Loading…
Loading…
Tender Value
₹31.8 Cr
EMD Value
₹32 L
Closing Date
20 May 2026, 3:00 pmClosed
MR Kamlesh Kumar Verma(DFLT)
NRDA, NAYA RAIPUR
“Development of Electrical Infrastructure in Newly Developed Areas under Layer-1 and Layer-2, including Construction of 03 Nos. 33/11 kV Electrical Substations at Nava Raipur Atal Nagar, District Raipur (C.G.).”(1st Call)
190142
NIT No:09/EI-L1&2-SS/EEE/CE/NRANVP/2026-27, Nava Raipur Atal Nagar Dist. Raipur, Dated: 28.04.2026
OPEN TENDER
WORKS
18 days
NRDA, NAYA RAIPUR
Required Past Technical Experience: AS PER DNIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
16 documents required · 16 mandatory
Nava Raipur Atal Nagar Vikas Pradhikaran (NRANVP)
WORKS
MR Kamlesh Kumar Verma(DFLT)
OPEN TENDER
PERCENTAGE
OPEN TO ALL
NRDA, NAYA RAIPUR
ENGINEERING
CHIEF ENGINEER OFFICE
90
18.00
No
0
190142
20 May, 2026 3:00:00 PM IST
21 May, 2026 4:00:00 PM IST
2 May, 2026 3:00:00 PM IST
NIT No:09/EI-L1&2-SS/EEE/CE/NRANVP/2026-27, Nava Raipur Atal Nagar Dist. Raipur, Dated: 28.04.2026
“Development of Electrical Infrastructure in Newly Developed Areas under Layer-1 and Layer-2, including Construction of 03 Nos. 33/11 kV Electrical Substations at Nava Raipur Atal Nagar, District Raipur (C.G.).”(1st Call)
3200000.00 INR
BANK GUARANTEE (OFFLINE) Demand Draft (OFFLINE) Fixed Deposit Receipt (OFFLINE)
317715921.92
2
21 May, 2026 3:00:00 PM IST
317715921.92
AS PER NIT
AS PER NIT
AS PER DNIT
29500.00 INR
18d 1h 54m
16 documents required · 16 mandatory
₹29,500
₹32 L
28 Apr 2026
28 Apr 2026
21 May 2026
2 May 2026
20 May 2026
2 May 2026
21 May 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soil
Backfilling: Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Providing and filling in plinth with sand/ Crusher dust under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluidng cost of form work 1 cement:3 coarse aggregate:6 graded stone aggregate
Providing and laying design mix reinforcement cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto floor five level excluding cost of reinforcement and form work. M-20
Providing and laying design mix reinforcement cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto floor five level excluding cost of reinforcement and form work. M-25
Water proofing material: Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.
DPC: Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.
Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete: Thermo-Mechanically treated Bars
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, base of columns and plinth beam in any shape and size.
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Wall of any thickness including attached pilasters, buttresses etc.
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Columns, Pillars, Piers and likes- rectangular or square in shape
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Edge of slab, breaks in floor and walls upto 200mm.
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Columns, beams & walls- circular or any other geometrical shape other than square and rectangular in all sizes
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Beams, lintels, cantilevers & walls
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Weather shade, chhajja, Cornices and mouldings
Providing and placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Dumb bell with central bulb (180mm wide, 8mm thick).
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate primer. Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet.
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 35 mm. thick (single leaf)
Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel, sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size above 200x300mm
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size above 300x300mm
Providing and fixing float glass panes with steel glazing clips and special metal sash putty of approved make in steel doors, windows, ventilators: 5mm thick
Providing and fixing antique/ SS finished brass parliamentary hinges with antique/ SS polished MS screw complete: 150x125x27x5mm
Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 300x16 mm
Providing and fixing antique/ SS finished brass door latch with antique/ SS polished MS screw complete: 300x16x5mm
MS Grill: Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring. 80x1.25mm M.S. Laths
Providing and fixing 27.5cm long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter 1.25mm thick
Providing and fixing ball bearing for rolling shutters.
Providing and fixing mechanical device chain and crank operation for operating rolling shutters
Providing and fixing M.S. fan clamp/ hook for ceiling fan made out of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop.
25 mm thick KOTA stone slab flooring over 20mm (average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sq.m and upto 0.50 sq.m)
Providing and laying double charge/ multi charge (minimum 2.0 mm thick layer) vitrified floor tiles with with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm thickness 9 to 10 mm
Plinth protection: Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK including cutting chases and making good the walls etc., 15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK including cutting chases and making good the walls etc., 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK including cutting chases and making good the walls etc., 32 mm nominal outer dia .Pipes.
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Long body bib cock (500 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Piller Cock (400 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Angle valve for basin mixer and geyser points (450 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Toilet paper holder
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Soap dish plate
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Towel rail (600mm long x 20mm dia)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Towel ring (150 mm dia)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Health foscet (hand jet) with flexible connection pipe (for WC)
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
Providing and fixing water closet squatting pan (Indian type W.C. pan), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White pedestal type
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back half stall urinal of size 460x380x250mm
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm
15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)
12mm thick cement plaster of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand)
6mm thick cement plaster of mix: (ceiling) In Cement mortar 1:3 (1 cement : 3 fine sand)
White washing with whiting to give an even shade. On new work (Three or more coats)
Providing and applying Acrylic washable Distemper or lite economy Plastic emulsion paint having VOC content less than 50gms/lit Minimum two coats up to final finish applied @ 1.25 Kg/ 10Sqm as per relevant I.S. Code 428:2000 (product such as Tractor Uno, Dulux Duval, Berger Bison, Opus Style/lite economy emulsion product such as Asian Tactor Spark, Dulux Pomise sheen, Neroloc Litil Master, Berger Bison Lite, Nippon Superio.) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work
Providing and applying priming coat on steel work with red oxide/ zinc phosphate primer applied @ 0.50 lit /Sqm as per relevant code 3536:1999 ( product such as Asian Zinc phosphate, Dulux Steel primer, Burger Red oxide primer) with all tools tackles and labour etc, complete for the work.
White washing/ Colour washing with lime to give an even shade in Three or more Coats for New surface as per relevant IS code 6278:1971 Consumption of lime 3.50kg /10 Sqm with all tools tackles and labour etc. complete for the work.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing in position G.I. barbed wire (93.8gram/m) to concrete/ wooden/ angle iron posts (straight or diagonal) including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete(Cost of posts, struts to be paid for separately)
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete More than 2 mm to 4mm thickness to make surface even and smooth in line and level
Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give pronusative and water proof finish aunimum 3 coats applied 140 lit/105qm up to final finish as per relevant 1.5. Code 15489:2013 Type-2 Class D, C (Glassy /Semi Glossy finish) (Product such as Asian Apes Dulux Weather Shield Primus E900, Berger Weathercoal Antidust, Nerolac Everlas Excel, Nippon Sumo Etra, Opm Trus flex inclusive of providing abro tapo on edges and articleand cleaning of door. windows, floor and surface as required with all tools tackles and labour etc. complete for the work (With 3Year Warranty)
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.
Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment).
Providing and Displaying Calendula double variety well developed with fresh & healthy foliage in full bloom in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Providing and Displaying Antirrhinum variety, well developed, fresh & healthy multi branched 30 to 45 cm ht, in full bloom with stacking in 30 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Detailed survey of existing road including chaining, leveling, with cross section at 25.0 m intervals and closing survey each day's work, fixing bench marks, painting, taking trial pits and submission of road cross sections, L-sections, quantity statements in computerized prints in five copies in proper files and all type of compliance required by the Engineer-in-charge.
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead as per relevant clauses of section 300.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead as per relevant clauses of section-200 in i),B Cement concrete Grade M-15 and M-20
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing close graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 .A Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with (i) Grading-III Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Providing and Laying Un-reinforced cement concrete without Dowel bars including formwork and expansion contraction & Longitudinal joints as per desing and as per IRC62-2014 over a prepared base as per approved mix design and finishing to lines and grade as per drawing for pavement thickness less than 200mm in low volume roads.(I) PCC Grade M30 with minimum Cement Content @ 375kg/cum.
Providing and planting of 6' to 8' heighted wasingtonia, filipheria/bismarkia novelist plam plants with 1'.6" x 1'.6" depth pit formation and soil preparation, (Mixing organic manure and plant‟s protection insecticide). Up to 4 month maintenance
Providing and planting of 4‟0” to 5‟0” heighted Ficus prestige/Blackiana plants with 1‟6” x 1‟6” depth pit formation and soil preparation, (Mixing organic manure and plant‟s protection insecticide). Up to 4 month maintenance.
Providing and planting of Bogenbelia dwarf, chandni dwarf, kaner dwarf vr flower bearing plants with 0‟9” x 0‟9” depth pit formation and soil preparation work‟s, (Mixing organic manure and plant‟s protection insecticide). Up to 4 month maintenance.
Excavation for drain (Earth work in excavation for as per drawing and technical specification, including setting out,drain/chamber construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Providing and laying mechanically mixed cement concrete with crushed stone aggregate excluding centering and shuttering (with 40mm nominal size graded stone aggregate) 1:3:6 (M-10)
Providing & fixing form work i/c centering and shuttering including strutting, propping etc. and removal of form work for: 18.64.1 Foundation , footing, bases of Foundation /footing /column base/ plinth beam of any shape and size up to plinth level
Supplying, Receiving, Storage, Installation, Testing & Commissioning (SITC) of outdoor, motorized, extendible type Ring Main Unit (RMU), suitable for 36 kV, 50 Hz system, with a rated current of 630 A and short-time withstand capacity of 25 kA for 1 second, insulated with SF₆ gas. The RMU shall be equipped with 2 Nos. three-position Load Break Switches (LBS) with integral earthing switches for incomer and outgoing feeders, and 1 No. Vacuum Circuit Breaker (VCB) panel for transformer protection/control, complete with required protection relays, CTs, and associated control components. The unit shall be complete with all internal busbars, power and control interconnections, interlocks, and standard accessories. It shall be provided with inbuilt Potential Transformer (PT) for deriving 230 V AC supply for auxiliary circuits, along with touch-proof cable end termination kits suitable for cables up to 400 sq.mm. The scope shall include all necessary hardware, gland plates, ferrules, control wiring, indication system, protection scheme, and complete provision for SCADA/FRTU integration, including necessary wiring and auxilary contacts and terminals. The complete work shall include erection, testing, commissioning, and making the system operational in all respects, in accordance with the attached technical specifications, relevant IS/IEC standards, CSPDCL guidelines, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge.
Supplying, Receiving, Storage, Installation, Testing & Commissioning (SITC) of outdoor, motorized, extendible type Ring Main Unit (RMU), suitable for 36 kV, 50 Hz system, with a rated current of 630 A and short-time withstand capacity of 25 kA for 1 second, insulated with SF₆ gas. The RMU shall be equipped with 3 Nos. three-position Load Break Switches (LBS) with integral earthing switches, suitable for use as incomer/outgoing feeders, and shall be complete with all internal busbars, interconnections (power and control), and necessary protection and control components. The unit shall be provided with inbuilt Potential Transformer (PT) for deriving 230 V AC supply for auxiliary circuits, along with touch-proof cable end termination kits suitable for cables up to 400 sq.mm. The scope shall include all accessories, hardware, gland plates, ferrules, control wiring, interlocks, indication system, and complete wiring provision for SCADA/FRTU integration, including necessary wiring, auxilary contacts and terninals. The complete work shall include erection, testing, commissioning, and making the system operational in all respects, in accordance with the attached technical specifications, relevant IS/IEC standards, CSPDCL guidelines, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning (SITC) of 33/11 kV, 5 MVA Power Transformer suitable for outdoor installation, complete with off-load tap changer, copper wound, oil-immersed and naturally cooled type. The scope shall include supply and erection of transformer complete with all standard fittings and accessories such as conservator, silica gel breather, Buchholz relay, oil level indicator, winding temperature indicator (WTI), oil temperature indicator (OTI), magnetic oil level gauge (MOG), pressure relief device, marshalling box, radiators, valves, and earthing terminals. The transformer shall be provided with HV and LV side cable end termination boxes, complete with glands, lugs, ferrules, interconnections, and all necessary hardware for proper termination. The work shall also include filling of transformer oil (if required), filtration, testing, commissioning, and all associated works for making the system fully operational. The entire work shall be executed as per approved drawings, attached technical specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge, complete in all respects. The unit shall strictly conform to the attached detailed technical specifications.
Supply, Installation, Testing & Commissioning (SITC) of 33/0.433 kV, 50 kVA Distribution Transformer, outdoor type, oil-cooled, copper wound, suitable for operation under site conditions, complete with off-load tap changer for voltage regulation. The transformer shall be provided with all standard fittings and accessories including conservator, breather, Buchholz relay (if applicable), oil level indicator, winding temperature indicator, pressure relief device, marshalling box, earthing terminals, and other necessary components. The scope shall also include HV and LV side cable end termination boxes, complete internal wiring, required hardware, connectors, gland plates, and all associated accessories for proper installation and safe operation. The work shall be carried out complete in all respects as per the attached specifications/drawings, relevant IS standards, CSPDCL guidelines, and as directed by the Engineer-in-Charge.
Supplying and laying following sizes XLPE, steel armoured, aluminium conductor power cable of 33 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per specification. . 3 x 400 sq mm
Supplying and laying following sizes one number XLPE, round wire steel armoured, aluminium conductor power cable of 33 KV(E) grade in existing masonry open duct as per specification. . 3 x 300 sq mm
Supplying and laying following sizes one number XLPE, steel armoured, aluminium conductor power cable of 33 KV grade in existing masonry open duct as required. 3C X 400 sqmm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as required : 400 sqmm
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as required : 400 sqmm
Supplying and laying following sizes one number XLPE, steel armoured, aluminium conductor power cable of 11 KV grade in existing RCC/HUME/STONEWARE/METAL/masonry open duct as required. 3C X 240 sqmm
Supplying and laying following sizes one number XLPE, round wire steel armoured, aluminium conductor power cable of 11 KV(E) grade in existing masonry open duct as per specification. 3 x 300 sq mm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required : 240 sqmm
Supplying and making STRAIGHT THROUGH cable jointing with heat shrinkable cable jointing kit including ferrule and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as per specification: 240 sqmm
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as per specification, IS: 9537 (2000, Part 5). 3.5 x 50 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as per specification, IS: 9537 (2000, Part 5). 3.5 x 70 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated , PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as per specification, IS: 9537 (2000, Part 5). 3.5 x 150 sq. mm.
Supplying, laying, glanding, terminating, testing and commissioning of 1.1 kV grade, 2 core × 2.5 sq.mm FRLS PVC insulated, PVC sheathed, steel armoured copper control cable in ready-made trenches/pipes/conduits, including proper dressing, clamping, and routing as per approved layout. The scope shall include providing and fixing of suitable cable glands, lugs, ferrules, identification tags, clamps, cable markers, and all necessary accessories and hardware, along with earthing of armour, termination at both ends, and interconnections for complete and proper functioning. The entire work shall be carried out as per approved drawings, attached specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge, complete in all respects.
Supplying, laying, glanding, terminating, testing and commissioning of 1.1 kV grade, 4 core × 2.5 sq.mm FRLS PVC insulated, PVC sheathed, steel armoured copper control cable in ready-made trenches/pipes/conduits, including proper dressing, clamping, and routing as per approved layout. The scope shall include providing and fixing of suitable cable glands, lugs, ferrules, identification tags, clamps, cable markers, and all necessary accessories and hardware, along with earthing of armour, termination at both ends, and interconnections for complete and proper functioning. The entire work shall be carried out as per approved drawings, attached specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge, complete in all respects.
Supplying, laying, glanding, terminating, testing and commissioning of 1.1 kV grade, 8 core × 2.5 sq.mm FRLS PVC insulated, PVC sheathed, steel armoured copper control cable in ready-made trenches/pipes/conduits, including proper dressing, clamping, and routing as per approved layout. The scope shall include providing and fixing of suitable cable glands, lugs, ferrules, identification tags, clamps, cable markers, and all necessary accessories and hardware, along with earthing of armour, termination at both ends, and interconnections for complete and proper functioning. The entire work shall be carried out as per approved drawings, attached specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge, complete in all respects.
Supplying and making INDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as per specification. 300 sq. mm
Supplying and making INDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as per specification: 300 sq. mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification.
Supply, fabrication and installation of M.S. angle/channel patti of size 75 mm × 75 mm × 6 mm in cable trench inside the substation, complete with cutting, drilling, welding, and proper fixing/alignment. The scope shall include providing and fixing of nuts, bolts, clamps, tie rails, supports, and all other sundry materials required for proper laying and support of cables in the trench. The work shall also include surface preparation and necessary painting for corrosion protection, wherever required. The entire work shall be executed as per detailed technical specifications, approved drawings/design (to be approved by Engineer-in-Charge), and as per instructions and guidelines of the Engineer-in-Charge, complete in all respects.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supply, installation, testing & commissioning of earthing with 50x6 mm Cu Strip & connection complete with earth electrode /plate in yard, ground, trench, control room with nut bolt spring & plain wisher as per Detail's instruction, Guideline (Drg & Design to be approved by EIC).
Supply and laying of 25x6 mm GI strip along with cable and making connections firmly with accessories hard wardres etc required for completenences and as per attached specification direction of engineer ,CGPWD standards and electrical inspectorate standardsand connection
Supply, Installation, Testing and Commissioning (SITC) of Spike Earthing System comprising 2.0 m long, 25 mm dia G.I. rod electrode, driven/installed in ground, complete with earthing pit formation and refilling using approved earthing compound/chemical, coal, salt, and black cotton soil to achieve required earth resistance. The scope shall include providing and laying of G.I. earth riser up to the equipment, connection with suitable clamps, lugs, fasteners, protective pipe, chamber with CI cover, watering arrangement (if required), and all necessary accessories and hardware for complete installation. The work shall be carried out as per approved drawings and substation design, relevant guidelines and standards, and as directed by the Engineer-in-Charge (Drg. & Design to be approved by EIC), complete in all respects.
Supply, fabrication, installation, and painting of MS structural supports made of 100 mm × 50 mm sections for supporting electrical equipment, complete with cutting, welding, drilling, erection, and proper alignment. The scope shall include providing and fixing of all necessary accessories, fasteners, base plates, anchor bolts, clamps, and hardware, along with surface preparation, primer coating, and finishing with approved paint system for corrosion protection. The work shall be executed as per approved drawings, attached specifications, CSPDCL standards, and as directed by the Engineer-in-Charge, complete in all respects.
Supply, Installation, Testing and Commissioning (SITC) of Transformer Yard Development Works for an area of 15 m × 10 m, comprising preparation of yard surface with 150 mm thick layer of morum and 200 mm thick layer of 40 mm size metal (stone aggregate), properly compacted and finished as per standard engineering practice. The scope shall include necessary grading and arrangement for proper drainage to prevent water logging in the yard, along with providing and laying of G.I. pipeline network for watering/maintenance of each earth pit from the water tank, complete with all fittings, valves, joints, and accessories. The entire work shall be executed as per detailed technical specifications, guidelines, and drawings issued by the Engineer-in-Charge, including all materials, labour, tools, and equipment required for complete and satisfactory execution.
Supplying and erecting chain link mesh fencing for electric sub-station switch yard of 2.5 m approx. height from ground level using angle iron size 50 X 50 X 6 mm erected in C.C.foundation 15 X 15 X 40 cm deep at every 2 metre fitted with flat iron support of size 25 X 6 mm on top, bottom and mid way and chain link mesh 50 x 50 mm aparture and 4 mm dia G.I. hard wire securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins to the angle iron at every distance of 30 cms, by iron studs complete duly painted with one coats of red oxide and two coats of approved colour paint as per CSPDCL standards and direction of EIC
Supplying and erecting MS gate of approx. size 3.0 m (W) x 2.0 m (H) in two laps for electric sub-station switch yard fencing frame made of angle iron size 50 X 50 X 6 mm on top bottom and sides fitted with flat iron support of size 25 X 6 mm on mid way horizontaly and square bar of size 8 mm at every 100mm vertically including 3 sets of heavy duty MS hinges and aldrop complete duly painted with one coats of red oxide and two coats of approved colour paint as per CSPDCL standards and direction of EIC.
Supplying and spreading hard stone aggregate 25 mm size in out door switch as per direction of engineer -in-charge
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted/ welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Providing brick masonry work in cement mortat 1:4 (1 cement : 4 coarse sand) with well burnt clay modular bricks having compressive strength not less than 25kg/sqmm at all levels including scaffolding curing etc complete.
Plastering 15 mm thick on brick work/ CC surface with cement mortar 1:4 (1 cement : 4 fine sand) at all levels.
Supplying and laying following size RCC Hume pipe class NP-2 (in standard length of 2 metre) with collar in ground below road, path etc at a depth not less than 50 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as required. 200 mm dia
Design, Manufacture, Supply, Installation, Testing and Commissioning of floor-mounted, outdoor type SF6 insulated, motorized, extendible Ring Main Unit (RMU) suitable for 12 kV, 630 A operation, comprising 2 Nos. Load Break Switch (LBS) feeders for loop-in and loop-out configuration to form a ring main system and 1 No. Vacuum Circuit Breaker (VCB) feeder for control and protection of distribution transformer, having fault level of 21 kA for 3 seconds, complete with Fault Passage Indicators (FPI), inbuilt Potential Transformer (PT) for providing 230 V AC supply for battery charger and control circuits, protection and control accessories, necessary interlocks, indication, internal wiring and all associated hardware required for safe and reliable operation. The RMU shall be complete with cable termination arrangements, earthing, SCADA compatibility provisions with required wiring and auxilary contacts, and all accessories required for safe and reliable operation, complete in all respects as per approved drawings, technical specifications, relevant IS standards, CSPDCL norms and directions of Engineer-in-Charge.
Design, Manufacture, Supply, Installation, Testing and Commissioning of floor-mounted, outdoor type SF6 insulated, motorized, extendible Ring Main Unit (RMU) suitable for 12 kV, 630 A operation, comprising 4 Nos. Load Break Switch (LBS) feeders for loop-in and loop-out configuration to form a ring main system, having fault level of 21 kA for 3 seconds, complete with Fault Passage Indicators (FPI) conforming to relevant IS standards, inbuilt Potential Transformer (PT) for providing 230 V AC supply for battery charger and control circuits, along with all protection and control accessories, interlocks, indications, internal wiring, cable termination arrangements and associated hardware required for safe and reliable operation. The RMU shall be complete with SCADA compatibility provisions including necessary wiring and auxilary contact, earthing arrangements and all accessories required for completeness, as per approved drawings, technical specifications, CSPDCL standards and directions of Engineer-in-Charge.
Design, Manufacture, Supply, Installation, Testing and Commissioning of floor-mounted, outdoor type compact package substation complete with internal lighting, earthing arrangement, padlocking facility and all associated accessories, suitable for 11/0.415 kV operation, comprising HT, Transformer and LT compartments, with interconnection between RMU and transformer through aluminium bus bars and from transformer to LT panel through suitable bus duct/cable arrangement. The HT side shall consist of non-extensible 12 kV, 630A, SF6 insulated, motorized Ring Main Unit (RMU) with 2 Nos. Load Break Switches (LBS) and 1 No. Vacuum Circuit Breaker (VCB) for transformer protection, having fault level of 21 kA for 3 seconds. The transformer shall be 11/0.415 kV, 500 kVA, Level-2, oil-filled type with double wound copper windings and Class-A insulation. The LT side shall comprise 800A Air Circuit Breaker (ACB) as incomer with overcurrent and earth fault protection, and outgoing feeders consisting of 4 Nos. 250A MCCBs and 2 Nos. 100A MCCBs complete with metering, protection and indication. The package substation shall be SCADA compatible with necessary communication ports, complete internal wiring and provision for distribution transformer (DT) metering. The scope shall also include all associated civil works such as excavation, PCC foundation, plinth, grouting and cable trenches, complete in all respects as per approved drawings, technical specifications, CSPDCL standards and directions of Engineer-in-Charge.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 10 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 2 x 6 sq. mm
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. .4 X 10 sq. mm (22 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification.2 X 6 sq. mm (16 mm)
Design, Fabrication, Supply, Erection, Testing and Commissioning of outdoor type, weather-proof, double door feeder pillar, cubical, free-standing, dust and vermin proof, fabricated from 14 gauge CRCA sheet steel, duly reinforced with suitable size angle iron/channel/T-iron/flats as required, complete with all anti-corrosive treatment before powder coating as per specifications, suitable for 415 V, 3 Phase, 4 Wire, 50 Hz supply, including earth bus, lifting hooks for handling in case of large panels, all internal wiring, hardware, supports, nuts and bolts duly galvanized and zinc passivated, complete as required. The feeder pillar shall comprise 1 No. 63A FP MCCB of 35 kA breaking capacity as incomer, 1 No. 63A FP contactor, AOM switch and 24-hour timer arrangement, 1 set of phase indicating lamps for metering and indication, 1 set of 100A TPN aluminium bus bar with colour coded PVC sleeves, and outgoing feeders consisting of 4 Nos. 32A FP MCBs and 4 Nos. 10A SP MCBs, complete in all respects as per approved drawings, specifications and direction of Engineer-in-Charge. Approval of panel design/drawing shall be obtained prior to fabrication.
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as required.
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)Long Point
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) long Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) ,Short Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5), Medium Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) long Point
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 2.5 sq. mm in 20mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 4 sq. mm in 25mm conduit
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator (one module size) electronic stepped type moving all rounds Fan regulator (one module size) electronic stepped type moving all rounds
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Ceiling rose 3 pin 5 amp
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Batten/ angle holder
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments.1200 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 , 300 mm sweep
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 watt {4 feet}
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 36 watt {4 feet}
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement (minimum 90kg per cum), form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required.
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 7 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 700mm long
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification., 7 metre high
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy,painting with one coat of approved steel primer etc. as required. Single Over Hang 1.50 metre Long
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 10 KV surge protection on pole bracket, including connection, earthing etc complete as per specification and furnishing 5 Yrs Warranty certificate from manufacturer. P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 90 watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 80 watt
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3 x 1.5 sq. mm
Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification. 5 KVA with DC bus voltage 180 V
Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification. 42 AH
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia
Supplying of approved make split type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 3 metre of copper piping with insulation, etc complete as per specification: 1.5 ton split type capacity 4500 kcal / hr (3 star).
Installation of split type Inverter/Non Inverter Air Conditioner unit, cooling unit on wall inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification.
Structural steel hot dip galvanized MS angle welded over a base plate including cutting, welding, hoisting and fixing in position with 3 nos. of 12mm diameter fasteners all complete as per direction of Engineer in charge.
Supply, Installation, Testing and Commissioning (SITC) of 12kV Shunt Capacitor Bank of 1200 kVAR capacity, complete in all respects for efficient power factor improvement and reliable operation. The scope shall include supply and erection of capacitor units, suitable mounting structure/stand, discharge resistors, Residual Voltage Transformers (RVTs), Current Transformers (CTs), APFC relay for automatic power factor correction, protective relays, and interconnecting aluminium/copper bus bars. The panel shall be provided with digital multifunction meter (V, I, kVAR, PF, frequency), necessary indicating lamps for ON/OFF/healthy status, and annunciation system for faults such as capacitor failure, unbalance, over-voltage, under-voltage, and over-current conditions. The work shall also include control wiring, power cabling, terminal blocks, ferrules, glands, lugs, earthing arrangement, and all required accessories and hardware for complete installation, testing, and commissioning of the system. Proper protection, switching, and automatic step control of capacitor bank shall be ensured through APFC relay. The entire work shall be executed in accordance with approved drawings, attached technical specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning (SITC) of Battery and Battery Charger System comprising 30V, 180Ah Lead Acid Battery bank (heavy-duty type) complete with automatic battery charger suitable for float and boost charging operations. The scope shall include acid-resistant battery stand, inter-cell connectors, electrolyte, vent plugs, battery terminals, cable connections, and all necessary accessories and hardware required for complete installation. The battery charger shall be provided with necessary metering (voltmeter, ammeter), indication lamps for charging/healthy/trip status, and annunciation for faults such as charger failure, low/high voltage, and DC supply failure. The entire work shall be executed in accordance with approved drawings, attached specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge.
Supplying, laying, fixing, and jointing of 50 mm × 6 mm Copper (Cu) earth strip along the route, including proper alignment and connection with all intermediate steel supports, and terminating with firm connections to the earthing systems at both end stations. The work shall include providing and fixing of ferrules, clamps, fasteners, and all other necessary accessories and hardware required for complete installation. The entire work shall be carried out as per approved specifications, CSPDCL standards, Electrical Inspectorate norms, and as directed by the Engineer-in-Charge.
Providing and fixing of fire-fighting arrangements in transformer yard, comprising installation of 02 Nos. fire bucket stands, each complete with 04 Nos. of 16-litre capacity buckets filled with sand, including proper mounting, painting, and positioning at designated locations. The scope also includes provision and fixing of sign boards with appropriate safety instructions and lettering, along with all necessary fittings, fixtures, and accessories. All items shall conform to relevant IS standards and safety provisions. The work includes supply, transportation, installation, painting, lettering, and ensuring proper visibility and accessibility of fire-fighting equipment, complete in all respects as per detailed technical specifications and as directed by the Engineer-in-Charge.
Supply and providing of safety equipment for electrical installations, comprising safety helmets (06 Nos.), discharge rods (02 Nos.), 33 kV HT insulated hand gloves (02 pairs), safety charts, notice boards, and display of single line diagram (SLD), complete in all respects. The item includes supply, transportation, installation/display at designated locations, and all necessary accessories for proper usage. All items shall conform to relevant IS/IEC standards and safety guidelines. The work shall be executed as per detailed instructions, approved drawings, and guidelines, and as directed by the Engineer-in-Charge. The scope includes proper mounting/installation of charts, boards, and SLD, ensuring visibility and compliance with safety norms, complete.
Supplying, laying and fixing of 50 mm × 6 mm GI earthing strip along the route of 33 kV cable, including proper alignment and installation, with connections to steel supports at regular intervals and termination at both end stations by firmly connecting to the existing earthing system. The work shall include providing and fixing of all necessary ferrules, clamps, nuts, bolts, washers, jointing materials, and other accessories required for complete and effective earthing. The item shall be executed in accordance with approved drawings, attached technical specifications, CSPDCL standards, and Electrical Inspectorate standards, and as directed by the Engineer-in-Charge. The scope includes supply of materials, transportation, laying, fixing, jointing, testing, and commissioning, complete in all respects.
Providing, lowering, laying, aligning, fixing in position and jointing of Electrical Insulating Rubber Mats at all required locations for safety of electricians and technicians against accidental current leakage during operation and maintenance of AC/DC installations, conforming to IS: 15652 (2006). The mats shall be of Class-C insulation, suitable for maximum use voltage up to 33 kV AC (rms) and 240 V DC (rms), with dielectric strength of 65 kV (AC rms) and proof voltage of 36 kV (AC rms). The mat shall be of 3 mm thickness, 1000 mm width, and 10 m length, having anti-skid diamond plate (rough) surface finish, in black or blue colour coding. The scope includes supply of approved materials, transportation, laying, proper alignment, jointing, edge finishing, testing, and commissioning, complete in all respects as per detailed technical specifications and as directed by the Engineer-in-Charge, NRANVP.
Providing and construction of fire-fighting arrangements for 5 MVA transformers, comprising construction of fire separation wall between two transformers and providing burnt oil collection pit/tank of suitable capacity, complete in all respects, as per applicable guidelines, approved drawings issued by the Engineer-in-Charge (EIC), detailed technical specifications, and as directed at site. The item shall include all materials, labour, excavation, RCC works, finishing, testing, and commissioning, complete.
Horizontal drilling: Horizontal directional drilling along roads for laying XLPE HT/ LT, UG cable, for communication cable along with suitable HDPE Duct at various locations as pointed out by departmental officers, includes Survey of site information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming pulling HDPE duct of suitable size in single roll, pulling HT/ LT UG cable through installed , providing barricades and necessary signal lights, closing of pits with excavated earth including cost of HDPE pipe, consolidating pit are, including road restoration/supervision departments, cost of all materials, labour, conveyance, hire charges etc. complete preparation of pit by excavated soil/ hard morum & refilling compacting surface as it is position / horizontal drilling across road for cable laying propose with disturbing present installation as per instruction, Guide line Detail technical specifications as per direction of Engineer in charge. inner dia. 200mm and outer dia. 240mm
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.08 MB
3804529685874296684_152293_6495745972985456256_83543_03 NRANVP-GCC2011 - e Modified R3.pdf
NIT • 1.69 MB
5121964680083443942_67966_04 Guidelines_To_Bidders_EPS_v1.pdf
NIT • 0.52 MB
563950386947432143_152293_5339351042165774030_71450_02 Affidavit2020.pdf
NIT • 0.16 MB
483318747383663570_190142_05 BOQ.xlsx
BOQ • 0.11 MB
Download all tender documents and submit your bid