PATCHHARA GP OFFICE PATCHHARA, COOCHBEHAR PIN 736157
CONSTRUCTION OF ELEVATED DRINKING WATER TANK ELECTRIC POWERED AT PATCHHARA AWC AT SANSAD XV UNDER PATCHHARA GP WITHIN COOCHBEHAR I BLOCK IN THE DISTRICT COOCHBEHAR ACTIVITY ID 109281030
2026_ZPHD_1009088_4
NIT NO 10/PAT/2025-26, DATED 13.02.2026, SL NO 01
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
PATCHHARA GP AREA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹4,117
Yes
5 Mar 2026
18 Feb 2026
26 Feb 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
DRINKING WATER TANK WITH SOLAR AT JHALJHALI A.P SCHOOL
Earth work in excavation of foundation trenches or drains,in all Sorts of soil (including mixed soil but excluding laterite or Sandstone) including removing,spreading or stacking the spoils Within a lead of 75m. As directed .the item includes necessary Trimming the sides of trenches, levelling, dressing and ramming The bottom, bailing out water asrequired complete. a)Depth of excavation not exceeding to 1500mm
Earth work in filling in foundation trenches or plinth with good Earth, in layers notvexceeding 150mm. Including watering and Ramming etc.layer by layer complet.( payment to be made on the The the basis of measurement of finished quantity of work)
Single brick flat soling of picked jhama bricks Including ramming and dressing bed to proper level and filling Joints with local sand.
Cement concrete with 30 mm down graded shingles Excluding shuttering, In ground floor. (a)1:3:6 proportion
Ordinary Cement concrete (mix1:1.5:3) with gradedStone chips (20mm nominalsize) excluding Shuttering and reinforcement, if any, in gound floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correctshape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. SAIL/TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curvedor straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) (ii) With 4:1 cement mortar (c) 10 mm. thick plaster
Neat cement punning about 1.5mm thick wall dado, window sills, floor, drain etc.
Labour for boring tube well of required dia, by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. For depth upto 150 metre for 50 mm dia. tube well with top 50mm dia. Boring etc.
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI Pipes as per IS: 1239 (Part -1). (A) PVC Pipes 50 mm dia
Supplying PVC strainer of approved make with adapter conforming to 1.S.12818 specifications.
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer a) 1000 litre capacity
Labour for hoisting plastic water storage tank. Upto 1500 litre capacity. a) Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq.cm. 50 mm
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. 50 mm dia
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816-1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007. with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. 25 mm dia
Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. On steel or other metal surface
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: With super gloss (hi-gloss) - Two Coats except white in shade
R.C.C. well ring made with cement concrete 1:1.5:3 with stone chips and 0.80% reinforcement (including the cost of shuttering and reinforcement) cast at site fitted and fixed in position after proper curing true to plumb in the well including jointing with cement mortar 1:2 complete as per direction. a) 65 mm thick and 0.9 metre internal dia.
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL............................. etc. as per direction of the Engineer-in-Charge.
Supplying, fitting fixing & installation of Iron Removing filter plant ca[pacity 1500LPH IR media filter working-downilow Max flow Rate 3m3 /hr, working presure 1-3 kg/cm2 size 13''x54'' (BIS Standarts & Including 1 year warranty)
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour harges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in al respect as per direction.
Supplying, fitting, fixing CPVC (Chloninated polyvinyl Chloride) pipes of approved make conforming to IS-15778:2007 with all necessary accessories, specials viz socket, bend, tee, union, cross, elbo, nipple longscrew, reducing socket, reducing tee etc fitted with holder bats, including cutting pipes, fitting, fixing etc complete. (ii) CPVC Pipes b) CPVC pipes Class - 1, SDR-II iii) 25 mm Dia
Supplying and installation, testing & lowering of 1 HP & 3 IQ mono pump set having suitable discharge as per yeild test oe well .... As per manufacturers specification and water testing for bacteriological and chemical from any depth at any time during execution of work.
C) CPVC pipes Class - 1, SDR-II iii) 15 mm Dia
Add GST Charges @ 18% of Total cost
Add L/welfare cess @ 1.0% of Total including GST
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_2477254.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .