Loading…
Loading…
Tender Value
₹5.5 Cr
EMD Value
₹11.1 L
Closing Date
29 Jun 2026, 3:00 pm
Provision of Lifts at Railway Platforms ( at BLY, SHE, CGR, BWN, BHP & RPH Stns ) over Howrah Division in connection with Amrit Bharat station development project.
EL-HWH-25-21-3633
EL-HWH-25-21-3633
Open
180 Days
Howrah, West Bengal
₹0
₹11.1 L
6 Jun 2026
6 Jun 2026
15 Jun 2026
A-Provision of Lifts at Railway Platforms ( at BLY, SHE, CGR, BWN, BHP &
Design, manufacture and supply of Machine Room / Machine Room Less ( MRL ) (As per site condition), Gearless type operation Passenger Lift ( G + 1 ), 2 Stops, 2 Openings ( opposite / same side opening as per site requirement ), 14 Passenger capacity ( 952 Kgs ) with following features :- Load & Speed - about 952 Kgs @ 1M/Sec complete with Variable Voltage Variable Frequency (VVVF) drive, Automatic Rescue Device ( ARD ) with battery backup, Electromagnetic type Breaking arrangement with brake liners and DC Voltage energization and spring tension closing, Driving Motor : PMSM (Permanent Magnet Synchronous Motor), Driving Ropes : Ropes with 1 factor of safety 12 or above, Electrical Safety - 3 phase limit switch to protect against over travel, Single phasing preventer with a protection against phase sequence reversal, Full proof gate locks for landing doors, Car gate switch, Over speed Governor, Over speed safety device. Lift car comprises with SS Cabin hair line finish Car enclosure and centre opening hair line finish door, also furnished with UPS based Lithium-Ion Battery operated Emergency Light, LED Lights, Car ventilation automatic ON/OFF Fan, Alarm, Digital floor Indication, Push Button for each floor, On/Off switch, Fan switch, IP based CCTV camera inside lift car along with web based and mobile application for monitoring the footage alongwith all type data transferring facility to IR-Niyantrac platform via RS-485 port including all other associated accessories complying RDSO specification No. RDSO/2013/EM/SPEC/0016 (Rev '2') -2025 dated 25.09.2025 or latest complete with installation, testing and commissioning of above Lift including related civil work and scaffolding.19 Above/
Supply of MCCB with Microprocessor Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) All Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication, suitable for Release Range 25-63A, 4 Pole with metal enclosure alongwith Static Multifunction panel mounting Energy Meter suitable for operation on 3 Ph, 415V, 50Hz supply system similar to LK (L&T) model : MFM 4410 LED meter Cl 1 with RS485 - 1 no. or equivalent, CTs of suitable ratio for MFM - 3 nos., LED indication lamps for Phases and "ON & OFF" indication for breaker including fixing, connection, testing and commissioning. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells QTRON ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) Above/
Supply of cubicle LT panel boards, made of 14 SWG (2mm) MS sheet duly powder coated for APFC Capacitor Bank consisting with the following : a) Super Heavy Duty Capacitor ( MPP ) suitable for 3 Ph, 440V, 50 Hz supply system (25 KVAR x 4 nos.) - 100 KVAR b) Power Factor Controller similar to EPCOS Model No. BR 6000 series or equivalent including CT's - 1 no. c) Capacitor 3 Contactor suitable for operation on 3 Ph, 440V, 50 Hz supply system suitable for 25 KVAR capacitor - 4 nos. d) MCCB, TP, 320-400A, 415V, 50 Hz, 50 kA - 1 no. Complete with CTs, Ammeter, Voltmeter, Selector Switches for ammeter and voltmeter, LED indication lamps for Phases and ON / OFF indication for breaker including fabrication and copper banking ( Make for Capacitor - EPCOS / ABB / Siemens / Keltron / Havells / Alcon / Usha ) ( Make for Power Factor Controller and Contactor etc. - LK (L&T) / Siemens / ABB / Schneider / EPCOS / Havells ) ( Make for MCCB etc. - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells QTRON ) ( Make for Meters - Secure / LK (L&T) / Genus / Conzerv / Selec / Rishabh / Socomec / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing, suppply and connection of current feedback CTs and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories Above/
Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) along with refilling the trench and make good of surface as its original condition ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable under ground by soil cutting through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) Above/
Laying of cable underground through 100 mm diameter HDPE pipe by Micro Tunneling cable laying method including supply and jointing of HDPE pipe (PE-100 grade, PN-10 or higher). ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting and 9 commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) Above/
Trenching, laying under road / track through 100 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) Above/
Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) Above/
Supply of heavy gauge GI fabricated Cable tray with GI supporting structure and GI nut-bolts and washer of suitable sizes as per site requirement including fixing and commissioning. Above/
Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 50-95 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) Above/
Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 120-185 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) Above/
Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 225-300 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) Above/
Releasing of old, unused LT cables of various sizes Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 18 grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 19 grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS 20 grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for 03 phases and 01 neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 21 grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 22 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 23 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Multi Plug board consisting with three nos. 6A / 3 pin plug socket, three nos. 24 6A switch, one no. 6/16A 3 pin plug socket, one no. 16A switch, one no. 10A fuse kit-kat / MCB and one indicator ( Red ) by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq. mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Extra cost for conceal wiring in respect to PVC conduit / casing for light, fan, plug, power plug, multi-plug point etc. including make good of wall surface as its original condition Above/
Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition Above/
Extra cost involvement for modular switch, bell push, plug socket, fan regulator, USB point, TV socket etc. with other accessories ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) Above/
Designing of mounting layout, supply, installation, connection and commissioning of 20-22W LED batten (Type of LED - Surface Mounting Device ) tube with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, extruded aluminium housing and milky polycarbonate diffuser ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, 32 Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), LED luminaire system efficacy - Greater than 120 Lumens per Watt @ 350mA drive current, Colour Temperature - 6500K (Cool white), CRI>80, SDCM<5, Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD<10%, Driver HV Cut off @ 325V/440V (P2P) protection for 8 hrs., Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and indivi- dually BIS approved with 60 months warranty including fixing with GI clamps made of GI flat of suitable size & GI nut-bolts. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) Above/
Designing of mounting layout, Supply, installation, connection and commissioning of Recessed mounting Circular type 12W LED luminaire (for mounting in false ceiling), Color 33 temperature- 3000 K, SMD type LED Chip as per LM 80/IS16106, LED chip Efficacy >/=110 Lm/Watt for 6000 K,( LED make - Nichia, Osram, Seoul, Philips, Lumileds, Avago, Cree ) complete with all accessories, operating voltage and frequency range 140V to 280 V at AC 50 Hz,Driver Efficiency >/=85%, Life span of LED chip -Greater than 50,000 burnings hours as per LM-80 report and minimum 2 years free replacement warranty including fixing with G. I. clamps made of G. I. Flatof suitable size & G. I. Nut, bolts etc. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) Above/
Supply of Indoor LED Trunking light system consisting with extruded aluminium housing ( for 1200 mm length ) with associated accessories and 40 Watt trunk mounted LED luminaire ( Type of LED - Surface Mounting Device ) with industrial grade constant current driver ( Efficiency - Greater than 90% ) with short circuit protection, aluminium housing and milky polycarbonate diffuser ( Make / brand of LED chip - NICHIA, OSRAM, SEOUL, PHILIPS, LUMILEDS, EVERLIGHT, AVAGO, CREE, LEDNIUM, APT Electronics & BRIDGELUX ), LED luminaire system Efficacy - Greater than 130 Lumens per Watt, Ingress Protection - IP54 or higher, SDCM<5, CRI>80 with Colour Temperature - 5700K to 6500K (Cool white), Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD< 10%, Power factor >0.95, Driver HV Cut off @ 325V/440V (P2P) protection for 8 hrs., Life span of LED chip Greater than 50000 hours, The Luminaire & Driver both should be off same make/ brand and individually BIS approved with 60 months warranty and all other accessories suitable for surface / suspended mounting as per site condition. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) Above/
Fixing, connection, testing and commissioning of above luminaire fittings with suitable arrangement and necessary cables etc. Above/
Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, Philips, 36 Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) Above/
Supply of AC Exhaust Fan 380 mm sweep 4 pole suitable for operation on 1Ph, 220- 250V, 50 Hz supply system without louver Shutter including fixing, connection and commissioning with GI clamps made of GI flat of suitable size & GI Nut-Bolts alongwith necessary masonry works. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) Above/
Supply of AC Wall Bracket Fan 400 mm sweep suitable for operation on 1Ph, 220- 240V, 50 Hz supply system including fixing, connection and commissioning with GI clamps made of GI flat of suitable size and GI Nut-Bolts on wall / structure. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) Above/
Supply of Bracket type Air Circulator Fan ( metal ) of sweep 600 mm suitable for operation on 1Ph, 230V, 50 Hz supply system including fixing, connection and commissioning with GI clamps made of GI flat of suitable size and GI Nut-Bolts on wall / structure. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) Above/
Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance 40 IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) Above/
Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- 41 extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 26 Modules or equivalent ), 3Ph, 50Hz, 415V, 6 way per phase, 415V, 50Hz, complete with total 18 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) Above/
Fixing, connection, testing and commissioning of above TPN MCB DB including all incoming and outgoing cables glanding, cable connection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. Above/
Supply of SPN DB ( Metal Enclosure with Metal Door ), 14 way, 50Hz, complete with 10 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 63A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) Above/
Supply of SPN DB ( Metal Enclosure with Metal Door ), 10 way, 50Hz, complete with 6 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) Above/
Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. Above/
Supply of Dust and vermin proof metal Busbar Chamber made of 16 SWG ( 1.6mm ) 46 MS sheet duly powder coated consisting of 4 nos. tinned copper busbar of each bar of capacity 100 Amp, 4 way, suitable for 415V, 50Hz supply system including all accessories alongwith fixing, connection, testing and commissioning of incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement. ( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) Above/
Supply, fixing, connection, testing and commissioning of MCCB with Microprocessor 47 Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory 7) All Microprocessor protection-based MCCB / ACB must have facility of individual 'LSIG' fault indication, suitable for Release Range 40-100A, 4 Pole including metal enclosure with internal wiring. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells QTRON ) Above/
Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 700 x 480 x 48 210 mm ( IP-55 ) / equivalent dimension heavy duty, Outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket, by replacing existing damage box and accessories with testing and commissioning ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) Above/
Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 450 x 375 x 200 mm ( IP-55 ) / equivalent dimension heavy duty, Outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket, by replacing existing damage box and accessories with testing and commissioning ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) Above/
Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 250 x 250 x 50 155 mm ( IP-55 ) / equivalent dimension heavy duty, Outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket, by replacing existing damage box and accessories with testing and commissioning ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) Above/
Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 ) Amp, 4 Pole - 1 no. b) Power Contactor, 4 Pole, 51 100A, 415V, 50Hz - 2 nos. c) Astronomical Timer Switch - 2 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 200 Amps., 415V, 50 Hz - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no. f) CT of suitable ratio for MFM - 3 nos. g) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 12 nos. h) Petty store like cable gland, socket, fuse etc. - 1 job complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells QTRON ) ( Make for Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories. Above/
Supply of LT 6 Way VTPN/ SMDB Wall Mounted Double Door Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder comprising with the following items :- a) MCCB, 4 Pole, ( 63 - 160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 1 no. b) MCCB, 4 Pole, ( 25 - 63 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above mentioned features in (a) - 4 nos. c) RCBO, 2 Pole, 10 Amp, 240V, 50Hz, 10kA, Sensitivities - 300 mA - 4 nos. d) Tinned Copper Busbar (4 Bar) each of capacity 200 Amps., 415V, 50 Hz - 1 set e) Static Multifunction panel mounting LED Energy 53 Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 5 nos. f) CT of suitable ratio for MFM - 15 nos. g) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 26 nos. h) Petty Store for control cable, MCBs, gland, socket, fuse, push button, spreader terminals, auxiliary contacts, shunt release, terminal blocks etc. - 1 job. i) Fabrication work for above panel - 1 job. complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells QTRON ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Stelmec / HPL / Socomec / Anchor / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories. Above/
Supply of LT Wall Mounted/ Floor Mounted Double Door Cubical Outdoor type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder comprising with the following items for 100 KVA to 125 KVA Load :- a) MCCB, 4 Pole, ( 40 - 160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 2 nos. b) MCCB, 4 Pole, ( 25 - 100 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release similar to iTRP3 type of LK (L&T)-make or equivalent with above mentioned features in (a) - 4 nos. c) MCCB, 4 Pole, 160 Amp, 415V, 50Hz, 36kA, without protechtion release, used as Bus Coupler isolation - 1 no. 55 d) RCBO, 4 Pole, 32 Amp, 415V, 50Hz, 10kA, "Sensitivities - 300 mA , Suitable for AC + Pulsating " DC (Type A) + Harmonics - 2 nos. e) RCBO, 4 Pole, 63 Amp, 415V, 50Hz, 10kA, "Sensitivities- 300 mA , Suitable for AC + Pulsating " DC (Type A) + Harmonics - 4 nos. f) Tinned Copper Busbar (4 Bar) each of capacity 300 Amps., 415V, 50 Hz. - 1 set. g) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 communication port having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 6 nos. h) CT of suitable ratio for MFM - 18 nos. i) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 38 nos. j) Petty Store for control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays etc. - 1 job. k) Fabrication work for above panel including internal wiring - 1 job. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells QTRON ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories Above/
Dismantling, Shifting, reinstallation, testing and commissioning of existing LT/HT distribution panel board/ Transformer including all incoming and outgoing cable connection Above/
Dismantling of old wiring including light, fan, call bell, plug, power plug, sub-main and main of different types of quarters/rooms/PF shed etc including transportation of release materials from site to stores. Above/
Dismanting / cutting of existing pole and make good of surface including transportation from site to stores Above/
Drawing / Relocation of cable through cable tray / wall / shed structure by GI clamp or suitable arrangement Above/
Dismantling of old light fittings from High Mast Tower / Pole / Structure / surface / PF shed with suitable arrangement including transportation of release materials from site to stores. Above/
Disconnection, dismantling and releasing of existing LT overhead conductor bunch (consisting with four / five / six conductors ) with all other accessories from pole including transportation of released materials from site to store Above/
Supply of MCB Change Over Switch, 40A, 4 Pole enclosed in sheet enclosure including fixing, connection, testing and commissioning ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) Above/
Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T / Siemens / ABB / Hager / Legrand / Schneider and Enclosure Board - Grasp / OBO Bettermann / ABB / Schneider ) Above/ Square
Design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape.The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness.The text / graphics matter visibility shall not be 65 less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust.The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided . Above/ Square
Erection and installation of wall /hanging / floormounting type LED illuminated sign / directionboards in half elliptical shape. The display sheetshall be of unbreakable 040 translucent polycar--onate sheet of 2 mm thickness. The text / gra--phics matter visibility shall not be less 66 than160 deg. The approved colour text and raphicsshall be printed / router cut on monomeric calen-- dered inyl of 70 um thickness and shall be firmlypasted on display sheets. The mounting arrange-- ment shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting andas per iterequirement. The signage shall havethe integral mounting arrangements with turdy structural frame and ACP cladding on the backside of the signage to avoid rusting and entry ofdust. The LED board shall have uniform illumina--tion with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5mm thick SS 304 should be provided. Above/
Supply of Maintenance Free Copper Bonded Solid Earthing Rods with 25 kg Earth Enhance Compound with below specifications : a) Certified by CPRI and NABL Accredaited Lab b) 67 ROHS certified c) Low Carbon High Tensile Rod d) Length of Electrode 3000 mm (3 Meter) e) Rod dia 17.2 mm f) Molecular Copper Plating thickness 254 microns as per UL 467 g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washer including installation, testing and commissioning as per RDSO spec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann / JMV LPS ) Above/
Supply of Heavy Duty Fiber Reinforced Polymers Pit Cover with below specifications : a) Weight Carrying Capacity 5 Ton b) Lockable arrangement c) Top Dia 162 mm d) Bottom Dia 242 mm e) Height 230 mm f) As per IEC 62561-5 g) M5 Nut Bolts HDG 4.6, 30 mm length with 2 nos. of plain washer h) Tested by NABL Accrediated LAB including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann / JMV LPS ) Above/
Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) Above/ 8451865.0
Goods & Services Tax ( at present @ 18% )
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
GeneralTenderClause.pdf
ATTACHMENT
Annexure-1.pdf
ATTACHMENT
Annexure-A.pdf
ATTACHMENT
19nosliftBooklet.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
finalPassengerElevatorsignedRDSOREV- RDSO Spec
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
RDSOSpec.-2025-09-25-finalPassengerElevatorsignedRDSOREV-2.pdf
ATTACHMENT
Download all tender documents and submit your bid