| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹48.2 L+₹3.8 L (8.47%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹49.8 L+₹5.4 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹50.7 L+₹6.3 L (14.1%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹52.1 L+₹7.7 L (17.4%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹44.6 L
EMD Value
₹89,300
Closing Date
19 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo, Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION / ALTERATION WORKS AND PROVISION OF CERTAIN E/M SANCTIONED WORKS AT INS JARAWA AND NSRY (PBR) AND OTHER MINOR WORKS UNDER AGE E/M AT GE HADDO, PORT BLAIR
2023_MES_630302_1
8798/E8
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
As per tender document
9 documents required · 9 mandatory
₹500
GE Haddo
₹89,300
Yes
13 Feb 2024
29 Nov 2023
26 Dec 2023
29 Nov 2023
19 Dec 2023
14 Dec 2023
29 Nov 2023 - 7 Dec 2023
Amount
Supply, install, test & commissioning of Split type air conditioner, 2.0 TR capacity, BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper capacitor, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units, with necessary wall mounting brackets, necessary copper piping for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistanded copper conductor, complete all as specified and as directed. Make: Blue star of model IC524DNU or equivalent of Hitachi/Daikin Note 1 : Extra required all connected pipes/copper cables, as per site, shall be paid separately. 2. The drain out water pipe connection should be connected up to ground level.
Supply and fix Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity 5 KVA complete all as specified and as directed. Make : V-Guard / Premier
M&L submain wiring with 2 runs of 4.0 sqmm mutistranded copper conductor cable (FRLS) PVC insulated 1100 Volts grade and one run of 4.0 sqmm PVC insulated multistranded copper conductor cable (FRLS) earth contuinity conductor Including lugs of suitable size drawn in and including rigid PVC casing & caping/ PVC conduit of suitable size but not less than 25mm width/dia complete all as directed. Make of wire : Polycab/Gloster/Anchor/Havells/Finolex and Make of PVC conduit : Modi/Precision/Supreme/Finolex/Polycab. NOTE : Two runs of 4.0 sqmm and one run of 4.0 sqmm cable alongwith PVC Casing capping/ PVC conduit will be masured as one unit
S &F of Starter switch of capactity 25 Amps, working on 240 Volts AC Supply, suitable for Air Conditioner. Make : (Crabtree : Cat Part No. ACTO 252504/ or equalent in Anchor/Standard.
S &F the following items of Split AC complete all as specified and as directed by Engineer-in-Charge.
1/2" copper pipe
1/4" copper pipe
1/2" Insulation hose
1/4" Insulation hose
5/8" copper pipe
3/8" copper pipe
5/8" Insulation hose
3/8" Insulation hose
2.5 Sqmm 3 core flexible cable
1" CPVC hard drain pipe
Supply and fix Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity 4 KVA complete all as specified and as directed. Make : V-Guard / Premier
Supply, install, test & commissioning of Split type air conditioner, 1.5 TR capacity, BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper condenser, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units, with necessary wall mounting brackets, necessary copper piping for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistanded copper conductor, complete all as specified and as directed. Make: Blue star of model IA718DCU or equivalent of Hitachi/Daikin Note 1 : Extra required all connected pipes/copper cables, as per site, shall be paid separately. 2. The drain out water pipe connection should be connected up to ground level.
Supply, install and commissioning of cast iron centrifugal monoblock pumpset of 10 HP capacity having discharge of minimum of 19.5 LPS and head of 24 meter operating voltage of 415V and 50 Hz AC supply complete all as specified and directed. Make : Kirloskar Brothers Ltd Model KDS-1040+ or equivalent in KSB/CG Note 1 : cost includes the Base MS frame of Pump and motor. 2. Cost includes suitable copper cable/flat copper from DOL starters to Pumps.
S & F DOL starter for capacity 10 HP pumpset complete all as specifed and directed. Make : Havells Model IHHDOLNA*E or equivalent in L&T/BCH/ABB
Supply and lay 3 layer (inner antimicrobial, outer UV Stabilized) ISI Marked, IS-15801, PP-R Pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/ceillings or laying in floors complete including fittings of size 90 mm outer dia.
Supply and lay 3 layer (inner antimicrobial, outer UV Stabilized) ISI Marked, IS-15801, PP-R Pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/ceillings or laying in floors complete including fittings of size 50mm outer dia.
Supply and Fix PPR Gate Valves (Brass insert) of 90mm bore complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix PPR Gate Valves (Brass insert) of 50mm bore complete all as specified and as directed by Engineer-in-Charge.
Supply and fix flanged type Foot valve brass of size 80 mm (3") dia complete all as specified and as directed.
Supply and Fixing of CI Non Return butterfly valve of size 80mm complete all as specified and as directed by Engineer-in-Charge.
M&L providing precast cement concrete solid building blocks type C1 1:3:6 (20 mm graded aggregate) exc 10cm in width setting in CM (1:4) complete, in walls complete all as specified and directed.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290, Gde-E-165 all as specified and as directed
Excavating in post holes (or similar holes) in hard/dense soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed
M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) all as specified.
S&F for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Gde E-165) Quality 'A' complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and getting out in soft/loose soil; for foundation etc, or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
All as per item No. 22 but additional 1.5m or part thereof in depth beyond the first 1.5m all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard dense soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
S&F in repairs 1000 ltr Rotational moulded polye thyelene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia GI medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. (2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
S & F 25mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 455 grams) screwed for iron pipe with necessary GI fittings such as elbows, nipples, etc, including taking down old unserviceable one complete all as specified and as directed. Make : PRAYAG/POLYTUFF or equivalent.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, mass concrete and filling complete for pad of pole etc. complete all as specified and directed.
M&L for plain cement concrete (PCC) type C2 1:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly complete all as specified and directed.
M&L for plain cement concrete (PCC) type B1 1:2:4 using 20mm graded aggregate stone for making copings including use and waste of form work complete etc. all as specified and directed.
Supply, laying, testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x 10 sqmm (laid in terenches,ducts,pole,wall etc.) incl taking down old unsv cable all as specified and directed.
All as per above item No.33 here in before but cable size 4 x 16 sqmm
All as per above item No.33 here in before but cable size 4 x 25 sqmm
All as per above item No.33 here in before but cable size 3.5 x 35 sqmm
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm(OD) x 32mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed. Make:Rex Poly Extrusion Ltd/Tirupati Plastomatics Pvt Ltd.
All as per above item No.37 here in before but of size 50 mm(OD) x 38mm (ID)
Supply & fix FRP pole box 140 x 140 x 95 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6 A MCB SP including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB-1414 or equivalent to Hansel MCB Make- C&S/ Havells/ L & T
Supply & fix FRP pole box 240 x 130 x 95 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6-16 A MCB SP(as required) including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB-2817 or equivalent to Hansel / C&S/ Havells/ L & T
S & F of LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection of cap 180 Watt ,220V 50Hz supply ,pressure Die cast aluminium housing and IP 66 Class I protection to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogen/any type of light fittings all as specified and directed. Make: CG Cat No. LFLN-180-WW/60-M or equivalent model of Philips/ Havells
S & F of LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection of cap 150 Watt ,220V 50Hz supply ,pressure Die cast aluminium housing and IP 66 Class I protection to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogen/any type of light fittings all as specified and directed. Make: CG Cat No. LFLN-150-CDL/60-M or equivalent model of /Philips/Havells
S & F of LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection of cap 70 Watt ,220V 50Hz supply ,pressure Die cast aluminium housing and IP 66 Class I protection to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogen/any type of light fittings all as specified and directed. Make: CG Cat No. TFS-504-70-57-60D-SL-GL-NSG or equivalent model of /Philips/Havells
Supply and fixing in replacement LED Bollard with round top 9/10 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation cable conduits for loop in and out , cable connectors complete incl taking down of any type light fitting complete all as specified and directed Make :- CG Cat no. LBLSN-10-CDL or equivalent in Bajaj / Havells/Philips Note: The cost of PCC foundation will be measured and paid separately under relevant item.
Supply and fixing of outdoor type Decorative Post top for 360° indirect light with IP 65 protection, resistant to impact and corrosion of 240 v, 50 Hz of capacity 40 watt LED suitable for mounting on 60 mm OD pipe on necessasry PCC works complete all as specified and directed. Make:Cat Part No : LPTO-40-CDL-M of CG or equivalent in Philips/C&S
S & F of LED post top lantern of cap 20 watt, IP65 Rated, ideal to light up parks, gardens etc suitable for mounting on 60 mm OD pipe on incl taking down old fittings complete all as specified and directed. Make: CG Cat Part No -LPTH-20-CDL or equivalent in Philips/ C&S/ Havells.
S & F on bracket mounted on pole/ wall etc, LED Street lights of cap 60 watt aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection all as specified and directed. Make: CG CatNo. TRP-409-60-57-SL-GL-NSG or eqvuivalent to Philips /C&S/ Havells
Preparation of old painted surfaces RCC / steel tubular poles of street lights upto 10.0 metre height by scraping with emery paper and making free from rust, dust and any foreign material and applying one coat of synthetic enamel paint of tint as directed including letter writing such as pole number and source point of electric supply with black paint and fluorescent paint in circumference of poles /mast towers of various heights complete all as specified and as directed.
M&L for twin core 4 Sqmm stranded aluminum conductor, PVC sheathed and PVC insulated from light fitting to loop-in/ loop-out box including 15mm dia non-metallic rigid PVC conduit medium grade with conduit accessories fixed with saddles along the pole including taking out old unserviceable conductor complete all as specified and as directed.
M&L for steel tubular swaged poles 410 SP-31 (9.0 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable pole of any type complete all as specified and directed. Make : Kalinga Tubes/The National Tubes CO/India tube & CO
Supply and fixing Cross Arms, bracings, supports, clamps, eye hook etc structural steel sections including pole clamps stay clamps, D clamps nuts, bolts, washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L for 40 mm dia or bore galvanised steel tubing, medium grade, with all fittings and fixed to walls/ poles/ floors or on wall complete as in protection of cables complete all as specified and as directed.
M&L for street light mounting bracket made up of 32 mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of flat iron of size 50 x 6 mm, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing of out door type Street light timer Panel/Distribution Boards with 63A 3 pole/230 Volts contactor and Analog Time Switch, 63A MCB, Manual and Auto Mode Toggle switch cable connectors all as specified and directed. Make: Cat No. TL065AB0 of indoasian or equivalent to CG /Havells
S & F Integrated all-in-one solar street light with lithium iron phosphate battery, solar panel and charger built into the luminaire, pressure die cast aluminium for sturdiness and long life, specially designed pole mounting bracket allows different tilt angles, lateral and pole top mounting. SunStay has highest ever system efficacy of more than 140 lm/W. including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cat Part No. BRP 111 LED 20 / 757 SOLAR M or equivalent to CG/Havells/C&S
A. R. ELECTRICALS
bansal construction
SKV Engineering
CHANDER SEKER ENTERPRISE
Sree Tirumala Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .