Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | L2₹12.2 L+₹67,832.50 (5.87%)Rejected-Finance 21 KISHORE BHAWAN MALVIYA NAGAR AIR FORCE JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹12.3 L+₹74,557.50 (6.45%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹12.8 L+₹1.3 L (11.0%)Rejected-Finance BINNAGURI HATKHOLA PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹14.6 L+₹3.0 L (26.3%)Rejected-Finance ROOM NO 281 GANESH MARUTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
4 Jun 2024, 6:00 pmClosed
GE AF BIHTA
AIR FORCE STATION BIHTA 801103
REPAIR/MAINTENANCE AND REPLACEMENT OF OLD UNSV GI/CI PIPE LINES OF VARIOUS LOCATIONS INCLUDING CONTROL VALVES AND VALVE PITS ETC AT ZONE A AND ZONE B AT AF STN BIHTA
2024_MES_653139_1
8406/BHT/E8
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
BIHTA
Class E and above and category a(ii)
6 documents required · 6 mandatory
₹500
GE AF BIHTA
₹32,000
Yes
23 Sept 2024
9 May 2024
11 Jun 2024
9 May 2024
4 Jun 2024
23 May 2024
10 May 2024 - 16 May 2024
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable/ Pipe lines / erection of poles, stays etc. complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing of excavated material n.exc 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc.
M&L for PCC 1:3:6 type C-2 using 20mm graded aggregate, mechanically crushed stone for mass filling in water supply pits and foundation all as specified.
S & F in replacement of old unsv MCCB triple pole 125 Amps with thermal magnetic trip and earth link connectors in LT control panel board where directed and making necessary electrical connections complete all as directed.
S & F in replacement of old unsv Power contactors 4 pole 40-63 Amps with 2NO+2NC where directed and making necessary electrical connections complete all as specified and as directed.
M & L for cleaning of overhead reservoir internal portion from base to top including scraping of mud silt from base and walls, washing complete internal surfaces by using bleaching powder, antibacterial sodium hypochlorite solution, removing the silt/mud water out side the tank and de-silting from connecting pipes and applying internally one coat of lime wash to RCC walls, base of tanks of 50000 gallons upto 30 mtrs staging complete & writing details of cleaning in prescribed format complete all as specified and as directed. Therefore following procedure shall be followed during cleaning of OHT. (a) Cleaning of water tanks with high pressure water jet with pressure not exeeding 28Kg/Sqcm and remove all masses algae and dirt. (b) Removal of dirty water alongwith sludge using sludge machines and disposal of the same to a safe distance. (c) Scrubbing of floors using industrial vacuum cleaner. (d) Applying of anti bacterial sterilization to walls floors and roofs of tanks. (e) Testing of water shall be carried out after cleaning of tank and a certificate to this effect shall be submitted while claiming payment . (f) Tank capacity and date of cleaning shall be marked on tanks neatly with oil paint all as directed by the EIC. Location : Pump House No 2 (Near MES Colony) Note : Cleaning of reservoirs shall be carried out the gap in between 4-5 months or as and when required/demanded by the Engr-in-Charge.
Description all as per item Ser No. 8 above but for 75000 gallons. Location : Pump House No 3
Description all as per item Ser No. 8 above but for 5000 gallons. Location : Ops
S & F in replacement of old unsv fully automatic star delta starter assembly (ASD) - HGS Series having Range: 26 KW, conforms to IS/IEC 60947-4-1, provided with Protection Degree IP 54, having extended wide band coil, FRLS internal wiring, Class H insulation air break starter type, having contactor size 32, overload relay range 28 A to 40 A and complete suitable for 30/35HP sub mersible pumping set including fixing in same position and making necessary electrical connection to LT control panel of pump house and testing upto the satisfaction of Engr-in-Charge complete all as specified and as directed. Make: Havells Cat Part No IHHASDXB or equivalent in Schneider/ABB etc.
M & L for rewinding of burnt submersible pumping set of capacity 25/30HP capacity with the existing gauge of copper winding wire with same insulation including replacement of bearings complete all as per standard norms and testing upto the satisfaction of Engr in-charge.
Taking out old unserviceable DI/CI pipe with all fittings from trenches of following sizes all as directed :- (Note : Excavation & earth work will be measured & paid seperately under respective item).
150 mm dia bore.
100 mm dia bore.
80 mm dia bore.
Supply only DI pipe of 150 mm bore ISI marked, spigot and socketed type, Class K-7 centrifugally cast suitable for rubber tyton joints laid in trenches complete all as specified and as directed by Engineer-in-charge. (Earth work for excess width of taking down, route change of pipe & joints shall be measured and paid separately).
Description all as per ser item No.14 here-in-before but for 100 mm bore.
Description all as per ser item No.14 here-in-before but for 80 mm bore.
Laying only DI/CI pipe new or old position in trenches where directed and testing complete all as specified :- (Note : Excavation & earth work will be measured & paid seperately under respective item).
150 mm dia bore.
100 mm dia bore.
80 mm dia bore.
M&L Bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm bore for spigot socketed pipes.
M & L Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150mm bore for flanged pipes.
Taking out old unserviceable GI tubing with all fittings from trenches, walls, floors etc. of following sizes all as directed :- (Note : Excavation & earth work will be measured & paid seperately under respective item ).
80 mm dia bore.
50 mm dia bore.
25 mm dia bore.
20 mm dia bore.
M & L for GI pipe medium grade with all fittings laid in trenches 80mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge.
Description all as per ser item No 21 here-in-before but of size 50 mm dia.
Description all as per ser item No 21 here-in-before but of size 25 mm dia.
Description all as per ser item No 21 here-in-before but of size 20 mm dia.
S & F Gun metal gate valve 50 mm ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
Description all as per ser item No 25 here-in-before but of 40 mm bore.
Description all as per ser item No 25 here-in-before but of 25 mm bore .
Description all as per ser item No 25 here-in-before but of 20 mm bore.
M&L for lead wool joints for spigot and socket pipes and fittings with all jointing materials like spun yarn etc all as specified and directed for the following sizes:-
150 mm bore.
100 mm bore.
80 mm bore.
M&L for run lead joints for spigot and socket pipes and fittings with all jointing materials like spun yarn etc all as specified and directed for the following sizes:-
150 mm bore.
100 mm bore.
80 mm bore.
Material & Labour for brick masonry valve pit internal size 1200mm x 1200mm x 1200mm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC plate form with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center) complete all as specified and as directed by Engineer-in-Charge.
Description all as per ser item No 31 here-in-before but of size 1000mm x 1000mm x 1000 -ditto-
Description all as per ser item No 31 here-in-before but of size 600mm x 600mm x 600m -ditto-
S & F in replacement of unsv/damaged 15mm bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Labour only for disconnecting unsv/defective electric connections and lifting the unserviceable pumping sets 25/30/35HP from the bore well and lowering of submersible pump sets after repairing including M&L for replacement of gaskets, suitable size of steel nuts, bolts and washers of suitable size complete all as directed by Engineer-in charge including transportation to workshop and back to site complete.
S&F 3 core flat copper conductor, multistranded cable for submersible pump set of 1100 volt grade 10 sqmm size MAKE: HAVELLS Cat Pat No WHPNDSKG3010 or equivelent make and model of FINOLEX/PLAZA /Paragon.
Supply & Fixing in replacement of old unsv CI Sluice valve with flanged ends of size 150 mm dia complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber / fiber board gasket, nuts, washer etc. including taking down old/unservicable Sluice valve complete all as specified and as directed by Engineer-in Charge. Make: BVI/ Kirloskar/ Kishor/Kartar.
Description all as per item Ser No 37 but for 100mm dia.
Description all as per item Ser No 37 but for 80mm dia.
Cutting of existing cast iron pipe and reducing the length upto required level for insertion of new tee, branch connection or any other means etc. upto 150mm dia complete all as specified and as directed by Engineer -in-charge.
M&L for Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass, shrubs and bushes etc. in the sub station yard and making the surface/floor clean all as directed and specified.
Material and Labour for dismantling the 150mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland bush, nuts, gasket, bonnet and disc or as required at site complete all as specified and as directed.
Material and Labour for dismantling the 100 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland bush, nuts, gasket ,bonnet and disc or as required at site complete all as specified and as directed.
Material and Labour for dismantling the 80 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland bush, nuts, gasket, bonnet and disc or as required at site complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 80mm dia size Complete including replacing / tightening the existing bolts and nuts etc. complete all as directed by Engr-in-Charge.
Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size Complete including replacing / tightening the existing bolts and nuts etc. complete all as directed by Engr-in-Charge.
Material and Labour for gland packing in leaking Sluice Valves of 150 mm dia size Complete including replacing / tightening the existing bolts and nuts etc. complete all as directed by Engr-in-Charge.
M&L for collection of water samples from various bore wells located at different area of air force station Bihta in white colour PVC containers of capacity not less than 5.0 Ltr, hygenically dry, neat & clean duly sealed and transporting the same to laboratory for followings tests of drinking water for portability charaterstics/parameter as per IS 10500-2012 from Government approved/certified laboratory seperately for each borewell and submit the test results/reports of water samples (bore well wise) to Engineer in charge for maintain the record at bore wells/sub divn level and Engineer in charge will submit the same as and when asked by GE complete all as specified and directed.
(a) Colour (Ref Std & test method as per IS:3025(P-4)-1983/2017 (b) Odour (Ref Std & test method as per IS:3025(P-5)-1983/2017 (c) Turbidity (Ref Std & test method as per IS:3025(P-10)-1984/2002 (d) Temperature (Ref Std & test method as per IS:3025(P-44)-1993/2009 (e) Taste (Ref Std & test method as per IS:3025(P-44)-1993/2009 (f) TDS(Total dissolved Solids) (Ref Std & test method as per IS:3025(P-9)-1984/2017 (g) pH (Ref Std & test method as per IS:3025(P-11)-1983/2017 (h) Iron as Fe (Ref Std & test method as per IS:3025(P-40)-1991/2014 (j) Nitrate as N (Ref Std & test method as per IS:3025(P-34)-1988/2003. (k) Arsenic as As (Ref Std & test method as per 3114:APHA 23rd End-2017(l) Chloride as Cl (Ref Std & test method as per IS:3025(P-32)-1988/2014 (m) Sulphate as SO4 (Ref Std & test method as per IS:3025(P-24)-1988/2014 (n) Alkalinity as CaCO3 (Ref Std & test method as per IS:3025(P-23)-1986/2014 (o) Hardness (Ref Std & test method as per IS:3025(P-21)-2009/2014 (p) Calcium as Ca (Ref Std & test method as per IS:3025(P-40)-1991/2014 (q) Magnesium as Mg (Ref Std & test method as per IS:3025(P-46)-1991/2014 (r) Conductivity (Ref Std & test method as per IS:3025(P-45)-1993/2013 (s) Fluoride as F (Ref Std & test method as per IS:3025(P-60)-2001/2013 (t) Coliform Count (Ref Std & test method as per IS:1622:1981 (RA 2009) (u) Residual Chlorine (Ref Std & test method as per IS:3025(P-26)-2007/2014 (v) E-Coli (Ref Std & test method as per IS:1622:1981 (RA 2009)
GANPATI ENTERPRISES
Bikarma Enterprise
M/s AHMED ENGINEERING
ARTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .