Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.7 LAccepted-AOC | 1 | Accepted-AOC Accept | |
| 2 | 2₹8.0 L+₹2.3 L (41.4%)Rejected-Finance | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹9.1 L+₹3.5 L (61.7%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | - | Rejected-Technical NOT REGISTERED IN CATEGORY b(ii) and not UPLOADED REQUISITE DOCUMENTS IN SUPPORT OF PAST EXPERIENCE OF SIMILAR WORKS IN MES |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) SRINAGAR
CWE (AF) SRINAGAR
PROVN OF HT DISTRIBUTION AND MISC WORK FOR BP NO 24 TO BP NO 33 AT AF STN SRINAGAR
2023_MES_620201_1
CWE(AF)SGR/SGR-30/2023-24
Open Tender
Civil Works
Item Rate
180 days
AF STN SRINAGAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF SRINAGAR
₹19,200
Yes
8 Jan 2024
22 Sept 2023
21 Oct 2023
22 Sept 2023
19 Oct 2023
7 Oct 2023
Amount
Material and labour for Supply, laying, jointing and testing, HT cable 11000 volts earth grade of cross sectional area 95Sqm 3 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable terminiation is to be made with suitable size of cable glands and aluminium thimbles (for juction boxes etc) for incoming and outgoing cables complete all as specified and as directed. (Note : MS clamps with nuts, bolts washer etc shall be measued and paid separately under relevant items)
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5m depth and getting out for laying of undergrund cable etc in soft/loose type of soil complete all as specified and directed Engineer-in-Charge.
Returing, filling in, including spreading, levelling, watering and well ramming in layers n exc 25cm thick in any type of soil complete all as specified and directed Engineer-in-Charge.
Removing excavated material to a distance n.exc 50 metre and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed Engineer-in-Charge.
Material and labour for supplying and laying un-reinforced precast concrete cable cover class HV, type-I, flat, size 300 x 180 x 40 mm complete all as specified and directed Engineer-in-Charge.
Material and labour for dry and clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up 18 cm complete all as specified and directed Engineer-in-Charge.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminiation heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and all as directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and all as directed.
Material and labour for steel water tubing light grade of dia 100 mm galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/fixed to poles or passing under road crossing, complete all as specified and directed by Engr-in-Charge.
Material and labour for steel water tubing light grade of dia 80 mm galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/fixed to poles or passing under road crossing, complete all as specified and directed by Engr-in-Charge.
M&L earthing complete with copper earth plate electrode 60cmx 60cm x6mm thick burried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) connected to and including copper strip 32x6mm by means of bolts nuts check nuts and washers of galvanised iron or steel including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm grade crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore upto main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all as directed. Note: 1 On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. Note 2. Earth strip and protection pipe upto 7.5 is included in the unit rate of this item. Contractor shall quote his rate accordingly.
CHINAR CONSTRUCTION TRADERS
M/S ZAHOOR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .