
EE, PWD
Projects Division ,Trichy
Providing 2 Nos Air Conditioning arrangements to the H H Rajahs College Autonomous Pudukkottai.
2026_HE_708027_1
02/ 2026 /dated 25.09.2026
Open Tender
Electrical Works
Percentage
Pudukkottai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1,450
25 Sept 2026
25 Sept 2026
9 Oct 2026
25 Sept 2026
9 Oct 2026
25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing of 25Amps flush type wall Socket with 25A DP MCB in flush with wall earth Connection (for AC plug) (Higher end make) | 2 | Nos | 1,264 | ₹2,528 |
| 2 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unshethed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 Sqmm Pvc Insulated Unsheated Copper wire and making good of the Concealed portion with suitable Colour. | 25 | mtrs | 334 | ₹8,350 |
| 3 | Supply erection testing and commissioning of 2TR (6000 K. cal/hr) split type Air conditioner conforming to IS: 1391 (Part 2) 1992 with Amdt No.1 to 2 fitted with compressor operating on non CFC refrigerant suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 3 star rating as per BEE specification and capable of performing the funtions of 1) Cooling 2) Dehumidifying 3) Air Circulating 4) Filtering The installation fworks for the above spit rype AC units includes the following 1.Mounting/Fitting indoor and outdoor units at their respective locations. 2. Laying refrigerant copper pipelines of (5/8" & 3/8") 3 medters lingth including drilling holes in the wall if required thickness of the copper tubing shall not be less than 0.7mm. 3. Insulatingthe suction pipe with expaned polyurethelene foam 5mm thick tubing 4. Laying 25mm PVC drain pipe of 6 mts. Length to drain out the condensate water being formed in the inidoor unit. 5.Leak testing the entire gas unit 6. Charging refregrant gas in the unit. 7. Suitable electric wiring to be provided with 3 core 2.5sqmm PVC insulated copper wire between indoor and outdoor units upto 3 mtrs. Length and upto switch within 3 mtrs. of location of indoor unit (career/voltas/diekin) make only. | 2 | Nos | 46,140 | ₹92,280 |
| 4 | Supply and fixing of 5 KVA Electronic automatic voltage stabilizer with input range of 170-270V and copper range 200 -240V with high and low voltage cutoff and 3 minutes time delay relay suitable for operation on 230V/50HZ single phase AC supply. | 2 | Nos | 4,646 | ₹9,292 |
| 5 | Supply and fixing of 5/8 3/8 Copper pipes (Extra beyond 3 meters supply with AC unit) with installation foam of 6mm thickness suitable for split type AC unit. | 8 | mtrs | 980 | ₹7,840 |
| 6 | Supply and fixing of water drain pipe line (1" PVC pipe) | 8 | mtrs | 58 | ₹464 |
| 7 | Supply and fixing MS stand for fixing outdoor unit | 2 | Nos | 979 | ₹1,958 |
| 8 | SUB TOTAL | 1 | nos | - | - |
| 9 | GST @ 18 % | 1 | nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
PdkCONDITION.pdf
Tender Documents • 0.14 MB
BOQ_850898.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .