Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | L1 | Accepted-AOC Found lowest and resonable | |
| 2 | L2₹52.5 L+₹5.9 L (12.7%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹53.7 L+₹7.2 L (15.4%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L3 | Rejected-Finance In order but L3 | |
| 4 | Rejected-Technical 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | - | Rejected-Technical No remark against the firm in WLR |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
4 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U)E/M Meerut
Roorkee road Meerut
REPAIR/REPLACEMENT OF LT CABLES, MCCBS AND ALLIED WORKS IN SOUTH AREA UNDER AGE E/M ELECT SUPPLY AT GE (U) E/M MEERUT CANTT
2022_MES_516811_1
8418/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U)E/M Meerut
₹92,000
Yes
29 Jun 2022
6 Apr 2022
6 May 2022
6 Apr 2022
4 May 2022
20 Apr 2022
90 days
Amount
Excavation in trenches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick with soil complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M & L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for measurement and payment.
M & L Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other complete all as specified and directed.
Supply & Laying jointing, testing and commissioning LT XLPE, PVC insulated, PVC sheathed armoured LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, in ducts, on poles, in trenches and under roads etc including taking down complete of following sizes
(a) 400 Sqmm, 3.5 core.
(b) 240 Sqmm, 3.5 core.
(c) 185 Sqmm, 3.5 core.
(d) 150 Sqmm, 3.5 core.
(e) 120 Sqmm, 3.5 core.
(f) 95 Sqmm, 3.5 core.
(g) 70 Sqmm, 3.5 core.
(h) 50 Sqmm, 3.5 core.
(j) 35 Sqmm, 3.5 core.
(k) 25 Sqmm, 4 core.
(l) 16 Sqmm, 4 core.
(m)16 Sqmm, 2 core.
Supply & fixing or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe.
(a) 80mm bore
(b) 50mm bore
(c) 40mm bore
M & L for boring in any type of soil under road 1.5 Mtr below the top surface of road by conventional method complete for passing through 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed.
NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 300 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black and white from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete including down old poles, all as specified and directed.
S&F stay assembly comprising of 7/10 SWG galvanised stay stranded wire of required length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 14mm dia, 400mm long stay bow with 20 mm dia 180 cms, long stay rod with threaded end, GI nut & washers GI stay plate 230 x 230 x 6mm thick plate 2 Nos thimble, MS clamp made out of 50 x 6mm flat iron, loop insulator 90mm x 140mm dia hole, 25mm porcelain, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation complete all as specified and shown in electrical plate No 1 of SSR Part I. including taking down, all as specified and directed.
M&L aluminium conductor steel reinforced (ACSR) any size as per site requirement as directed straining properly on insulator and binding with aluminium tap/ binding with connectors, jumpers etc including taking down old U/S conductor complete all as directed by Engr-in-Charge
M&L pin type, porcelain, vitreous, white or green insulator (LT), 100mm height and 65mm dia, 1100 volts grade including one galvanised MS spindle, two GI washer and one GI nut complete including taking down old U/S insulators.
M&L sackle type, porcelain, brown, white or green insulator for working pressure1100 volts grade of 90mm dia and 75mm height including galvanised MS strap of 31mm x 3mm size, 12mm dia insulator bolts, washers and nuts, complete including taking down old U/S insulators.
M&L cross arms of MS angle or channel iron including flat iron clamp with bolt, nut & washers drilling for bolts in any shape or size as indicated or directed and including painting with one coat of red oxide primer and two coats of aluminium paint before fixings and and one coat of aluminium paint after fixing including taking down old U/S complete all as specified and as directed by Engr-in Charge.
Scraping, cleaning and preparation of old surfeces of steel tubular pole (9 Mtr long) steel fitting complete and M&L for painting with one coat for aluminium paint after preparation of the steel surfaces and then applied strap with two coats black & red paint in HT poles and two coats black & yellow paint strap alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30cm and number of strap shall be 05 Nos. and as directed by Engr- in-Charge.
M&L for Restring / tightening of ACSR conductor of any size & GI earth wire of any size of LT over head line on existing poles duly straining properly binding with extra aluminium binding wire to insulators all as directed by Engr-in-Charge.
M&L for Cutting of worn out aluminium cable terminal lugs from the LT cable criming of new aluminium cable core and fixing with transformer, Panel MCCB terminal stud including cutting/dressing of cable, excavation surface after providing sand cushioning and brick protection as specified and directed by engineer in charge.
M&L for Triming of tree branches up to 75mm dia to cleen the route of LT over head lines arround the 3 Mtr from the external conductors including removing the cut branches from site and depositing at places all as directed by Engeer in Charge.
Supply and fix FRP junction box made out of 2mm thick suitable for pole mounted out door type complete with FI clamp 40mm X 4mm with nuts, bolts, washers and including aluminium bus bar 4 pole X 40 Amp and one MCB SP 10 Amp, 10KA complete all as directed.
Supply, fixing, installation and testing LT pannel out door (Kiosk type) type, wheather & vermin proof MS sheet housing 3.15mm thick, double door front & rear openable type mounted on 50 X 50 X 6mm angle iron frame, floor mounted type with coloured horizontal Tinned aluminium bus bar 4 pole mounted on insulators of rating 200 Amps, one MCCB, 4 pole 100 Amps, 25 KA 415 volts at incoming supply. The panel size not less than 600x450x300mm with cable gland, duly powder coated, locking arrengement complete and including grouting in PCC block of suitable size including taking out old panel, all as directed by Engr-in-Charge.
Supply and fix in repairs sheet metal busbar chamber for multiple Nos of service connection made out of 2mm thick CRCA sheet powder coated suitable for pole mounted outdoor type complete with 04 pole aluminium colour code busbar, 200 Amp rating, 30cm long horizontal type installed on porcelain insulators including fixing on pole FI clamp 40mmx4mm with nuts, bolts and washers complete all as specified and directed.
Supply & Fixing PVC line separator sprial type suitable for 2 wire complete all as specified and directed.
Supply & Fixing PVC line separator sprial type suitable for 4 wire complete all as specified and directed.
Surface dressing/levelling/ cleaning of surrounding area of 2/4 pole/ plinth mounted transformer structure/ E&M sub station including removing of tree branches small tree plants tarbushes etc complete all as directed.
Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected g, soldered and revetted to earth platealvanised earth lead wire 4.0mm dia by means of bolts, nuts , check nuts and washers of galvanised iron or steel. GI earth wire will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I, including taking out old earthing , all as specified and directed.
Supply and fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing of following sizes:-
(a) 35 to 70 Sqmm 3.5 core
(b) 95 to 150 Sqmm, 3.5 core cable
(c) 185 to 400 Sqmm, 3.5 core cable
Taking out of LT cable of any size and make with necessary excavation for finding of fault and necessary repairing and relaying at the same site after repairing and make functional including testing of cable complete all as specified and directed by Engr-in-Charge NOTE :- Straight through, excavation , returning filling and removing will be measured separately. Existing brick and sand will be used for relaying of cables.
S&F in repair MCCB, 4 pole, 50 Hz, 250 Amps, 16kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 200 Amps, 16kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 160 Amps, 16kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 100 Amps, 16KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 63 Amps, 16KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 400 Amps, 25KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 630 Amps, 36KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
Microsys Controls India
Jain Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .