| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹26.6 L+₹1.5 L (6.09%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC Not L1 Bidder |
Tender Value
₹39.6 L
EMD Value
₹79,300
Closing Date
9 Jan 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINT OF MISC ITEMS/EQUIPTMENTS OF VARIOUS IN THE AOR OF AGE U WS NO III UNDER GE U WATER SUPPLY DELHI CANTT 10
2023_MES_632326_1
GE/WS/IFA-97/Token-55 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹79,300
Yes
29 Jan 2024
12 Dec 2023
11 Jan 2024
12 Dec 2023
9 Jan 2024
26 Dec 2023
Amount
Taking down old unserviceable point wiring from existing conduit ( light fan , socket or powder) complete such as switches, ceiling rose, pendent holder and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc complete all as complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box (Make : Schneider Elect/Legrand Mosaic/Anchor Ave) of suitable size for fixing modular switches/sockets/fan regulator etc complete all as specified and directed for the following :- (Note : The cost of modular type Metal boxes and modular accessories like cover plates will be included in quoted rate.)
one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push.
one socket outet point 5 amps on the same board.
one socket outet point 5 amps on the independent board.
All as per item no. 2 here in before but One 3 pin socket outlet. 15 amps, independent with 4 sq mm copper FRLS wire with 4 Sqmm FRLS copper earth wire
Material and labour in replacement for Sub main wiring with 2 run of 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB/digital water meter complete all as directed. Note : (i) The conduit and conduit accessories shall be measured and paid as one unit. (ii) The cost of earth wire is included in the quoated rates.
Material and labour in replacement for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed. Note : (i) The conduit and conduit accessories shall be measured and paid as one unit. (ii) The cost of earth wire is included in the quoated rates.
Material and labour in replacement for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed. (Note:- (i) The conduit and conduit accessories shall be measured and paid as one unit. (ii) The cost of earth wire is included in the quoated rates.
Supply & fixing in replacement of switch piano, flush type single pole 1 way, 6 Amps complete all as specified and directed.
Supply & fixing in replacement of switch piano, flush type single pole 1 way, 15 Amps complete all as specified and directed.
Supply & fixing in replacement of socket outlet 2 in 1, 3 pin 6 Amps complete all as specified and directed.
Supply & fixing in replacement of socket outlet, 2 in 1, 3 pin 6 and 16 Amps complete all as specified and directed.
Supply & fixing in replacement of Fan regulator step type, flush type complete all as specified and directed.
Supply and fixing in replacement of Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size & MS box of suitable size complete all as specified and directed.
Supply and fixing in replacement of electric bell of DINGDONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as specified and directed.
Supply and fixing in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed.
Supply and fixing in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed.
Supply and fixing in replacement of MCB C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 6 to 32 Amps complete all as specified and directed.
All as item no 16 here in before but of 40 to 63 amps capacity.
All as item no16 here in before but of 40 to 63 amps capacity and SPN type.
Supply and fixing in replacement of sheet metal enclosure (Industrial type DB ) complete including single pole and neutral with two pin earth plug and socket complete with one MCB SP C Curve type of capacity 32 Amp 10 KA complete all as specified and directed.
S & F Rigid non metallic PVC conduit ( ISI marked) 2 mm thick 15 mm dia (external) inclusive of MS junction/terminal boxes for sub main/telephone wiring / TV connection inclusive of all fittings such as tees, bends,, elbow, reducers, bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and fixing in replacement LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in replacement Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps complete all as specified and direcred .
Supply and fixing in replacement of sheet metal enclosure for DBs when MCBs to be used 2 way with out busbar complete all as specified and direcred .
Supply and fixing in replacement of exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and direcred .
Supply and fixing in replacement of exhaust fan, steel body AC single Phase 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and direcred .
Supply and fixing in replacement of ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and direcred .
Supply and fixing in replacement of wall mounting air circulator fan 230 V, 50 Hz single phase oscillating type 450 mm sweep complete all as specified and direcred .
Taking dwn the existing ceiling fan, dismentling, opening the winding, cleaning the slot and rewinding the fan with existing gauge of super enamelled copper winding wire including replacement of worn out bush, bearing, clamp hooks, capacitor complete all as specified and directed.
S&F in replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including fixing arrangments complete all as specified and directed.
S&F in replacement of building security LED light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Material and labour in replacement for submain wiring complete with three run of 2x1.5 sq. mm + 1x1.5 sq. mm earth wire (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, in and including PVC conduit of size 20 mm dia, medium grade and conduit fitting such as tees, bends, elbow, reducers etc complete all as specified and directed. Note : (The three run of 1.5 sqmm with PVC conduit pipe of 20 mm dia shall be measured and paid as one unit.)
Disconnecting and taking out oldunserviceable Lt under ground cable of any type, any description from trenches/walls/ducts/floor of following sizes complete all as specified and directed.
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
185 Sqmm 3.5 Core
(Note for ser item No 4 to 34:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
Material and labour for laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade suitable for laid in duct / trench / along pole/wall etc including making connection complete all as specified and directed.
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
185 Sqmm 3.5 Core
Note :- (i) The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. (ii) The excavation, earth work, sand cushioning and brick protection etc will be measured and paid separately under respective items.
Excavation in trenches in any type of soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed. (Note - Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed.
S & F in repalcement of capacitor 2/3.15 mfd AC 415 volts 50 Hz complete all as specified and directed
S & F in repalcement of capacitor 4 mfd AC 415 volts 50 Hz complete all as specified and directed
S & F in repalcement of ball bearing for ceiling fan /exhaust fan any size any make complete all as specified and directed
S & F in repalcement of gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep complete all as specified and directed
S & F in repalcement of Twin core flexible wire of size 1.00 Sqmm complete all as specified and directed
S & F in repalcement Replacement of exhaust fan lovurs as per existing sample gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep complete all as specified and directed
Supply and fix in repair wall mounting automatic transfer switch 415 V 50Hz of 63 Amps complete all as specified and directed
Supply and fixing LED bulb of 12 watt complete all as specified and directed.
S&F in repair of LED driver suitable for LED street light fitting 90 watts as per existing make and model complete all as specified and directed
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick busied directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. (i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .
(ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
Ditto, but using galvanised iron strip 32×6mm as earthing lead complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Ditto, but 32x6mm galvanised iron strip complete all as specified and directed.
(Note for ser item No 40 to 53:- Old U/s material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
Dismantling of GI light bracket 40mm dia of any description complete all as specified and directed.
S&F GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers, Clamps (02 sets) of suitable size complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and directed at site by the Engr-in-Charge. Note:- (i) Flanged joints and rubber packing complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
100 mm bore
150 mm bore
200 mm bore
Testing of drinking water collected from local source (bore wells /shallow wells) in the area of AGE (U) W/S No.III and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note :- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and from transportation charges for collection of samples from source (sump, bore & shallow wells)
Dismantling of Old unserviceable LT Panel of any description and depositing to MES Store yard complete all as specified and directed.
Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side 415 Volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing of the following complete all as specified and directed : Incoming :- (a) MCCB 400 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 Nos. (b) Changeover Switches 4 pole 415 volts 400 Amps - 01 No Outgoing :- (a) MCCB 100 Amp, Three pole, 415 Volts, 50 HZ 25 KA -03 Nos.
Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side 415 Volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing of the following complete all as specified and directed : Incoming :- (a) MCCB 200 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 Nos. (b) Changeover Switches 4 pole 415 volts 400 Amps - 01 No Outgoing :- (a) MCCB 63 Amp, Three pole, 415 Volts, 50 HZ 16 KA -03 Nos.
Disconnecting the electric connection, dismantling and taking out/down centrifugal pumps of capacity of 15 HP to 50 HP and installation at new position/location with copper cable of required size for connection upto starter panel including foundation and fixing arrangement complete all as specified and directed. (Note : Cost of foundation, connecting copper cable and fixing arrangement including vibration pad included in the quoted rate.)
Supply and fixing soft starter suitable for 40 HP pumps 75 Amps 208 to 609 Volts in SS enclosures alongwith cooling arrangement for soft starter including taking out old unserviceable starter and deposited to MES Store yard complete all as specified and directed.
Supply and fixing soft starter suitable for 75 HP pumps 140 Amps, 208 to 609 Volts in SS enclosures alongwith cooling arrangement for soft starter including taking out old unserviceable starter and deposited to MES Store yard complete all as specified and directed
Supply and fixing in replacement FRLS PVC insulated industrial grade copper conductor wire of following size, 1100 volts complete all as specified and as directed.
10.00 sqmm, single core
16.00 sqmm, single core
25.00 sqmm, single core
(Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight in 'KG' shall be taken into account and attach with RAR/F Bill)
Deven Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .