Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC Being first lowest | |
| 2 | L2₹26.8 L+₹9,720 (0.36%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹27.7 L+₹1.0 L (3.79%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹27.8 L+₹1.1 L (4.25%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹30.7 L+₹4.1 L (15.3%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
30 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
PROVN OF CERTAIN MW AND SPL REPAIR AT LALGARH JATTAN MILITARY STATION
2022_MES_560404_1
8933-45/22-23
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender documents
7 documents required · 7 mandatory
₹500
GE Lalgarh Jattan
₹66,000
Yes
19 Dec 2022
29 Oct 2022
3 Dec 2022
29 Oct 2022
30 Nov 2022
14 Nov 2022
Amount
B/R Portion Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) complete all as specified and directed by Engr-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engr-in-charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engr-in-charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engr-in-charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 on wall finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for two coats of acrylic distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces complete all as specified and directed by Engr-in-charge.
M&L for complete removal of existing treatment and two coats of acrylic distemper over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engr-in-charge.
M&L for 3 coats of white wash on newly plastered surfaces incl preparation etc. on ceiling complete all as specified and directed by Engr-in-charge..
M&L for two coats of cement base paint on newly plastered surfaces incl preparation etc. wall complete all as specified and directed by Engr-in-charge.
M&L washed stone grit plaster on exterior walls in two layers, under layer 12 mm cement plaster 1:4, furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 coarse sand : 2 stone chipping 10mm nominal size) (using white cement in place or ordinary cement in the top laayer) in panels with groove as per approved pattern incuding scrubbing and washing, the top layer with bruses and water to expose the stone chippings complete all as specified and directed by Engr-in-charge. (Note :- payment for providing grooves shall be made separately)
M&L forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, naild to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specification and direction of the Engineer-in-Charge.
Providing and Applying rising damp proof coating system with single component ready to use damp proof coating 1. Preparation :- Throughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc all large voids and hallow portions must be removed and re-plastered non moving cracks having width upto 5mm must be filled with polymer based crack filler. 2. Application :- Apply the first coat of Dr. fixit dampguard classic with a paint brush directly on the prepared surfaces by mixing (1 part base : 1 part hardner : 1 part of water), allow to dry for a minimum 2-3 hrs. apply one part of Dampguard mixed chemical and 2 parts of OPC white cement / Birla putty and make the putty, apply putty on the entire surface area, allow to dry for at least 3-4 hrs, apply the final coat of air cure 48 hrs proceeds for paints.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engr-in-charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in dada and skirting over and including 10 mm thick rendering on vertical surface in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engr-in-charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engr-in-charge.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engr-in-charge.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including over 20 mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engr-in-charge.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas compleet all as specified and directed by Engr-in-charge. Note : Reinforcement shall be measured and paid seperately.
S&F for mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip all as specified & directed by Engineer-in-Charge.
S&F for mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip all as specified & directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
M&L for continous brick edging with fly ash bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically all specified and directed.
Material and labour for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, Material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as directed by the Engineer-in-Charge. (i) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. NOTE:- Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit/Fosroc/BASF/STP
M&L for PCC (1:5:10) using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified & directed by Engr-in-charge.
Dismantling of brick tiles in floor laid dry and pointed in cement morter complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 complete all as specified & directed by Engr-in-Charge.
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen.Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified & directed by Engr-in-Charge.
Material and labour for repair to damage RCC coloumns/Beam/Slab/Chajja by using micro mortar and concrete in Following Stages :- (a) Removing the mortar and loose concrete from RCC elements. (b) Cleaning the rusted reinforcements and applying rust removal. (c) Inserting the addl reinforcements in cape the coves sectional area reduction in more than 20 percent welding the reinforcement with existing area and supporting adequate on walls if reqiurd with grout. (d) Providing micro morter and concrete over bond coat to cover the reinforcements and slet surface. (e) Providing adequate from wave and scaffolding if required. (f) Curing the surface. Note :- (i) Rust removal, bonding agent, grout, micro morter and concrete and related chemicals shall be of Dr Fixit/BASF and STP (ii) Work is to be got executed from authorised applications and company. (iii) Steel measured and paid separately
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engr-in-charge.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engr-in-charge.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed by Engr-in-charge. (Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required built in colour in three legged of cross-section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood in all three legs frame shall be covered with fibreglass from all sides MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) panelled door shutter conforming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings, cast molithically with 5mm thick FRP laminated for panels including fixing to frames, complete all as specified and as directed by Engineer-in- charge.
S & F for Pressed steel frames size of frame 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engr-in-charge.
S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-charge.
S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engr-in-charge.
S&F for 100 mm long butt hinges with stainless steel hinge pin, anosied and fixed complete all as specified and directed by Engr-in-charge.
S&F for 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and directed by Engr-in-charge.
S&F for 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed by Engr-in-charge.
S&F for 100 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed by Engr-in-charge.
S&F for 300mm long mild steel sliding door bolt type not less than 16mm dia fixed all as specified & directed by Engr-in- charge.
S&F for 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engr-in-Charge.
S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-charge.
S&F for 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed by Engr-in-charge.
S&F for 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engr-in-charge.
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr-in-charge.
M&L for preparation of old or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed by Engr-in-charge.
S&F for powder coated aluminium frame/shutter for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of poweder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete all as specified and directed by Engr-in-charge. Make of Al Section : Jindal / Hindalco / NALCO
S&F for powder coated anodised aluminium window and ventilator shutters, side hung type without sash, aluminium sections weighing exc 0.55 Kg/m (1.50 to1.80mm th) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified and directed by Engr-in-charge.
S & F for Aluminium anodised (Powder coated) Three track sliding window frame with shutters (two glazed and one gauged shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for frame (i) Top and verticals 92 x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) 'A' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick (iii) 'H' section 41 x 20 x 1.10 mm thick
M&L for 4.0 mm thick figured glass, ordinary quality and glazing with aluminium snap beading of any size in each panes complete all as specified and directed by Engineer - in - Charge.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or Fe -165 complete all as specified and directed by Engineer - in - Charge.
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engineer - in - Charge.
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of red oxide & finish with two coats of synthetic enamel paint ordinary tint complete all as specified and directed by Engr-in-charge.
S&F for stainless steel curtain rods, standrad quality, not less than 25mm dia with heads , etc. complete all as specified and directed by Engr-in-charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engr-in-charge.
S&F in repair brass hat pegs, solid body, 125 mm to 175 mm (4 legs) complete all as specified and directed by Engr-in-charge.
S&F in repair towel rails 20mm dia 600mm long brass chromium plated superior quality brass chromium plated fancy type complete all as specified and directed by Engr-in-charge.
S&F in repair chromium plated fancy type soap dish complete all as specified and directed by Engineer-in-Charge
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests (excl flushing cistern) but including CI 'P' trap set in and including concrete complete all as specified and directed by Engr-in-charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engr-in-charge.
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling/trap complete all as specified and directed by Engr-in-charge.
S&F in repair pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed by Engr-in-charge. Note : Wt should not be less than 450 gms
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup complete all as specified and directed by Engr-in-charge.
S&F in repair CP brass stop valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) complete all as specified and directed by Engr-in-charge.
S&F in repair, shower rose, 125 mm size, brass chromium plated with sweivel joint complete all as specified and directed by Engr-in-charge.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engr-in-charge.
Dismantling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site all as specified and directed.
S&F for Rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I. complete all as specified and directed by Engr-in-charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified and as approved by GE/Engineer-in-Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engr-in-charge.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified and directed by Engr-in-charge.
,---ditto--- all as per srl item No 84 above but 20mm dia pipe complete all as specified and directed by Engr-in-charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engr-in-charge.
,---ditto--- all as per srl item No 86 above but 15mm dia pipe fixing only complete all as specified and directed by Engr-in-charge.
,---ditto--- all as per srl item No 86 above but 20mm dia pipe complete all as specified and directed by Engr-in-charge.
,---ditto--- all as per srl item No 86 abovev but 20mm dia pipe fixing only complete all as specified and directed by Engr-in-charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required upto 100mm dia complete all as specified and as directed by engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning soft soil, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store complete all as specified and directed by Engr-in-charge. (measured over alll as fixed along the cente line over fittings and accessories)
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engr-in-charge.
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engr-in-charge.
S&F in repair stainless steel kitchen plate rack made out with 1mm thick sheet of size 24" x 24" x 10" including taking down existing wooden plate rack complete all as specified and directed by Engineer-in-Charge.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 100 mm bore spun cast iron pipe waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing with necessary coupling complete all as specified & directed by Engr-in-charge.
S&F in repair 100mm bore spun cast iron type door T equal/uneqal branch pieces (any radius) diminishing pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-charge.
S&F in repair 100mm bore spun cast iron type plain bends (any radius) dimining pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engr-in-Charge.
Supply & fixing 75 mm bore spun cast iron pipe waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing with necessary coupling complete all as specified & directed by Engr-in-charge.
S&F in repairs spun cast iron type P trap/CPWD floor trap 75 mm bore with CP grating including jointing to waste pipe fixed with necessary coupling arrangement complete all as specified and directed by Engineer-in-charge.
S&F in repair 75mm bore spun cast iron type door T equal/uneqal branch pieces (any radius) diminishing pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-charge.
S&F in repair 75mm bore spuncast iron type plain bends (any radius) dimining pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engr-in-Charge.
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors complete all as specified and directed by Engineer-in-charge.
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with over 25mm thick Fazilka sand cushion all as specified and directed. (Sand will be measured and paid seperatly)
Suply only Fine aggregate (sand) for Cushioning (Fazilka sand) complete all as specified and directed by Engineer-in-charge
M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-charge
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in benching / haunchig of manholes including forming channels, coping and the like including weatjeromg.slightly rounded or chamfered angles and throating including necessary formwork etc. complete all as specified and directed by Engineer-in-charge
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-charge
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-Charge
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and conforming to Fe 410 -W (Gde- E- 250) quality- A.
M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conoforming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1-using 20mm graded stone aggregrate in beams all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20mm graded stone aggregrate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, pillers etc.; all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20mm graded stone aggregrate in columns, pillers etc.; all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finish surface of concrete flat all as specified and directed.
M&L for formwork to sides of pillars, columns etc; fair finish surface of concrete square, rectangular or polygonal all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. fair finish surface of concrete flat all as specified and directed.
S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Surface excavation N.exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones size 300mm x 300mm x 100mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and directed
Supply only galvanised mild steel chain link fencing of 3.15 mm dia wire, 100mm x 100 mm mesh size complete all as specified and directed by Engineer-in-Charge. Note:- The weight of chain link fencing shall be measured as per findings of board concured by Accepting Officer.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straing bolts, round bars etc. including provision of binding wire complete all as specified and directed by Engineer-in-Charge. Note:- Supply only line wire mesh and round bar shall be measured and paid separately under appropriate item of this schedule.
Supply and fixing mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivetting etc. and similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed Note:- (i) Flat iron for securing wire mesh and machine made screw bolt 10mm dia exceeding 5cm and not exceeding 10cm long is to measured in this item.
Supply only 10mm dia round bar as in line wire for chain link fencing including bending, cranking etc complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry on roof, and cut and polished over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for 19 mm thick, Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
S & F 2 mm thick fibre glass reinforced translucent plain sheeting with 15 cm side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
E/M PORTION Taking down carefully copper/aluminium point wiring (light, socket or power) complete with all fittings and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed by Engr-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engr-in-Charge.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engr-in-Charge.
M&L for concealed Point wiring with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with modular sheet top cover of required module for mounting switches, sockets etc complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour for One Light point controlled by one, one way switch complete all as specified and directed by Engr-in-Charge. .
,--ditto--- all as per Serial item No 133 above, but for One ceiling/exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 133 above, but for One bell/buzzer point controlled by one bell push complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 133 above, but for One 3 pin 5 amps switch socket outlet point on same board with other switches complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 133 above, but for One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 133 above, but for two way point controlled by two way switch complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 133 above, but for wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for 15 amps power point complete all as specified and directed by Engr-in-Charge.
Supply and fix piano switch flush button single pole one way 5/6 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix socket outlet 2 in 1, 2/3 pin 6 amp flush type 250 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix socket outlet 2 in 1, 3 pin 5 amp and 15 amp flush type 240 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano switch 15 amp flush type 240 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano switch flush button single pole two way 6 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano bell push flush button single pole 6 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix bell AC 240V complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge.
Supply and fix lamp holder insulated body with back plate for angle/batten fitting with LED of 09 watt complete all as specified and directed by Engr-in-Charge.
Material & Labour for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable with and including 6 Sqmm copper green colour earth wire complete all as specified and directed by Engr-in-Charge. NOTE - Two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
S & F batton integrated LED light fitting 1 x 20 W integral sleek polycarobonate LED Channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVC blocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting incl taking out old one complete all as specified and directed by Engineer-in-Charge. Note : (i) With lumen efficiency in excess of 100 lumens par watt and driver efficiency>85% (with pf>0.95) (ii) CRI>80
S&F exhaust fans, steel body, heavy duty AC single phase 230V of size 300m sweep with blades and frames and louvers after dismentalling old items deposite to MES store yard complete all as specified and directed by Engr-in-Charge.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep, ISI mark, min air delivery 210 CFM with service value 6.00 BEE, 5 star rated, energy efficient with bushless direct current motor(BLDC) after dismantling old item deposit to MES store complete all as specified and directed by Engr-in-Charge.
S&F electric water heater, storage type steel body with copper tank and heating element upto 2KW capacity 25 liter, BEE 5 star rated ,energy efficient complete with all accessories such as safety valve, thermostate, NRV, connection piece etc after dismantling old items deposit to MES store complete all as specified and directed by Engr-in-Charge.
Supply and fix fresh air fan 230 mm sweep 240 vot 50 Hz plastic body complete with louvers and including making hole in wall fixing complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure single pole and neutral with 02 Pin and earth plug and socket complete with 01 single pole 20 Amps 240volts, MCB complete incl necessary fixing arrangement and all incoming and outgoing electric connection complete all as specified and directed by Engr-in-Charge. .
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15mm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvaniseed iron or steel and thimbles and other end of the earth wire connected to earthing test point and prortected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B1 and CI cover with frame all as shown in electrical plate No 3 of MES Schedule Part I of SSR 2009 complete all as specified and directed by Engr-in-Charge. Note : (i) 20mm dia GI pipe for watering to be provided with a socket and plug and should be 10cms above ground level (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber (iii) GI wire upto DBs earth connection is included in this item (iv) Water pipe should be provided in slanting position.
Supply and fix verticle MCB DB TPN 415 volts 4 way with 200 Amps rated busbar flush/surface mounting double door including complete all as specified and directed by Engr-in-Charge.
Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MCB SPN 6-32 amp, 240 volt 10KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MCB SP 6-32 amp, 240 volt 10KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MCB SP 40 amp, 240 volt 10KA complete all as specified and directed by Engr-in-Charge.
M&L for repair to door hinges of MS housing of size0.9x0.6m including necessary welding and painting the panel with two coats of synthetic enamel paint ordinary tint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
ram rattan dass aggarwal
M/s Karan Builders
PAREEK AND COMPANY
M/S Shree Ram Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .