| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC 364 4 FIRDAUS SHABANA MARKET NEW SABZI MANDI JK COLONY ROAD KANPUR 07 | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹21.3 L Quoted ₹21.5 L | L1 | Accepted-AOC Found reasonable for acceptance |
| 2 | L2₹23.8 L+₹2.4 L (10.9%)Rejected-Finance | ₹23.8 L+₹2.4 L (10.9%) | L2 | Rejected-Finance L1 being accepted |
| 3 | L3₹24.9 L+₹3.4 L (16.0%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | ₹24.9 L+₹3.4 L (16.0%) | L3 | Rejected-Finance L1 being accepted |
| 4 | L4₹27.2 L+₹5.7 L (26.7%)Rejected-Finance | ₹27.2 L+₹5.7 L (26.7%) | L4 | Rejected-Finance L1 being accepted |
| 5 | L5₹28.4 L+₹6.9 L (32.1%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | ₹28.4 L+₹6.9 L (32.1%) | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹28 L
Closing Date
22 Dec 2021, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2021_MES_489830_1
8407/E8_GE (P) NAVY MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Mandovi
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (P) Navy Mandovi
Exempted
17 Jan 2022
23 Nov 2021
24 Dec 2021
23 Nov 2021
22 Dec 2021
8 Dec 2021
23 Nov 2021 - 7 Dec 2021
Amount
Maintenance and overhauling of DG sets of following capacities installed at various locations in INS Mandovi including checking, cleaning, adjusting/ tightening, oiling, greasing and re-seting of existing parts, decarbonising of battery terminals etc, for smooth operation of generator sets and ensuring proper functioning of valves, 'V' belts, pulleys, fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers, vibration dampers, coupling, alternator terminals, carbons brushes, vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc complete all as specified and directed. Note:- Spares shall be measured and paid separately under relevant items of this Schedule
250 KVA Capacity
125 KVA Capacity
63 KVA Capacity
40 KVA Capacity
62.5 KVA Capacity
35 KVA Capacity
Supply only following spare parts, as per existing sample, suitable for DG sets of 125 KVA capacity and make Kirloskar (KCL) complete all as specified and directed.
Lub oil filter element with 'O' Ring
Fuel filter element with 'O' Ring
Fuel hose pipe, steel
Radiator hose pipe kit
Air filter i.e. Inner and outer element
Engine gasket set
V belt for radiator and charging alternator
Supply only following spare parts, as per existing sample, suitable for DG sets of 250 KVA capacity and make Kirloskar (KCL) complete all as specified and directed.
Lub oil filter element with 'O' Ring
Fuel filter element with 'O' Ring
Fuel hose pipe, steel
Radiator hose pipe kit
Air filter i.e. Inner and outer element
Engine gasket set
V belt for radiator and charging alternator
Supply only following spare parts, as per existing sample, suitable for DG sets (04 nos) of 35 to 63 KVA capacity and make Kirloskar (KCL) / Greeves Power complete all as specified and directed.
Lub oil filter element with 'O' Ring
Fuel filter element with 'O' Ring
Piston with pin
Radiator hose pipe kit
Air filter i.e. Inner and outer element
Oil pressure gauge
Engine upper gasket kit
Water pump assy
Turbo charger repair kit
Piston Ring Set
Liner with 'O' ring
V belt for radiator fan
Dismantling oil sump from DG Sets of following capacities, draining out oil, cleaning, removing sediments/ foregin particles from the oil circulation system, refilling/ replacing the oil and refixing oil sump including replacing oil sump gasket and testing complete all as specified and directed.
250 KVA Capacity
125 KVA Capacity
63 KVA Capacity
40 KVA Capacity
62.5 KVA Capacity
35 KVA Capacity
Dismantling fuel injection pump assembly from DG Sets of following capacities, overhauling/ servicing, replacing valves, washers etc, assembling, calibratiing, setting for proper functioning, refixing and testing complete all as specified and directed.
250 KVA Capacity
125 KVA Capacity
63 KVA Capacity
40 KVA Capacity
62.5 KVA Capacity
35 KVA Capacity
Dismantling, removing self starter motor from DG Sets of following capacities, opening up, overhauling/ servicing, replacing carbon brushes with holders, assembling back, refixing and testing for proper functioning complete all as specified and directed.
250 KVA Capacity
63 KVA Capacity
40 KVA Capacity
62.5 KVA Capacity
35 KVA Capacity
Dismantling, removing alternator/ dynamo from DG Sets of following capacities, opening up, overhauling/ servicing, replacing carbon brushes with holders, assembling back, refixing and testing for proper functioning complete all as specified and directed.
250 KVA Capacity
125 KVA Capacity
63 KVA Capacity
40 KVA Capacity
62.5 KVA Capacity
35 KVA Capacity
Dismantling radiator assembly from DG Sets of following capacities by disconnecting inlet and outlet connections, overhauling/ servicing the radiator, clearing/ removing blockages, arresting leakages, assembling back including necessary welding/ brazing as required, refixing, reconnecting and testing for proper functioning complete all as specified and directed.
250 KVA Capacity
125 KVA Capacity
63 KVA Capacity
40 KVA Capacity
62.5 KVA Capacity
35 KVA Capacity
S & F in repairs 400 Amps capacity on load changeover switch including depositing unserviceable change over switch in MES store yard complete all as specified and directed.
S & F in repirs MNX 45 contactor including single core copper cable of 10 to 25 sqmm with suitable lugs for connecting to starter panel including depositing old unsv contactor in MES store yard complete all as specified and directed.
S & F in repairs radiator assy with tank, complete set made up of copper/aluminium fins and tube suitable for 35KVA to 250 KVA capacity DG set of any make complete all as specified and directed.
Supply and fix in repairs lead acid type 12 V / 180 AH battery including initial charging and connecting to the DG set complete all as specified and directed.
Supply and comissioning of battery charger suitable for charging of 12 V / 24 V batteries including charging cables, automatic cut off protection, trickle charging, protective circuit including taking down old unserviceable battery charger and depositing in MES store yard complete all as specified and directed.
Supply and replace/ top up diesel engine oil 15W 40 in various DG sets installed at INS Mandovi complete all as specified and directed.
Supply & filling coolant concentrate as required in the DG oil sump complete all as specified and directed.
Dismantling defective alternator of any capacity from the existing foundation and DG set after removing all electrical connections, transporting to an approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge and original manufacturer, applying insulating varnishing of ‘F’ class, baking in oven, re-assembling the alternator, transporting back to site, re-installing in the same locaton, carrying out alignment of complete DG set, connecting up all electrical connections, testing and commissioning complete all as specified and directed. Notes :- (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
S & F in repairs battery terminals, brass, suitable for 95 AH to 180 AH battery complete all as specified and directed.
Dismantling defective self starter assy of 12/24 volts, repairing, replacing of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, etc, soldering after repairs, re-assembling, refixing at site and testing on completion complete all as specified and directed.
S & F in repairs AVR unit suitable for 35 KVA to 250 KVA DG Set complete all as specified and directed.
S & F in repairs PVC insulated battery lead made from multistranded copper conductor cable of 1.5 mtr length and suitable size (minimum 35 sqmm) including suitable copper/ brass clamps and lugs for fixing on battery terminals and self starter complete all as specified and directed.
S & F in repairs self starter, 24V DC suitable for 250 KVA DG set complete all as specified and directed.
S & F in repairs asbestos rope of 12 mm dia and superior quality for wrapping with the exhaust pipe of the DG set complete all as specified and directed.
M & L for preparation of old surfaces of DG set of capacity uptp 250 KVA, applying one coat of synthetic enamel paint as per existing colour and writing of SM/MES No at easily visible location complete all as specified and directed.
S & F in repairs electronic DG set controller control unit suitable for 40 KVA Capacity DG set including battery charger, relay board, oil pressure sensor, water temperature sensor, complete control wiring, neccessary connections and testing complete all as specified and directed.
S & F in repairs complete wring harness system including necessary electric connections for 35 to 125 KVA capacity DG set of Kirloskar make complete all as specified and directed.
Supplying and adding distilled water in the DG batteries complete all as specified and directed.
Dismantling defective alternator of any capacity from existing foundation and DG set after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and replacing defective TEETH RING (as per existing sample on site), attending to other mechanical damages, transporting back to site, re-installing in the same location, carrying out alignment of complete DG set, connecting up all electrical connections, testing and commissioning complete all as specified and directed. Notes :- (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
S & F in repairs DG set Exhaust Bellow including any cutting and welding works with new nut & bolts of suitable size and testing after completion
S & F in repairs key arrangement for DG set of 63 KVA to 125 KVA capacity and make Kirloskar including suitable engine safety unit, solenoid switch, sensors, gauges complete all as specified and directed.
S & F in repairs lightening conductor assembly upto 2 RM made out of 50 mm dia bore heavy grade galvanised iron pipe alongwith welded flange at one end and galvanised iron reducer socket 50 x 40mm at another end connected with 40 mm bore heavy grade galvanised iron pipe with one end having galvanised iron reducer socket to connect air termination and connector for earth strip duly fixed with necessary nuts, bolts and washers in PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate of size 30cm x 30cm x30cm complete all as specified and as directed. Notes :- 1. Quoted rate shall be deemed to be inclusive of cost of 40mm and 50mm dia bore GI pipe and PCC. 2. Air temination shall be measured and paid separately under relevant item of this Schedule.
S & F in repairs copper air termination rod, 12 mm dia, single pointed, 300mm long, with base plate welded at bottom of termination rod of size 10 cm lenhgth, fabricated out of 25 x 3 mm thick copper strip alongwith making 9mm dia for fixing in fastners complete all as specified and directed.
S & F in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
S & F in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
S & F in repairs porcelain insulator of existing size for isolation of conductor from the building wall upto a height of G+8 floors by providing 15cm long fastners at every 16 cm distance in the wall complete all as specified and directed.
Outsourcing of services to run and maintain including daily maintence of swimming pool installation comprising of 2 Nos filltration plants with circulating pumps, blower, ozone treatment plant, connected valves and suction sweeper etc by employing operator (FGM) in shifts of 08 hours from 0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs every day (2 shifts per day) including sundays and holidays complete all as specified and directed.
Notes: (a) The operater (FGM) shall be ITI holder with 2 years experience in operating similar installation. (b) The shift timming as specifeid in Sch 'A' may be varied maximum upto 1 hour keeping the total operation time of 8 hrs per shift as per site requirement and as directed by Engineer-in-charge. (c) Both pumps shall be operated alternatively. (d) Log sheet shall be maintained by contractor and quoted rate shall be deemed to be inclusive of cost of maintenance of the same. (e) Blower shall be operated as and when required for back washing the filtration plant and the rate quoted shall deemed to be inclusive of operating the blower. (f) The rate quoted shall deemed to be inclusive of cost for maintainance of water circulating pump, blower and suction sweeper, oiling, greasing lubricants and maintaince of connected valves and NRV, replacing nuts, bolts, gasket gland rope etc. (g) The ozone treatment plant blower, dryer and other equipments shall be operated/ maintained responsibly. (h) The contractor shall hand over swimming pool installation to the department in good working condition on expiry of contract period.
Note (Contd--): (j) Operators shall be provided with uniform (black pant and sky blue shirt) and the rates quoted by the contractor shall be deemed to be inclusive of the same. If operators are found on duty without proper uniform as approved, a penalty of Rs 100 per head shall be recovered from the contractor’s due payments. (k) Necessary tools required for the above work services shall be provided to the operators by the contractor without any extra cost. (m) The contractor shall be responsible for operation of valves, retification of leakage of valves pump/pipe line etc including provision of gland packing/ rubber pack sheet etc. All activities shall be entered in log sheet.
Cleaning of swimming pool floor, side walls and steel ladders using suction sweeper fitted with nylon brush complete all as spacified and directed. Notes : (a) Suction sweeper including brush available at swimming pool installation shall be used. (b) Electricity for running of suction sweeper shall be provided free of cost by department. (c) Repairs to suction sweeper/ foot valves including replacement of bolts, nuts, washers and servicing of suction sweeper pump etc as and when required shall be carried out by the contractor without any extra cost to the department. Quoted rates shall be deemed to be inclusive of the same. (d) The rate quoted shall be deemed to include the charges for divers for cleaning the side walls of swimming pool once during every eighth cleaning.
M & L for cleaning of balancing tank floor and side walls, by scrubbing with brush for removing fungi and washing with water after removing all the sediments collected at the bottom of the tank complete all as specified and directed.
Supplying and adding following chemicals for water treatment to keep the swimming pool water free from fungi and bacteria complete all as specified and directed.
Ferric alum of approved quality, ISI marked
Copper sulphate of approved quality
Soda ash of approved quality Note: 3 kg soda ash shall be added to the pool during every alternative cleaning or as required and directed by engineer in-charge.
Bleaching powder of approved quality, ISI marked Note: 8 kg bleaching powder shall be added to the pool during every cleaning or as required and directed by engineer in-charge.
S & F FPBC nylon heavy duty, PVC water suction flexible hose pipe of 100 mm outer dia including 4 nos of suitable nipple pieces for swimming pool complete all as specified and directed.
M & L for maintenance, repair and periodical services to pressure filter of swimming pool by opening the pressure filter and taking out entire old media, scrapping internal/ external surfaces, cleaning and washing thoroughly, applying two coats of chlorinated rubber paint and silver paint on outer surface for pressure filter over a coat of zinc phosphate primer, laying new filter media in the MS cylindrical pressure filters as per specifications and as directed; removing, repairing, welding pipe lines and replacing certain unserviceable parts including painting the under drain system, inlet and outlet pipes including changing gland packing, nuts, bolts & washers etc.; S & F in repairs 02 Nos of pressure gauge of 0-9 Kg/Sqcm and 1 No butterfly/gate valve and testing and commissioning the filtration plant complete all as specified and directed.
M & L for removing fine media from filter bed by opening the filter bed, cleaning the filter media and re-filling the same including replacement of rubber gasket, nuts and bolts etc complete all as specified and directed. Note: Requisite filter media shall be measured and paid under relevant item of this Schedule.
Supply and fill approved quality fine media in filtration plant complete all as specified and directed.
M & L for repairing/ overhauling of centrifugal pump sets of 7.5 to 10 HP capacity, 3 phase, after disconnecting water/ electric connections including cleaning, repairing, machining, greasing, replacing of washers for lock nuts complete all as specified and directed. Note:- Spares required shall be measured and paid separately under relevant items of this schedule.
Supply only ball bearing driving end complete all as specified and directed.
Supply only ball bearing non-driving end complete all as specified and directed.
Supply only Gun metal bush complete all as specified and directed.
Supply only Cast Iron Impeller complete all as specified and directed.
Supply only terminal block complete all as specified and directed.
Supply only PVC blade complete all as specified and directed.
Supply only gland with cover complete all as specified and directed.
Supply only main shaft MS complete all as specified and directed.
M & L for rewinding electric motor of 3 phase 415 volts 50 Hz AC mono block/ centrifugal pump sets of 10 to 7.5 HP capacity after disconnecting (electric/water connections). taking down electric motor from the existing position, inspecting the same, transporting to a reputed workshop for repairs, transporting it back, cutting and removing burnt out winding conductors, rewinding with insulated super enameled copper conductor of same gauge and weight, providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment, connecting up all the electrical and water line connections, testing and commissioning complete all as specified & directed.
Annual Maintenance contract for fully automatic electrically operated passenger lifts (04 Nos) of make "Kone Elevators"; carrying capacity of 08 Passengers (544 kg) to serve (G+ 03 - 01 No) & (G + 7 - 02 Nos) and carrying capacity of 13 Passengers (884 kg) to serve (G+ 05 - 01 No); with AC variable voltage & variable frequency drive (VVVF drive) complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/ without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built-in announcing system without handset (04 Nos, one each in car, machine room & near Ground floor landing door) comprising of all devices and accessories, including repairs/ replacement of all defective and unserviceable parts as per manufacturer's recommendation, attending of breakdown as and when intimated throughout the year for all days including sundays/holidays complete all as specified and directed.
Notes: (i). Maintenance/repair work shall be carried out through trained service engineer from OEM. (ii). The contractor shall sign a MoU with OEM for a period of 1 year from 01 Mar 2022 for carrying out the maintenance and repair work of lifts and shall produce original MoU to Accepting officer . (iii). Contractor shall ensure that routine maintenance is carried out and lifts are maintained in serviceable condition 24 hrs x 365 days.
Inspection and testing of lift by lift inspector authorised by Goa State Govt, for serviceability and safety aspects of lifts and submission of necessary report as per proforma complete all as specified and directed.
M & L for servicing of solar water heater upto 300 ltrs capacity including checking serviceability of individual components and replacing worn out fasteners, gaskets, washers accessories, inspection of the entire system, cleaning of sacrificial anode, rectification of any leaks, tightening of loose electric connections etc. and making system operational complete all as specified and directed by Engineer-in-Charge. Note:- Spares shall be measured and paid separately under relevant item of this Schedule.
Supply and fix in repairs of solar water tube 58x1500mm for the solar water heaters complete all as specified and directed.
Supply and fix in repairs of solar water tube 58x1800mm for the solar water heaters complete all as specified and directed.
S & F in repairs heating element of 3 kW capacity, ISI marked, suitable for storage type solar water heater (as per site requirement) complete all as specified and directed.
S & F trolley mounted (metal body with wheels) suction sweeper, suitable for swimming pool of size 25 m X 12.5 m, with 3 HP motor including starter panel, suitable copper cable of length up to 25 m, PVC heavy duty flexible pipe of 40mm dia and 40 m length, suction sweeping brush etc including complete fittings, testing and commissioning complete all as specified and directed.
M & L for complete servicing of firefighting system consisting of 100mm dia fire pipe, fire cabinet box, fire hose reel drum, fire hydrant valve, manual call point, fire addressible panel, siren/sounder etc including repair/replacement of defective items complete all as specified and directed. Note: Spares required shall be measured and paid separately under relevant items of this schedule.
Supply only manual call point, glass, complete all as specified and directed.
Supply only sounder/siren complete all as specified and directed.
Supply only fire hydrant valve complete all as specified and directed.
Supply only 12 Volts 7ah battery complete all as specified and directed.
S & F in repairs float valve for solar water heater upto 300 LPD capacity complete all as specified and directed.
M & L for earthing complete with steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plate not less than 1.5 mtr below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers etc including 20 mm dia protection pipe, connecting the earth lead to earth connection in the main distribution box with lugs and GI nuts, bolts etc as shown on electrical plate No 3 of SSR Part I including neccessary excavation and earthwork in any strata, PCC earth chamber in PCC 1:3:6, precast RCC chamber cover and testing including taking out old earthing complete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, the entire earthing shall be redone at no extra cost.
SHREE SAI LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD
Shree Ram Enterprises
Prabha Electricals and Communications
Sagar Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .