XEN Electrical division No. 1 Shimla-9
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
SH Providing Fire Alarm system thereof
2020_PWD_43315_1
Electrical Div.No1PWD Shimla 2020-21-5325-28 dt.9
Open Tender
Electrical Works
Item Rate
365 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
E.E.Electrical Division No-I Shimla-9
₹42,200
25 Feb 2023
17 Dec 2020
11 Jan 2021
17 Dec 2020
9 Jan 2021
17 Dec 2020
Amount
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification Makes: Bosch Avenar 2000, Siemens Fire Finder XLS Series, Edwards EST3,Honeywell Notifier NFS3030 or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of intelligent Analog Addressable type smoke detector that combine photo Electronic and fixed temp thermal with inbuilt isolator or ( isolator base complete after each detectors), with LED Hard Addressable Having rotary decade Address switches , with Mounting Base Complete as required conforming to BS 5839 /NFPAstandards and duly approved by EN54/UL/VDS respect up to the entire satisfaction of Engineer – in Charge of work.Makes: Bosch FAP-425-OT, Siemens Fire Finder HFP11 + DB-11+Isolator, Honeywell Notifier FSC851+B224BI , Edwards SIGA PHS + SIGA IB or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of intelligent Analog Addressable type Rate of Rise/Fixed Heat Detector complete with LED, hard Addressable having rotary decade address switches with inbuilt isolator or ( isolator base complete after each detectors), with Mounting Base complete as required conforming to BS 5839 /NFPA standards and duly approved by EN54/UL/VDS respect to complete with job in all respect up the entire satisfaction of Engineer – in Charge of work. (Makes: Bosch FAH-425-T-R , Siemens Fire Finder HFPT11+ DB-11+ isolator, Honeywell Notifier FST851+B224BI , Edwards SIGA DHI + SIGA IB or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of intelligent Analog Addressable type Double Action Manual Call Point with inbuilt isolator or ( isolator base /module complete after each 20 detectors/module) isolator module having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 /NFPA standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. (Makes: Bosch FMC- 210DM-G-R,Siemens Fire Finder HMS/S , Notifier FSM500K, Edwards SIGA 278 or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of Addressable Loop powered sounder and addressable strobe / flasher with inbuilt isolator or (isolator base /module complete after each 20 detectors/module) complete with mounting base as required conforming to BS5839/NFPA standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.(Makes: (Honeywell Notifier /Bosch / Siemens Fire Finder/ Edwards or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-inm Charge of work Make PES/Giolite/OMEX/ AGNI or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolator or isolator module flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification (Makes: (Honeywell Notifier /Bosch / Siemens Fire Finder/ Edwards) or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of Addressable Monitor Module with inbuilt isolator or isolator module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). (Makes: (Honeywell Notifier /Bosch / Siemens Fire Finder/ Edwards) or its equivalent as approved by Engineer-in-charge.
Supplying, installation, testing & commissioning of Network camera with integrated video-based fire detection and simultaneous intelligent video analysis. Video shall be processed and analyzed within the camera itself, with no extra hardware required. The video-resolution shall be up to HD with activated video based fire detection. The video-based fire detection shall detect uncovered flames/smoke with minimum 2.4% of the picture width upto 80 mtr. with wide range >60deg. The detection shall detect test fires TF1 to TF8 according to EN54/ ULm FM. For the detection of flames and smoke a minimum illumination level of 8 Lux shall be sufficient. The camera shall provide the following features: - The camera shall have a microSD card slot that uses standard; off-the-shelf microSD (SDHC and SDXC) cards for local storage (min. 7 days) - The camera shall transmit two H.264 streams with 30 frames per second. - The focus shall be set automatically. - The camera shall support 802.1x authentication using a RADIUS (Remote Authentication Dial in User Service) server as per the specification enclosed etc. complete as reqd. POE based Outdoor Housing IK 10 Make :- FIKE , Gamewell, BOSCH, Seimens or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of Booster amplifier 480 watts Frequency response: 60 Hz to 15 khz (+1/3db), Inputs :XLR & phone jack , Input 1, Input 2-4, Impendence :20kΩ, Sensitivity : 1 V balanced , S/N >: >85 dB complete in all respect .Make Honeywell/BOSCH/ATEIS or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing & commissioning of 6 Watts Ceiling loudspeaker Suitable for speech and music reproduction , Sound pressure level at 6 W power / 1 W (1 kHz, 1 m)- 94 dB / 86 dB (SPL), Sound pressure level at 6 W power / 1 W (1 kHz, 4 m)- 85 dB / 78 dB (SPL), Opening angle at 1 kHz / 4kHz (-6 dB)- 180° / 85°, Effective frequency range (-10 dB)- 90 Hz to 20 kHz Make Honeywell/BOSCH/ATEIS or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing & commissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated ,impedance - 1667 Model LBD 3902 Make Honeywell/BOSCH/ATEIS or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing & commissioning of Horn Loudspeaker made with ABS, waterand dust protected to IP 65, Sound pressure level at 15W/1W - 115/103 dB (SPL), Effective frequency range 500 Hz to 5 kHz, Rated power 15W Make Honeywell/BOSCH/ATEIS or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of 2 core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Make Finolex/Polycab/havel's/belden or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of 2 core multistrand 1.5 sq mm annealed copper conductor Fire cable in existing pipe/ channel I/C connection etc.Make Finolex/Polycab/havel's or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of of PVC Conduit Pipe, 25mm medium, ISI Mark with complete accessories. Make: Diplast/Polyplast or its equivalent as approved by Engineer-in-charge.
Supply, Installation, Testing and Commissioning of 19 U Standard rack to place all Av equipment .Make Valrack /Netrack/ Comrack or its equivalent as approved by Engineer-in-charge.
Insat Techno Services
TARUN FIRE SYSTEM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .