Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-Finance | L1 | Accepted-Finance ACCEPT | |
| 2 | L2₹2.4 L+₹22,930 (10.5%)Rejected-Finance | L2 | Rejected-Finance REJECT | |
| 3 | L3₹2.6 L+₹45,360 (20.8%)Rejected-Finance | L3 | Rejected-Finance REJECT |
| Sl No | Description | Qty | Unit | MODERN REFRIGERATION AND ELECTRICAL WORKS L3 | ELECTRIC REFRIGERATION L2 | IDEAL INCORPORATE SOLUTION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of 2.0TR capacity concealed type split Air-conditioner of rated cooling capacity of 24000 BTU/hr with 1nos rotary compressor, 1nos. IDU of rated power supply 230V-1 ph-50Hz, 1no.ODU of rated power supply 230V-1ph, 50Hz, R 410A Refrigerant. Air flow/per IDU:- 800CFM. The indoor unit should be compatible with wired LCD remote controller with alphabetic error display like HP, LP,SPPR [Make: Hitachi/Carrier/Voltas or equivalent make or model as approved by E.I.C]. (NS) | 2 | Each | 74,200 ₹1,48,400 | 69,960 ₹1,39,920 | 65,340 ₹1,30,680 Lowest |
| 2.00Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC | ||||||
| 2.01 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 1 | Each | 52,600 ₹52,600 | 48,500 ₹48,500 | 47,700 ₹47,700 Lowest |
| 3.00 | Installation, testing, & commissioning of the above -said split ACs incl. supply & fixing required angle iron structure on wall for placing outdoor unit & mending good the damages as per direction of E.I.C. | 1 | Each | 3,550 ₹3,550 | 3,000 ₹3,000 | 2,200 ₹2,200 Lowest |
| 4.00 | Installation, testing & commissioning of the above said split type concealed Air Conditioner of 2.0 TR capacity. The indoor unit must be supported by structure made of 25x25x5 mm angle and tie rod, fastnut etc. inld neccy. mending works as per direction of EIC. | 2 | Each | 4,000 ₹8,000 | 3,300 ₹6,600 | 2,220 ₹4,440 Lowest |
| 5.00 | Supply & Installation of Extra Add - on items - HVAC grade 5/8" (for suction) & 1/4" (for discharge) copper refrigerant pipe with 9 mm thick nitrile rubber insulation including shaddle, screw, insulation tape, fastner etc for above AC machine as per direction of EIC. | 30 | Mtr. | 1,200 ₹36,000 | 1,050 ₹31,500 | 900 ₹27,000 Lowest |
| 6.00 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 30 | Mtr. | 150 ₹4,500 | 100 ₹3,000 | 70 ₹2,100 Lowest |
| 7.00 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm, 3/4 core copper cable (FRLS type) | 30 | Mtr. | 200 ₹6,000 | 150 ₹4,500 | 119 ₹3,570 Lowest |
| 8.00 | Supply & charging of R410A refrigerant. | 4 | Kg | 1,000 ₹4,000 | 900 ₹3,600 Lowest | - |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
28 Jul 2026, 11:00 amClosed
Assistant Engineer, Howrah Electrical SUb Division
Howrah Court Campus
SITC of air Conditioner machine at CJM Eglach, Howrah Court Premises.
2026_WBPWD_5016722_1
WBPWD/AE/HESD/e-NIQ-13/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Howrah Court Campus
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,500
19 Aug 2026
13 Jul 2026
30 Jul 2026
13 Jul 2026
28 Jul 2026
13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of 2.0TR capacity concealed type split Air-conditioner of rated cooling capacity of 24000 BTU/hr with 1nos rotary compressor, 1nos. IDU of rated power supply 230V-1 ph-50Hz, 1no.ODU of rated power supply 230V-1ph, 50Hz, R 410A Refrigerant. Air flow/per IDU:- 800CFM. The indoor unit should be compatible with wired LCD remote controller with alphabetic error display like HP, LP,SPPR [Make: Hitachi/Carrier/Voltas or equivalent make or model as approved by E.I.C]. (NS) | 2 | Each | 1.25 | ₹2.5 |
| 2Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC | |||||
| 2.01 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 1 | Each | - | - |
| 3 | Installation, testing, & commissioning of the above -said split ACs incl. supply & fixing required angle iron structure on wall for placing outdoor unit & mending good the damages as per direction of E.I.C. | 1 | Each | 100 | ₹100 |
| 4 | Installation, testing & commissioning of the above said split type concealed Air Conditioner of 2.0 TR capacity. The indoor unit must be supported by structure made of 25x25x5 mm angle and tie rod, fastnut etc. inld neccy. mending works as per direction of EIC. | 2 | Each | 11 | ₹22 |
| 5 | Supply & Installation of Extra Add - on items - HVAC grade 5/8" (for suction) & 1/4" (for discharge) copper refrigerant pipe with 9 mm thick nitrile rubber insulation including shaddle, screw, insulation tape, fastner etc for above AC machine as per direction of EIC. | 30 | Mtr. | 10 | ₹300 |
| 6 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 30 | Mtr. | 11 | ₹330 |
| 7 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm, 3/4 core copper cable (FRLS type) | 30 | Mtr. | 1.25 | ₹37.5 |
| 8 | Supply & charging of R410A refrigerant. | 4 | Kg | 1.25 | ₹5 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_5086417.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .