Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹5.4 L
Closing Date
9 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Replacement of existing signaling gears (PI) with Electronic Interlocking System (EI system) at Bela stations in PNBE-GAYA section under Danapur Division.
DNRSandTSig2026-1~ECR
DNRSandTSig2026-1
Open
Works - General
12 Months
Patna, Bihar
₹0
₹5.4 L
9 Feb 2026
17 Jan 2026
26 Jan 2026
84 items across 2 schedules · ₹26,45,727.65 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Excavation of trench in all kinds of soil and refilling of trenches (1.0 Mtr. Depth 300 mm width)-Without bricks | Metre | 8000.00 | 9 | 72,000 |
| 2 | Excavation of trench in all kinds of soil and refilling of trenches (0.5 Mtr. Depth 300 mm width) - Without bricks | Metre | 500.00 | 8 | 4,000 |
| 3 | Excavation, trenching, earth work and reinstatement of track while track crossisng. | Metre | 100.00 | 35 | 3,500 |
| 4 | Reinstatement of platform and repairing to orginal state after cable laying work. | Metre | 100.00 | 100 | 10,000 |
| 5 | Laying cable of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender.- 2 core to 12 core signalling cable. | Kilometre | 80.00 | 2,900 | 2,32,000 |
| 6 | Laying cable of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender- Telecom Cable -Quad cable | Kilometre | 8.00 | 3,000 | 24,000 |
| 7 | Supply and fixing of G.I. Pipe with threaded collars of 100 mm nominal bore specn.No.IS 1239 medium grade. Perforated of required length on bridge/below metalled road/L-Xing/Culvert as per technical specification of tender.- Supply portion for the G.I.Pipe & collars. Supply- Inspection-Consignee | Metre | 100.00 | 335 | 33,500 |
| 8 | Supply and fixing of G.I. Pipe with threaded collars of 100 mm nominal bore specn.No.IS 1239 medium grade. Perforated of required length on bridge/below metalled road/L-Xing/Culvert as per technical specification of tender.- Execution with remaining miscelleneous materials | Metre | 100.00 | 15 | 1,500 |
| 9 | Supply of CLS Post 4.5 mtr. and Ladder 4.5 Mtr. With bases as per RDSO DRG.No.SA.5533/ADV and RDSO Spec. No.S6-81. Inspection-Consignee | Numbers | 7.00 | 7,150 | 50,050 |
| 10 | Supply of CLS Post 3.5 mtr. and Ladder 3.5 Mtr. With bases as per RDSO DRG.No.SA.5533/ADV and RDSO Spec. No.S6-81. Inspection-Consignee | Numbers | 4.00 | 6,050 | 24,200 |
| 11 | Supply of offset bracket for colour/position light signal (140 mm/90mm outside Dia as per site requirement) post with U- clamps,nuts, washers complete as per RDSO DRG. No.SA 23080/ADV/ ALT-1. Inspection-Consignee | Numbers | 7.00 | 775 | 5,425 |
| 12 | Casting, concreting and curing of foundation for Main signal and as per DRG.No.SGW/MGS/S1/91 including cost of all materials required for casting and concreting and provision of holding down bolts & nuts. | Numbers | 11.00 | 2,300 | 25,300 |
| 13 | Casting,concreting and curing of foundation for Shunt signal and as per DRG.No.SGW/MGS/S1/91 including cost of all materials required for casting and concreting and provision of holding down bolts & nuts. | Numbers | 5.00 | 1,000 | 5,000 |
| 14 | Installation,erection and wiring of CLS including laying out of tail cable from location box and earthing of CLS as per technical specn.In the tender. 3 Aspect CLS | Numbers | 4.00 | 850 | 3,400 |
| 15 | Installation, erection and wiring of CLS including laying out of tail cable from location box and earthing of CLS as per technical specn.In the tender. 2 Aspect CLS | Numbers | 7.00 | 750 | 5,250 |
| 16 | Installation, Erection and wiring of direction type route indicator. 2 Way | Numbers | 1.00 | 500 | 500 |
| 17 | Installation, Erection and wiring of direction type route indicator. 3 Way | Numbers | 1.00 | 700 | 700 |
| 18 | Installation, Erection laying out of tail cable from Loc. Box and wiring of Shunt Signal as per Technical Specification in the tender.- independent position light shunt signal | Numbers | 5.00 | 200 | 1,000 |
| 19 | Installation, Erection laying out of tail cable from Loc. Box and wiring of Shunt Signal as per Technical Specification in the tender.- On offset bracket | Numbers | 9.00 | 200 | 1,800 |
| 20 | Installation,Erection & laying out of tail cable from loc.box and wiring of Calling On signal on same post below main signal as per technical specification in the tender. | Numbers | 2.00 | 200 | 400 |
| 21 | Supply of PBT ARA terminal as per IRS SPECN No. IRS:S-75-91- 6 way Supply- Inspection RDSO | Numbers | 250.00 | 220 | 55,000 |
| 22 | Supply of Bakelite Strip/Sheet of Size (950 x 75 x 12) mm. For fixing 30Nos. ARA terminals/ Fuse base terminals/Fuse base. Inspection-Consignee | Numbers | 100.00 | 160 | 16,000 |
| 23 | Casting,Concreting and Curing of foundation and erection for full apparatus case (GKP- type)as per DRG No.SGW/MGS/L1/91 includong cost of all materials required for fixing holding down bolts, casting, concreting and fixing of "E" type lock.Note: i)The contractor will provide holding down bolts. ii)Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | Numbers | 70.00 | 1,550 | 1,08,500 |
| 24 | Casting,Concreting and Curing of foundation and erection for Half apparatus case(GKP- type) as per DRG No.SGW/MGS/L1/91 including cost of all materials required for fixing holding down bolts,casting concreting and fixing of E type lock. Note: i)The contractor will provide holding down bolts. ii) Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | Numbers | 5.00 | 1,275 | 6,375 |
| 25 | Casting,Concreting and Curing of foundation and erection for quarter apparatus case(GKP- type) as per DRG No.SGW/MGS/L1/91 including cost of all materials required for fixing holding down bolts,casting concreting and fixing of E type lock. Note: i)The contractor will provide holding down bolts. ii) Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | Numbers | 25.00 | 1,000 | 25,000 |
| 26 | Fixing,wiring of terminal strips,bakelite strip, transformers, relays fuses with base and supply and fixing of shelves for full appratus case. (All materials except transformers,relay,terminal strips, bakelite strip and fuses with base to be spplied by the contractor.). | Job | 70.00 | 1,450 | 1,01,500 |
| 27 | Fixing,wiring of terminal strips, bakelite strip, transformers, relays, fuses with base and supply and fixing of shelves for half apparatus case n. (Materials other than transformers, relay, terminal strips, bakelite strip and fuses with base to be supplied by the contractor.) | Job | 5.00 | 850 | 4,250 |
| 28 | Supply of Bakelite Strip/Sheet of Size (950 x 75 x 12) mm. For fixing 30Nos. ARA terminals/ Fuse base terminals/Fuse base. Inspection-Consignee | Job | 10.00 | 390 | 3,900 |
| 29 | Supply of track lead junction box complete with bush and ARA terminals conforming to IRS:S-75/ 91. Angle iron of Size (1500 x 50 x 50) mm to hold the junction box and for fixing cable entry pipe (40 x 500) mm. Only DRG.No.SA-20101/M. Note: Angle should be 6 MM thick. Inspection- TLJB Consignee, ARA terminal -RDSO | Numbers | 100.00 | 450 | 45,000 |
| 30 | Supply of B-Type choke coil having anneled enamelled copper wire for DC track circuit SPECN.No.IRS-S-65/ 83(Latest) Inspection-RDSO | Numbers | 32.00 | 1,900 | 60,800 |
| 31 | Supply of PBT fuse block with inserts cartridge type, to be mounted inside the location Box/ Relay Rack- Fuses (2A,IRS:S-78/92) Inspection-RDSO | Numbers | 200.00 | 27 | 5,400 |
| 32 | Supply of PBT fuse block with inserts cartridge type, to be mounted inside the location Box/ Relay Rack- Fuse Base (DRG No.SA-23748,IRS:S-75/91) Inspection-RDSO | Numbers | 200.00 | 80 | 16,000 |
| 33 | Supply of 8 SWG soft drawn GI wire bond pieces (1320x4)mm. Resistance upto 19.5 OHM/MT.To IS-280 & IS - 23. Inspection-Consignee | Numbers | 2500.00 | 4 | 10,000 |
| 34 | Supply of channel Pin with single groove 7.2 mm Dia for 4 mm Dia bond wire to DRG.No.S-69/M & IRS Specn.IRS:S-S17. Inspection-Consignee | Numbers | 5000.00 | 1.8 | 9,000 |
| 35 | Installation wiring,testing and commissioning of Single/Double rail DC track circuit as per approved track circuiting plan.The work includes track battery charging and installation,track bonding (double) with 8 SWG soft GI Wire laying of tail cable with track lead junction box,rail connector with Galvanised iron wire track jumpering with supporting arrangement.- Track Circuit (Beyond 200 Mtrs.) | Numbers | 12.00 | 1,100 | 13,200 |
| 36 | Installation wiring,testing and commissioning of Single/Double rail DC track circuit as per approved track circuiting plan.The work includes track battery charging and installation,track bonding (double) with 8 SWG soft GI Wire laying of tail cable with track lead junction box,rail connector with Galvanised iron wire track jumpering with supporting arrangement.- Short length track circuit upto 200 Mts. | Numbers | 9.00 | 1,100 | 9,900 |
| 37 | Installation wiring,testing and commissioning of track circuit involving points & crossing as per Track circuiting plan.Track Battery charging and installation including drilling 9/32'' hole on rails. Installation of bonding,double with 8 SWG soft GI Wire insulation of strecher bars (leading &following) ,guage/crossing tie plates involving cutting & rivetting/welding of angle clit,split stracher bars,fixing of track lead junction boxes.Laying of tail cable | Numbers | 11.00 | 1,100 | 12,100 |
| 38 | Supply of point JB fitted with 18 Nos. 1 way ARA PBT terminal block conforming to IRS - S- 75/91 with 3 Nos. of 40mm Bore. GI pipe 600 mm long as per DRG No.SGW/MGS/PT4/91 fixed on hard wood plank with U-channel (75 x 40 x 1500) mm for fixing. Inspection- Point JB Consignee, ARA terminal -RDSO | Numbers | 12.00 | 1,150 | 13,800 |
| 39 | Supply of complete ground fittings for point machine, including insulated stretcher Bar Switch extension piece etc. and all other accessories required for installation- For IRS point machine Spec IRS-24-90, Turn out [RDSO DRG No- SA- S3261 62 01 Inspection- Consignee | Numbers | 12.00 | 4,300 | 51,600 |
| 40 | Dismantling of existing point fitings and installation of already prepared and matched point fitting sets for point machine of IRS 24/90 type with final testing and commissioning from panel as per technical specification including transportation from railway store.- Turn out (Facing point layout) | Numbers | 12.00 | 3,000 | 36,000 |
| 41 | Charging of lead acid secondary cells of various capacities as per manufactures instruction/railway engineer's instructions acid & distilled water will be suppled by the contractor. - 80 AH (12 Cell) | Set | 8.00 | 1,800 | 14,400 |
| 42 | Supply of CT rack (DRG.N0.S&T/C-19/2001/ER) complete with all fittings including 6 way terminals or wago terminal as per Spec.No.IRS-79/92. Inspection-Consignee | Numbers | 3.00 | 15,000 | 45,000 |
| 43 | Installation of cable termination Rack with scaffolding materials;ladder for supporting outdoor cable;wire guide;complete with other necessary hardwares as per requirements of Rly. & erection materials.(Rate & Staion Wise Qty. to be specified by the tendererer.)- Upto 4 to 5 Line Station | Station | 1.00 | 1,500 | 1,500 |
| 44 | "Preparation of cable route plan,cable core chart ,power supply layout,cable termination chart in relay room and location box.Location wiring plan,cable insulation chart,fuse analysis, equipment disposition plan,track bonding plan, as per railways practice. Note- I) All the above plans for end bunglow also to be submitted.All diagrams/plans to be submitted in polyester film tracing to the railways along with 6 sets of ferro prints of the above. The diagrams/ plans should also be submitted in CD. - upto 4 line station" | Job | 1.00 | 35,000 | 35,000 |
| 45 | Supply of earth electrode.Materials to be procured as per E.Rly Sketch No.SGW/T/3/G/8/89. Inspection-Consignee | Numbers | 100.00 | 500 | 50,000 |
| 46 | Supply of electrical key transmitter for crank handle interlocking arrangement siding control,LC Gate control. Inspection-RDSO | Numbers | 10.00 | 2,500 | 25,000 |
| 47 | Installation of electrical key transmitter on suitable bracket as per inspection of site engineer. ,wiring and testing of electrical key transmitter. | Numbers | 10.00 | 3,880 | 38,800 |
| Schedule total | ₹13,16,550 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
DOCSig-2026-1EIBELA.pdf
ATTACHMENT
ECRJPOregardingprocedureforundertakingearthworkdiggingworktrenchingworkinthevivinityofsignallingtelecomandelectricalcables.pdf
ATTACHMENT
GCC2022correctionslips.pdf
ATTACHMENT
SIPBELA.pdf
ATTACHMENT
GCC_April-2022_2022__GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .