| Sl No | Description | Qty | Unit | m/s anil traders L1 | M/s YOGESH ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down carefully existing unserviceable point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. | 232 | Per Point | 10 ₹2,320 | 5 ₹1,160 |
| 2.00 | Material and labour for point wiring for one light point /fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. | 30 | Per Point | 200 ₹6,000 | 425 ₹12,750 |
| 3.00 | Material and labour for point wiring for one 5 pin socket outlet 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. | 30 | Per Point | 200 ₹6,000 | 485 ₹14,550 |
| 4.00 | Description all as per item No 03 here-in-before but point wiring for one 5 pin socket outlet, 5/6 Amps on same board with other switch. | 12 | Per Point | 250 ₹3,000 | 100 ₹1,200 |
| 5.00 | Description all as per item No 03 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps on independent board. | 20 | Per Point | 250 ₹5,000 | 490 ₹9,800 |
| 6.00 | Material and labour for point wiring for one light point/fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. | 20 | Per Point | 250 ₹5,000 | 415 ₹8,300 |
| 7.00 | Description all as per item no 06 above but point wiring for two way switch. | 3 | Per Point | 250 ₹750 | 450 ₹1,350 |
| 8.00 | Material and labour for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly including taking out old u/s wiring from conduit complete all as specified and directed. | 20 | Per Point | 250 ₹5,000 | 445 ₹8,900 |
| 9.00 | Description all as per item No 08 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps on independent board. | 13 | Per Point | 250 ₹3,250 | 480 ₹6,240 |
| 10.00 | Material and labour for point wiring for one light point /fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) | 67 | Per Point | 250 ₹16,750 | 490 ₹32,830 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Dec 2025, 6:00 pmClosed
GE(AF) ADM AREA
GE (AF) ADM AREA GWALIOR - 474020
REPAIR/MAINT OF GEYSERS WITH CONNECTED MISC WORKS AND REPAIR/MAINT OF CEILING FAN EXAUST FAN WITH CONNECTED WORK IN CHETAK, CHAMBAL, BHIND COMPLEX, RESIDENCY AREA AND WELCOME MAINTENANCE AT AF STN GWALIOR
2025_MES_737813_1
8536/E8
Open Tender
Civil Works
330 days
GE (AF) ADM AREA GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) ADM AREA
₹90,000
Yes
26 Dec 2025
30 Oct 2025
8 Dec 2025
30 Oct 2025
1 Dec 2025
12 Nov 2025
Amount
Taking down carefully existing unserviceable point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring for one light point /fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Material and labour for point wiring for one 5 pin socket outlet 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Description all as per item No 03 here-in-before but point wiring for one 5 pin socket outlet, 5/6 Amps on same board with other switch.
Description all as per item No 03 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps on independent board.
Material and labour for point wiring for one light point/fan/bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Description all as per item no 06 above but point wiring for two way switch.
Material and labour for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly including taking out old u/s wiring from conduit complete all as specified and directed.
Description all as per item No 08 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps on independent board.
Description all as per item no 10 above but point wiring for two way switch.
Material and labour for point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board. controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor FRLS, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor FRLS single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Description all as per item No 12 above but point wiring for one 5 pin socket outlet, on same board .
Description all as per item No 12 above but point wiring for one six pin socket outlet, 15/5 Amps on independent board. Note:- for Item No 02 to 14 (i) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A. Note for Item ser No 02,06,07 & 10 :- (a)For Lights points one circuit shall have maximum 08 light points. (b) for 05 Amps sockets same board maximum 02 sockets in one circuit with light points. Note for Item ser No 03 , 04 ,05 ,08 ,09 ,12,13 & 14 :- (a) For Socket outlet Ind 6 Amps ( One circuit with maximum 4 points). (b) For Socket outlet 16 Amps ( One circuit of one point only) Gen Note for all item of contract against BOQ :- (a) Being Maint work the quantum of work will be in piecemeal manner with no extra cost to the contractor. (b) The material shall be procured get approved and will be kept in custody of department in advance. This will be issued for repair work as per requirment of site.
M & L for switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified.
M & L for switch flush type single pole two way 5 Amps, 240 volts, white ivory finish complete all as specified.
M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified.
S&F switch socket combination multi purpose, 5 Pin 6 amps, flush type complete all as specified and directed.
S&F switch socket combination multi purpose, 6 Pin 6/16 amps, flush type complete all as specified and directed.
M&L for ceiling rose surface Bakelite two to three terminal, 18 x 50 mm complete all as specified.
M&L in repair for lamp holder insulated body with back plate for batten fitting complete all as specified.
Supplying & fixing in repair for switch bell push, flush type, 5 Amps, single pole, one way , 230 volts AC circuit white ivory finish complete all as specified & directed by Engineer-in-Charge.
Supply and fixing in repair bell Ding Dong ,AC 230 V.single pole all as specified & directed by Engineer-in-Charge.
Supply and Fixing in repair step type electronic fan regulator single phase ,230 volt, 100/120 watt size of PT switch complete all as specified & directed by Engineer-in-Charge.
S&F in repair switch socket combination multi purpose, 5 Pin 6 amps, flush type complete all as specified and directed.
S&F in repair switch socket combination multi purpose, 6 Pin 6/16 amps, flush type complete all as specified and directed.
S&F in repair switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified.
Supply and fixing in repair surface mounted type LUMILINE PLUS NEO light fitting complete 1x 20 watt (4 ft), 6500K , onsite service 2 years , Average life 50000 hrs LED lightning fixture with extruded aluminium housing integrated electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable suitable size. etc complete all as specified and directed. Make :- Havells cat part No LUMILINEPLUSNEOBS20WLED830SPCSSINDS or Wipro cat part No Wipro Garnet 20w Aluminium Led Batten or Jaquar BTI-WHT-LGLZU1X022XC.
Supply and fixing in repair surface mounted type LUMILINE PLUS NEO light fitting complete 1x 10 watt (4 ft), 6500K Average lifr 50000 hrs LED lightning fixture with extruded aluminium housing integrated electronic driver complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper pvc sheathed conductor cable suitable size. etc complete all as specified and directed. Make :- Havells cat part No LUMILINEPLUSNEOBS10WLED865SPCSSINDS or Wipro cat part No/model No Garnet D531027 or Philips Model No - 919515813927_1 / Jaquar BTI-WHT-LGLZ01X020XC .
S&F in repair LED bulk head fitting 10 watt energy saving new generation IP 65 luminatre with opel diffuser complete with lamp all as specified and directed by Engr - in Charge. Make - Crompton Cat part No BLKD-XELLO-10W-CDL or HEXAFT10WLED857SSYMBOPC of Havells or WP1160 wipro garnet 10 watt of Wipro
Supply and fixing in repair Street light fittings LED 35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (25 mm GI pipe light grade ),clamp,nut-bolt and washers all directed by Engineer-in-Charge.
Supply and fixing in repair of sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed .(Note:- Existing MCB in serviceable condition shall be taken out carefully for reuse in the work.
All as per item No 32 above but DB’s 12 way.
Supply and fixing in repair DB Double door TPN 4 way 415 volts complete , fixed properly on MS strips and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified & directed by Engineer-in-Charge.
S&F in repair MCB single pole 6 to 30 Amps, "B" Curve ,240 Volts complete all as specified
S&F in repair MCB Single pole and neutral 40 Amps, 240 Volts complete all as specified.
Supply and fix in repair Four pole MCB TPN 100 Amps, 10 KA, 240 Volts complete all as specified.
Supplying & fixing in repair MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having type DPX 125 conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified & directed.
M&L in repairfor sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor FRLS cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in existing steel / PVC conduit, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FRLS of size 6 Sqmm as earth continuity conductor all as specified and directed.(NOTE :Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
All as per item No 40 as above but 4 Sqmm FRLS cable and 4 Sqmm cable for earth wire.
M&L in repair for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor FRLS cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including conceled PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FRLS of size 6.0 Sqmm as earth continuity conductor all as specified and directed including taking down old submain wiring with any type of conduit.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
All as per item No 42 as above but with copper conductor FRLS cable of size 4 Sqmm with 4 Sqmm earth wire and PVC conduit 20mm dia med grade
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including surface PVC conduit med grade of dia not less than 25mm with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10.0 Sqmm as earth continuity conductor all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
All as per item No 44 but 6 Sqmm cable and 6 sqmm earth wire.and 20mm pvc conduit
All as per item No 44 but 4 Sqmm and 4 sqmm earth wire.and 20mm pvc conduit
M&L in repair for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as required and directed by Engineer-in-Charge.
S&F in repair 35W/36W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 600x600 mm complete with LED tube with driver and all accessories specified and directed by Engr -in- Charge.
S & F in repair for replacement of LED Tube light 18/20 watt crystal glass double side connection complete and inclu. taking out all as specified and directed.
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :-
(a) Ball bearing No 6200
(b) Ball bearing No 6201
(c) Ball bearing No 6202
(d) Ball bearing No 6203
(e) gun metal bushes of any description and size to suit existing motor shaft including grinding & polishing of fan motor shaft to required shape/size.
(f) capacitor of capacity 2.5 mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA)
(g) capacitor of capacity 3.15 mfd (PVC body) (Make:- EPCOS/JYOTI/USHA)
(h) capacitor of capacity 4 mfd (PVC body) (Make:- EPCOS/JYOTI/USHA)
(i) hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods.
(j) PVC canopy of any description and suitable for any type & any make of fan.
(k) PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 230 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
(l) aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 300 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
(m) aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 450 mm sweep.(Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
(n) PVC insulated and sheathed, round flexible cable, three core of size 23/0.0076 with copper conductor in pieces for connecting fans. ( Make :Havell’s / Finolex / Gloster / National/ Plaza )
(o) MS nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete.
(p) rubber real of suitable size of hanging assembly complete.
(q) condensor cap pvc body
(r) 300mm long down rod 20mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified.
(s) 600mm long down rod 20mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified.
(t) 1200mm long down rod 20mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified.
(u) 1800mm long down rod 20mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified.
(v) mild steel fan blade of size 1200 to 1400 mm and of standard thickness (Factory Made) duly balanced and painted of required colour at site complete all as specified and directed.
(w) Exhaust fan clamp (leg) for 225/300mm exhaust fan as per sample (set of 3/4) including rubber packing and clamp bolt complete all as specified and directed
(x) Exhaust fan clamp (leg) for 450 mm exhaust fan as per sample (set of 3/4) including rubber packing and clamp bolt complete all as specified and directed
(y) Exhaust fan frame for 225/300mm exhaust fan as per sample complete all as specified and directed
(z) Exhaust fan frame for 450 mm exhaust fan as per sample complete all as specified and directed
(aa) Exhaust fan Motor for 230mm exhaust fan as per sample complete all as specified and directed
(ab) Exhaust fan Motor for 300mm exhaust fan as per sample complete all as specified and directed
(ac) wall Fan PVC body of 450 mm wall fan as per sample complete all as specified and directed
Taking out & removing old burnt-out windings of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at site workshop and transportation to & fro site, assembling and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
(a) Ceiling fans 1200/1400 mm sweep.
(b) Exhaust fans of 225/230 mm sweep.
(c) Exhaust fans of 300/375 mm sweep.
(d) Exhaust fans of 450 mm sweep.
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 230/300mm sweep all as specified & directed by Engineer-in-Charge.
All as per item No.54 above but suitable for exhaust fan of 450 mm sweep
S&F in repair MS clamps for fixing of fan hook as per sample made out of 5 mm thick MS Falt including necessary cutting, drilling, welding and provision of necessary nut and bolts etc complete all as specified and directed.
M & L for painting of existing fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed.
S&F in replacement of Armature with shaft for ceiling fas 1200/1400 mm sweep as per sample.
S&F in repair of exhaust fan made of strudy engineering plastic complete louvers shutter ,voltage 230 V, 50 Hz, RPM 1200 copper winding of sweep 300 mm complete all as specified and directed.
S&F in repair of exhaust fan made of strudy engineering plastic complete louvers shutter ,voltage 230 V, 50 Hz, RPM 900 copper winding of sweep 250 mm complete all as specified and directed.
S&F in repair of exhaust fan made of strudy engineering plastic complete louvers shutter ,voltage 230 V, 50 Hz, RPM 900 copper winding of sweep 200 mm complete all as specified and directed.
Disconnecting & taking down the existing geyser of any description and any capacity (25/35/50 Ltrs) any make and in any position from the existing location for necessary repairs & maintenance/replacement/painting etc complete all as directed
All as per item No 02 hereinbefore but for Geysers of 50 Ltrs capacity
Supply only the following new parts suitable for Geysers of capacity under BOQ item No 79 & 80 here-in-before:-Note :- (i) The new parts shall be suitable to match with the existing geysers (ii) Fixing element of these items is deemed to be included under the rates quoted by the contractor for respective BOQ item No 78 ,79 &80 here-in-before.
(a) Inner steel tank for 25 Ltrs capacity having wall thickness not less than 1mm
(b) Inner steel tank for 50 Ltrs capacity having wall thickness not less than 1mm
(c) MS outer cover of any size and shape, for geyser of cap 25 Ltr not less than 1 mm thick all as specified
(d) MS outer cover of any size and shape, for geyser of cap 50 Ltr not less than 1 mm thick all as specified
(e) `U’ assembly for 25/50 Ltrs capacity geyser, with rubber gasket
(f) Geyser elements of 1500 watts, 230 volts capacity (Make : Dasspass/Theeta )
(g) Geyser elements of 2000 watts,230 volts capacity (Make : Dasspass/Theeta )
(h) Thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply.(Make : Dasspass/Theeta )
(j) Indication lamp of size/shape as approved for geyser
(k) Fusible plug /safety valve as per sample(s) kept in GE office.
(l) Glass wool for insulation Geysers all as approved.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geysers installed at site and supplying and fixing new PVC connections with nylon braided, 15 mm bore 450 mm long having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geysers installed at site and supplying and fixing new HD PVC connections, 15 mm bore 450 mm long high pressure nylone braided having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed.
M & L for painting of existing Geysers of any description and in any position 25/50 ltrs capacity, with applying one coat of Ducco paint (White) by spray machine including preparation of existing decorated surfaces of geysers including writing MES No. of geysers in capital letters of height not less than 20 mm on geysers body in the pattern and style all as specified and directed.
S & F for MS bottom cover of any size and shape, for geyser of cap 25/ 50 Ltr made out of MS sheet not less than 1 mm thick and as per existing size and shape complete all as specified.
Disconnecting, dismantling & taking up or down existing unserviceable `U’ assembly of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new `U’ assembly to match with the existing system complete all as specified & directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt, 230 volts to match with the existing system complete all as specified & directed by Engineer-in-Charge. (Make : Dasspass/Theeta )
Description all as per item No 77 here-in-before but supply and fixing new geyser element of 2000 watt.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed. (Make : Racold/Dasspass/Theeta )
Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new indication lamp complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable fusible plug/safety valve of any description from geysers installed at site and supplying and fixing new fusible plug / safety valve of shape and size to match with the existing system all as specified & directed.
Disconnecting & taking up or down existing unserviceable copper conductor flexible cable of any size & any description and supplying, fixing, connecting & testing new 3 core copper conductor flexible cable of 50/.025 mm size, PVC insulated and PVC sheathed suitable for 1100 volts grade complete all as specified & directed.
Disconnecting and taking out existing defective/ unserviceable complete industrial type socket with top in sheet metal box, of any description & in any position and Supplying and fixing new industrial type socket, 2 pole + earth 20 Amps, with and including plug top and MCB, 20 Amps, ‘C’ series, single pole in sheet metal enclosure all as specified and directed.
M&L for cutting out holes in existing cement concrete / brick walls built in cement mortar and removing unserviceable/loose/ broken geyser’s mounting bolts including supplying, fixing & grouting new mild steel bolts with screwed end 8 mm dia & 100 mm long along with one washers and one hexagonal nut at screwed end for mounting the geyser on wall using cement mortar 1:3 and making good the disturbed surfaces to match with the existing surface & finishes complete all as directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from 50 Ltrs capacity geyser installed at site and supply and fixing new geyser element of 2000 Watt square flanged type, 230 volts to match with the existing system complete all as specified. (Make:- Recold cat No 65160946 or equivalent make :-Dasspass/Theeta as approved by GE).
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from 50 Ltrs capacity geyser installed at site and supply and fixing new thermostat two in one with cut off facilities and 11” long in size, 230 volts to match with the existing system.. Complete all as specified. (Make:- Recold cat No 3412044 , Dasspass/Theeta or equivalent make as approved by GE)
M & L in repair for Plug Top 16 Amps, 240 Volts three pin complete all as specified. (Make:-Cona/ Leader/ Anchor(Panta)
Disconnecting old unserviceable GI Pipe of any description and supply and fixing/laying pipe GI medium grade 15mm bore including fittings fix on wall or laid under floor complete with all accessories ISI Marked complete all as specified and directed.
Dismantling, Disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs of any Make of any description and in any position, taking out old unserviceable MS inner tank and supply and fixing new MS Inner tank capacity 25 Ltrs of any make complete all as specified and directed.
All as per item No 83 here in before but Inner tank capacity 50 Ltrs complete.
Supplying & fixing in repair MCB single pole (`C’ series ) 6 to 32 Amps capacity suitable for 240 volts having current rating 10 KA complete all as specified and directed. (Make : L&T/Legrand/Siemens)
Disconnecting old unserviceable metal clad plug top & supply and fix metal clad plug top AP-20 2 pin earth. Complete all as directed.
Disconnecting old unserviceable metal clad plug socket and supply and fix metal clad plug socket top AP 20 2 pin earth complete all as directed.
Disconnecting old unserviceable Heating elements and supply and fix Heating element for instant geysrs of any type and description capacity 3 KW complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt of Racold Altro-2SP 25V, 230 volts to match with the existing system complete all as specified and directed. (Make : Racold /Bajaj /Usha)
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt /2000 watt of 9 Hole 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt /2000 watt of 6 Hole 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new thermostat of Racold Altro-2SP 25V/50V with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed by Engineer-in-Charge.
Disconnecting, dismantling & taking up or down existing unserviceable geyser Auto Switch of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new Auto Switch of Racold Altro-2SP 25V/50V with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed.
Fixing only switch socket combination 5 pin, 5 Amp, flush type , AC 230 Volts complete all as specified and directed.
Fixing only switch socket combination 6 pin, 15 Amp ( 3 pin 5 Amp & 3 pin 15 Amp), flush type , AC 230 Volts complete all as specified and directed. (Note for ser Item No 94 & 95 : - Existing serviceable switch socket combination retrieved after taking down of point wiring shall be used under these items)
Fixing only any type batten fittings complete all as specified and directed. (Note:- Existing serviceable battern fittings retrieved after taking down of point wiring shall be used)
Fixing only and connecting & testing serviceable MCB (SP/ SPN/ TPN/ Four pole) upto 63 Amps complete all as specified and directed. (Note:- Existing serviceable MCB retrived after taking down of shall be used)
M/s YOGESH ENTERPRISES (BID ID -3482860)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender8536.pdf
Tender Documents • 0.85 MB
BOQ_826149.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid