Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹19.8 Laccepted-aoc | accepted-aoc |
Tender Value
₹22.0 L
EMD Value
₹25,000
Closing Date
16 Apr 2025, 9:30 pmClosed
Public Works Department
Rajesh T
Maintenance to Electrical Installation, Street lights and Lawn Lights, Split Air condition Units and Labour Charges for Operation & Maintenance charges at Honorable Ministers & Judges Residences at K.K.South, Ministers Quaeters at Crescent Road, Ministers Quaeters at Race View Compound at Bangalore.
PWD/2024-25/EL/WORK_INDENT15474
PWD/2024-25/EL/WORK_INDENT15474
Reserved
Electrical
Two Tender Document System(Two Cover)
PWD Electrical Division Office Bengaluru
11 documents required · 11 mandatory
3.2To qualify for award of this contract, each Tenderer in its name should have in the last five year period i.e. from 2020-21 to 2024-25.(b) Satisfactorily completed at least Any Engineering Works of value not less than Rs.5.51 Lakhs in a single work
The tenderer as a Prime Contractor having valid Class-2 & above Electrical License issued by Electrical Inspectorate Govt. of Karnataka and should have suitable technical, financial & managerial capabilities.
3.2To qualify for award of this contract, each The Tenderer in his name should have in the last five years i.e. from 2020-21 to 2024-25. (c) Executed in any one year, the following minimum quantities of work :- 1) Providing Electrician/Helper for Day to Day Routine Operations - 648 Man Days
3.3b) The tenders must be accompanied liquid assets and /or availability of credit facilities of no less than Rs.6.62 Lakhs. (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually 30% of the Amount of the Contract)
3.6Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under/ Assessed available tender capacity - (AxNx5 - B ) Where, A-Maximum value of construction works executed in any one year during the last five years (updated 2024-25 price level) taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. (12 Months) B - Value, at 2024-25 price level, of existing commitments and on-going works to be completed during the next. (12 Months) (period of completion of the works for which Tenders are invited) Note: The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent
The Tenderer must submit ongoing and existing commitments details separately.
The Tenderer must belongs to the Scheduled Caste & also to the furnished Scheduled Caste Certificate.
The Tenderer belonging in to the Scheduled Caste shall be Domicile of The State of Karnataka for more than 10 years. Must furnish the relevant Certificate.
The Tenderer Must have submitted the Certification of registration in the Labour department with the latest renewal.
The bidder should have a valid license of PF and ESI registration.
3.2To qualify for award of this contract, each Tenderer in its name should have in the last five year period i.e. from 2020-21 to 2024-25. a) The tenders must have achieved in at least One financial years a minimum financial turnover of Rs.22.04 Lakhs during last five years. with UDIN Number certified by Chartered Accountant, Note: The returns submitted to the I.T. along with the Profit and Loss account statement, Balance sheet should be uploaded for the financial turnover criteria
₹560
₹25,000
16 Apr 2025
1 Apr 2025
17 Apr 2025
7 Apr 2025
Maintenance to Electrical Installation, Street lights and Lawn Lights, Solar System, Split Air condition Units and Labour Charges for Operation & Maintenance charges at Honorable Ministers & Judges Residences at K.K.South, Ministers Quarters at Crescent Road, Ministers Quarters at Race View Compound at Bangalore.
12.19 Supplying and fixing of Electronic Ballast suitable for T5 Lamp with housing made of Pre-coated steel/PC Operating voltage range from 180V to 265V 50Hz AC power Supply flicker free warm start ...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.1 6A One Way Switch ---- in...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.2 6A Two Way Switch ---- in...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.3 6A Three Way socket ---- ...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.4 Stepped Fan Regulator Two...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.7 16A One Way Switch ---- i...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.8 6A Bell Push ---- includi...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.9 32A DP Switch ---- includ...
3.6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24-PWD-Electrical-Uni SR-Item code- 3.6.10 6/16A Universal Socket -...
12.13 Supplying and fixing/replacement of heating element for Geyser/Boiler. 2023-24 - PWD-Electrical - Uni SR- Item code - 12.13.1 2kW Capacity ---- including cost and conveyance of all materials, la...
12.13 Supplying and fixing/replacement of heating element for Geyser/Boiler. 2023-24 - PWD-Electrical - Uni SR- Item code - 12.13.2 3kW Capacity ---- including cost and conveyance of all materials, la...
12.7 Releasing an unserviceable thermostat and providing in its place a new 20 A capacity 25 inch to 85 inch range thermostat. 2023-24 - PWD-Electrical - Uni SR- Item code - 12.7 ---- including cost a...
12.14 Supplying and fixing/replacement of pressure relief valve suitable for Geyser. 2023-24 - PWD-Electrical - Uni SR- Item code - 12.14 ---- including cost and conveyance of all materials, labour an...
5.18 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON/OFF energy cross-3 with Short circuit breaking...
5.18 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON/OFF energy cross-3 with Short circuit breaking...
5.18 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON/OFF energy cross-3 with Short circuit breaking...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
9.3 Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and...
9.5 Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 2023-24-PWD-Electrical-Uni SR-Item code - 9.5.7 1...
9.4 Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 2023-24-PWD-Electrical-Uni SR-Item code - 9...
5.47 Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. 2023-24-PWD-Electrical-Uni SR-Item co...
5.13 Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 20...
5.12 Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 2023-24-PWD-Electrical-Uni SR-Item code-5.12 5.12...
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condens...
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condens...
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A...
Supplying and installation of insulated refrigerant copper tubing of 5/8 inches and 3/8 inches with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing...
6.14 Supplying installation testing and commissioning of heavy duty compressor suitable for window/split type A/C. 2023-24-PWD-Electrical-Uni SR-Item code- 6.14.2 1.5Ton ---- including cost and convey...
6.14 Supplying installation testing and commissioning of heavy duty compressor suitable for window/split type A/C. 2023-24-PWD-Electrical-Uni SR-Item code- 6.14.2 Ton ---- including cost and conveyanc...
6.15 Supply and fixing of condensing coil for Split Air Conditioners. 2023-24-PWD-Electrical-Uni SR-Item code- 6.15.3 2 Ton capacity ---- including cost and conveyance of all materials, labour and oth...
6.16 Supplying and fixing capacitor's (of approved make) for window /split air conditioners. 2023-24-PWD-Electrical-Uni SR-Item code- 6.16.1 25 to 45mfd running capacitor. ---- including cost and conv...
6.16 Supplying and fixing capacitor's (of approved make) for window /split air conditioners. 2023-24-PWD-Electrical-Uni SR-Item code- 6.16.2 80 to 200mfd starting capacitor. ---- including cost and co...
6.17 Supplying & fixing relay for over load protection for window and split air conditioners. 2023-24-PWD-Electrical-Uni SR-Item code- 6.17 ---- including cost and conveyance of all materials, labour ...
6.18 Supplying and fixing the fan motor for blowers and condenser of 1/5 HP, single shaft/double shaft suitable for split /window air conditioners. 2023-24-PWD-Electrical-Uni SR-Item code- 6.18 ---- i...
6.19 Supplying & filling refrigerant (F-22/F/12) for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. 2023-24-PWD-Electrical-Uni SR-Item code- 6.19...
6.20 Supplying & fixing of thermostat for window type air conditioner. Multi range 30 to 60 degree Centigrade (without probe), adjustable universal type 2023-24-PWD-Electrical-Uni SR-Item code- 6.20 -...
6.21 Supplying and fixing electro mechanical / Pneumatic time switches. 2023-24-PWD-Electrical-Uni SR-Item code- 6.21 ---- including cost and conveyance of all materials, labour and other incidental c...
Servicing of 2 KVA - 10KVA UPS system with all necessary components including servicing of systems battery maintenance etc., complete throughout the year (AQR) SE ltr no:706 dt:11.05.2020 SL No(6) ---...
Comprehensive maintenance for 1x5.5 TR centralized Air conditioning system, chillers package comprising of 3x100 TR=300 TR which includes filling of gas, leakage testing, pressure test, Servicing of c...
Service Charges for 1.TR to 3 TR split type AC unit and general checkup etc., (AQR) SE ltr no:705 dt:11.05.2020 SL No(3) ---- including cost and conveyance of all materials, labour and other incident...
Skilled Electrican. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specificatio...
Un Skilled Helper ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification ...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
government notification bc loc letter to be issued by the bank (1)(1).pdf
Others - Bankers Certificate format • 1.73 MB
KPPP kw-2 bid_15474 SC.docx
Tender Document • 0.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .