GE Babina
GE Babina PIN-284401
SPL REPAIR OF BLDG NO P-40 (QTR NO 1 TO 8) OR MD ACCN AT BHAGAT ENCLAVE AT 7 MECH INF UNDER AGE BR-II ,GE BABINA
2026_MES_794167_1
8617/E8
Open Tender
Civil Works
Item Rate
270 days
GE Babina
As per tender documents
7 documents required · 7 mandatory
₹500
GE Babina
₹96,760
Yes
15 Oct 2026
15 Oct 2026
12 Nov 2026
15 Oct 2026
6 Nov 2026
30 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of existing roof treatment of any description i.e APP membrane, brick tiling incl cement mortar OR concrete padding and open up top layer of roof slab (any type) complete removal of debris from site complete all as directed by Engineer in Charge.
Note :- The work is required to be carried out at roof for single/double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof for site inspection. The rates quoted shall deemed to be included for these items . | 8 | Cum | 100 | ₹800 |
| - | M&L for wire brushing and cleaning top surface of roof slab, flashing and junction of parapet etc including picking, sweeping cleaning and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as directed by Engineer in Charge. | 200 | Sqm | 10 | ₹2,000 |
| - | M&L for widening the cracks in existing roof or teracing , cleaning out , wetting and grouting with polymer mortar (cement : sand in 1;4) admixed with crack seal as per manufectured direction complete all as directed by Engineer in Charge. | 200 | Sqm | 10 | ₹2,000 |
| - | M&L for one coat of Cement slurry admixed with acrylic bonding compound SBR Latex of approved make as to be used for bonding of new concrete/ mortar to old surface.(will be applied and as per direction of manufacturer ) complete all as directed by Engineer in Charge. | 200 | Sqm | 10 | ₹2,000 |
| - | M&L for 40mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with polymer modified repair mortar (SBR Latex liquid polymer as per manufacturer direction ) and finishing the surface even and smooth using extra cement as in roof padding to receive roof treatment complete all as specified and directed.
Note :- (SBR) Latex liquid polymer will be measured and paid seperately. | 8 | Cum | 10 | ₹80 |
| - | Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. | 115 | RM | 10 | ₹1,150 |
| - | M&L for Concrete angle-fillets of required radiaus shall be provided at junctions between roofs and vertical faces of walls (parapet, pillar for water tank staging and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.with cement concrete 1:2:4 (Using 12.5mm stone aggregate) mixed with liquid polymer (SBR Latex liquid polymer will be mixed as per manufactur direction and paid separately) complete all as directed by Engineer in Charge. | 1 | Cum | 10 | ₹10 |
| - | Supply only SBR Latex liquid polymer of approved make complete all as directed by Engineer in Charge. | 14 | Per Ltr | 10 | ₹140 |
| - | Taking down existing tarfelt and plaster from roof and removing from site all as directed. | 40 | Sqm | 10 | ₹400 |
| - | M&L of water proofing treatment to roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying evenly a tack coat @ 1.2 kg/Sqm using 85/25 grade of industrial hot blown bitumen on primed surface of roof by applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.
(b) Providing APP modified 5 layer polymeric membrane minimum weighing 3.6 Kg /Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note :
1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only
2. The work is required to be carried out at roof slab . The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof for site inspection . The rates quoted shall deemed to be included for these items.) | 240 | Sqm | 10 | ₹2,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
8617Tenderdoc.pdf
Tender Documents • 1.42 MB
BOQ_890725.xls
BOQ • 0.36 MB
8617Scheduleofcredit.pdf
Additional Documents • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .