Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L1 | Accepted-AOC Awarded being L1. | |
| 2 | L2₹6.5 L+₹32,294 (5.23%)Rejected-Finance | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹6.7 L+₹48,054 (7.79%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L3 | Rejected-Finance Other than L1. | |
| 4 | L4₹8.6 L+₹2.5 L (39.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1. | |
| 5 | L5₹8.9 L+₹2.8 L (44.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1. |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
18 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINTENANCE TO AC, REFRIGERATOR AND OTHER CONNECTED WORK AT 663 R AND O AND REPAIR AND MAINTENANCE TO HIGH MAST LIGHTS AT HQ CIF (K) UNDER AGE (I) CIF (K).
2024_MES_660783_1
CA NO. AGE (I) CIF (K) - 22/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS.
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹19,000
Yes
25 Oct 2024
20 Jun 2024
20 Jul 2024
20 Jun 2024
18 Jul 2024
4 Jul 2024
Amount
Dismantling and lowering to ground for repair, inspecting defective of Window and split type AC of capacity 1.5 and 2 Ton and re-installing the same after repair and descaling of condenser and servicing complete, testing to the complete satisfaction of the Engineer-in-Charge.
Taking out the existing burntout compressure and supply and replacement of compressor sealed unit suitable for ACs 1.5 Ton Capacity flushing , vaccumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including including replacement of strainer, complete all as specified and as directed by the Engineer-in-Charge. Make- Kirloskar/ Tecumshah
Supply and replacement of compressor sealed unit suitable for ACs 2 Ton Capacity flushing , vaccumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including including replacement of copper strainer, complete all as specified and as directed by the Engineer-in-Charge. Make- Kirloskar/ Tecumshah
Material and labour for charging of gas in window type AC of capacity 1.5 Ton after flushing,vaccumising and hydration as per laid down standard practice including replacement of copper strainer, complete all as specified as directed by the Engineer-in-Charge.
Material and labour for charging of gas in split type AC of capacity 2 Ton after flushing,vaccumising and hydration as per laid down standard practice including replacement of copper strainer complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of blower motor of size 1/10 HP for Air Conditioner of capacity 1.5 Ton as per existing model of approved make, complete all as specified as directed by the Engineer-in-Charge. Make: NDO AIR MASTER/FRAC MASTER
Supply and replacement of running capacitor 36 mfd, complete all as specified and as directed by the Engineer-in-Charge. Make: TIBCON/SIEMENS
Supply and replacement of running capacitor 45 mfd, complete all as specified and as directed by the Engineer-in-Charge. Make:TIBCON/SIEMENS.
Supply and replacement of starting capacitor of size 100-120MFD for Air Conditioner upto 2 Ton Capacity, complete all as specified and as directed by the Engineer-in-Charge. Make:TIBCON/SIEMENS.
Supply and replacement of starting capacitor of size 80-100 mfd., complete all as specified and as directed by the Engineer-in-Charge. Make:TIBCON/SIEMENS,
Supply and replacement of box type relay type Model Sr-1622 for Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by department, complete all as specified and as directed by the Engineer-in-Charge. Make:SRIRAM/RENUTROL
Supply and replacement of air filter of window/ split type AC suitable AC 1.5/2 Ton Capacity, complete all as specified and as directed by the Engineer-in-Charge. Male: BLUESTAR/VOLTAS/FEEDER LOYD
Supply and replacement of thermostatic switch of ACs of capacity 1.5 to 2 Ton, complete all as specified and as directed by the Engineer-in-Charge. Make:- Make :- Renutrol/Indfoss or equivalent as approved by AGE(I).
Supply and replacement of PCB assembly for window type Acs of capacity 1.5 to 2.0 ton with remote control, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of PCB assembly for split type Acs of capacity 1.5 to 2.0 ton with remote control., complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of fan blade of ACs of capacity 1.5 to 2.0 ton as per existing, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclousers, single pole and neutral with a two pin and earth plug and socketed complete with one single pole MCB of capacity 20 Amp, 240 volts., complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting electrical connection and taken out to inspect the defect of refrigerator of capacity 165 to 310 Litres including cleaning greasing, oiling of required parts etc and re-installing the same after repair and testing the unit, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of compressor sealed unit for refrigerator of size 165 to 220 litres capicity with copper strainer and including , supplying and charging of gas with necessary welding/soldering for leak proof as required, including commissioning and testing, complete all as specified as directed by the Engineer-in-Charge. Make- Kirloskar/Tecumesh
Description all as per serial item No 19 here-in-before, but of capacity 280/320 litres , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of Freezer with door frame of refrigerator of capacity 165 to 220 litres, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of Freezer with door frame of refrigerator of capacity 286 to 310 litres, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of starting box type relay 1/6 HP for refrigerator, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of Over load protector 1/6 HP for refrigerator, complete all as specified as directed by the Engineer-in-Charge.
Supply and charging refrigerant gas in the refrigerator including satisfactory leak test and vaccum test of capacity 165 to 220 litres including replacement of copper strainer and necessary welding work, complete all as specified as directed by the Engineer-in-Charge.
Description all as per serial item No 25 here-in-before, but of capacity 280/320 litres , complete all as specified and as directed by the Engineer-in-Charge. Make-Kirloskar/Tecumesh
Description all as per serial item No 25 here-in-before, but deep freezer of capacity 280/320 litres , complete all as specified and as directed by the Engineer-in-Charge. Make:- Kirloskar/Tecumeshvoltas/Godrej
Supply and replacement of thermostat switch for refrigerator of any size, complete all as specified and as directed by the Engineer-in-Charge. Make:- IND FOSS/RENUTROL/HITECH.
Supply and replacemet of door gaskets of refrigerator 165 to 310 litres, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of fan motor of freezer of refrigerator 286 to 310 litres, complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting and complete opening of voltage stablizer of capacity upto 10KVA and removing the burnt out unserviceable parts and cleaning, complete all as specified and as directed by the Engineer-in-Charge.
Rewinding with copper enamelled wire as per existing gauge of transformer assembly of voltage stabilizers for following capacity, complete all as specified and as directed by the Engineer-in-Charge :-
All as per item No 32 above but up to 0.5 KVA
All as per item No 32 above but1.0 KVA
All as per item No 32 above but2.0 KVA
All as per item No 32 above but4.0 KVA
All as per item No 32 above but5.0/6.0 KVA
Supply and replacement of boost/buck relay of voltage stablizers of following capacity, complete all as specified and as directed by the Engineer-in-Charge:-
All as per item No 38 above but upto 0.5 KVA
All as per item No 38 above but1.0 KVA
All as per item No 38 above but2.0 KVA
All as per item No 38 above but4.0/5.0 KVA
Supply and replacement of time delat relay PCB card for 0.5 to 10KVA, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of 909V sensing transformer capacity 500ma, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of 909V sensing transformer capacity 1 Amp, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of toggle switch 2way 10Amp, complete all as specified and as directed by the Engineer-in-Charge.
HIGH MAST LIGHTS
Taking down existng unserviceable street/security light fittings along the perimeter wall/fencing/Street light by using ladder in hill areas, HPSV/HPMV/MH/Tube light/LED fittings of any capacity any type from pole/wall afte disconnection the connecting wires , carrying to store yard for necessry repair/replacement of spares etc complete all as specified and as directed.
Refixing only the street light fittings after repair along the perimeter wall/fencing /Street light by using ladder in hill areas, obtained from item No.01 here in before incuding making connections with cables and testng complete all as specified and as directed. Note for Item no 1 &2 : (a) Any new spares including cable required to be replaced shall be measured and paid separately. (b) Necessary T&P, Safety Belt, Aluminium Ladder, Vehivle etc reqd for taking down will be arranged by the Contractor and cost for the same shall deemed to be included in the Quoted Unit Rate.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 4 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 4 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs Cable Junction Box/Distribution Board IP 65 with metric knockouts for cable entry of size 10 to 35 sq mm x 4 core including fastening clamp with LT pole, of suitable size, with locking arrangements including with terminals TPN strip, complete all as specified and directed.
M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge.
M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 6 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge.
M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 10 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge.
M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 16 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Bajaj Cat No. PRAZE F 180L WH NB-A5 TG SD or latest upgraded equivalent model in Wipro/Philips
All as per Ser Item No. 33 here-in-before but of 200 Watts Make: Bajaj Cat No. PRAZE F 240L WH NB-A5 TG SD or latest upgraded equivalent model in Wipro/Philips
All as per Ser Item No. 33 here-in-before but of 250/240 Watts Make: Bajaj Cat No. PRAZE F 300L WH NB-A5 TG SD or latest upgraded equivalent model in Wipro/Philips
Supply and fix Integral LED aviation light luminaire comprising of yellow painted LM6 aluminium alloy housing polycarbonate enclosure including takingdown existing unserviceable aviation light fitting complete all as specified and directed by Engineer-in-Charge. Make: Bajaj / Crompton Greaves/ Havells/Wipro
Taking down in repair of high mast light, Hot dip galvanised Mast 15/16meter high and Luminaires carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old UNSV Winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrirer during raising or lowering and re-installation, testing at site and comissioning after satifactorily repair complete all as specified and directed.
Note :- An amount of Rs. 33,872.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/s Nasir Rasool Dar (BID ID -3052100)
VEDA INFRASTRUCTURE (BID ID -3057738)
M/S M.S TANVEER ENTERPRISES (BID ID -3063800)
M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR (BID ID -3066312)
M/S CLASSIC JK SUPPLIERS (BID ID -3066179)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .