Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹42.9 L+₹5,600 (0.13%)Rejected-Finance NO 403 BENGALI COLONY RANJHI JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹46.3 L+₹3.4 L (7.94%)Rejected-Finance R O 24 GOKALPUR MAIN ROAD JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Highest amount quoted |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Oct 2023, 6:00 pmClosed
Shri Justin O A, AE (Civ)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
REPAIR OF ROOF, SUNKEN FLOOR, FALSE CEILING, RAIN WATER PIPE ETC OF RESTRICTED AREA OF COD UNDER AGE B/R-II OF GE (EAST) JABALPUR
2023_MES_617650_1
8574/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹80,000
Yes
9 Jan 2024
15 Sept 2023
21 Oct 2023
15 Sept 2023
19 Oct 2023
30 Sept 2023
15 Sept 2023 - 22 Sept 2023
Amount
RESTRICTED AREA SCHEDULE
Taking down cement or cement lime plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for Water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate as in covings/benching and padding for maintaining slopes where required over slabs n.exc 15 cm thick including necessary form work and finishing the exposed surfaces even without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering on roof surfaces/concrete surface in CM 1:4 complete all as specified and directed.
Supply only intergral water proofing compound (ISI Mark) complete all as specified and directed.
Supplying and providing water proofing treatment over cleaned roof/chajja/vertical surface with 3mm thick polymeric standard water proofing APP membrane weight not less than 3 kg/m2 comprising of the following for non approachable roof including cleaning, sweeping and washing with water to remove all dust etc from the plastered roof surfece or walls applying a coat of hot air blown bitumen of grade 82/25 confirming to IS 702 @ 1.20 kg/m2 over a coat of bitumen primer @ 0.3 kg /m2 on prepared surface weight of APP membrane not less than 3 kg/m2 with 100 mm over laps with sides and end . the over lap shall be sealed flame including with vertical surface after cutting necessary grooves and making good with PCC gala 1:2:4 type B1 etc adhere to hot blown bitumen all as per manufacturere instruction (i) over membrane applying a coat of hot applying bitumen of grade 85/25 confirming to ISD 702 @ 0.75 Kg/sqm binding material such as dry condition minimum shall be dusted over bitumen including cement slurry 3Kg/Sqm, including two coat of aluminium paint complete all as specified and directed.
Supplying and providing water proofing treatment over cleaned roof/chajja/vertical surface with 3mm thick polymeric standard water proofing APP membrane weight not less than 3 kg/m2 comprising of the following for approachable roof including cleaning, sweeping and washing with water to remove all dust etc from the plastered roof surfece or walls applying a coat of hot air blown bitumen of grade 82/25 confirming to IS 702 @ 1.20 kg/m2 over a coat of bitumen primer @ 0.3 kg /m2 on prepared surface weight of APP membrane not less than 3 kg/m2 with 100 mm over laps with sides and end . the over lap shall be sealed flame including with vertical surface after cutting necessary grooves and making good with PCC gala 1:2:4 type B1 etc adhere to hot blown bitumen all as per manufacturere instruction (i) over membrane applying a coat of hot applying bitumen of grade 85/25 confirming to ISD 702 @ 0.75 Kg/sqm binding material such as dry condition minimum shall be dusted over bitumen including cement slurry 3Kg/Sqm, including two coat of aluminium paint complete all as specified and directed.
Applying two coats of bituminous base aluminium paint including preparation complete all as specified and directed.
M&L for PCC tiles 250 x 250 x 22mm thick machine pressed, laid over and including 15mm thick CM 1:4 and jointed with filler polymer based compound complete all as specified and directed.
Dismantling water tanks capacity exc 250 Ltr but n.exc 500 Ltr and removing from site complete all as specified and directed.
Dismantling water tanks capacity exc 500 Ltr but n.exc 1000 Ltr and removing from site complete all as specified and directed.
S&F 500 Ltrs capacityrotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Ltrs capacity complete all as specified and directed.
Dismantling water tanks capacity exc 1000 Ltr but n.exc 2000 Ltr and removing from site complete all as specified and directed.
S&F 2000 Ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed.
Disconnecting existing tanks exc 250 Ltr but n.exc 500 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc & hositing if required reconnecting & re-fixing in position (cleaning repairing etc measured separately) complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. & hositing if required reconnecting & re-fixing in position. (Cleaning repairing etc. measured separately).exc 500 & n exc 1000 litres
Disconnecting existing tanks exc 1000 Ltr but n.exc 2000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc. & hositing if required reconnecting & re-fixing in position. (Cleaning repairing etc. measured separately) complete all as specified and directed.
Cleaning & removing all scale & dirt, etc. from tanks & form mouths of circulating pipes, etc.exc 250Ltr but n.exc 500 Ltr complete all as specified and directed.
Cleaning & removing all scale & dirt, etc from tanks & form mouths of circulating pipes, etc exc 500 Ltr but n.exc 1000 Ltr complete all as specified and directed.
Cleaning & removing all scale & dirt, etc from tanks & form mouths of circulating pipes, etc exc 1000 Ltr but n.exc 2000 Ltr complete all as specified and directed.
Taking down steel tubing and connections including cleaning for refixing or removal form site for 15mm bore pipe complete all as specified and directed.
Taking down steel tubing and connections including cleaning for refixing or removal form site for 20 mm bore pipe complete all as specified and directed.
S&F 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
S&F 20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Refixing 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Refixing 20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Dismantling of plain/ corrugated steel sheeting, fibre glass sheet any gauge, thickness, including nainital or similar pattern roof covering complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 0.63 mm galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screw and washers, in roofs, walls etc with grade of zinc coating 275 fixed with 'L' type or 'J' type or cranked hook bolts in lieu of screw complete all as specified and directed.
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
S&F 6mm thicks asbestos cement sheet corrugated or semi -corrugated sheets in roofs, wall, fixed with L-type or J-type or cranked hook bolts complete all as specified & directed.
Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed.
Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in lime mortar 1:3 or CM 1:6 complete all as specified and directed.
Repairing sunken floor leakage as per following steps :- Surface preparation :- (i) Prior to application of Dr fixit powercrite, ensure to clean the substract which shoud be free from all the dust, foregn particles, loose aggregate and oil grease etc. This can be done with the help of scarifying, grinding water jetting and sand blasting etc. (ii) The surface should be wetted well prior to application throughly with water to get SSD condition. (iii) All the depression or pin holes/pot holes to be repaired using Dr Fixit powercrete method mortar in mixing ratio of (1 kg cement: 1.50 kg silica sand : 0.50kg of Dr Fixit powercrete). Coating application :- (i) Mix Cement with Dr. Fixit Powercrete in ratio of 1 : 0.50 (1 kg cement OP C53 : 0.50 Dr. Fixit Powercrete ) by weight. (ii) The mix should be stirred thoroughly until smooth homogeneous paste is obtained. (iii) Apply first coat over SSD /wet condition substrate. (iv) Apply and unroll woven glass fibre cloth evenly on the wet coating before it dries out on larger areas. (v) Using a nylon brush, apply one coat of Dr. Fixit Powercrete coating over the glass fabric so as to cover the fabric, allow 5-6 hours of air drying before application of another coat of Dr. Fixit Powercrete slurry coating over the surface. (vi) Provide polymer modified protective plaster of 15-20 mm thick over the coating to ensure safety from mechanical damage. Curing :- (i) Allow Dr. Fixit Powercrete coating to air cure for 3-6 hours after the final coat. (ii) Do not allow the rapid drying of the coating by covering the coating with help of polythene sheet in case of high humidity and windy condition. (iii) However, a moist curing after the air drying is advisable. (iv) Following the moist curing, Dr. Fixit Powercrete coating shall be allowed to air cured for 3 days before submerging it in water.
M&L for PCC 1:5:10 type E-2 using 40 mm graded crushed stone aggregate in foundations, filling and mass-concrete complete all as specified and directed.
Taking down of eves gutter, rain water pipes of any size or pattern including all fittings etc complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
S&F 100mm dia Stack clampsout of 50 mm by 5 mm flat iron and 16 mm dia around iron stays including bolts and nuts and securing ends of stays to wall or roof making good all respect complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) branch pices (single Y) equal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) branch pices (single Y) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (double T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (double T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
M&L for PVC (SWR) floor trap 75 mm, setting and jointing with solvent cement complete all as specified and directed.
M&L for PVC (SWR) mulit trap 75 mm, setting and jointing with solvent cement complete all as specified and directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in repair 20 mm sizeWire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intemediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasters with and incl ceiling section (not exc 1.2m lenght) of 0.55mm thickness having kuried web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed.
M&L for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long & 450 mm c/c complete all as specified and directed.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions.
M&L for two coats of OBD over a coat of alkali resistant primer over a coat of 3mm thick wall care putty after preparation of surfaces on ceiling surfaces complete all as specified and directed.
S&F non asbestos fibre cement board of size 6 mm thick (HPSC)building board size 600mm x 600 mm fixed or laid/inserted to timber/GI/Aluminium framework with screws & Fixing flat or sloping complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling all as specified 605 x 605mm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.11 sqm but n.exc 0.18sqm, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic tiles of size 350 x 250 x 7mm/ 450 x 300 x 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (12.5 mm size aggergate) as in floors as sub base using extra cement in patches complete all as specified and directed.
Schedule of credit amount of Rs. 2,97,100.00 to be deducted during AOC.
J.P ENTERPRISES
m/s R K SETHI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .