| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹29.4 L+₹4.0 L (15.5%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹33.0 L+₹7.5 L (29.5%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹36.0 L+₹10.5 L (41.3%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Oct 2024, 6:00 pmClosed
Garrison Engineer Belgaum
Garrison Engineer Belgaum Laxmi Tek,Camp,Belgaum
MAINTENANCE, REPAIR AND REPLACEMENT OF DIFFERENT TYPE OF VALVES INCLUDING REPAIR TO DIFFERENT SIZE OF SLUICE VALVE CHAMBERS UNDER GE BELGAUM.
2024_MES_670517_1
8551/E8
Open Tender
Civil Works
Item Rate
240 days
Belgaum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Belgaum
₹60,000
Yes
18 Oct 2024
2 Sept 2024
5 Oct 2024
2 Sept 2024
3 Oct 2024
16 Sept 2024
Amount
NOTE :THE ITEMS MENTIONED BELOW SHALL BE OF SPECIALIZED IN NATURE AND EXECUTED UNDER THE SUPERVISION AND GUIDELINES FROM OEM.THE ENTIRE WORK ONCE COMPLETED WILL BE INSPECTED AND CERTIFIED BY THE REP OF OEM FOR FUNCTIONAL ASPECTS OF ITEMS INSTALLED AT SITE.COMPLETION CERTIFICATE WILL BE ISSUED BY THE GE ONLY AFTER SATISFACTORY COMMISSIONING REPORT RECEIVED FROM OEM.THE RATE QUOTED BY THE CONTRACTOR FOR THE ITEM NOS : 1.01 TO 1.27 ,2 TO 8 ,13 TO 15 SHALL BE DEEMED TO INCLUDE THE ABOVE PROVISIONS.
Relay with base 4 C/O / 24 V DC, Note : Make: OMRON/SALZER/SCHNEIDER/IDEC/LEONE
Relay with base 4 C/O /240 V DC Note : Make: OMRON/SALZER/SCHNEIDER/IDEC/LEONE
LED Indicator Colour/Red /yellow/Green.Supply Voltage: 230 V Make: SCHNEIDER/ESBEE/TELEMECHANIC /L&T
Programmable Logic Controller, Power supply: 24VDC (-15% to ~ 20%) Inrush current: Max. 2.2A@24VDC Power consumption: 6 W Operation /storage:Operation: 0ºC ~ 55ºC (temperature); 5 ~ 95% (humidity); Pollution degree 2 Storage: -25ºC ~ 70ºC (temperature); 5 ~ 95% (humidity) Make: : Delta/Mitsubishi/Siemen/ABB/UNITRONIC
Analogue module for Programmable Logic Controller Input voltage (±10%): 24VDC, 5mA Note : Make: Delta/Mitsubishi/Siemens/ABB/UNITRONIC
D/O module for Programmable Logic Controller, Input voltage (±10%): 24VDC, 5mA Note : Make: Delta/Mitsubishi/Siemens/ABB/UNITRONIC
D/I module for Programmable Logic Controller, Input voltage (±10%): 24VDC, 5mA Make: Delta/Mitsubishi/Siemen/ABB/UNITRONIC
HMI for Programmable Logic Controller, Size: 7'' RAM: 16 MB, Flash Memory:16 MB Note : Make: Renu/ Mitsubishi/Siemen
Push button with LED Indicator - 240 V A.C. Colour/Red/yellow/Green Note : Make: SCHNEIDER/ESBEE/TELEMECHANIC /L&T
Lan based communication Ethernet Switch –16 port 100MbPS switch Make : Cisco, Dlink,
Rack Mountable LIU with the following specifications:- Rack Mountable 12 Port Unloaded LIU, Plastic base, Winding Panel – Plastic Cable Plug – Rubber for minimum 2 cable entries, Adaptor Panel Aluminium 1.5 mm thick 2 fiber spools built in for 900 um tight buffered fibre storing Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptor Make : CCL Opto, R&M, Sterlite
SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length Size 0.9mm dia Insertion Loss <=0.2 db, max 0.3 db Return Loss PC>=45dB, UPC>=50dB, APC>=60dB Connector Ferrule Ceramic Apex Offset <50um Fiber Height +-100nm End Face Radius of Curvature 7mm<R<25mm Repeatability <=0.2 dB 1,000 times mating cycles Working Temp -40deg C to +85 deg C Make : Dlink,CCL, R&M
SC Simplex Coupler/Adaptor Insertion Loss <=0.2 dB for Zirconia Sleeve Sleeve/Ferrule Withdrawl Force 2.0N to 5.9N Make : Dlink,CCL, R&M
Adaptor Panel 6 port adaptor Panel for SC Adaptors Make :Dlink,CCL, R&M
SC-SM-Simplex Pigtail of suitable length Insertion Loss <=0.2 db, max 0.3 db Return Loss PC>=45dB, UPC>=50dB, APC>=60dB Connector Ferrule Ceramic Apex Offset <50um Fiber Height +-100nm End Face Radius of Curvature 7mm<R<25mm Repeatability <=0.2 dB 1,000 times mating cycles Working Temp -40deg C to +85 deg C Make :Dlink,CCL, R&M
CAT6 UTP 24 AWG Patch Cord of suitable length, Plug 30U snag less Make : Dlink,CCL, R&M
Indoor type Panel made out of 1.6 mm thick CRCA sheet duly powder coated. Make: Impulse/RKOM/ICS
PLC programming as site requirment and integration.
9 DB Antenna For GPRS Modem as per sample.
MCB 4P 32A. C series ,10 KA Make: Indo Asian/Schneider/L&T
MCB 2P 6A C series ,10 KA Make: Indo Asian/Schneider/L&T
SMPS AC Input Voltage: 170 ~ 270 V. Stable Output Voltage (V DC): 24. Output Current (Amp): 5. Output Power (Watt): 120. Make: NHP/Schneider/Telemecaniqee
Current transducers / energy meters with inbult mod bus communication port Make : RISHABH/CONZERV/L&T/Selec/secure
Surge Protection device suitable for 230V incoming supply
Supply, Install, Test and Commissioning of Float type Point Level Sensor with the following specifications : Type: Magnetic Magnet: Ring type Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon Make: Rkom/Techtrol/ Sapcon
Supply, Install Test and Commissioning of Motor Actuated Butterfly Valve of size 100 mm dia consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos of limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Actuator Make : Rkom / ICS / Realtork / Emtork Butterfly Valve Make : L&T / Normex / Leader / Zoloto Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In Built Serial/USB communication Port In Built data logger with memory In built SC Card Space Heater Mounting : Direct Make: EMTORK / HASEL HOFENER / REALTORK
Supply, Install , Test and Commissioning of Motor Actuated Butterfly Valve of size 150 mm dia, consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos of limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Actuator Make : Rkom / ICS / Realtork / Emtork Butterfly Valve Make : L&T / Normex / Leader / Zoloto Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In Built Serial/USB communication Port In Built data logger with memory In built SC Card Space Heater Mounting : Direct Make: EMTORK / HASEL HOFENER / REALTORK
Supply, Install , Test and Commissioning of Motor Actuated Butterfly Valve of size 200 mm dia, consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos of limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Actuator Make : Rkom / ICS / Realtork / Emtork Butterfly Valve Make : L&T / Normex / Leader / Zoloto Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In Built Serial/USB communication Port In Built data logger with memory In built SC Card Space Heater Mounting : Direct Make: EMTORK / HASEL HOFENER / REALTORK
Supply, Install , Test and Commissioning of Motor Actuated Butterfly Valve of size 400 mm dia, consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos of limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Actuator Make : Rkom / ICS / Realtork / Emtork Butterfly Valve Make : L&T / Normex / Leader / Zoloto Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In Built Serial/USB communication Port In Built data logger with memory In built SC Card Space Heater Mounting : Direct Make: EMTORK / HASEL HOFENER / REALTORK
Supply, Install, Test and Commissioning of Pressure transmitter with the following specification including necessary power pack for supply of DC : Power supply: 10-36 V DC Process connection: G ½ “ Enclosure: weather proof IP 65 Process temperature: -30 to 120 celcius complete all as specified and as directed. Make: Danfoss/ Siemen/ E+H/Indfoss
Supply, Install Test and Commissioning of Solenoid / motorised valve suitable for 25mm GI pipe for priming of pump including suitable bypass arrangement using 25 mm. gate / ball valve with necessary GI fittings with following specifications: Size: 25 mm dia Pressure rating: 6 kg / sq. cm. Make: Johnson control/ AVCON/Honeywell
Supply, Install, Test and Commissioning of Solenoid valve suitable for 10mm GI pipe for priming of pump including bypass arrangement using 10 mm. gate / ball valve with necessary GI fittings with following Specifications: Size: 10 mm dia Pressure rating: 6 kg / sq. cm. Normally closed complete all as specified and as directed. Make: Johnson control/ AVCON/Honeywell
Supply and fix on wall / drawing through existing pipe 2 x 1.5 sq.mm.FRLS PVC insulated and sheathed armoured copper conductor cable with suitable size of saddles etc complete all as specified and as directed. Note : Make: POLYCAB/ Havells/FINOLEX
Supply and fix on wall / drawing through existing pipe 4 x 1.5 sq.mm.FRLS PVC insulated and sheathed armoured copper conductor cable with suitable size of saddles etc complete all as specified and as directed. Note : Make: POLYCAB/Havells/FINOLEX
Supply and fix on wall / drawing through existing pipe 6 x 1.5 sq.mm.FRLS PVC insulated and sheathed armoured copper conductor cable with suitable size of saddles etc complete all as specified and as directed. Note : Make: POLYCAB/ Havells/FINOLEX
Supply and fix double compression steel gland of 16 mm size complete all as specified and as directed.(ISI MARKED)
Material and labour for Making Priming arrangements to the pump including necessary cutting and inserting the existing pipe line for upto 25 mm dia and Provision of new Rotational moulded polyethylene water storage tanks ,Double layered (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR Part- I of 1000 Litre capacity for priming purpose complete all as specified and as directed.Note :Make of Water Tank :Sintex/Polycon/Infra(ISI MARKED)
Supply and fix Gun metal Gate valve of 25 mm dia with iron wheel head/handle screwed both ends for iron pipe and fixed complete all as specified and as directed.Note :Make :Leader/Kartar/Zoloto(ISI MARKED)
Supply and fix Non Return Valve of 25 mm dia screwed both ends for iron pipe and fixed complete all as specified and as directed.Note :Make :Leader/Kartar/Zoloto(ISI MARKED)
Material and labour for Galvanised iron Steel water tubing 25 mm dia, medium grade including all necessary elbows, tees, short piece, sockets, reducers, etc laid in trenches or fixed on wall complete all as specified and as directed.Note :Make :TATA/Prakash Surya/Jindal (ISI MARKED)
Material and labour for Ball Valve high pressure of PTMT with epoxy coated Aluminium rod And high density plastic ball screwed for iron pipe and fixed (Minimum weight ;455 gms ) of size 25 mm diacomplete all as specified and as directed.Note Make :Prayag/M/S Shakthi Industries (ISI MARKED)
Material and labour for Fabrication works with MS pipe of size 100 mm dia, 6 mm thick, carefully cutting into pieces and welding work with suitable flange on the both side of maximum length of pipe 300 mm fixed with MS nut bolt, double washer, etc as required complete all as specified and as directed.
Material and labour for Fabrication works with MS pipe of size 150 mm dia, 6 mm thick, carefully cutting into pieces and welding work with suitable flange on the both side of maximum length of pipe 300 mm fixed with MS nut bolt, double washer, etc as required complete all as specified and as directed.
Material and labour for Fabrication works with MS pipe of size 200 mm dia, 6 mm thick, carefully cutting into pieces and welding work with suitable flange on the both side of maximum length of pipe 300 mm fixed with MS nut bolt, double washer, etc as required complete all as specified and as directed.
Material and labour for Fabrication works with MS pipe of size 400 mm dia, 6 mm thick, carefully cutting into pieces and welding work with suitable flange on the both side of maximum length of pipe 300 mm fixed with MS nut bolt, double washer, etc as required complete all as specified and as directed.
Material and labour for addition/alteration works with water inlet/outlet line of pump set of any capacity by cutting the existing GI/CI/DI pipe of any dia including necessary welding works to accommodate new lines/equipment of the system complete all as specified and as directed.
Supply and fix G I Cable Tray superior quality of size 150 mm x 40 mm ,18 gauge thick including cost of the all fixing arrangements as required as per site condition complete all as specified and as directed.(ISI MARKED)
Supply and lay Double wall corrugated high density polymer (SDR 17) pipe of ISI marked 63 mm outer dia and 50mm inner dia as in cable protection fixed to poles with necessary suitable MS clamps, bolts, nuts, washers, couplers,bends,end caps etc laid in trenches/ roads crossings etc complete all as specified and as directed.Make: KELTRON/REX/DURALINE
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation, laying pipe etc.. and getting out inhard/dense soil complete all as specified and as directed.
Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position for panel foundation or sluice valve chember, etc and removable of rubbish off the premises and serviceable items taken as credit complete all as specified and as directed.
Material and labour for Provding Plain cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate as in foundation of valve chamber filling mass concrete etc including necessary steel form work complete all as specified and as directed.
Material and labour for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for Rendering 10 mm thick in cement mortar on fair surfaces of brick work or concrete surface in cement plaster (1:3) ,surface finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for Water testing as per IS 10500:2012 for the locations every month : (i) Lakshmi tek pump house, (ii) Parade ground road pump house, (iii) Fort Area (iv) Nagzeera Pump House from Environmental Health and Safety Research and Development Centre or approved NABL Lab and submit the water testing certificate in original to Engg in Charge on or before te last working day of every monthcomplete all as specified and as directed.
Material and labour for Water testing as per direction of Engg-in-charge every month from Environmental Health and Safety Research and Development Centre or approved NABL Lab and submit the water testing certificate in original to Engg in Charge on or before te last working day of every month at (a) STP water before filtering (b) STP water after filtering complete all as specified and as directed.
Material and labour for Rolled Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering doors, slice valve pit cover and frame, sheet, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing confirming to Fe 290 E -165 including Preparation of new steel surface of any description and applying two coats of metalic paint over a coat of metalic primer etc complete all as specified and as directed.
Dismatling of old unserviceable sluice valve of size 100 mm dia with nut bolt and washer and taken as credit complete all as specified and as directed.
Dismatling of old unserviceable sluice valve of size 150 mm dia with nut bolt and washer and taken as credit complete all as specified and as directed.
Dismatling of old unserviceable sluice valve of size 200 mm dia with nut bolt and washer and taken as credit complete all as specified and as directed.
Dismatling of old unserviceable sluice valve of size 400 mm dia with nut bolt and washer and taken as credit complete all as specified and as directed.
Green Ray Enterprises (BID ID -3105731)
ELSOL ENGINEERS (BID ID -3106945)
M/s. VIJAY ELECTRICALS (BID ID -3108041)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .