| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹47.2 L+₹3.8 L (8.73%)Rejected-Finance ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹47.8 L+₹4.4 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹47.9 L+₹4.4 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹47.9 L+₹4.5 L (10.3%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
22 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) JORHAT
GE (AF) JORHAT PIN-785005
WELCOME MAINT OF OFFRS MD ACCN, MESSES, UNIT GUEST ROOMS AND SINGLE OFFRS LIVING ETC OF AFS UNDER GE (AF) JORHAT
2023_MES_600868_1
8551/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) JORHAT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹90,000
Yes
30 Jun 2023
3 Jun 2023
24 Jun 2023
3 Jun 2023
22 Jun 2023
16 Jun 2023
Amount
M&L for applying one coat of synthetic enamel paint after preparation of old steel surfaces of any descripton exc 10cm width or girth, complete all as specified and as directed.
M&L for applying one coat of synthetic enamel paint after preparation of old wooden surfacess of any description exc 10 cm width or girth, complete all as specified and as directed.
M&L for applying one coat of oil bound distemper after preparation of old surfaces of wall complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over and including a coat of primer and 3mm thick wall care putty after complete removal of existing treatment on wall complete all as specified and as directed.
M&L for applying one coat of white wash on walls after preperation of old wall surfaces complete all as specified and as directed.
M&L for applying one coat of white wash on ceiling after preparation of old ceiling surfaces complete all as specified and as directed.
M&L for preparation of old plastered surface of walls and applying textured exterior paint of required shade as approved by Garrison Engineer (Two or more coats applied @ 3.28 ltr/10 sqm over and including exterior primer applied @ 2.20kg/10 sqm, complete all as specified and as directed.
M&L for applying of two coats of cement base paint over a coat of primer after complete removal of existing finishes, upto any height, by scraping down of old decorative surface of walls with steel wire brushes of smoke spots, moulds, efflorescent salts and cutting/uprooting vegetations growth, including filling of spots with POP complete all as specified and as directed.
S&F as in repairs powder coated aluminuium anodised pipe 20 mm dia as in curtain rod fixed to brackets, complete all as specified and as directed.
S&F as in repairs powder coated aluminium brackets for curtain rods, complete all as specified and as directed.
S&F as in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in window and door as in old door / window, complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in window and door as in new door / window, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
M&L for coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed in CM (1:6), complete all as specified and as directed.
M&L for Coloured Glazed ceramic tiles on vertical surfaces of size, 450X 300X7mm / 350X 250x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cm (1:4), complete all as specified and as directed.
M&L for Coloured Non - skid Ceramic tiles dark shade 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed in CM (1:6), complete all as specified and as directed.
S&F vitrified ceramic coloured tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding in layer in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tiles, complete all as specified and as directed.
S&F as in repairs wash basins, vitreous china (flat back or angle back type) 580x450mm size white, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing and supply of waste pipe, complete all as specified and as directed. Make : Parryware, Cart part No : C0473 or its equivalent model from make as specified in particular specifications.
S&F as in repairs 15 mm dia Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F as in repairs 15mm dia fancy type Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F as in repairs 15mm dia Stop valves fancy type, chromium plated with long shank and cup (concealed type) for iron pipe of 15mm bore of pipe, complete all as specified and as directed.
S&F as in repairs 20mm dia fancy type Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed.
S&F as in repairs 15 mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe, complete all as specified and as directed.
S&F as in repairs 15mm bore fancy type Bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe of 15 mm bore pipe, complete all as specified and as directed.
S&F as in repairs CP two way bib taps 15mm bore screwed for iron pipe and fixed necessary fitting with and including PVC connection, complete all as specified and as directed.
S&F as in repairs PVC waste outlet pipe 32/40mm dia for WHB / kitchen sink including waste coupling complete all as specified and as directed.
S&F as in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified and as directed. Make : Parryware, Cat part No : C0278 or its equivalent model from make as specified in particular specifications.
S&F as in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, as approved, with integral foot rests (excluding flushing cistern and flush pipe), complete all as specified and as directed. Make : Parryware, Cat part No : C0117 or its equivalent model from make as specified in particular specifications.
S&F as in repairs Plastic water closet seat cover (any colour) as approved closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and as directed.
S&F as in repairs PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 but n. exc 4 sqm, complete all as specified and as directed.
Taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each complete all as specified and as directed.
S&F Pressed steel frames 105 x 60 mm made out of 1.25 mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc. complete all as specified and as directed.
S&F Pressed steel frames 125 x 60 mm made out of 1.25 mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc. complete all as specified and as directed.
S&F Pressed steel frames 75 x 50 mm made out of 1.25 mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc. complete all as specified and as directed.
S&F 30mm thick flush shutters, solid core construction with block boards core and plywood face panels, commercial type on both sides with application of decorative laminate of approved colour and pattern, complete all as specified and as directed.
S&F 35mm thick factory made 2nd class hard wood plain , framed , panelled shutter ( 2 panel ) with lock rail and panel of commercial ply or 12 mm veneered particle board with 9 mm B.W.P commercial veneering on both faces.The size of rail and stile as per IS:1003 ( part-I ), kiln seasoned and chemically pressure treated, complete all as specified and as directed.
S&F 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed.
M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing shown in SSR Part-II as approved , complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F as in repairs 125 mm size extruded aluminium alloy handles, fabricated type anodised including the screws , complete all as specified and as directed.
S&F 125 mm size extruded aluminium alloy handles, fabricated type anodised, including the screws complete all as specified and as directed.
S&F as in repairs 150mm long aluminium anodised, barrel tower bolts of extruded section including the screws complete all as specified and as directed.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and as directed.
S&F as in repairs 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F 100mm long Hasp and staple, aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F as in repairs 100mm long Hasp and staple, aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-0 (using 12.50mm graded stone aggregate) for filling in pressed steel door frames or hold fast / lugs fixing to wall complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces over exc 10cm girth or width complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of pink primer after preparation of new wooden surfaces over 10cm width or girth, complete all as specified and as directed.
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc, complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:6) finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface of wall with cement mortar (1:4) finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement, complete all as specified and as directed.
M&L for applying two coats of cement base paint over a coat of alkali resistance primer after preparation of new plastered surfaces of wall, complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over and including a coat of primer to newly plastered surface after preparation of new plastered surfaces of wall, complete all as specified and as directed.
M&L for applying three coats of white wash on wall after preparation of newly plastered surface complete all as specified and as directed.
M&L for applying three coats of white wash on ceiling after preparation of newly plastered surface complete all as specified and as directed.
S&F as in repairs bathroom cabinet mirror (of approved pattern) of size 450mmx 350mm regular size with mirror and PVC shelves, complete all as specified and as directed.
S&F as in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
S&F as in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
S&F as in repairs kitchen plate rack made of stainless steel 1mm thick including fixing, overall size 915mm x 915mm x 255 mm, complete all as specified and directed.
S&F as in repairs health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
Demolition stone slabs and tiles of any description or thickness in floors aprons laid and bedded and jointed in cement mortar, complete all as specified and as directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed or bedding layer 15 mm thick in cement mortar (1:6) complete all as specified and as directed.
Disconnecting existing tanks of (exc 500 & n exc 1000 ltrs in capacity), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and as directed.
Disconnecting existing tanks of (exc 250 & n exc 500 ltrs in capacity), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and as directed.
M&L for cleaning and removing all scale and dirt, etc., from overhead PVC/RCC tank of capacity exc 500 ltr but not exc. 1000 ltr each and from mouths of circulating pipes etc., complete all as per specified and as directed.
M&L for cleaning and removing all scale and dirt, etc., from overhead PVC/RCC tank of capacity exc 250 ltr but not exc. 500 ltr each and from mouths of circulating pipes etc., complete all as per specified and as directed.
S&F Rotational moulded polyethylene (HDPE) water storage tank 500 litre capacity (cylindrical vertical with closed top), black in colour, three layered construction, hoisted and fixed in position all specified in MES schedule Part-I, including dismantling of water storage tank with float valve of any description complete all as specified and as approved.
S&F Rotational moulded polyethylene (HDPE) water storage tank 1000 litre capacity (cylindrical vertical with closed top), black in colour, three layered construction, hoisted and fixed in position all specified in MES schedule Part-I, including dismantling of water storage tank with float valve of any description complete all as specified and as approved.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n. exc. 1.5 sqm, complete all as specified and as directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, steel peg stay with glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F Steel windows with side hung shutters with box type hinges shutters with steel handle and steel peg stay without glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165, complete all as specified and as directed.
Hacking out old broken glass (any thickness, size , qulaity or description) as in metal frame including punching or drilling out old glazing pins/spring clips, complete all as specified and as directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane, complete all as specified and as directed.
S&F 4mm thick sheet glass, figured glass, pin headed type, glazing with oil putty in squares n exc 0.5 sqm each pane, complete all as specified and as directed.
S&F as in repairs 100 mm mild steel butt hinges medium weight, cold rolled , complete all as specified and as directed.
S&F 100 mm stainless steel butt hinges medium weight, cold rolled, complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store, complete all as specified and directed.
S&F 15 mm bore GI tubing "medium grade" galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors, complete all as specified and as directed.
Re-fixing only GI tubing of 15 mm bore, any grade, to walls and ceiling or laying in floors, complete all as specified and as directed.
S & F 20 mm bore GI tubing "medium grade", galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors, complete all as specified and as directed.
Re-fixing only GI tubing of 20 mm bore, any grade, to walls and ceiling or laying in floors, complete all as specified and as directed.
S&F as in repairs 12 mm thick Pre-laminated particle board, exterior grade, prelaminated both side with decorative choice laminations etc, complete all as specified and as directed.
S&F as in repairs 40 mm width continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and as directed.
S&F as in repairs 20mm dia tubular towel rail, D type 60cm long between flanges brass chromium plated, complete all as specified and directed.
S&F as in repairs 125mm size chromium plated shower roses with or without swivel joints, including fixing to steel pipe or union, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as per specified and as directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in floors and finishing without using extra cement complete all as specified and as directed.
S&F as in repairs 100mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as direcetd.
S&F as in repairs grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
Demolition and breaking up drain pipes (PVC or AC pipe) set in cement mortar for 100mm bore pipe complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as direcetd.
S&F 110mm bore PVC (SWR) bends any radius provided with access door complete all as specified and as directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and as direcetd
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F as in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S&F as in repairs soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
Demolition of reinforced cement concrete for roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as per specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) and making flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismantling fillets, rails, posts, rafters, purlins, etc. under 40sq.cm in section for unframed work complete all as specified and as directed.
Dismantling timber scantling, 40sq.cm and over in section, in any position, in unframed work, complete all as specified and as directed.
M&L for 2nd class hard wood timber scantlings clean sawn complete all as specified and as directed.
M&L for 2nd class hard wood plain fillets square rectangular or triangular in section clean sawn cross sectional area exc 6.0sqcm and not exc 13sqcm screwed with nails complete all as specified and as directed.
M&L for 2nd class Hard Wood plain fillets square rectangular or triangular in sec clean sawn sectional area exc 13.0sqcm and not exc 25sqcm screwed with nails complete all as specified and as directed.
S&F 2nd class hard wood plain ,solid, straight, chowkhat and framed, wrought, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed
Refixing shutters in same opening including taking down, easing and adjusting of any description of area exc 1.00sqm but n. exc 2.00sqm each. complete all as specified and as directed.
Taking down carefully point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket etc and making good disturbed surface of wall/floor etc complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm FRLS grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC cassing and capping (not less than 20 mm wide) complete with all acessories including PVC board/ box of suitable size for mounting of switches, sockets, regulators etc including 1.5 sq mm stranded copper conductor cable FRLS grade PVC insulated and unsheathed as earth continuity conductor for one light point controlled by one way switch complete by maintaining the colour code complete all as specified and as directed.
All as per Ser item No. 116 here-in-before but for One ceiling / exhaust fan point controlled by one one way switch.
All as per Ser item No 116 here-in-before but for 5 amps socket point on independent board.
All as per Ser item No 116 here-in-before but 5 amps socket point on same board controlled by another switch.
All as per Ser item No 116 here-in-before but for One bell point controlled by one bell push.
All as per Ser item No 116 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board, using 2.5 sqmm earth continuity wire.
All as per sl. item No. 116 here-in-before but with 4 sqmm cable for 20/25 amps power unit on independent board, using 4 sqmm earth continuity wire.
S&F as in repairs ceiling rose surface backelite three terminals, PVC / polycarbonate, insulated body complete all as specified and as directed.
S&F as in repairs switch piano flush type, 6 Amps 240 volts single pole one way complete all as specified and as directed.
S&F as in repairs socket outlet, 5 pin 6 Amps, flush type complete all as specified and as directed.
S&F as in repairs socket outlet 15/16 Amps, 6 in 1, flush type complete all as specified and as directed.
S&F as in repairs switch piano flush type,15/16 Amps 240 volts single pole one way complete all as specified and as directed.
S&F as in repairs fan regulator electronic type, rotary step, socket type 240 volts complete all as specified and as directed.
S&F as in repairs Switch Bell push flush type, 5 Amps, 240 volts complete all as specified and as directed.
S&F as in repairs Switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush, universal type complete all as specified and as directed.
S&F as in repairs Switch socket combination 2 in 1, 5 Amps flush type with box complete all as specified and as directed.
M&L for One LED tube light / LED lamp / Bldg security light point controlled by one way switch with PVC cables 1.5 sq. mm size insulated unsheathed FRLS cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including non-metallic rigid PVC conduit "medium grade" and conduit accessories ISI marked concealed in wall / ceiling/ fixed to roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor, fabricated steel sunken terminal box duly painted made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and directed.
All as per Ser item No 132 here-in-before but for One ceiling / exhaust fan point controlled by one one way switch.
All as per Ser item No 132 here-in-before but for 5 amps socket point on independent board.
All as per Ser item No 132 here-in-before but for One bell point controlled by one bell push.
All as per Ser item No 132 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board with 2.5 Sqmm earth continuty wire.
All as per Ser item No 132 here-in-before but with 4 sqmm cable for 20/25 amps Power Unit on independent board with 4 Sqmm earth continuty wire.
S&F as in repairs switch piano, modular type, 6 Amps 240 volts single pole one way complete all as specified and as directed.
S&F as in repairs socket outlet, 5 pin 6 Amps, modular type, complete all as specified and as directed.
S&F as in repairs socket outlet 6/16 Amps, 6 in 1, modular type, complete all as specified and as directed.
S&F as in repairs switch piano modular type, 15/16 Amps 240 volts single pole one way complete all as specified and as directed.
S&F Modular plates with frame (white colour) 2 module complete all as specified and as directed.
S&F Modular plates with frame (white colour) 4 module complete all as specified and as directed.
S&F Modular plates with frame (white colour) 6 module complete all as specified and as directed.
S&F Modular plates with frame (white colour) 8 module complete all as specified and as directed.
S&F Switch belll push, modular type, single pole, complete all as specified and as directed.
S&F Stepped type electronic fan regulator, modular type, 2 modular, 240 Volt, complete all as specified and as directed.
S&F as in repairs 20 watt intregated LED tube light fitting 4 ft, suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified and as directed. Make:- Crompton, Cat No.CCS-102-20-65-SL-DP-NWH or its equivalent model from make as specified in particular specifications.
S&F as in repair 10 watt intregated LED tube light fitting 2 ft, suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified and directed. Make:- Crompton, Cat No.CCS-102-10-65-SL-DP-NWH or its equivalent model from make as specified in particular specifications.
M&L for Submain wiring with two runs of single core 6 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed. NOTE:- (i) Extra length of cables / wire required for connection to MCBs / DBs shall not be measured under this items. (ii) Cuttings / chasing of wall etc and making good the disturbed surface shall be measured and paid separately. (iii) Three runs of cable 6 Sqmm shall be measured as one RM of sub main wiring.
All as per Ser Item No- 150 here-in-before but two runs of single core 4 Sqmm for phase & neutral and 01 run of single core 4 Sqmm for earth wire complete all as specified and directed. (i) Three runs of cable 4 Sqmm shall be measured as one RM of sub main wiring.
Taking down MCB DB / Main switch of any size and making good disturbed surface of wall / floor complete all as specified and as directed.
S&F SP&N DBs, double door, 240 volt, 12 way complete all as specified and as directed. MAKE:- Legrand, Cat part No. 5076 12 or its equivalent model from make as specified in particular specifications.
S&F SP&N DBs, double door, 240 volt, 8 way complete all as specified and as directed. MAKE:- Legrand Cat part No. 5076 11 or equivalent model from make as specified in particular specifications.
S&F SP&N DBs, double door, 240 volt, 4 way complete all as specified and as directed. MAKE:- Legrand, Cat part No. 5076 10 or its equivalent model from make as specified in particular specifications.
S&F TP&N DBs, double door, 240 volt, 4 way complete all as specified and directed. MAKE:- Legrand, Cat part No. 5076 70 or its equivalent model from make as specified in particular specifications.
S&F VTPN DB , 415 volt, 4 way, 200 Amp Bus Bar with metal door having facility for MCCB incomming up to 250 Amps and MCB out going complete all as specified and directed. Make: Legrand, Cat No. 5077 45 or its equivalent model from make as specified in particular specifications.
S&F as in repairs MCCB 160 Amps current carrying capacity 415 volts, 25 KA, 4 pole thermal magnetic type along with spreader terminals complete all as specified and as directed. Make: L&T, Cat No. CM98065OOMO or its equivalent model from make as specified in particular specifications.
S&F as in repairs 415 volts, 10 KA, 'C' curve Miniature circuit breaker (MCB) of TPN 40 to 100 Amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed. MAKE:- Legrand, Cat part No. 4086 83 or its equivalent model from make as specified in particular specifications.
S&F as in repairs MCB single pole, 240 volts, 6 - 32 Amps, 10 KA, C Curve complete all as specified and as directed.
S&F as in repairs MCB single pole, 240 volts, 40 Amps, 10 KA, C Curve complete all as specified and as directed.
S&F as in repairs MCB single pole & neutral 240 volts 32 Amps, C Curve in the MCB, DB with connection including testing complete all as specified and as directed.
S&F as in repairs MCB single pole & neutral 240 volts 40 to 63 Amps, C Curve in the MCB, DB with connection including testing complete all as specified and as directed.
S&F as in repairs surface mounting LED 2ft x2ft luminaire of capacity 36W with white powder coated CRCA housing with LEDs and full window acrylic diffuser etc.complete with all acessories internally prewired suitable for sigle phase 230volts 50Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified. Make -Crompton, Cat No.LCTLSNE-36-FO-CDL or its equivalent model from make as specified in Particular specifications.
S&F as in repairs Building security light 30 watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP-65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver, complete all as specified and directed. Make:Crompton, Cat No.LSTS-30-CDL-M or its equivalent model from make as specified in Particular specifications.
S&F 1200 mm sweep ceiling fan, double ball bearing , AC motar, 230 volt, 50 Hz, 3 blade with up to 30 cm down rod, 02 Nos of canopies, power input 65 watt, 380 RPM, copper winding, air delivery minimum 200 cm, including connecting up of cable with flexible pipe from ceiling rose or connector to fan after taking down old unserviceable ceiling fan in any position complete all as specified and as directed .
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
S&F as in replacement of defective PVC casing and capping including joints, junction box, joint clip, I corner, T cap etc complete all as specified and as directed. Note :- Rate are inclusive of PVC casing and capping and all its accessories.
S&F as in repairs Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed.
S&F 12W LED bulb B-22 type, CDL / WW complete all as specified and as directed.
S&F as in repairs round / square recess mounted15W LED edge lite slim downlight with dia-cast aluminium housing finished in preminium white powder coating efficacy 100 lm/w complete with all acessories internally prewired suitable for sigle phase 230volts 50Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified and as directed.
S&F as in repairs polycarbonate unbreakable white globe doom of 8 inch dia in existing garden light pole complete all as specified and as directed.
M&L for as in repairs PVC insulated two core 2.5 sqmm multistrand aluminium conductor for connection of garden / bldg security light complete all as specified and as directed.
M&L for 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and as directed of following size:- Note :- Switch, socket, fan regulator etc shall be measured separately in the relevant item.
(a) 4 inch X 4 inch
(b) 7 inch X 4 inch
(c) 8 inch X 10 inch
S&F round corrugated flexible pipe of 16mm dia complete all as specified and as directed.
S&F decorative wall light, wall mounted, in durable plastic body with suitable for LED bulb complete all as specified and directed.
S&F MCB protected POWER UNIT with one 25 amps socket, (incl 3 Pin Plug Top) including MCB DP and starter 25 Amps rating with six module plate and flush metal GI box and electrically connecting up fixed in repair complete all as specified and as directed. Make : Havells cat No- DHDUCDP0253016-25 (25 Amps) or its equivalent model fom make as specified in particular specifications.
S&F as in repairs capacitor 2.5 MFD 440 Volts AC 50Hz, suitable for ceiling fan of any sweep and Make, complete all as specified and as directed.
S&F as in repairs capacitor 3.15 MFD 440 Volts AC 50Hz, suitable for ceiling fan of any sweep and Make, complete all as specified and as directed. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S DHAR AND DHAR
AJOY DUTTA CHOWDHURY AND CO
M/S RK SAHA AND CO
NIHAR ENTERPRISE
M/S AK SINGH
M/S SANTOSHI TRADERS
M/S BARUAH ELECTRICALS
Bidder Name
NIHAR ENTERPRISE
M/S RK SAHA AND CO
AJOY DUTTA CHOWDHURY AND CO
M/S DHAR AND DHAR
M/S PAUL CONSTRUCTION
M/S SANTOSHI TRADERS
M/S AK SINGH
M/S BARUAH ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .