Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹77.3 L
EMD Value
₹1.5 L
Closing Date
7 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRSGCC, April 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non-Compliance to the above will lead to summary rejection of your offer
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one inwhich tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender,orTwo similar works each costing not less than the amount equal to 40% of advertised value of thetender,or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. For details regarding submission of self attested documents/certificates, please refer 'Important instructions to tenderers for open tenders costing more than Rs.50 lakhs available at documents section. Similar nature of work is defined as following, " Works involving wiring / lighting with 240 Volt, 1 Phase and 415 Volt, 3 Phase system with control gear and protection arrangements in residential buildings or service buildings or railway stations / yards or colony / highway lightings " .. (Ref:CEGE/SR Ltr No.E.252/I/8/G dtd 02-04-2026 ,Annexure I, SL.No 3) .Tenderers should mandatorily submit Work completion certificate issued by Competent Authority. In case of experience certificate submitted by tenderer for composite works, experience certificate shall clearly specify the executed cost of Electrical work duly certified by Experience Certificate issuing authority Non compliance to above will lead to summary rejection of your offer.
12 conditions · 9 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Chennai Egmore(MS)-Villupuram(VM) section-Kodambakkam-Re construction of staff quarters Type-II-48 Units for essential staff in lieu of Type-I quarters 38 A-P,39 A-P & 40 A-P Electrical arrangements thereof
ME-29-II-1111-2026~SR
ME-29-II-1111-2026
Open
Works - General
180 Days
Chennai, Tamil Nadu
₹0
₹1.5 L
13 Nov 2026
13 Nov 2026
23 Nov 2026
89 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 77,27,636 | ||
| — | — | — | Above/ 260250.00 Below/P | ||
| a)Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. b)Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 750.00 | — | — | |
| — | — | — | Above/ 19152.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material atleast 6m away from track centre within railway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer in charge at site. | — | 36.00 | — | — | |
| — | — | — | Above/ 203940.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site.NOTE: i)Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest.ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices.iii)The finished level should match with surface level properly | — | 36.00 | — | — | |
| — | — | — | Above/ 12000.00 Below/P | ||
| Laying/leading of 4 core 16 sq.mm LTUG Aluminium cable in the excavated trench,Threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs, sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site.Note:- 4Cx16 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 24650.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUG Aluminium cable in the excavated trench,Threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs, sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site.Note:- 4Cx35 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 850.00 | — | — | |
| — | — | — | Above/ 20500.00 Below/P | ||
| Laying/leading of 4 core 70 sq.mm LTUG Aluminium cable in the excavated trench,Threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs, sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site.Note:- 4Cx70 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 29500.00 Below/P | ||
| Laying/leading of 4 core 185 sq.mm LTUG Aluminium cable in the excavated trench,Threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs, sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site.Note:- 4Cx185 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 39150.00 Below/P | ||
| Laying of 50 mm dia High Density Polyethylene pipes in the excavated trench,clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site.Note: 50mm dia HDPE pipe alone will be supplied departmentally. | — | 1350.00 | — | — | |
| — | — | — | Above/ 30000.00 Below/P | ||
| Laying of 63 mm dia High Density Polyethylene pipes in the excavated trench,clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site.Note: 63mm dia HDPE pipe alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 21500.00 Below/P | ||
| Laying of 110 mm dia High Density Polyethylene pipes in the excavated trench,clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site.Note: 110mm dia HDPE pipe alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 21000.00 Below/P | ||
| Installation, Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure,provision of cover etc, complete including supply /leading / laying / burying and concealing of GI strip 32 X 6 mm along with proper sleeve from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site.Note:1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022.2) LT Earthing Electrode alone will be supplied Departmentally. | — | 14.00 | — | — | |
| — | — | — | Above/ 6948.00 Below/P | ||
| Erection, Testing and commissioning of 4 way Floor Mounting Type MCCB DB with 250A,FP,MCCB as Incomer along with 4 No's of 63A,FP,MCCB's as outgoing including all cable termination at both Incoming and Outgoing sides complete and as per industrial practices complete in a manner as directed by Senior Section Engineer in charge at site.Note: MCCB DB,MCCB's alone will be supplied Departmentally | — | 2.00 | — | — | |
| — | — | — | Above/ 4092.00 Below/P | ||
| Installation, Testing and Commissioning of 63A TPN Switch Dis-connector Fuse Unit along with Enclosure onto wall or elsewhere using suitable mounting arrangements including all cable terminations complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 63A TPN SDF Unit with Enclosure alone will be supplied Departmentally | — | 12.00 | — | — | |
| — | — | — | Above/ 4092.00 Below/P | ||
| Installation, Testing and Commissioning of 32A TPN Switch Dis-connector Fuse Unit along with Enclosure onto wall or elsewhere using suitable mounting arrangements including all cable terminations complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 32A TPN SDF Unit with Enclosure alone will be supplied Departmentally | — | 12.00 | — | — | |
| — | — | — | Above/ 35700.00 Below/P | ||
| Installation, Testing and commissioning of SPN MCB DB with 25A,DP,RCCB as Incomer along with (6 No's of 20A,SP+4 No's 10A,SP) MCB's as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete including all cabling and termination works at both incoming and outgoing ends complete as per site conditions and as per industrial practices in a manner as directed by Senior Section Engineer in charge at site.Note: MCB DB,MCB,RCCB Cable adaptor box etc alone will be supplied Departmentally | — | 50.00 | — | — | |
| — | — | — | Above/ 1670400.00 Below/P | ||
| a)Supply and Drawing of inside mains using 5 runs of 10 sq. mm [from MCB DB to switch boards and from switchboards to switch boards or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming to IS:694/1990 or latest duly inside the PVC conduit laid vide 16) b) below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site.b) Supply and Concealing of 40mm dia rigid PVC conduits [IVORY colour] along with suitable bends,Junction Boxes,clamps and all accessories and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note 1: - 5 runs of 10 sq. mm copper conductor and 1 m of 40mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,Junction Boxes,Clamps,Screws and other items required for successful concealing of 40mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer in charge at site is covered under contractors scope of work. | — | 2400.00 | — | — | |
| — | — | — | Above/ 3410880.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming to IS:694/1990 or latest duly inside the PVC conduit laid vide 17) b) below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site.b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] along with suitable bends,Junction Boxes,clamps and all accessories and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note 1: - 3 runs of 4 sq. mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,Junction Boxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer in charge at site is covered under contractors scope of work. | — | 16320.00 | — | — | |
| — | — | — | Above/ 729790.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3 runs of 2.5 sq. mm [from MCB DB to switch boards and from switchboards to switch boards or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables conforming to IS:694/1990 or latest duly inside the PVC conduit laid vide 18) b) below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site.b) Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] along with suitable bends,Junction Boxes,clamps and all accessories and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit]Note 1: - 3 runs of 2.5 sq. mm copper conductor and 1 m of 25mm dia PVC conduit pipe are taken as 1m for quantity purpose Note 2: Bends,Junction Boxes,Clamps,Screws and other items required for successful concealing of 25mm dia PVC conduit pipe at fixed intervals ,site conditions and as per directions of Section Engineer in charge at site is covered under contractors scope of work. | — | 4370.00 | — | — | |
| — | — | — | Above/ 15228.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Staircase point length above 10 mtr] by supply and drawing of 3 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- stranded copper cables of 1100 V grade[conforming to IS: 694/1990 or latest] along with a)Supply and Concealing of 25mm dia rigid PVC conduits[IVORY colour] conforming to IS:9537 Part 3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition/clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] b) Supply and provision of 6 A Modular type switch conforming to IS: 3854/1997 or latest, c)Supply and provision of 1 No. 3 plate ceiling rose conforming to IS:371/1999 or latest and with all standard accessories complete required as per site conditions and in a manner as directed by Section Engineer in charge at site. | — | 36.00 | — | — | |
| — | — | — | Above/ 62400.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Short point length upto 3 mtr] by supply and drawing of 3 runs of 1.5 sq.mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade[conforming to IS: 694/1990 or latest] along with a)Supply and Concealing of 25mm dia rigid PVC conduits[IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition/clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] b) Supply and provision of 6 A Modular type switch conforming to IS: 3854/1997 or latest, c)Supply and provision of 1 No. 3 plate ceiling rose conforming to IS:371/1999 or latest and with all standard accessories complete required as per site conditions and in a manner as directed by Section Engineer in charge at site. | — | 240.00 | — | — | |
| — | — | — | Above/ 423339.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Medium length between 3 mtr to 6 mtr] by supply and drawing of 3 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- stranded copper cables of 1100 V grade[conforming to IS: 694/1990 or latest] along with a)Supply and Concealing of 25mm dia rigid PVC conduits[IVORY colour] conforming to IS:9537 Part 3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition/clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] b) Supply and provision of 6 A Modular type switch conforming to IS: 3854/1997 or latest, c)Supply and provision of 1 No. 3 plate ceiling rose conforming to IS:371/1999 or latest and with all standard accessories complete required as per site conditions and in a manner as directed by Section Engineer in charge at site. | — | 1061.00 | — | — | |
| — | — | — | Above/ 15936.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 2 modules,switches, sockets, blank plates etc. duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc.complete and in a manner as directed by Senior Section Engineer in charge at site.Note: -2 module Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 192.00 | — | — | |
| — | — | — | Above/ 39600.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 6 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switchboard box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site.Note: -6 module Frame plate with matching cover plate,switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 240.00 | — | — | |
| — | — | — | Above/ 20679.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 8 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switchboard box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site.Note: -8 module Frame plate with matching cover plate,switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 113.00 | — | — | |
| — | — | — | Above/ 18240.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 4 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switchboard box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc. complete and in a manner as directed by Senior Section Engineer in charge at site.Note: -4 module Frame plate with matching cover plate,switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 192.00 | — | — | |
| — | — | — | Above/ 93296.00 Below/P | ||
| Installation, Testing and commissioning of metal junction box(switchboard of size 200mmx150mmx50mm fabricated with 16 gauge steel an provided with 3mm thick decolam sheet top, knockout, and recess mounting/concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete ,re- plastering ,painting etc., complete and in a manner as directed by Senior Section Engineer in charge at site.Note: - 200mmx150mmx50mm fabricated with 16 gauge steel metal junction box alone will be Supplied Departmentally. | — | 833.00 | — | — | |
| — | — | — | Above/ 18816.00 Below/P | ||
| Installation, Testing and commissioning of 1 feet 5WLED Batten light fitting suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper[White/Ivory colour]conductor flexible pendantchord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 1 feet 5W LED light fitting Batten type with lamp alone will be supplied Departmentally | — | 384.00 | — | — | |
| — | — | — | Above/ 37490.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 20W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 4 feet 20W LED light fitting Batten Type with lamp alone will be supplied Departmentally | — | 326.00 | — | — | |
| — | — | — | Above/ 2352.00 Below/P | ||
| Installation, Testing and commissioning of 5W Bulk head fitting suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting arrangement including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper[White/Ivory colour]conductor flexible pendant chord conforming to IS:694/1990 or latest in a manner as directed by Senior Section Engineer in charge at site.Note: 5W Bulk head fitting with lamp alone will be supplied Departmentally | — | 48.00 | — | — | |
| — | — | — | Above/ 31968.00 Below/P | ||
| Installation, Testing and commissioning of 1200mm sweep BLDC ceiling fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 1200mm sweep BLDC Ceiling fan alone will be supplied departmentally. | — | 144.00 | — | — | |
| — | — | — | Above/ 30240.00 Below/P | ||
| Installation, Testing and commissioning of the 300mm sweep BLDC Exhaust fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated,PVC round sheathed copper [White / Ivory colour]conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 300mm sweep BLDC Exhaust fan alone will be supplied departmentally. | — | 144.00 | — | — | |
| — | — | — | Above/ 13104.00 Below/P | ||
| Installation, Testing and Commissioning including concealing work along with metal clad plug and socket unit in sheet steel enclosure conforming to IS: 8623/1993 or latest complete as per industrial practices with 1 No. 25 A,DP, RCCB onto the walls including cutting/chipping and replastering and bringing back walls to original condition including painting in a manner as directed by section engineer in charge at site.Note: Metal clad plug and socket with Enclosure and RCCB alone will be supplied Departmentally. | — | 144.00 | — | — | |
| — | — | — | Above/ 11664.00 Below/P | ||
| Installation, Testing and Commissioning including concealing work along with metal clad plug and socket unit in sheet steel enclosure conforming to IS: 8623/1993 or latest complete as per industrial practices with 1 No. 20 A,SP, MCB onto the walls including cutting/chipping and replastering and bringing back walls to original condition including painting in a manner as directed by section engineer in charge at site.Note: Metal clad plug and socket with Enclosure and MCB alone will be supplied Departmentally. | — | 144.00 | — | — | |
| — | — | — | Above/ 2280.00 Below/P | ||
| Installation, Testing and commissioning of time switch assembly comprising of: -a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz].b)1 No. 3 pole 25A power contactor conforming to IS:13947/P4/1993 or latest,c)1 No. 40A DP [MCB type] isolator conforming to IS:13947/P3/1993 or latest,d)1 No. Neutral link etc.e)1 No. Earth link etc.f) Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well-seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site.Note: Timer switch, Power contactor, MCB, Neutral Link,Earth link, fuses, wooden box, Enclosures alone will be supplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 2325.00 Below/P | ||
| Installation, Testing and commissioning of 45 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated,PVC round sheathed copper [White/Ivory colour]conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site.Note: 45W LED street light fittings alone will be supplied departmentally. | — | 15.00 | — | — | |
| — | — | — | Above/ 256.00 Below/P | ||
| Installation, Testing and commissioning of SMC box assembly similar to Sintex Catalogue reference No.GSJB- 3020 along with strip connector block, Neutral link, fuse bases and carriers onto lamp posts or elsewhere suing suitable clamping arrangements complete and in a manner as directed by Section Engineer in charge at site Note: SMC GSJB-3020 box, strip connector, neutral link, Earth link,Fuse bases and fuse carriers, MS clamping arrangements alone will be supplied Departmentally. | — | 2.00 | — | — | |
| — | — | — | Above/ 8904.00 Below/P | ||
| Erection, Testing and commissioning of 2 HP energy efficient five star submersible pump set including control panel , suitable for 200 dia BORE WELL and suitable for operation on three phase AC supply complete along with all accessories including fixing and mounting arrangements complete as per industrial standards and in a manner as directed by Section engineer in charge at site.Note:2 HP BORE WELL Submersible pump with Control panel assembly alone will be supplied Departmentally | — | 4.00 | — | — | |
| — | — | — | Above/ 12603.00 Below/P | ||
| Erection, Testing and commissioning of 7.5 HP energy efficient five star submersible pump set including control panel , suitable for 200 dia OPEN WELL and suitable for operation on three phase AC supply complete along with all accessories including fixing and mounting arrangements and other items required for successful commissioning of pump complete as per site conditions and as per industrial standards in a manner as directed by Section engineer in charge at site.Note:7.5 HP OPEN WELL Submersible pump with Control panel assembly alone will be supplied Departmentally | — | 3.00 | — | — | |
| — | — | — | Above/ 4000.00 Below/P | ||
| Laying/Leading of 3 core 4 sq. mm PVC insulated copper conductor flat submersible cable including waterproofing terminations ,joints and connecting upto panels in a manner as directed by Section Engineer in charge at site Note: 3 core 4 sq.mm PVC Cable alone will be supplied Departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 257125.00 Below/P | ||
| Supply and provision of 1½inch dia. heavy-duty [C class]GI pipe confirming to IS:1239 P1/2004, P2/1992 or latest to act as riser pipe for the above submersible pump sets complete in a manner as directed by Section Engineer in charge at site. Note: The riser pipe shall be in short sections (in lengths of 3.0 meter) to facilitate erection and dismantlement. | — | 605.00 | — | — | |
| — | — | — | Above/ 37600.00 Below/P | ||
| Supply and provision of intermediate heavy-duty long couplers in a manner as directed by Section Engineer in charge at site. | — | 200.00 | — | — | |
| — | — | — | Above/ 3206.00 Below/P | ||
| Supply and provision of 1½inch dia. medium-duty[B class] GI bend confirming to IS: 1239 P1/2004,P2/1992 or latest in a manner as directed by Section Engineer in charge at site. | — | 14.00 | — | — | |
| — | — | — | Above/ 7441.00 Below/P | ||
| Supply and provision of 1½inch Gunmetal Gate valve confirming to IS: 778/1984 or latest in a manner as directed by Section Engineer in charge at site. | — | 7.00 | — | — | |
| — | — | — | Above/ 14000.00 Below/P | ||
| Supply and provision of 1 ½inch dia Gunmetal Non-return valve confirming to IS:5312/P1/2004, P2/1986 or latest including supply and provision 2 inch X ¼ inch MS clamp for supporting the riser pipe complete in a manner as directed by Section Engineer in charge at site. | — | 7.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TechnicalSpecifications.pdf
ATTACHMENT
Tenderschedulequantitybreakup.pdf
ATTACHMENT
Checklist.pdf
ATTACHMENT
GCCandACS1-12.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
IdentityCardsamplewithguidelines.pdf
ATTACHMENT
ImportantinstructionstoTenderersabove50LAfterGCCACS12.pdf
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fansasper2026.pdf
ATTACHMENT
Special_conditions_of_Contract_Electrical.pdf
ATTACHMENT
StandardGuaranteecertificateformat.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .