Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.8 L+₹1.9 L (5.64%)Rejected-Finance | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹35.3 L+₹2.4 L (7.15%)Rejected-Finance | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹36.7 L+₹3.8 L (11.4%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹37.0 L+₹4.0 L (12.1%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L5 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineer services AF Stn Adampur 144103
MISC REPAIRS TO CERTAIN BLDGS INCL E/M SERVICES IN VAYU VIHAR AT AF STN ADAMPUR.
2023_MES_605218_1
GE/AF/ADM-20/2023-24
Open Tender
Civil Works
Item Rate
180 days
Under GE AF Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹80,000
Yes
2 Sept 2023
23 Jun 2023
13 Jul 2023
23 Jun 2023
12 Jul 2023
6 Jul 2023
24 Jun 2023 - 5 Jul 2023
Amount
B/R WORKS
PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified.
Reinforced cement concrete, type B-1,(1:2:4), (nominal mix) using 20 mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in kitchen shelves and the like complete all as specified.
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends, or edges of landings etc. and cutting chases for concealed water tubing, concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, in brick walls, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with rough finished surfaces of concrete, complete all as specified.
Factory made 35 mm thick ,2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all all as specified.
Factory made 2nd class hard wood rail and style, thicknesss of shutters,35 mm, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated,etc complete all all as specified.
Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, thickness 30 mm,etc complete all all as specified.
Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, suppling & fixing in opening, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified.
Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified.
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 300 mm long, complete all as specified.
Mild steel helical door spring 200mm, ordinary rat tail rod pattern including roller and roller plate ISI marked, complete all as specified.
Stainless steel butt hinges,100mm long, ISI marked, complete all as specified.
aluminium anodised handles cast type 125 mm long, ISI marked complete all as specified.
Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, IN REPAIRS, complete.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples all as specified.
Stainless steel conduit, not less than 20 mm bore, cut to size and erected in position as curtain rod on backets, including SS decorative finials & brackets fixed to walls with PVC rawl plugs & SS screws, IN REPAIRS, complete.
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165,complete all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Factory made steel windows with side hung shutter with glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, complete.
Factory made steel windows with side hung shutter without glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, complete.
Steel windows or ventilators, fixed type made of MS sheet 1.25 mm thick box type (primer coated), ERW hollow 'P' section of size 60mm x 25 mm complete all as specified. NOTES APPLICABLE TO SERIAL ITEM NO. 21 TO 23: (a) Profile section used under these items shall be 'P' tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable.
Pressed steel frames made out mild steel sheet 1.25 mm thick, for doors with one or more rebates including necessary fixing lugs, 100 mm size butt hinges ISI Marked, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC (1:3:6) type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified for size of frame: -
105 mm x 60 mm
125 mm x 60 mm
Water Proofing Treatment to RCC sunken surfaces comprising of :
Rendering 15 mm thick (Average thickness) rendering on sunken surfaes including flashings, finished even and fair in cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
LDPE sheet 150 micron laid over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m & adjoining vertical surfaces including applying bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces complete all as specified. NOTES: For Guarantee of Water Proofing Treatment refer PS clause 11.5 of CA.
Supply only water proofing compound (WPC), ISI marked, complete all as specified.
uPVC pipes, 160 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed to wall with PVC brackets as SWR / rain water pipes, IN REPAIRS, complete all as specified
uPVC/PVC bends any radius, suitable for uPVC soil waste discharge pipes 160 mm external dia complete all as specified.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified.
40 mm thick, cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Machine cut Kota stone slab flooring 16-22 mm thick, area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid in floors over & including 20 mm thick (average thickness) cement mortar (1:4) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing (Granite finish) complete, all as specified.
Kota stone slab 16-22 cm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick (average thickness) cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles 7-8mm thick, area of each tile exc. 0.13 Sq.m but n. exc. 0.18 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7-8 mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7-8 mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7-8 mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m on vertical surfaecs as in skirting dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 10 mm thick plaste in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Rendering 5 mm thick on fair faces of concrete surfaces, finished fair and even on ceiling surfaces in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. NOTE: Supply only WPC will be measured and paid for separately under respective item of BoQ.
One coats of white wash on old ceiling surfaces, including preparation of surfaces, complete all as specified.
Three coats of white wash on new ceiling surfaces, including preparation of surfaces, complete all as specified.
Two coats of white wash on old wall surfaces, including preparation of surfaces, complete all as specified.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer.
Complete removal of existing treatment from plastered wall surfces and applying the following including preparation of the surfaces to the entire satisfaction of EIC: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer.
Complete removal of existing treatment from plastered wall surfces and applying the following including preparation of the surfaces to the entire satisfaction of EIC: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer.
NOTES APPLICABLE TO SERIAL ITEM NO. 47 TO 51: (i) Entire quantity of material for this work shall be procured by the contractor from manufacturer's Depot & deposit the same with Enginer-in-Charge and same shall be issued to contractor on daily basis as per consumption at site. (ii) The work shall be got executed through paint manufacturer/ authorised applicators of manufacturer's as specified in relevent PS clause.
Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
Figured glass pin head type 4 mm thick, and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq. m in each pane complete all as specified.
Applying one coat (finishing coat) of synthetic enamel paint, including preparation of old painted wood and wood based surfaces of any description not other wise described over 10cm width or girth and complete all as specified.
Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood (new) based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces complete all as specified.
Applying one coat (finishing coat) of synthetic enamel paint including peparation of old painted steel & iron surfaces of any description not other wise described over 10cm width or girth, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified.
Writing letters or figures by specialist / professional painter (Block, Roman, Italic or indian) with thick black synthetic enamel paint not exc. 15cm height on white base complete all as specified.
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking up or down steel tubing and connections from existing location, complete all as specified of size: -
15mm bore
20mm bore
500 litre capacity, any colour, three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, IN-REPAIRS, complete all as specified including the following acessories: - (i) Brass ball valves, high pressure, with GI rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. P-6510 or equivalent make mentioned in Appndix 'B'.
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIR, complete. MAKE:PRAYAG Cat No. P-6518 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. P-6508 or equivalent make mentioned in Appndix 'B'.
Pillar cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. P6302N or equivalent make mentioned in Appndix 'B'
125mm size overhead ABS shower with cast copper alloy chromium plated arm 225 mm long with flange and fixed in position, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BS-76 or equivalent make mentioned in Appndix 'B'.
Stainless steel towel rail 600 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BA-10S or equivalent make mentioned in Appndix 'B'.
Glass shelf 300 mm long and fixed to wall with chromium plated brass screws and rawl plugs, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BEA- 49 or equivalent make mentioned in Appndix 'B'.
PVC connections 15 mm size of length 450 mm with PTMT nuts, IN REPAIRS complete all as specified.
Stainless steel soap dish, IN REPAIRS complete. MAKE: PRAYAG Cat No. BA-15S or equivalent make mentioned in Appndix 'B'.
Stainless steel (304 grade) grating with frame, with or without hole 100-110 mm size, IN REPLACEMENT, complete all as specified.
Vitreous China squatting pan 'orissa' pattern, size 580 X440mm white, integral foot rests, including 'P' or 'S' trap and saintary connection socket to fit WC outlet including connection to trap , to flusing pipe, anti syphonage pipe etc complete including making good to floor, IN REPLACEMENT, complete all as specified. MAKE: PRAYAG or equivalent make mentioned in Appndix 'B'
PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appndix 'B'
Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPLACEMENT,, complete all as specified. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appndix 'B'
Stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 940mm x 460mm x 203 mm with bowl size 354mmx 405mmx 203mm,IN REPLACEMENT complete. MAKE:PRAYAG Cat No. 1342D or equivalent make mentioned in Appndix 'B'.
Steel plate rack made of stainless steel 0.6mm thick over all size 610 x 760 x 254 mm IN REPLACEMENT complete all as specified
uPVC pipes, 75 mm bore external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors / fixed to wall as SWR pipes, IN REPAIRS, complete all as specified
uPVC/PVC bends any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, IN REPLACEMENT, complete all as specified.
uPVC / PVC 75 mm bore floor trap including jointing with solvent and embedding in cement concrete type B-1 (1:2:4), IN REPAIRS, complete all as specified.
uPVC / PVC 32 mm dia collapsible waste pipe, IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. 3272 or equivalent make mentioned in Appndix 'B'
Cast iron soil, waste and vent pipes, spun type, 75 mm bore, ISI marked (IS:3989), in any length with or without ears, with cement joints, fixed to walls with and including mild steel clamps, IN REPAIRS, complete all as specified.
Cast iron soil, waste and vent pipes, spun type, 100 mm bore, ISI marked (IS:3989), in any length with or without ears, with cement joints, fixed to walls with and including mild steel clamps, IN REPAIRS, complete all as specified.
Cast iron bends 75 mm bore (any radius), diminishing pieces or tapers (largrer bore measured) with oval acess door, ISI marked, IN REPAIRS, complete all as specified.
Cast iron bends 100 mm bore (any radius), diminishing pieces or tapers (largrer bore measured) with oval acess door, ISI marked, IN REPAIRS, complete all as specified.
Cast iron branch pieces, 75 mm bore, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches suitable with oval access door, ISI marked, IN REPAIRS, complete all as specified.
Cast iron branch pieces, 100 mm bore, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches suitable with oval access door, ISI marked, IN REPAIRS, complete all as specified.
100 mm bore cast iron sanitary connections short connections pipe of length upto 300 mm, IN REPAIRS, complete all as specified.
Cast iron floor trap, 75 mm bore including jointing to waste pipe set in cement concrete type B-1(1:2:4) of size 200 mm x 200 mm x 250 mm, complete all as specified.
INT ELECTRIFICATION WORKS
Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One light point controlled by two nos. 2-way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole two way, 6 Amp complete all as specified.
Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Electric buzzer AC 230 volt, single pole, Ding Dong type complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, step socket type, single phase, IN REPLACEMENT complete all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type and including MCCB 4 pole 63 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp, complete all as specified.
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead including test point complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.3.3.1 of contract, IN REPAIRS. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made precast PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Environment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K, IN REPLACEMENT, complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 10 W lighting fixture, 6500K, lumen output should not be less than 90 lumens per watt IN REPLACEMENT, complete. MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 20 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt IN REPLACEMENT, complete. MAKE: Havells Cat No. LUMILINESMART20WLED865PCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
DEMOLITION & DISMANTLING WORKS
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and removing from site all as specified.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening after easing adjusting and minor REPAIRS complete all as specified.
Dismantling floor, hearth or wall tiling, stone slab(s) including cement mortar bedding and removing rubbish off the premises complete all as specified.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided all as specified.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided all as specified.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.
Taking down carefully existing electric water heater of any description and re-fixing same or other location with all accessories complete all as specified.
NOTE: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
JAI DURGA CONSTRUCTION COMPANY
N S ENGINEERS
siddharthenterprises
M/S GURBACHAN SINGH
AAR KAY BEE ENTERPRISES
LABH SINGH AND SONS
M/s Sahib and Company
J.K & Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .