Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.2 LAdmitted-Finance | -42.56% | ₹14.2 L | L1 | Admitted-Finance |
| 2 | L2₹14.4 L+₹25,893.42 (1.83%)Admitted-Finance | -41.51% | ₹14.4 L+₹25,893.42 (1.83%) | L2 | Admitted-Finance |
| 3 | L3₹16.5 L+₹2.4 L (16.6%)Admitted-Finance | -33.01% | ₹16.5 L+₹2.4 L (16.6%) | L3 | Admitted-Finance |
| 4 | L4₹18.9 L+₹4.7 L (33.5%)Admitted-Finance | -23.30% | ₹18.9 L+₹4.7 L (33.5%) | L4 | Admitted-Finance |
| 5 | L5₹19.0 L+₹4.8 L (34.1%)Admitted-Finance | -22.99% | ₹19.0 L+₹4.8 L (34.1%) | L5 | Admitted-Finance |
Tender Value
₹24.7 L
EMD Value
₹49,320
Closing Date
29 Jun 2026, 6:00 pmClosed
EE (ELECT-I) JDA JAIPUR
EE (ELECT-I) JDA JAIPUR
Providing and Fixing of High Mast Lights at Mahal Road U Turns, JDA, Jaipur.
2026_JDAJP_568760_1
EE (ELECT-I)/05/2026-27
Open Tender
Electrical Works
Percentage
60 days
JDA AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
ONLINE JDA WEBSITE
₹49,320
Yes
6 Jul 2026
17 Jun 2026
3 Jul 2026
17 Jun 2026
29 Jun 2026
17 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 1.1 | 2 x 2.5 sq.mm | - | Mtr. | 61 | - |
| 2P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 2.1 | 50mm x 50mm x 6mm | - | Mtr. | 551 | - |
| 3Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 3.1 | Single pole MCB (With B/C curve tripping Characteristics) | - | - | - | - |
| 3.2 | 6A to 32A rating | - | Each | 187 | - |
| 4SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- | |||||
| 4.1 | (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided | - | - | - | - |
| 4.2 | (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
05TDHighMastLightsUTRUNS.pdf
Tender Documents • 7.31 MB
BOQ_1011808.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .