Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹17.7 L+₹2.3 L (14.9%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹18.4 L+₹3.0 L (19.4%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹18.9 L+₹3.5 L (22.8%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹21.0 L+₹5.6 L (36.4%)Rejected-AOC B 17 SHRIRAM INDUSTRIAL ESTATE G D AMBEKAR ROAD WADALA MUMBAI CITY MAHARASHTRA 400031 | MUMBAI | MAHARASHTRA | 400031 | L5 | Rejected-AOC REJECTED |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
13 Mar 2024, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
SPECIAL REPAIRS FOR REPLACEMENT OF LT UNDER GROUND CABLES,FROM ZONE B TO MAIN PUMP HOUSE ,ZONE A TO ZONE B AND NSB AREA AT INS HAMLA UNDER GE(NW) BHANDUP
2024_MES_641885_1
8324/B
Open Tender
Civil Works
Item Rate
180 days
Hamla
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹48,000
Yes
7 Jun 2024
12 Feb 2024
14 Mar 2024
12 Feb 2024
13 Mar 2024
28 Feb 2024
12 Feb 2024 - 22 Feb 2024
Amount
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed by the Engineer-in- Charge.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and as directed. Note : [Punned thickness 18 cm shall be measured & paid]
Supply and laying DWC (double wall corrugated) HDPE pipes of pressure rating 6 Kg/Cm sq of size 32 mm (internal dia) laid in trenches complete all as specified and directed.
Supply and laying DWC (double wall corrugated) HDPE pipes of pressure rating 6 Kg/Cm sq of size 50 mm (internal dia) laid in trenches complete all as specified and directed.
Supply and laying un-reinforced pre cast concrete cable cover, class LV type 1 with flat size 250mm x 150mm x 40mm complete all as specified and as directed.
Supply and laying GI pipe 80 mm, light grade for the protection of the cable passing through road crossing, etc. complete all as specified and as directed.
Supply and laying GI pipe 100 mm, light grade for the protection of the cable passing through road crossing, etc. complete all as specified and as directed.
Supply and laying in repairs cable LT XLPE 400 Sqmm 3.5 Core insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge including taking down existing u/s LT cable.
All as per item No.10 above but for 95 Sqmm 3.5 Core
All as per item No.10 above but for 70 sqmm 3.5 core
All as per item No.10 above but for 50 Sqmm 3.5 Core.
All as per item No.10 above but for 35 Sqmm 3.5 Core.
All as per item No.10 above but for 25 Sqmm 3.5 Core.
All as per item No.10 above but for16 Sqmm 4 Core.
All as per item No.10 above but for 10 sqmm 2 core
Supply and fix in repairs LT cable route indicator made out of cast iron 10cm dia duly engraved with letters 'LT CABLE 1100 volts' fixed in 20mm x 20mm equal angle 60cm long including provision of PCC block of 20cm x 20cm complete all as specified and directed.
M & L for Premix Ready mix road repair patching Compound for repairs to damage road any depth,including sweeping free from dust and mud or water,scouring sunken surfaces in roads,paths etc,cutting around edges to at least 25 mm in depth,filling in screened and graded road metal,watering and well ramming etc complete all as specified and directed.(For Road Cutting Repair)
Material and labour for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) for filling the disturbed road opening for cable crossing include levelling with road surface and smooth finishing complete all as specified and directed.(for Road Cutting Repair)
Deduct Credit for Demolished/ Dismantled material Rs. (-) 123267.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
M/s Mukesh Engineers
Shree Ayyappa Engineering
NANGIA AND CO
Urja Techniques India Pvt. Ltd.
ELECTRO ASSOCIATES
AGRAWAL ASSOCIATES
M/s. Deepak Traders
VAIBHAVI ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .