| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹18.5 L+₹76,016.50 (4.28%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹19.1 L+₹1.3 L (7.54%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹20.0 L+₹2.3 L (12.7%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹20.9 L+₹3.2 L (17.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Aug 2023, 6:00 pmClosed
Lt Col Aditya Gorhe
GE Utility Bathinda Mil stn
REPAIR/REPLACEMENT OF LT PANEL AND MISC ELECTRICAL WORKS AT DIFFERENT WATER SUPPLY INSTALLATION UNDER GE UTILITY BATHINDA
2023_MES_609255_1
8722/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
class E cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹50,000
Yes
13 Sept 2023
15 Jul 2023
17 Aug 2023
15 Jul 2023
15 Aug 2023
31 Jul 2023
Amount
Dismantling/Taking down to existing unserviceable panel board of any size by disconnecting the existing cable connection, earthing etc complete all as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying of cables or pipes (where provided) and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed .
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of size of any size from pole / wall / cable duct under ground trench etc for re-use or removal from site of work complete all as directed. Note: Excavation and earth work shall be measured and paid separately under respective item)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed.
All as per serial item No 05 above but sectional area 16 Sq mm 4 core.
All as per serial item No 05 above but sectional area 50 Sq mm 3.5 core.
All as per serial item No 05 above but sectional area 70 Sq mm 3.5 core.
Laying only old serviceable under ground PVC/XLPE LT cable of any grade , any size laid in trenches / fixed to wall / pole / roof / laid in floor including necessary connections and thimbling complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and as directed.
M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm complete all as directed.
Supply and laying well burnt sub class B breicks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
Supply and laying or fixing GI tubing light grade 50 mm dia for cable protection including fitting with flat iron clamps, size of flat iron 25mm x 4mm, nuts, bolts & washers fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench complete all as specified and directed.
Supply and erecting Steel tubular poles type 410 SP-31 (9.00 mtr long) with cast iron base plate, finial, taper plug, bolts nuts & screws including painted with bituminous paint internal surface of steel tubular pole through out and external surface up to planting depth and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles after dismantling the old existing unserviceable pole complete all as directed. Note:- PCC and earth work shall be measured and paid for separately under respective item..
M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in foundation of electric poles/struts etc including necessary formwork complete all as specified and directed. Note: Volume of poles/struts embedded in concrete shall be deducted during calculation the quantity of PCC for foundation )
M&L for PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate as in coping of electric poles/struts etc including necessary formwork complete all as specified and directed. Note: Volume of poles/struts embedded in concrete shall be deducted during calculation the quantity of PCC for coping.)
S&F junction box ,size not less than 200mm x 160mm x 98mm, insulated type , made out with Polycarbonate with glass fiber reinforced with MCB SP 'C' curve 6 Amp complete all as directed. Make: Hensel, Cat Part No. K 9350 / Siemens / GE Power. Note :- (i). Manufacturer should submit routine test certificate for CJB/PJB (ii).The Polycarbonate Junction Box shall be environment friendly, recyclabe, UV resistant, halogen & silicon free, anti acid & anti corrosive. (iii). The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. (iv).The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. (v).The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60988 - 2 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. (vi). The Junction Box color according to RAL 9011. (vii).The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08.
Supply and fixing Street light bracket made out of 40 mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangement for LED fitting duly painted with two coats of synthetic aluminium paint over a coat of red oxide primer including MS clamps and back plates fabricated from steel section including nuts, bolts, washer etc complete all as directed.
S&F wall mounted LED Batten T-8 Retro LED 18/20 watt, appx 4 feet long, pre wired including LED tube light, not less than 6000K, integrated electronic driver and all other accessories, electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector after taking down existing old unserviceable light fitting complete all as specified and as directed.
S&F New gerneration energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 luminaire with high power LED of 25 watt security light fitting with toughened glass and lamp including GI bracket (01 No) MS clamps (02 Nos) suitable for security light fitting fixing to wall / column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing after taking down existing old unserviceable light fitting complete all as specified and as directed.
S&F New gerneration energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 luminaire with high power LED of 60 watt security light fitting with toughened glass and lamp including GI bracket (01 No) MS clamps (02 Nos) suitable for security light fitting fixing to wall / column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing after taking down existing old unserviceable light fitting complete all as specified and as directed.
S&F post top lantern decorative oriental design landscape luminaire suitable for and including 1X40 watt LED lamp with opel diffuser after taking down existing old unserviceable light fitting complete all as specified and as directed.
S&F energy efficient LED Flood light fitting of 150 Watt, 6000K epoxy powder coated pressure die cast aluminium housing to act as heat shrink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting after taking down existing old unserviceable light fitting complete all as specified and as directed.
S&F energy efficient LED Flood light fitting of 60 Watt, 6000K epoxy powder coated pressure die cast aluminium housing to act as heat shrink for efficient dissipation of heat and toughened glass with IP 65 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting after taking down existing old unserviceable light fitting complete all as specified and as directed.
S&F fully automatic star delta starter with sheet metal enclosure 415 volts, 3 phase, 50 Hz with single phase protection feature and timer with relay range 45 to 75 Amp and contractors suitable for 60 HP electric motor after disconnecting/removing the old unserviceable starter from existing location and making electric connections complete all as directed.
S&F fully automatic star delta starter with sheet metal enclosure 415 volts, 3 phase, 50 Hz with single phase protection feature and timer with relay range 20 to 33 Amp and contractors suitable for 40 HP electric motor after disconnecting/removing the old unserviceable starter from existing location and making electric connections complete all as directed.
S&F DOL starter with sheet metal enclosure 415 volts, 3 phase, 50 Hz with relay range 9 to 15 Amp suitable for 10 HP electric motor complete including disconnecting/removing the defective starter from existing location and making electric connections complete all as directed.
S&F in repair power contactor 415 volt, 50 HZ, 3 pole, type ML-6 complete all as specified and as directed by Engineer-in-charge.
S&F in repair power contactor 415 volt, 50 cycles, 3 pole, type ML-4 complete all as specified and as directed by Engineer-in-charge.
S&F in repair power contactor 415 volt, 50 HZ, 3 pole, type ML-3 complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 80 complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 70 complete all as specified and as directed by Engineer-in-charge.
S&F in repair bimetal over load relay single phase protection directly mounted 28 to 42 Amps, range ML2/ML3 complete all as specified and as directed by Engineer-in-charge.
S&F in repair bimetal over load relay single phase protection directly mounted 66 to 110 Amps, range MN5 complete all as specified and as directed by Engineer-in-charge.
S&F in repair bimetal over load relay single phase protection directly mounted 45 to 75 Amps, range MN5 complete all as directed.
Supply and fixing in repair electronic timer (time delay relay) of range 12-120 sec, input voltage 220 to 240 volts AC complete all as specified and as directed by Engineer-in-charge .Make :–L&T / ABB/BCH/Simens
Supply and fixing in repair single phase preventor, type VSP-2 suitable for 3 phase star delta starter of any capacity complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair MCCB, 250 Amp, 4 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair MCCB, 250 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair MCCB, 125 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair MCCB, 100 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair MCCB, 63 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement change over switch 200 Amps, 415 Volts, FB 50 HZ manually operated complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement change over switch 400 Amps, 415 Volts, FB 50 HZ manually operated complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement change over switch 630 Amps, 415 Volts, FB 50 HZ manually operated complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement change over switch 800 Amps, 415 Volts, FB 50 HZ manually operated complete all as specified and as directed by Engineer-in-charge.
Preparation of the old painted surfaces of feeder piller boxes/panels/boards of any size any description and in any position including removal of faded & deteriorated paint eaither by hand scrapping or by blow lamps, applying necessary filler coat and scrspping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine on old prepared surfaces complete all as spcified and as directed by Engineer- in Charge.
Supply and fixing MS sheet water level indicator board size 30 cm x 450 cm alongwith suitable support MS angle, rope and float valve as specified and directed by Engineer-in-Charge. Note :- (i) Level indicator board must be painted with two coat of synthetic enemal paint and Levels should be written on it. (ii) Rate of painting and writing deemed to be included in the quoted rate
Material and labour for ACP Sheet 3mm thickness of dimesnion (2feet x 6 feet) alongwith radium tap printing text on one side including iron pipe frame and grouted in PCC 1 :3:6 type B:2 (40mm graded stone aggregate foundation) complete all as specified & directed by Engineer-in-charge. Note :- Rate of scaffolding deemed to be inclusive in quoted rate
Matrial and labour of water sample from different locations as directed by Engineer-in-Charge in clean/sanitized bottle of capacity 01 Ltr in front of MES rep, carrying out the Bioligical and Chemical analysis test from the govt approved laboratory and submitting the test result to Engineer-in-Charge for each sample complete all as spcified and as directed by Engineer- in Charge.
Supply and install on load changes over switch 800 Amps, 415 Volts, four pole modular construction confirm to IS /IEC 60947-3 with door interlock and pedlock facility in steel sheet enclosure mechanically operated including disconnection and mounting on 50 x 50 x 5 cm MS angle duly painted with two coat of synthetic enamel balck paint over a coat of red oxide to grouted in 1 :3:6 PCC foundation including electric connection and dismantling existing change over switch complete all as spcified and as directed by Engineer- in Charge.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including 32 x 6 mm GI strip upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including dismantling the old existing earthing complete all as directed.
NASIB ENGINEERS AND CONSTRUCTION
RS ENTERPRISES
SS CONSTRUCTION
M/s Kataria Construction Company
Sandeep Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .