Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹46.9 L+₹3.0 L (6.87%)Rejected-Finance 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹47.3 L+₹3.4 L (7.82%)Rejected-Finance FLAT NO 02 RUTUPARNA APARTMENT PLOT NO 36 S NO 324 2A NEAR G D SAWANT COLLEGE PATHARDI NASIK 422 010 | NASHIK | MAHARASHTRA | 422010 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹48.6 L+₹4.7 L (10.8%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L4 | Rejected-Finance Not lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP ComplexNear AOP Gate PO Gandhinagar Nasik 422006
AS per Tender Document
2023_MES_607406_1
GE/NRC/8992/E8
Open Tender
Civil Works
Item Rate
334 days
Garrison Engineer Nasik Road
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Nasik Road
₹1 L
Yes
12 Aug 2023
1 Jul 2023
31 Jul 2023
1 Jul 2023
29 Jul 2023
15 Jul 2023
Amount
M&L for preparation of old decorated plastered or unplastered surfaces including brooming down moulds & efflorescent salt & trading oil & greasy spots and applying one two of white wash on walls.
All as per item No. 1.00 Above but on ceiling.
M&L for 1.5 mm thk wall care putty on walls
M&L for 1.5 mm thk wall care putty on ceiling
M&L for Complete removal of existing treatment and applying two coats of interior emulsion paint white or tinted on walls over a coat of primer incl preparation of surfaces.Preparation of surfaces shall be done in accordance to the clause No 15.14.2.1 of SSR Part-I(2009)
All as per Item No. 5.00 Above but on ceilling
M&L for preparation of old painted wooden surfaces of any description,not other wise described,over 10 cm width or girth and applying one coat of synthetic enamel paint.
M&L for preparation of old painted steel surfaces of any description,over 10 cm in width or girth,not other wise described and applying one coat of synthetic enamel paint of tint as directed by engr-in-charge.
M&L for preparation of old surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots; removing nails, making good holes,minor plaster work(incl curing) not exceeding 5 sqm each bldg, exceeding 5 sqm shall be paid separately, cracks of any size and depth filling with POP or by plastering as directed by Engr-in-charge. and applying one coat of exeterior emulsion paint on walls over a coat of primer on wall/ceiling at any height.
M&L for complete removal of existing treatment to wall/ of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots; removing nails, making good holes,minor plaster work not exceeding 5 sqm each bldg in total exceeding 5 sqm shall be paid separately cracks of any depth by filling with POP or by plastering as directed by Engr-in-charge. and applying two coat of exeterior emulsion paint on walls and ceilling .(apex/weathercoat) on walls and ceiling plastered or unplastered surfaces.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc.
M&L for brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM 1:6.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for Rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces finished fair and even.
M&L for Repairing of broken edges of RCC chajjas, roof projections, fins, facia and similar works by dismantling of loose and damaged/ disintegrated portion of edges (cross sectional area not exceeding 150 sqcm) with cement mortar 1:4 or cement concrete 1:1½:3 type A0 and chicken wire mesh with nails (to hold fresh mortar/concrete) including necessary formwork etc. and scaffolding for work upto four storied buildings and finishing the surface by paint to the entire satisfaction of engr-in-charge and match the surface with existing work.
Plastering on walls in cement mortar 1:4 in patches not exc. 3 Sqm on the buildings upto four storied, including taking down old plastering on walls, any description including finishing the surface to match existing surfaces including necessary scaffolding and finishing the surface by white wash or cement base paint to match the surface with existing work.
Taking down MS window/ventilators frames with shutters of any size and any description,making good soffits,jambs,cills etc to receive new windwo/ventilators frame complete all as specified and as directed.
S&F aluminium (minimum 50 micron powder coated) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F aluminium (minimum 50 micron powder coated) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified.
S&F aluminium (minimum 50 micron powder coated) window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays/tower bolt 150mm long (1 No.) hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.), rollers, grip etc. complete all as specified.
Dismantling wrought iron or mild any description such as steel gate, steel frame works, purlins, rafter, railings, balusters and window guard bars and directed by Engr-in-Charge.
S&F Framed work as in grill, doors or gates of angle or other section with gusset plates, braces, etc, complete, drilled for fixing of steel sheeting or other covering, Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe Grade 290(Gde E-165) complete all as specified and directed by Engr-in-Charge.
S&F 3.0 mm thick sheet glass, ordinary quality and glazing with silicon gel in square n exc 0.5sqm in each pane.
S&F 5.50 mm thick sheet glass, ordinary quality and glazing with silicon gel in square exc 0.5s qm in each pane.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
M&L for Preparing new untreated steel or iron surfaces over 10cm width or girth and and two coats of synthetic enamel paint over and including a coat of red oxide.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) n exc 1.5 sqm each and making good the jambs, soffits of lintels etc. after fixing of new chowkat or frame to match the existing surface.
Solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per specification and drawing.
M&L for Factory made solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded prelam PVC Sheet on the front face and 2 mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each and making good the jambs, soffits of lintels etc. after fixing of new chowkat or frame to match the existing surface.
M&L for 2nd class hardwood for Plain,solid,straight chowkhats and frames,framed rebated on the solid,rounded or chamfered, put together with glue pinned at,complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and n. exc 2 Sqm each.
Taking down shutters of any description exc 2 Sqm each.
M&L for 35mm thick second class hard, wood factory, made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
S&F factory made plain framed paneled shutters 35mm thick of 2nd class hard wood (any number of panels ) with panels of timber flat on both sides feather edges or panel of 9mm BWP commercial ply over 12mm thick veneered particle board with commercial face veneers fixed to chowkat. The size of rail and stile as per IS: 1003 (Part-1), kiln seasoned and chemically pressure treated complete all as specified and directed.
Preparing new wood or wood based surfaces over 10cm width or girth and two coats of synthetic enamel paint over and including a coat of pink primer.
S&F 100mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21.
S&F 200mm size aluminium anodised, barrel tower bolts of extruded section and fixed.
S&F 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
S&F extruded aluminium alloy handles,125 mm size, fabricated type, anodised
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debris out of MOD land and rubbish off the premises
M&L for Non - skid coloured ceramic 7 to 8 mm thick (square/rectangular) tiles exceeding 0.18 sqm but not exceeding0.38 sqm each, in floors ,skirting etc. laid over and including 15mm thick cement mortar screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match.
M&L for Colour Glazed ceramic joint free tiles in vertical surface 350 x 250 x 7mm / 450 X 350 X 7mm thick, laid over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match.
M&L for special treatment to sunken portion with 10mm thick plaster in CM 1:4 by using Ditachment DM 1% by weight of cement and surface made smooth after curing period two coat of Ditachment DS shall be applied @2.50 Kg/Sm. The paste like consistancy like is made by using 2.5 Kg of Ditachment DS powder in one litre of admixture (The admixture is made by dissolving 1 part by volume of Nafufill SBR & 4 part by volume of water). After 7 days curing, testing shall be done by flooring for 72 hours. Finally protective plaster coat of 10mm thick in CM 1:4 shall done by using Putz Ditachment 1% by weight of cement over layer of Detachment DS. All joints of CI Pipe, Nahani trap, WC connection etc. shall be filled by mixture of cement, fine sand and 10% Nafufill SBR by weight of cement 32mm dia 450mm long GI Spout light grade shall be provided in all sunken slabs to drain off water
S&F in repair Vitreous China water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests and P/S trap (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding.
S&F in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including flush pipe and brackets complete all as specified and directed. Specification of flushing cistern shall be as per IS 7231-1994.
S&F in repairs Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. over and including flush pipe complete in all respect all as specified.
S&F in repairs Vitreous China wash basin white, flat back, size 550 X 400mm, including cutting for and pinning in ends of brackets or erecting stand, with and including 32mm waste fitting brass, chromium plated with long screwed shank and fly-nut, flange end bedded in red lead cement, brass chromium plated bottle trap with inlet and outlet screwed for pipe or connections 32mm bore, including necessary packing, union and cap and fixed in repairs. Note:wash basin shall conform to IS 2556(part-4)-2004.
M&L for Vitreous China urinals, half stall type (back or corner wall type), white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with and including 5 litres PVC automatic flushing cistern, including brackets, flush pipe, CP urinal spreader, grating union, , union and cap and discharge pipe; fixed in repairs.
M&L for PVC (SWR) floor trap(75 mm dia), plain with grating including jointing with solvent cement to mitigate the site requirement to the entire satisfaction of engr-in-charge.
Taking up or down steel tubing and connections 15mm bore including bib taps, stop cock etc.
Refixing old steel tubing and connections 15mm bore in new or old position (Walls, ceiling, floors, etc.)
S&F 15mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.
Taking up or down steel tubing and connections 20mm bore.
Refixing old steel tubing and connections 20mm bore in new or old position (Walls, ceiling, floors, etc.)
S&F 20mm bore galvanised steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F 15mm bore bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair.Specification of bib tap as per SSR Part-I.
S&F in repair hand shower (Health faucet) 1 Mtr PVC tube with wall hook (CP) complete all as specified and directed.
S&F Brass CP wash basin mixer for mixing hot & cold water scrwed down for iron pipe and 15 mm bore fixed in repair.(make : Jaquar and equivalent)
S&F Brass CP mixer for mixing hot and cold water, screwed down for iron pipe 15mm bore and fixed in repairs.(make : Jaquar and equivalent)
S&F in repair 15 mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.The specification of fancy pillar taps shall be as per SSR Part-I.
S&F in repairs 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated (angle type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.The specification of stop valves shall be as per SSR Part-I.
S&F in repairs 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.The specification of stop valves shall be as per SSR Part-I.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm
S&F 32mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm including fittings.
S&F Brass chromium plated shower rose 125mm size with swivel joint, including fixing to steel pipe or union 15mm bore.
S&F in repairs Sink made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm. Note:SS sink shall be manufactured from Salem Stainless steel grade A1 S1 305
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
M&L for Granite (of any type) work 20mm thick machine cut, (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like laid over and including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations. (Stone slabs so provided shall be not less than 900mm in length)
Dismantling water tanks exc 250 & n exc 500 ltr capacity and removing to store.
S&F Rotational moulded polye thylene water storage(Capacity 500 Ltr) tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
Dismantling water tanks exc 500 & n exc 1000 ltr capacity and removing to store.
S&F Rotational moulded polye thylene water storage(Capacity 1000 Ltr) tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
S&F ball valves, 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) fixed in repairs.
M&L for fixing in repair 25 mm matt finish Stainless steel curtain rod best quality as approved by Engr-in-charge
M&L for fixing in repair Stainless steel socket bracket with bore of 25mm for dead end of curtain rod .
M&L for fixing in repair Stainless steel ornamental piece with bore dia of 25 mm for free end of curtain rod .
M&L for fixing in repair Stainless steel projecting bracket to support curtain rod of size 25mm.
Taking down carefully existing bituminous membrane/tarfelt treatment any description and cleaning and making good damaged surface of roof ,parapet,facia etc in cement mortar 1:3 where ever require and removing rubbish out of defence land.
Demolition of concrete (unreinforced) of any description and in any position not otherwise secifically provided for.
Providing cement concrete type B0 1:2:4(12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges.
M&L for rendering 15mm thick in CM 1:3 with intergral waterproofing compound (200 ml per bag of cement used) on roof surfaces,parapets,facias etc . Note: waterproofing compound shall be measured and paid separately.
Supplying only integral water proofing compound ISI marked complete all as specified and as directed.
M&L for Waterproofing on roof including flashing and junctions of parapet,kerb, wall etc.as under :- (a) Cleaning of plasetered roof,parapet,facia surface and applying one coat Oil based cold bituminous primer @ 0.70 kg per sqm. (b) Laying a layer of APP based polymeric membrane,3 mm thick(minimum),weighing not less than 3.60 kg/Sqm prefabricated fire layer waterproofing membrane reinforced with polyester non woven fabric(weighing not less than 160 gms/sqm) shall be applied over compatible primer at 0.40 litre/Sqm of density at 25 degree Centigrade 0.87-0.89 Kg /Litre and viscosity 70-160cps or cold sticker, application of APP modified membrance shall be by torch application. The overlaps shall be minimum 150mm on the transverse direction and 100 mm on the longitudinal direction. (c) Painting the exposed APP membrane surface with bitumastic aluminium paint @ 0.15Kg/Sqm. (d) APP membrance,Primer and bitumastic aluminium paint shall be of same brand.
Disconnecting existing tanks exc 250 n exc 500, setting aside (or lowering if required) cleaning and removing all scale dirt,etc from the mouth of circulating pipes etc and hoisting if required,reconnecting and re-fixing in position.
Disconnecting existing tanks exc 500 n exc 1000, setting aside (or lowering if required) cleaning and removing all scale dirt,etc from the mouth of circulating pipes etc and hoisting if required,reconnecting and re-fixing in position.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
Dismantling Plain or corrugated steel sheeting of any gauge,thickness,including Nainital or similar pattern roof coverings complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 Grade St-240 complete all as specified and as directed.
S&F Prepainted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/cladding to wall,fixed with self tapping screw complete all as specified and as directed. Gap between wall face and sheet if any shall be sealed using CM 1:3 with WPC.quoted rate deems to be inclusive of the same.
S&F Prepainted Galvalume aluminium zinc coating GI based Plain sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/cladding to wall,fixed with self tapping screw complete all as specified and as directed.
Taking down AC rain water pipes(any size or pattern) including all fittings,head shoes,bends,swan neck etc.
S&F PVC (SWR) pipes110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors.
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors.
M&L for PCC 1:2:4 using 40 mm graded aggregate as foundation filling and mass concrete.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and connecting up including provision of cable from ceiling rose or connector to fan all as per specified and directed by Engr-in-Charge
Dismantling unserviceable main switch/DBs with MCBs and wooden board including making good disturbed surface of wall.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
M&L for Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface for One light point controlled by one, one way switch all as directed and specified. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
All as per Item No. 104.00 above but One ceiling /exhaust fan point controlled by one switch and regulator
All as per Item No. 104.00 above but One 3 pin 5 amp socket out point on the same board with other switches.
All as per Item No. 104.00 above but One3 pin 5 amps socket out let point on independent board
All as per Item No. 104.00 above but One bell/buzzer point controlled by one bell push.
All as per same in item No.104above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
S&F Switch piano flush type single pole one way 5 amps.
S&F Socket outlet 2 in 1, 3 pin, 6A
S&F Switch socket combination 2 in 1, 6A flush type
S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body
S&F Buzzer, Ding Dong AC. 230 volts, single pole
S&F Bell push, flush type, 5 amp.
S&F Electronic regulator 100/120 Watt step type
S&F Lamp holder insulated body with back plate for angle holder including 9W LED Lamp all as per specified.
S&F in repair decorative gate/garden light made up of high grade unbreakable polycarbonate material suitable for LED lamp upto 20W B22 base including connecting up with twin core twisted flexible copper conductor cable, 10 LED lamp, foundation and housing PVC pipe etc complete all as specified and directed.
S&F in repair SP&N enclosure with 2 pole and earth metal plug & socket for incorporating 10 A / 20 A SPN / DP MCB complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F in repair 20 Watt LED Tube Light (4 feet) (Double Side Connection) Ultra bright glass with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders or lamp holders as required in site. Complete all as specified and directed.
S&F 15 Watt LED streetlight fitting luminaire made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge.
Fabrication,supply & fixing of GI pipe bracket up to 25 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15 w LED security light fitting
Taking down and fixing partly unserviceable LED downlighter/security light fitting (building) of any make and type for necessary repair including ractifing any kind of electronic disorder/Circuit disorder/replacement of LED strip/all other accessories and make it serviceable , complete all specified and directed by Engr-in-Charge. Note: (1) Ladder to be provided by contractor. (2) Spare i.e driver shall be measured seperately.
S&F in repair electronic driver 6/9/12/15 Watt suitable for downlighter/security light fittings new generation energy saving and environmental friendly long life LED downlighter/street light/building security light of any make and type, all as specified and directed by Engr-in-Charge.
M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC CASING CAPING not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit.
M&L for sub main wiring power/circuit using PVC insulated unsheathed, multistranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit.
S&F in repair Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F in replacement of Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 4 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F MCB, single pole and neutral, 240 Volts , 40-63 Amps all as specified and as directed.
S&F MCB, single pole and neutral, 240 Volts , 6-40 Amps all as specified and as directed.
S&F MCB single pole 240 Volts , 32 to 63 Amps all as specified and as directed.
S&F MCB singal pole 240 Volts , 6 to 32 Amps all as specified and as directed.
Taking down and fixing partly unserviceable surface/recess mounted LED fittings of any make and size for necessary repair including ractifing any kind of electronic disorder/Circuit disorder/replacement of LED strip/all other accessories and make it serviceable , complete all specified and directed by Engr-in-Charge. Note: (1) Ladder to be provided by contractor. (2) Spare i.e driver shall be measured seperately.
S&F in repair electronic driver upto 42W Watt suitable for surface/recess mounted LED fittings of any make and type, all as specified and directed by Engr-in-Charge.
Taking down/dismantling/handing of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape,Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, including spare parts, painting and necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items ( Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No, Condensor-01 No, bearing- 01 or 02 Nos, gun metal bush-01 No if required) and including necessary transportion to workshop, for 1200/1400MM sweeps of ceiing fan .
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed
Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed.
Taking out of centrifugal pump set from pump foundation after disconnection from motor and transportation to workshop , dismantling the pump for repair/ overhauling incluiding cleaning of all parts of pump assembly throughly, including machine work of pump shaft inorder to obtain smooth finish including necessary polishing etc and installing back including helium gasket sheet not less then 1mm thick & to the entire satisfaction of engr-in-charge all as specified and directed. Make -Kirloskar, DSM -65-32A (Note:- Spares as required shall be measure & paid seperately against the relevant items).
(a) supply & fix Casing Wear Ring-
(b) supply & fix shaft sleeve-
(c) supply & fix Inter Stage Ring-
(d) supply & fix Ball bearing DE SKF
(e) supply & fix Ball bearing NDE SKF
(f) supply & fix Bearing cartridge DE
(g) supply & fix Bearing cartridge NDE
(h) supply & fix Split Gland bush
Taking up or down GI Tubing and connections including cleaning for refixing or removal to store of size 20 mm dia.
(b) 25 mm dia
(c) 40 mm dia
Supply and laying GI tubing medium grade with all fittings and fixed complete laid in trenches of size 40mm.
Removing Unserviceable Gate valve/stop valve of water supply lines, closing the opening with plug or preparing for new as required necessary fitting complete and deposited to E/M store yard of size 20 mm dia.
(b) 25 mm dia
(c) 40 mm dia
S&F Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete of size 40 mm dia.
Taking up cast iron water mains incuding flanged rubber joints with spigot and socket ends and lead joint burning out and recovering lead of size 150MM.
Supply and laying cast iron pipes with spigot and socket ends, tyton ring, centrifugally cast, Class LA, in any length laid in trenches of size 150MM
Supply and laid spigot and socketed CI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size upto 150mm dia.
M&L for run lead joints complete for water mains with spigot & socket pipes and fittings, all as specified and directed. 150 mm Bore of pipe
S&F in repair CI sluic valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes 150 mm dia
Disconnecting electrically and disengaging the Monoblock pump set 3 phase 415 Vlots, 50 Cycles, 3 HP, 1440 RPM capacity , removing from foundations, overhauling thoroughly including complete varnishing and reinsulation replacement of DE /NDE bearings ,greasing, reassembling the monoblock pump set, mounting on the foundations, testing and commissioning all as directed. (note- Rewinding will be measure & paid seperately under relavant item of sch.)
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles,and taking out to local workshop submersible induction motor 30 HP for repair purpose including complete cleaning,varnishing ,insulation, replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. (note- Rewinding will be measure & paid seperately under relavant item of sch.)
M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr -in - charge
Supply laying & testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 95 Sqmm 3.5 Core size including taking down:-
Supply laying & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm including taking down.
S&F in repair GI water tubing 100mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenchescomplete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair MCCB of 200A, 4 pole, 50 KA,
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sqmm,
S&F in repair Cable jointing kit for 1100V (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 95 Sqmm,
Repair / Servicing / Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 250 KVA (Crompton Greaves) . checking throughly the generator and finding out its faulty/defective parts and complete servicing /replacing defective spares of the DG set including provn of engine oil of apropriate grade, FIP Calibration, FIP Overhaul, Injector Calibration & Pressure Testing, injector overhaul, cylinder head repair & valve lapping, connecting rod bend Check & bush Setting, crank shaft grinding, crank case machining & bore checking, stator servicing, rotor servicing, radiator repair & servicing, air cleaner element repair & servicing, hose repair/new hose, makeup water line, pipe (thermostat to radiator inlet), hose: air cleaner, air cleaner element, clip for breather pipe, air pipe (CAC to inlet), lube oil inlet pipe, lube oil drain pipe, pipe: thermostat to radiator, pipe: radiator to pump inlet, fuel pipe: fuel filter to FIP, fuel pipe feed pump to fuel filter, hose for air cleaner, battery cable assembly of suitable size, upper and lower clamp for pipe, V belt, fuel pipe, high pressure pipe assembly, drain pipe for lub oil sump, hose for breather, setting bush, bush for injector, valve stem seal, rubber bush, steel bush, piston ring set, valve guide etc (if required) and labour for replacement of defective spares as required to make the DG set functional in all respect. After Repair/Servicing /Overhauling of the DG Set testing will be carried out upto the entire satisfaction of Engr-in-charge. Spare partes i.e oil filter, diesel filter, air filter will be measured and paid seperately.
S&F Oil filter assembly complete, all as specified and directed by Engr-in-Charge of capacity 250 KVA.
S&F diesel filter assembly complete, all as specified and directed by Engr-in-Charge of capacity 250 KVA
S&F air filter assembly complete, all as specified and directed by Engr-in-Charge of capacity 250 KVA
NOTE: - AMOUNT OF SCHEDULE OF CREDIT RS.47,419.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
M/S SAMEER SUBHASH PATANI
Abhiraj Enterprises
MAHIMA CONSTRUCTION
Bidder Name
MAHIMA CONSTRUCTION
M/S SAMEER SUBHASH PATANI
Abhiraj Enterprises
MANOVANDANA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .