Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance NO 33 NEHRU NAGAR FIRST FLOOR 3RD CROSS THENGAITHITTU ROAD PUDUCHERRY 600108 | 600108 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-TPC not admitted due to non submission of the following
1.​Letter of authorization from the Manufacturer/OEM/Authorized Dealer (with valid jurisdiction). ​
2.Experience certificates were not submitted as per Form C of the NIT |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-TPC not admitted due to non submission of the following
1.​Letter of authorization from the Manufacturer/OEM/Authorized Dealer (with valid jurisdiction). ​
2.Experience certificates were not submitted as per Form C of the NIT |
Tender Value
₹18.2 L
EMD Value
₹36,437
Closing Date
31 Oct 2025, 11:00 amClosed
Executive Engineer (Electrical Tender)
O/o Sr. Chief Engineer (Electrical), BSNL TamilnaduElectrical Zone, 4th FloorBSNL Admin Building,No.16,Greams Road,Chennai - 600006
Carrying out the repairs to Diesel Generator sets including replacement of spare parts and other accessories in various TE buildings BTS sites located at ERODE BA. (Rate Contract)
2025_BSNL_252962_1
62/CEE/TNEZ/CH/2025-26
Open Tender
Electrical Works
Item Rate
365 days
Erode
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹36,437
1 Nov 2025
21 Oct 2025
1 Nov 2025
21 Oct 2025
31 Oct 2025
21 Oct 2025
Supplying of Lub Oil, Lub Oil filters and fuel filters for the following capacity DG sets.
For 20 to 40 KVA Engine
For >40 to 63 KVA Engine
above 63 and upto 110KVA
Service charges for carrying out the Oil servicing and DG general checkup work including labour charges, sundries etc. complete as required for DG capacities 20 KVA to 110 KVA.
Supply of Air Filter Assembly along with Air filter hose clips
For 20 to 40 KVA Engine
For >40 to 63KVA Engine
above 63 and upto 110KVA
Cleaning and fitting air filter up to 40 KVA
Cleaning and fitting air filter from >40 to 63KVA
Cleaning and fitting air filter from >63 to 110KVA
Service charges for replacement of air filter assembly i/c labour charges , sundries etc. complete as required for DG capacities 20 to 110 KVA.
Supplying of appropriate grade V Belt
20 to 40 KVA
> 40 to 110 KVA
above 63 and upto 110KVA
Service charges for replacement of V-Belt including labour charges , sundries etc. complete as required for DG capacities 20 KVA to 110 KVA.
Supplying of appropriate steel braided rubber Hoses with Banjo Bolts.
Stainless Steel Braided rubber hose with banjo (18")
StainlessSteel Braided rubber hose with banjo (24")
StainlessSteel Braided rubber hose with banjo (36")
Supply of 1/2 " High Pressure MS Pipe for fuel line including accessories such as bends, elbows etc. complete as required.
Service charges for replacement of stainless steel braided hoses with banjo, including labour charges , sundries etc. complete as required for DG capacities 20 KVA to 110 KVA.
Service charges for laying of High pressure MS fuel pipes of sizes suitable for 20 KVA to 110 KVA capacities.
Supplying and fixing of LLOP sensor and its accessories for DG sets of capacity 20 KVA to 110KVA including labour charges and sundries etc. complet as required.
Supplying and fixing of reputed make mechanical type Hour meter for DG sets i/c accessories and labour charges for fixing etc. complete as required.
Supplying and fixing of heavy grade Door hinges including removing the defective hinges and making the canopy safe and secure complete as required.
Carrying out the repairs to the self starter by replacing the faulty Bendix assembly with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required.
20 KVA to 40 KVA
>40 KVA to 63 KVA
above 63 and upto 110 KVA
Carrying out the repairs to the self starter by replacing the faulty Solenoid switch with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required.
20 KVA to 40 KVA
>40 KVA to 63 KVA
above 63 and upto 110KVA
Carrying out the repairs to the self starter by replacing the faulty armature unit for the self starter with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required.
7.5 KVA to 40 KVA
>40 KVA to 63 KVA
above 63 and upto 110KVA
Carrying out the repairs to the self starter by replacing the faulty Carbon brush base and bushes(self starter) with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required.
20 KVA to 40 KVA
>40 KVA to 63 KVA
above 63 and upto 110KVA
Carrying out the repairs to the self starter by replacing the faulty Starter ring (Crank Gear) with a new one including dismantling from the DG set, refixing back to the DG set after replacement etc. complete as required including all accessories,sundries and labour charges complete as required.
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Supplying and fixing of the New Stop solenoid Assembly suitable for the DG set of capacity 20 KVA to 110 KVA i/c labour charges for fixing etc. complete as required.
Supplying and fixing of the New Thermostat with assembly Suitable for the DG set of below said capacity i/c labour charges for fixing etc. complete as required.
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Attending repairs to the Exhaust Fan
Fan motor coil rewinding
Capacitor for exhaust fan
bearings for exhaust fan
Fan leaf Assembly
Service charges for dismantling, re fixing the Fan and restoring the DG in good working condition.
Supplying of New Radiator Assembly for replacing faulty radiator
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Service charges for replacing faulty radiator by new radiator and restoring the DG in good working condition
Attending to the repairs of the radiator including de-scaling, de-greasing, arresting leakages in the existing radiator i/c labour charges complete as reqd.
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Supplying and fixing of Radiator hose and hose clips completre as required i/c labour charges.
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Supplying new Water Pump Assembly for replacing faulty Water Pump Assembly i/c accessories, labour charges etc complete as required.
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Service charges for replacing faulty water Pump Assembly by new Water Pump Assembly and restoring the DG in good condition
Supplying of New Radiator fan for replacing faulty Radiator Fan i/c all accessories , sundries etc. completre as required.
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Service charges for replacing faulty Radiator fan by new Radiator Fan and restoring the DG in good working condition.
Supplying of New Anti Vibration (AV) Mounting bushes for the DG set
20 to 40 KVA
>40 to 63 KVA
above 63 and upto 110KVA
Service charges for arresting Vibration by installing AV Mounting bushes.
Coil rewinding and repairing work in respect of Alternator of DGs capacity 20 to 30 KVA,including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required.
Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Main Armature Coil (Stator) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material
Auxillary stator coil i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Auxiliary Rotor Field Winding i/c suitable grade new copper Winding wire after deducting the scrap value of old copper wire and insulation material.
Coil rewinding and repairing work in respect of Alternator of DGs of 40 to 63 KVA,including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required.
Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Main Armature Coil (Stator) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material
Auxillary stator coil i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Auxiliary Rotor Field Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Coil rewinding and repairing work in respect of Alternator of DGs of > 63 KVA to 110KVA,including dismantling from the DG set, to and fro transportation to the workshop, checking of allignment after installation etc. complete as required.
Main Field Coil (Rotor) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Main Armature Coil (Stator) Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material
Auxillary stator coil i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Auxiliary Rotor Field Winding i/c suitable grade new copper winding wire after deducting the scrap value of old copper wire and insulation material.
Slip ring and carbon brush assembly i/c labor charge
Compounding transformer rewinding I/c labor charge
Supplying and fixing of the following Alternator Spares i/c labour charges etc. complete as required.
Bearing (20 to 40 KVA)
Bearing (>40 to 63 KVA)
Bearing >63 to 110KVA
Rotating Rectifier (Diode) 20 KVA to 40 KVA i/c labor charge
Rotating Rectifier (Diode) >40 KVA to 63 KVA i/c labor charge
Rotating Rectifier (Diode) >63 KVA to 110 KVA i/c labor charge
Supplying and fixing of Automatic voltage regulator for DG sets of capacity 20 KVA to 110 KVA I /c all accessories and labour charges etc. complete as required.
Supplying and fixing of the following spare Components along with accessories i/c labour charges complete etc. as required.
MCCB (63A, 4 pole) for 40 KVA
MCCB (100A, 4 pole) for 63 KVA
Start/Stop push button assembly
Battery charger SMPS (12V, 10 A)
DC Start/Stop Relay
Single pole MCB up to 32 A
3 Phase 4 Pole 32A Contactor (Coil 230 V AC)
63A, 4 Pole, 4 Way Rotary change over switch
32A, 4 Pole MCB
AVR (Stabilizer) up to 300 VA (for EB contactor coil)
Service Charges
Repairing charges of SMPS / Conventional Battery Charger (12V, 10A)
Patch up work in rusted parts of Canopy of DG by 1mm thick GI sheet fastened using pop rivet and sealing using metal sealer for leak proof.
Attending minor faults in AMF controller (such as Relay failure, Transistor failure, Display failure)
Service charges for repairing the faulty fuel pump
Service charges for repairing the faulty Injector/ Pump Nozzle
Service charges for repairing the faulty Cylinder Head
Service charges for attending the faulty Gasket Set Piston ring/Inlet & outlet gasket
THIRUMALAI ENTERPRISES (BID ID -921705)
SHIELD (BID ID -921573)
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_290774.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .