Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹32.8 L+₹15,237.50 (0.47%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹34.5 L+₹1.9 L (5.70%)Rejected-Finance | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder |
Tender Value
₹39.2 L
EMD Value
₹78,400
Closing Date
2 Jul 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-65 OF 2019-20 SPECIAL REPAIRS TO BUILDING NO. P-804(A) TO P-804(F) AND P-815(A) TO P-815(F) (OR MARRIED ACCOMMODATION) AT MILITARY STATION FARIDKOT
2020_MES_317016_1
CA NO. CWE SGNR - 65 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
FARIDKOT
Class D
Category a(i)
10 documents required · 10 mandatory
₹500
GE FARIDKOT
₹78,400
Yes
28 Jul 2020
26 May 2020
4 Jul 2020
26 May 2020
2 Jul 2020
18 Jun 2020
Amount
Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames exc 1.5 Sqm but n exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down & refixing of Shutter in the same opening of any description exc 1 sqm but not exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down Shutter of any description exc 1 sqm but not exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F Pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engineer-in-Charge.
S&F Pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engineer-in-Charge.
M&L mild steel framed work of Fe-290 (Gde E-165) as in grills/guard bars shouldered with steel windows/ventilators frames. Cooler stand, ladder etc including redoxide primer coat complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick 2nd class hard wood plain framed pannel shutters (any number of pannels) with pannels of timber flat on both sides (feather edges) or of vaneered partical board medium density, wood partical board with commercial face veneers fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F pressed steel rectangular frames for built in cupboard doors, made out of mild steel sheet 1.25mm thick with girth of frame 185mm including MS rawls plugs and incl fixing 100mm long butt hinges medium weight cold rolled mild steel etc including two coats of synthetic enamel paint over a shop coat of zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
S&F pressed steel door shutters including stiffeners made out of mild steel sheet 1.25mm thick cut to size, holes punched and welded seams including bending or turning up all around, mitered angle, one No of locking arrangement two nos Handle etc and applying two coats of synthetic enamel paint over a shop coat of zinc chrome primer all as per Godrej pattern complete all as specified and directed by Engineer-in-Charge. Note : (i) Measurement of door shutter shall be taken as exact size of cupboard opening (excluding frame and folded/ turned up portion) (ii) Stiffeners of 150mm girth and height equal to height of shutter made to shape as directed by Engr-in-charge. cost of these stiffeners shall be deemed to be included in the unit rate quoted for door shutters and no extra measurement/payment shall be made for the same.
M&L in repair block boards 18/19mm thick, grade 2 quality, interior grade, decorative type with decorative face veneer on one face fixed with screws to frame-work complete all as specified and directed by Engineer-in-Charge.
S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass of 3mm,ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
S&F in repair Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
S&F 3mm th Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F Solid wood moulded grain printed PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, egdes will be painted to match printed sheets, in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long Aluminium handles cast type anodised complete all as specified and directed by Engineer-in-Charge.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 125 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasps & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinges, medium weight, cold rolled, mild steel and fixed complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted steel surface of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new or previously untreated surface of wood or wooden based surface any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted surface of wood or wooden based surfce any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F in repair MS powder coated decorative drapery rod (colour as approved) of 20mm dia approved pattern & design including decorative knobs (wall side and free side) & powder coated mild steel flat iron brackets fixed with steel screws & PVC rawl plugs/grips complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C0 using (12.5mm graded stone aggregate) as in back filling of pressed steel frames, bed blocks, coping, fixing of hold fasts etc including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge.
S&F Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer in CM 1:6 for laying finishes, complete all as specified and directed by Engineer-in-Charge.
All as per item No 37 here-in-before but for in vertical surfaces such as skirting, dados & risers to steps etc over 10 mm thick backing plaster in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
S&F glazed ceramic tiles (coloured tiles) of size 450 x 300 x7 mm thick over 15 mm thick backing plaster in CM 1:4 as on vertical surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match etc on other than fair face of brick work complete all as specified and directed by Engineer-in-Charge.
M & L for 20-25mm thick machine cut kota stone slab in flooring over 20 mm thick screed bed in CM 1: 4 , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick backing plaster in CM 1:4 , jointed with gray cement sullary mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L 20mm thick granite work (of any type) (table rubbed and polished) over 15 mm thick screed bed in CM 1: 4 as on cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including nosing edges complete all as specified and directed by Engineer-in-Charge.
Demolition of concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 50mm thick type C2, 1:3:6 using 20mm graded stone aggregate as in plinth protection/path, finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for taking down cement plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement plaster 1:6 on surface other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement plaster 1:4 on fair faces of brickwork or stone masonry surfaces or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp complete all as specified and directed by Engineer-in-Charge. : 1. SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non-moving cracks having width upto 5 mm must be filled with Polymer based crack filler. 2 APPLICATION: Apply the first coat of Roff Hydamp with a paintbrush directly on the prepared surfaces. Allow to dry for a minimum 2-3 hrs. Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Roff Hydamp on the entire surface. Make : Dr. Fixit or equivalent make as approved by GE Note : Treatment shall be carried out through authorized dealer / applicator only.
M&L preparation of newly plastered or unplastered surfaces of wall by mechanical method i.e. electric grinder and applying two coat of distemper oil emulsion white/tinted with a wall care putty finished surface over one coat of primer by mechanical roller/ hand roller complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by mechanical method i.e. Electric grinder and applying two coats of distemper oil emultion white/tinted with a wall care putty finished surface over one coat of primer using mechanical roller/hand roller complete all as specified and directed by Engineer-in-Charge
M&L preparation of newly plastered or unplastered ceiling surfaces and applying two coat of distemper oil emulsion white/tinted on 3 mm thick wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer-in-Charge
M&L preparation of newly plastered or unplastered ceiling surfaces and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge
M&L complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of distemper oil emultion white/tinted with 3 mm thick wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer-in-Charge
M&L preparation of old surfaces of ceiling and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge
M&L preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge
M&L complete removal of existing treatment such as white wash, colour wash, synthetic enamel paint etc of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge Note :- Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge
M&L for RCC 1:2:4 Type B-1 (20mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies and in shelves complete all as specified and directed by Engineer-in-Charge
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge
S&F MS TMT Bars of 6mm to 8mm dia,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer-in-Charge
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge
M&L old size brickwork with fly ash bricks straight or curved on plan exc 6m mean radius wall built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 63 here-in-before but for except bricks complete all as specified and directed by Engineer-in-Charge
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge Note : Payment for providing grooves shall be made separately
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-Charge
Taking up or down 15mm dia GI Tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge
Taking up or down 20mm dia GI Tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge
S&F 15mm bore GI tubing medium grade with all fittings fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 69 here-in-before but for except tubes complete all as specified and directed by Engineer-in-Charge
S&F 20mm bore GI tubing med grade with all fittings fixed to walls or laid in floors complete all as specified.
All as per Srl item No. 71 here-in-before but for except tubes complete all as specified and directed by Engineer-in-Charge
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S&F 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair 15 mm fancy type chromium plated Angle valve/stop valve, screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm fancy type chromium plated pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, CI 'P' or 'S' traps 100mm & PVC flush pipes 32mm dia including connecting to trap and to flushing pipe, anti-syphonage pipe etc including all joints and making good to floor complete all as specified and directed by Engineer-in-Charge
S&F in repair 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level including flush pipe, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge
S&F in repair vitreous china wash basins, size 550x400mm white flat back including cutting for and pinning in ends of brackets or erecting stand including 32mm dia CP waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engineer-in-Charge
S&F PVC Connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge
S&F in repair stainless steel plate rack 1.25mm thick of size 900x775x250mm made out of 1mm thick stainless steel of first quality complete all as specified and directed by Engineer-in-Charge
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge
S&F in repair swivel shower of PTMT any colour for fixing 15mm pipe (Minimum weight 40gms) with shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and directed by Engineer-in-Charge
S&F in repair towel rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all as specified and directed by Engineer-in-Charge
S&F in repair cast iron or mild steel peg set 175mm to 250mm with hooks fixed to wall complete all as specified and directed by Engineer-in-Charge
Dismantling CI/PVC pipe alongwith fittings of 75/100mm dia,below or above GL, laid in floors or fixed to walls jointed in cement mortar and taking out complete all as specified and directed by Engineer-in-Charge
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) bend any radius 110 mm bore complete all as specified and directed by Engineer-in-Charge
S&F 100mm dia sand cast iron soil, waste and vent pipe, in any length with or without ears incl necessary fittings with cement joints laid in trenches, in floors or fixed to walls complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 92 here-in-before but for 75mm bore pipe complete all as specified and directed by Engineer-in-Charge
S&F 100 dia CI bends, diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge
S&F 75 dia CI bends, diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge
M&L in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc complete all as specified and directed by Engineer-in-Charge
S&F branch pieces, 100mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge
S&F branch pieces, 75mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge
S&F 75mm cast iron vent cowls complete all as specified and directed by Engineer-in-Charge
S&F in repair Rotational moulded polythylene 500 capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including PTMT float valve 20 mm bore, high pressure with polythene ball & float & dismantling of old water tank complete all as specified and directed by Engineer-in-Charge
M & L for water proofing treatment to RCC sunken slab as specified below complete all as specified and directed by Engineer-in-Charge.:- (a) Rendering 15 mm thick in cement mortar 1:3 using water proofing compound on raised vertical surfaces after demolition of PCC (b) Cleaning the surface with wire brush / coir brush, removing loose material like dust particles, dirt etc. (c) Creating fillet covering of 50 x 50 mm with polymer modified mortar on the junction of slab and wall (d) Apply first coat of two component modified polymer coating on the horizontal and vertical surface upto 300mm above wall surface. (e) Provision of Polyester reinforced coated net of 45 g/m2, 2.5 mm x 2.5 mm immediately on above coating. (f) Apply second coating of two component modified polymer coating after 72 hrs upto 300mm above wall surface. (g) Laying concrete 1:4:8 over the coating as per requirement. (h) Joining the sanitary pipes with the waterproofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and sanitary pipe with non shrink cementatious grout. (k) Water Proofing treatment to be carried out by authorized applicator of water proofing manufacturer. Make : Dr/ Fixit / Fosroc / BASF / STP Note : (i) The treatment shall be carried out as per manufacturer instructions and as directed by Engineer-in-Charge. (ii) The plan area of floor shall be considered for payment. (iii) WPC shall be measured and paid separately.
M&L for rendering 10 mm thick in cement plaster 1:4 with WPC on roof, fair faces of brick work or concrete surfaces complete all as specified and directed by Engineer-in-Charge Note : WPC will be measured and paid separately
M&L for roof treatment as specified below and complete all as specified and directed by Engineer-in-Charge. :- (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brushing or high speed water jet. Surface should be feree from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal / Epoxy. Primer / ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 Kg / Sqm (0.20 Kg BTD + 0.20 Kg Water) (d) Laying polyster reinforced fiber net / 50 GSM Geotextile mesh, upto 300mm on walls. (e) Applying three coats of HydroShield PUD microfiber reinforced UV resistant polyurethane (solid content 68%) / Damp Proof Ultra UV Stable fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers (Solid content 55%) / SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%) / Single Component Elastomeric Liquid Membrane Shaliurethane BTD White / Coloured (Elongation 400% + 50, Solid Contents > 80% and Specific Gravity @ 30 OC 1.5 + 0.03) @ total 2.00 Kg Per Sqm in two coats of maintaining thickness of 1.5mm with paint brush / roller upto 300mm on walls. (f) The complete treatment to be carried out by authorized applicator only. Make : Dr. Fixit / Asian / STP
M&L 40mm thick PCC 1:2:4 type B0 (12.5mm graded stone aggregate) with WPC in roof complete all as specified and directed by Engineer-in-Charge Note : WPC will be measured and paid separately. (WPC will conforms to IS: 2645-2003)
Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L 150mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
M&L 150mm bore Concrete bed (PCC 1:3:6 type C2) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
S&F Factory made SFRC (Steel fiber Reinforcement Concrete ) Manhole cover medium duty 900mmx450mm x70mm thickness including 2mm thick flat iron frame all round complete all as specified and directed by Engineer-in-Charge.
M&L for hard core of broken bricks gauge n. exc 63mm depositing, spred and levelled in layers n.exc 15cm thick watering and ramming to true surface with broken stone boulders complete all as specified and directed by Engineer-in-Charge.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Machine pressed precast conctete interlocking paver block, with grey cement and pigment and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C1 (20mm graded crushed stone aggregate) in kerbs, rounded or chamfered on edges, slightly rounded or chamfered angles and throating, (in sides of path/paving) complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as Switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface complete all as specified and directed by Engineer-in-Charge
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers / MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes painted with one coat of red oxide primer all around for mounting of switches, sockets, fan regulators etc. covered with 2.8mm thick plastic laminate (Hylem / Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for one light point / call bell point / fan point to be controlled by one number one way point switch complete all as specified and directed by Engineer-in-Charge.
Switch socket combination 3/5 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 1.5 Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer-in-Charge
All as per item No. 119 here-in-before but on same board complete all as specified and directed by Engineer-in-Charge
One bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
One light point controlled by two 2-ways switches, with cables 1.5 Sqmm size complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 2.5 Sqmm single core multi standed copper conductor PVC insulated and unsheated, flame retardant Low Smoke (FRLS) cable of 3/6 pin 15 Amps socket outlet controlled by one switch on independent board with and including 2.5 Sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed by Engineer-in-Charge.
S&F bell AC 230 Volts single pole Ding Dong type complete all as specified and directed by Engineer-in-Charge.
S&F switch bell push button type 6 Amp single pole complete all as specified and directed by Engineer-in-Charge. Cat Part No F 902 for switch and F-919 for Switch frame of Make : SSK or equivalent in Legrand / Hager.
M&L for switch piano flush type single pole two way, 5/6 Amp fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan regulator electronic dimmer, 450 W, 250 V flush type on existing phenolic laminated sheet including connections complete all as specified and directed by Engineer-in-Charge. Cat Part No. F 911 for regulator and F-920 for socket frame of make SSK or equivalent in Legrand / Hager.
S&F switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 900 for switch and F-919 for Switch frame of Make : SSK or equivalent in Legrand / Hager.
S&F socket 5 pin shuttered 6A 250 V AC including 6 A Socket frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 904 for socket and F- 920 for Socket Frame of Make SSK or equivalent in Legrand / Hager.
S&F Switch single pole mini with porcelain Base 16 A 250 V AC with ISI mark including switch frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 954 for Switch and F-919 for Switch Frame of Make SSK or equivalent in Legrand / Hager.
S&F socket 5 pin shuttered 6A/16Amp 250 V AC i2 in 1 ncluding 16 A Socket frame complete all as specified and directed by Engineer-in-Charge. Cat Part No F 951 for socket and F- 920 for Socket Frame of Make SSK or equivalent in Legrand / Hager.
S&F Ceiling rose having three terminals polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED mirror light fitting 1 x 5 watt including LED tube complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting 1 x 20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
S&F decorativeDecorative wall light fixture made up half cut frosted glass suitable for and including 1 x 9 W LED Lamp with B-22 base complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lamp holder with1 x 10 watt LED lamp B-22 base complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
S&F 1 x 10 Watt LED Bulk head luminaries with lamp, holders, 850 lm with an efficacy of 85 lm/w etc complete with accessories pre wired and including connecting with flexible cord 3 core 0.5 sqmm complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of ceiling fan 1200 mm sweep complete AC single phase 230 Volt 50 HZ connecting with new flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including spry painting, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.complete matching with existing colour and all hanging arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Exhaust fan light duty AC single Phase 230 V / 240V 50 Hz of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of Storage water heater 25 ltrs cap vertical mounting AC 230 Volts including connecting cord and plug, safety valve, nuts and bolts, complete including grouting of nuts and bolts complete all as specified and directed by Engineer-in-Charge.
M&L for distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S & F as in replacement of MCB distribution board double Door of sheet metal TPN 4 way with 415 Volts complete with and including MCCB 63 Amps,16KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 40 Amps S & F as in replacement of MCB distribution board double Door of sheet metal TPN 6 way with 415 Volts complete with and including MCCB 63 Amps,16KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Isolator suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 63 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, Sub main wiring with 2 single core 6 Sqmm PVC insulated flame retardant low smoke cable with multistranded copper conductor cable ISI marked in and including suitable size of PVC conduit medium quality conforming to 3537 Part-I & conduit accessories with and including independent PVC insulated one single core 6 Sqmm flame retardant low smoke un-sheathed and multistranded copper earth wire complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three lengths of single core 6 Sqmm cable and suitable size of PVC conduit will be measured as one length)
Supply & laying in repairs, LT under ground cable XLPE insulated armoured and PVC sheathed 4 core 16Sqmm cross sectional area heavy duty electric with aluminium conductor 1100Volts grade in trenches / passing through pipes including including cable connecting lugs, glands, jointing fixing materials after taking out exisisting unserviceable cables complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry and clean fine river sand for underground cable 8cm before laying the cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge
Supplying and laying well burnt clay bricks old size class 'B' laid dry and flat for protection over the cable with equal to the length of cable, complete all as specified and directed by Engineer-in-Charge.
S & F PVC sleeves for connection of conductor to MCB DB any type any size complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth not less than 1.5 Mtr below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles upto equipment and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 20mm dia upto earthing test point / equipment fixed with 2 Nos. of mold steel clamps made out of 25mm x 3mm flat iron and preforated water pipe 20mm dia galvanized iron pipe heavy grade 2.25 Mtr long and top with socket and plug and bottom connected to earth plate by silt and two bolts / nuts / washers complete with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and cast iron cover with frame all as shown on electrical plate No. 3 of MES Schedule Part - I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Note : (i) Outer edge of earth pit will be 1 Mtr away from the outer edge of PCC Chamber. (ii) Galvanized iron earth wire 4mm dia upto earthing test point / equipment is encluded in this item. (iii) Water pipe shall be provided in slainting position. (iv) 20mm dia galvanized iron pipe for watering shall be provided with a socket and plug and shall be 10cm above the ground level.
S&F in repairs, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing LED street/Security light fitting of 25 watt including LED lamps complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall with 1.2 mtr long GI pipe 32 mm dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report complete all as specified and directed by Engineer-in-Charge. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 73,071.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 35 & 36(R) (Schedule of Credit) of Tender document
M/s Balvinder Singh Engineer and Contractors
NEW AMRITSAR CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .