| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹6.5 L+₹7,054.70 (1.11%)Accepted-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L2 | Accepted-Finance L2 | |
| 3 | L3₹7.2 L+₹77,652 (12.2%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹7.3 L+₹90,403.10 (14.2%)Accepted-Finance | L4 | Accepted-Finance L4 | |
| 5 | L5₹7.4 L+₹1.0 L (16.0%)Accepted-Finance | L5 | Accepted-Finance L5 |
| Sl No | Description | Qty | Unit | M/s RAM LAKHAN GUPTA L2 | M/S DARSHAN ENGINEERING WORKS L6 | Khan Brothers L5 | m/s allied enterprises L3 | VIDYA TRADERS L4 | MISHRA TRADING CORPORATION L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, laying,jointing & testing 16 Sqmm 4 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) ,laid in trenches, ducts, pipes or on poles etc including cable lugs, jointing, supporting clamp complete etc complete all as specified and directed by Engr-in-Charge. | 100 | RM | 180 ₹18,000 | 220 ₹22,000 | 180 ₹18,000 | 125 ₹12,500 Lowest | 205.5 ₹20,550 | 160 ₹16,000 |
| 2.00 | Ditto all as above item No 1.00 here in before but for size 10 Sqmm 2 core complete all as specified and directed. | 280 | RM | 140 ₹39,200 | 140 ₹39,200 | 105 ₹29,400 Lowest | 115 ₹32,200 | 140 ₹39,200 | 130 ₹36,400 |
| 3.00 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 49.5 | Cum | 90 ₹4,455 Lowest | 120 ₹5,940 | 200 ₹9,900 | 280 ₹13,860 | 150 ₹7,425 | 120 ₹5,940 |
| 4.00 | Returning, filling in, any type of soil and spreading in layers n. exc 25 Cm thick each layer including watering & well ramming complete all as specified & directed. | 27.46 | Cum | 50 ₹1,373 Lowest | 100 ₹2,746 | 70 ₹1,922.2 | 60 ₹1,647.6 | 150 ₹4,119 | 80 ₹2,196.8 |
| 5.00 | Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. | 14.5 | Cum | 30 ₹435 Lowest | 110 ₹1,595 | 50 ₹725 | 85 ₹1,232.5 | 100 ₹1,450 | 70 ₹1,015 |
| 6.00 | M& L for sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in trenches for protection of U/G cable complete all as specified and directed by Engr-in-Charge. | 1.5 | per 1000 | 5,000 ₹7,500 | 6,000 ₹9,000 | 4,500 ₹6,750 | 3,400 ₹5,100 Lowest | 4,700 ₹7,050 | 3,600 ₹5,400 |
| 7.00 | M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed.Note: Punned thickness of sand will be measured only. | 14.39 | Cum | 600 ₹8,634 | 500 ₹7,195 | 800 ₹11,512 | 780 ₹11,224.2 | 760 ₹10,936.4 | 450 ₹6,475.5 Lowest |
| 8.00 | S & F in replacement GI pipe light grade 50mm bore. for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallahetc complete all as specified & directed. | 12 | RM | 300 ₹3,600 | 290 ₹3,480 | 250 ₹3,000 Lowest | 290 ₹3,480 | 450 ₹5,400 | 350 ₹4,200 |
| 9.00 | Ditto all as per ser item No.8 here-in-before but 40mm bore. | 18 | RM | 250 ₹4,500 | 300 ₹5,400 | 200 ₹3,600 Lowest | 280 ₹5,040 | 400 ₹7,200 | 250 ₹4,500 |
| 10.00 | Cutting of floor/wall/footpath for removal of LT U/G cable of any size/description and making good with PCC 1:3 :6 type C-2 the same as per existing specification after relaying the same or new cable and all as specified & directed. | 18 | RM | 200 ₹3,600 | 300 ₹5,400 | 55 ₹990 | 60 ₹1,080 | 150 ₹2,700 | 20 ₹360 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Jun 2026, 6:00 pmClosed
AGE (I) Ayodhya Cantt
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
Repair replacement and maintenance of Streetlights and securitylights accessories and UG cables Timer Panel incl connected item of works of Kandhar line DP Line Shivaji Line Saryu Niwas and nearby Md Accn area at Ayodhya Cantt under AGE (I) Ayodhya
2026_MES_768555_1
8400/177/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Ayodhya
₹20,000
Yes
6 Aug 2026
29 May 2026
29 Jun 2026
29 May 2026
27 Jun 2026
13 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, laying,jointing & testing 16 Sqmm 4 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) ,laid in trenches, ducts, pipes or on poles etc including cable lugs, jointing, supporting clamp complete etc complete all as specified and directed by Engr-in-Charge. | 100 | RM | - | - |
| 2 | Ditto all as above item No 1.00 here in before but for size 10 Sqmm 2 core complete all as specified and directed. | 280 | RM | - | - |
| 3 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 49.5 | Cum | - | - |
| 4 | Returning, filling in, any type of soil and spreading in layers n. exc 25 Cm thick each layer including watering & well ramming complete all as specified & directed. | 27.46 | Cum | - | - |
| 5 | Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. | 14.5 | Cum | - | - |
| 6 | M& L for sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in trenches for protection of U/G cable complete all as specified and directed by Engr-in-Charge. | 1.5 | per 1000 | - | - |
| 7 | M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed.Note: Punned thickness of sand will be measured only. | 14.39 | Cum | - | - |
| 8 | S & F in replacement GI pipe light grade 50mm bore. for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallahetc complete all as specified & directed. | 12 | RM | - | - |
| 9 | Ditto all as per ser item No.8 here-in-before but 40mm bore. | 18 | RM | - | - |
| 10 | Cutting of floor/wall/footpath for removal of LT U/G cable of any size/description and making good with PCC 1:3 :6 type C-2 the same as per existing specification after relaying the same or new cable and all as specified & directed. | 18 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
TENDERDOCS177.pdf
Tender Documents • 0.93 MB
BOQ_860683.xls
BOQ • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .