Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹52.9 L+₹1.2 L (2.32%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹56.0 L+₹4.2 L (8.15%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹57.6 L+₹5.9 L (11.3%)Rejected-Finance 12 2 332 21 HILL COLONY OPP SUNRISE SCHOOL MEHDIPATNAM HYDERABAD 500028 | HYDERABAD | HYDERABAD | TELANGANA | 500028 | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹58.7 L+₹7.0 L (13.5%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L5 | Rejected-Finance Not L1 |
Tender Value
₹55.6 L
EMD Value
₹1.1 L
Closing Date
1 Feb 2021, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
SPECIAL REPAIRS TO OTM ACCN BLDG NO. E-01 AT HAIG LINE OF 4 TRG BN 1 EME CENTRE UNDER GE(NORTH) SECUNDERABAD
2020_MES_407427_1
CWE(S)/NORTH/TOKEN-31 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹1,000
GE(North) Secunderabad
₹1.1 L
Yes
1 Apr 2021
28 Dec 2020
4 Feb 2021
28 Dec 2020
1 Feb 2021
19 Jan 2021
Amount
Dismantling of Single layer Mangalore pattern tiles in roofing complete all as specified and directed.
Dismantling of tile batten spacing exc 15 cm from roof complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including similar pattern roof covering complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame work complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ridge to wall fixed with self tapping screws complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Joist channel, angle or tee sections, fixed independently without connecting plates, etc., ( cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W ( Gde-E-250) quality A : Note: The ISMB's have to be inserted in wall by replacing damaged existing rafters as in old madras terrace roof including necessary precautionary measures as in supports etc., as directed by the engr-in charge.
S&F Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk)forming holes, without anyattachment etc.roof strusses (framed) and connecting plates, etc., including necessary precautionary measures as in supports etc., as directed by the engr-in charge.
S&F Mild steel bolts purpose made with hexagonal or forming holes, without any attachment dia of neck exc 20mm not exc 25mm complete all as specified and directed.
M&L preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S & F E Grid suspended false ceiling grid system of size 600 x 600mm with main runner 39x29.7x0.60mm cross tee 29x24.7x0.60mm and wall angle 22.2x22.2x0.50mm ceiling suspended with 2 to 2.5 mm dia GI wire hanger fixed to purlin / truss etc complete (Main runner, cross tee, wall angle of MS galvanised with PPCGS) over the grid providing 4mm thick HPSC pre primed self designer texture non asbestos fibre cement building board fixed to frames etc complete all as specified and as directed by Engr-In-Charge.
Dismantling timber scantling 40 Sqcm & over in section in any position in unframed work complete all as specified and directed
Fixing only timber scantling in roofs complete all as specified and directed. Note: Material obtained from item No.13 above for reuse
M&L for Second class hard wood scantlings clean sawn and fixed with nails/srews complete all as specified and as directed.
M & L for preparation of old wooden rafter surfaces and applying one coat of creosite oil complete all as specified and directed.
M& L for preparation of new wooden rafter surfaces and applying two coats of creosite oil complete all as specified and directed.
Demolition of Plain Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for rendering 15mm thick on concrete or fairfaces of brick work in CM 1:3, finished even and smooth without using extra cement but mixing WPC complete,all as directed and as specified Note:- WPC shall be measured and paid separately
Supply only integral water proofing compound.
M&L for PCC 1:5;10 type E2 using 40mm size graded stone aggregate for filling and mass concrete in sunken floors complete all as specified and directed.
M & L for perperation of surface by sweeping with wire brushes and cleaning surface from dust , dirt and projections and providing water proofing treatment with APP based polymeric membrane minimum weight 3.0 KG/sqm and minmum 3mm thickness reinforced with Polyester non woven fabric (weight not less than 150gm/sqm) as per IS 3384 applied on one coat of oil based bitumen emulsion primer @ .3 ltr /Sqm by forced application with 10cm over laps and applying a coat of blown bitumen 85/25 @ 1.2 Kg/sqm on top of membrane and providing 25mm thick sand cousion to receive lean concrere complete all as directed and as specified
Demolition of brick work or stone / boulder masonry, built in cement or lime mortar including all quoints, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in cement mortar 1:6 complete all as specified and directed
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in cement mortar 1:4 complete all as specified and directed
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar etc complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in base course to receive floor finishes complete all as specified and directed.
M&L 10mm thick rendering as in backing coat on fair faces of brick work or concrete surface with CM 1:4 complete all as specified and directed.
M&L 20-25 mm thick machine cut Polished kota stone as in flooring laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over bedding layer of 15mm thick in CM 1:6 complete all as specified and directed.
M&L 20-25 mm thick machine cut Polished kota stone as in treads of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over bedding layer of 15mm thick in CM 1:6 complete all as specified and directed.
M&L 20-25 mm thick machine cut Polished kota stone as in skirting / riser of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.
Taking down shutters of any discription not exc 1.0 sqm each complete all as directed
Taking down shutters of any discription not exc 1.0 sqm each and refixing in the same opening complete all as directed
Taking down shutters of any discription exc 1.0 sqm but n exc 2.0 sqm each complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhats with shutters (with out taking off shutters from the frames) not exc 1.5 sqm each complete all as directed and refixing in the same opening, complete all as directed.
Taking down chowkhats with shutters (with out taking off shutters from the frames) exc 1.5 sqm & not exc 4.00 sqm each complete all as directed
Supply and fix steel windows made with galvanised steel colour coated/powder coated (Base steel as per IS 513 'D' galavanised as per 277 with zinc of (120 grams/squaremetre) with total coating thickness of 0.60mm, sections for frame should be of 72 mm x 55mm, section for mullian should be 72mm x 50mm section for shutter frame should be 47mm x 20 mm, and section for fixing glass beead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 6mm, stainless steel wire mesh of 0.30 mm dia and average width of aperture 1.40mm shall be used for fly proofing, 4mm thick plain sheet glass to be used for glazing of glazing of glazed shutters complete with saftey grills etc.,all as specified and as directed Make NCL Alltech or equivalent make as mention at makes list in PS
S & F second class hard wood plain, solid straight chowkats and frame, wrought, framed rebated on the solid, rounded or chamfered, put together with glue and pinned at joints complete all as specified and directed.
M&L Preparation of wood surface, treating the back of chowkhat, end of post etc area tarred exceeding 0.1 Sqm but not exc 0.5 sqm each complete all as specified and as directed.
M&L Treating small articles such as hold fasts, ends of posts, backs of chowkats etc area n.exc .10Sqm each complete all as specified and as directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for largegates; hook and pintle hinges:large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for securing purlins to wood trusses or rafters; knee pieceinserts; two way and three way straps, plate washers and similar small articles conforming toFe-290 Gde-E-165 complete all as specified and as directed.
S & F 3mm thick sheet glass, ordinary quality, glazing with oil putty in square panes, not exc, 0.50 sqm each pane complete all as apecified and directed
S&F in repairs Stainles steel wire cloth ,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, or galvanized wire staples complete all as specified and directed.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face pannels, commercial type on both sides complete all as specified and directed.
M&L 35mm thick 2nd class hard wood, glazed and skelton shutters for doors , open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc ; sizes of members of shutters as specified in SSR Part-I, Section 8 clause 8.24 (a) complete all as specified and directed.
S&F Stainles steel wire cloth ,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , or galvanised wire staples complete all as specified and directed.
S & F 100mm butt hinges medium weight cold rolled mild steel.all as specified and directed.
S & F 200mm long MS barrel tower bolt stove enamelled black with brigh bolt complete all as specified and as directed.
S & F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L 10mm th rendering in CM (1:3) on ceiling finishing the surfece even and smooth with out using extra cement complete all as specified and directed.
M & L Rendering other than fair faces15 mm thick in CM 1:4 with water proofing compound finished even and smooth with out using extra cement complete all as specified and directed.
M & L Rendering 15 mm thick in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L Non - skid colured ceramic tiles 7 to8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of 15mm thick in cm 1:6 complete all as specified and as directed .
M & L non skid coloured ceramic joint free tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in coloured cement to match including screed bed or bedding layer in CM 1:6 ,15mm thick for flooring complete all as specified and directed.
M & L glazed ceramic coloured tiles (450X300mm)x 7mm thick in dado/skirting set and jointed in neat cement slurry and pointed in coloured cement to match over backing coat of CM , 1:4 , 10mm thick backing coat complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 3mm thick wall putty etc., complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer etc., complete all as specified and directed.
supply & fix in repair vitreous China squatting pan ‘Orissa’ pattern, size 580 X 440 mm white, integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe, PCC 1:3:6 type C2 bedding etc, complete including making good to floor to match with adjoining surfaces complete all as specified and directed.
S &F in repairs of 75 mm dia PVC (SWR) Floor trap Trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as directed
Taking down soil, waste and rain water pipes (any size or pattern) including all fittings, heads, shoes. Bends, swan-necks etc., including cleaning or refixing or removal to store complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
Supply & fixing 110 mm bore PVC (SWR) double 'T' equal or un equal bends with acess door complete all as specified.
Supply & fixing PVC (SWR) 110mm bore junction ( Double 'Y" equal or unequal with access door complete all as specified
S & F in repairs bib tap cast copper alloy with crutch or butterfly handle screwed down for iron pipes or brass ferrule of size 15 mm bore (minimum weight 90 grams) complete all as specified and directed.
S & F in repairs stop valves cast copper alloy with crutch or butterfly handle screwed down for iron pipes or brass ferrule of size 15mm bore (Minimum weight 90 grams) complete all as specified and directed.
S&F in repairs 15 mm bore chromium plated shower rose with or without swivel joint ixing with 15mm pipe complete all as specified and directed.
S & F in repair PVC valveless syphonic action type low level flushing cistern 10 Ltr capacity with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia all as specified and directed
S & F in repairs chromium plated tubler towel rail 20 mm dia D type 60 cm long between flanges of aluminium anodised complete all as specified and directed.
S & F in repairs Vitreous china white urinal bowl flat back of size 465x355x265mm fixed to walls with 40mm waste coupling and waste pipe complete all as specified and as directed
M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of alkali resistant primer and 3mm thick putty on walls etc.,complete all as specified and directed.
M&L Complete removal of existing treatment on walls and applying 2 coats of apex ultima weather proof paint over a coat of apex ultima primer including preparation of surface complete all as specified and directed.
M&L Preparing the old decorated plastered/un plastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L Preparation of old painted wooden surfaces over 10 cm width or girth and applying a coat of synthetic enamel paint complete all as specified and directed.
M&L Preparation of old painted steel surfaces over 10 cm width or girth and applying a coat of synthetic enamel paint complete all as specified and directed.
Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M S square tubes, S&F in opening as per specification & drawing given in SSR-2004 complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings given in Section 8 of MES Schedule Part-II 2004 as applicable complete all as directed & specified
S & F 150mm long aluminium handles, cast type anodised extruded section and fixed complete all as specified and directed.
S & F aluminium anodized barrel tower bolt of extruded section of size 150 mm long complete all as specified and directed.
M & L for Butt hinges of size 100 mm long extruded aluminium alloy with galvanised mild steel hinge pin of type C-21 complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing complete all as specified and as directed
All as per item No.87 above but on 20mm dia complete all as specified and as directed
All as per item No.87 above but on 40mm dia complete all as specified and as directed
Refixing old steel tubing of 15 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and as directed
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and as directed
Refixing old steel tubing of 40 or 50 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and as directed
S & F 15 mm bore conceled galvanized steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors including making good the cutting area in cm 1:3 complete all as specified and as directed
S & F 15 mm bore galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed
S & F 40 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as complete all as specified and as directed
Material and labour for providing hardcore of broken stone of gauge not exc. 63 mm deposited, spread and leveled in layers not exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed
Taking down removal of existing roof treatment of any type any thickness and remove the same from work site to yard complete all as specified and as directed
M&L for PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) for leveling of roof surface complete all as specified and directed.
M&L Apply evenly a tack coat with hot blown bitumen 85/25 grade at 1.20 Kg/Sq.M over bitumen primer @ 0.50 Lit/ Sq.M ,APP based polymeric membrane minimum weight at 3.00 Kg/Sq.M and a minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/Sq.M) shall be laid over tack coat on roof and on vertical surface upto and insert in grooves and packed in CM(1:3) with overlaps in members 100 mm .The over laps shall be sealed by flames or as per manufacturers instructions .A coat of hot blown bitumen at 1.20 Kg/Sq.M shall be applied over water proofing membrane and Bituminous aluminium paint @ 0.50 Lit/Sq.M all as specified and directed for non accessible works
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness (below & above ground level) completed all as specified and directed.
M & L 75mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for rubber moulded polished chequerred cement concrete tiles with mixture of grey and white cement in equal proportions and no pigments of size 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed of 15mm thick in CM 1:6 complete all as specified and as directed
S & F in repair 40 mm Gun-metal globe or gate valve with iron wheel head, scewed both ends for iron pipe complete all as specified and as directed
S&F in repair rotational moulded polyethylene water storage tanks 2000 ltrs(cylindlerical vertical with closed top) hoisted and fixed in position all as specified in SSR part I inclding dismantaling of existing damaged water tanks. all as specified and as directed.
M&L in repairs ball valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe 40mm bore & fixed.(Minimum weight 210gms ) complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2, as in surface channels and drains (using 40mm graded aggregate) complete all as specified and as directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and as directed by Engr-In-Charge.
Excavation in trenches n.exe 1.5m wide and not exe 1.5m deep for laying of drainpipes, laying cable in trenches etc or for manhole, etc., not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each in soils all as specified and as directed.
Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for PCC 1:4:8 type D2 using 40mm size graded stone aggregate for filling and mass concrete in foundation complete all as specified and directed.
M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in landings, cover slabs (for manhole etc) including necessary form work and set in CM (1:6) complete all as specified and directed. Note:- reinforcement shall be measured and paid separate under respective items
S & F MS steel TMT bar 8mm to 10mm dia and over cut to length bent to shape required including cranking, bending spiraly for hooping for column hooking ends and binding with and including mild steel wire (annealed 0 not less than 0.9mm dia or securing with clip, complete all as specified & directed.
Demolition and breaking up drain pipes NP3 (salt glazed ware AC or reinforced concrete) set in cement mortor 150mm dia complete all as specified and as directed.
Demolition and breaking up drain pipes NP3 (salt glazed ware AC or reinforced concrete) set in cement mortor 200 mm dia complete all as specified and as directed.
S & F salt glazed stoneware drain pipe (SGW) grade 'A' laid in trenches and jointed as specified of internal dia of pipe 150mm all as specified and as directed.
M&L for reinforced concrete pipes, class NP3 150 mm bore laid in trenches with one collar per length and jointed with cement joints complete all as specified and as directed.
M&L for Concrete bed with cement concrete 1:4:8 type D2 using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 150 mm bore complete all as specified and as directed.
Material and labour for reinforced concrete pipes, class NP3 200 mm bore laid in trenches with one collar per length and jointed with cement joints complete all as specified and as directed.
M&L for Concrete bed with cement concrete 1:4:8 type D2 using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 200 mm bore complete all as specified and as directed.
Cutting into existing manholes for connecting new drain, making good to pipe and rendering, cutting out existing benching for end forming brranch channel (1/2 round or 3/4 section) in cement conrete 1:2:4 type B1 smoth finished and reforming benching as required for 150 mm internal dia of pipe all as specified and as directed..
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/ power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified
M&L for point wiring on concealed conduit complete all as specified with 1100 Volts grade 1.5 sqmm PVC with multistranded copper conducter conforming to IS:694:1990 with ISI markking ( For Phase, Neutral and Earth) in and including non metallic PVC rigid coundit medium grade with ISI mark of size 20 mm dia with all accessories concealed in wall/ceiling/floor/roof etc, for fixing modular switches, sockets, fan regulators etc of suitable modules and earth wire to be connected to commom earth dolly/pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/ grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up to 1.5 Sq mm copper conducter PVc insulated cable as earth continuiy conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ requlators etc all as soecified for and directed foe the followig :-
(a) One light/bell point controlled by one, one way switch 5A, SP
(b) One ceiling / exhaust fan point controlled by one, one way switch and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the independent board
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board
Description all as per item No. 135 here-in-above but using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running 2.50 Sqmm copper conductor PVC insulated cable earth continuity conductor all as specified and as directed.
Supply and fix switch piano, single pole one way, flush type, 5 Amps 230 volts for light, fan and tube light complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, multipurpose 3/5 pin of 5 amps, flush type complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, multipurpose 6 pin of 15 amps, flush type complete all as specified and as directed.
Supply and fix fan regulator, 5 stepped, electronic type, single phase, socket size complete all as specified and as directed.
Supply and fix Lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and as directed.
Supply and fix Ceiling rose of surface Bakelite 65 X 50 mm, three terminals, AC 50 HZ, 230 Volts complete all as specified and as directed.
Supply and fix wall mounted indus plus LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with necessary mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W including taking down existing unserviceable tube light fitting complete all as specified and as directed. Make : C&S cat No - LTIC00120WLED/WD, Havells cat No-REGALBATTENT8UPTO1X22WSSBSWH incl Tube Rod cat No-PHOTONULTRA2.01213T8SSTL20WLED865SPC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE.or equivalent make as given at list of makes in PS
Supply anf fix in replacement LED security light luminaire fitting of 1x25 watts with deep drawn housing including all accessories and LED lamp 25W with suitable 40 mm dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as sepcified and as directed. Make - C&S Cat No - LTESSE25WLED, Havells CAt No - ENDURAPEARLSL25WLED757SASYTOPCMP, Wipro Cat No LLR06-311-XXX-57-XX or equivalent make as given at list of makes in PS
Supply and fix sheet metal enclosure MCB DB SPN 8 Way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed. Make : Havells - CAT Part No DHDPSHODRWO8, Standard Cat No - DSDCSHODOW08, C&S Cat No - CSDBSPNPDD08 or equivalent make as given at list of makes in PS
Supply and fix MCB SPN 40 amps 240 volts 'C' curve suitable for fixing in MCB DB including taking down existing old unserviceable MCB complete all as specified and as directed. Make : Havells Cat No DHMGCSNF040, Standard Cat No - DSMGCNF040, C&S Cat No - CSMBS1C40N or equivalent make as given at list of makes in PS
Supply and fix MCB SP 6 to 32 amps 240 volts 'C' curve suitable for fixing in MCB DB including taking down existing old unserviceable MCB complete all as specified and as directed. Make : Havells - Cat No DHMGCSPF006-032, Standard Cat No - DSMGCSPF006-032, C&S Cat No - CSMBS1C6-32 or equivalent make as given at list of makes in PS
Material and labour for sub main wiring with two runs of single core FRLS PVC insulated, multistranded unsheathed copper conductor cable of size 4 square mm and drawing through PVC conduit of 20mm dia with accessories on surface in wall/roof along with one run of 4 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board duly making good the disturbed wall surfaces to match with the surroundings including taking down of existing wiring complete all as specified and directed. Note:2 runs of 4 sq mm cable, one run of 4 sq mm earth continuity conductor and one run of conduit shall be measured as one unit length
Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
Disconnecting and removing ceiling fan of 1200/1400 mm sweep from any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified. Note :- 1. PVC 2 Core copper cable multstandrad of size 0.50 Sqmm from ceiling rose to ceiling fan deemed to be included in the rate quoted by the contractor 2. supply of unserviceable parts for replacement shall be measured and paid seperately in respective items.
Supply only fan condenser of capacity 2.00/2.50 Mfd complete all as specified and as directed.
Supply only Sealed ball bearing suitable for ceiling fan of any size
Supply only Rubber bushes with 'U' type MS clamp, bolt, nut and split pins of heavy duty suitable to existing fan complete all as specified and as directed .
Supply only Mild steel rod for ceiling fans of 3ft long duly screwed threads with check nuts & pin for ceiling fan complete all as specified and as directed
Supply only Nut and bolts washers for fan blades fixing of ceiling fan of any make/size/type (6 Nos for each set) complete all as specified and as directed .
Supply and fixing exhaust fan 300 mm (15 “ sweep) AC, 230 volts, metal body, including making hole arrangement in the wall, finishing the surface, grouting the bolts for fixing the frame of exhaust fan incl replastering the uneven and internal surface of hole including taking down old unserviceable exhaust fan and deposit to MES store yard complete all as specified and directed.
S&F Vertical type TPN distribution board of 4 way double door with and including incoming MCCB FP 415 V AC, 3 phase, 50 Hz, 10KA breaking capacity with fixed magnetic setting for current ranging of capacity 63 Amps confirming to IS 13947 (P-2) IEC 947 made out of CRCA sheet housing with powder coated confirming to IS 13032 IS 8623, BS 5486 accomadated suitably in a mild steel enclosure weather proof having hinged and robust locking arragement complete all as specified and directed DB Make: Havells cat No- DHDLVDRWGOFO04 or equivalent inC&S / Schnider / Legrand / Standard or equivalent make as given at list of makes in PS MCCB make : Hevalls cat part No. 1HLGSF0063 or equivalent inC&S / Schnider / Legrand / Standard or equivalent make as given at list of makes in PS
Dismantling steel pole/structs of any height by taking out from PCC foundation complete and shifting to other location as directed
Dismantling and taking out worn out / unsv existing insulator of any type complete all as directed.
Dismantling and taking out worn out ACSR conductor from overhead electric line complete all as directed .
S&F Weather proof outdoor bus bar chamber made out of 3mm thick MS sheet comprising 4 Nos aluminium strips each of 300 Amps, 60 cms long duly insulated mounted on insulators including MCCB four pole, 200 Amps, 415 Volts with 4 Nos mounting legs made out of 25mm x25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm ( 30cm depth below gound level and 60 cm above ground level) in cement concrete 1:3:6, type C2 (using 40mm grade crushed stone aggregates) and conncections with suitable size of aluminium thimbles, nuts, bolts & washers, cable glands at entry and outlet points and excavation, earth work, returning filling in and removing of surplus soils complete all as specified and directed.
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
Supply, laying, fixing on wall/on pole/in ground or passing through pipe, 1100 Volts grade heavy duty cable with XLPE insulation stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 70 sq mm nominal cross section including jointing and testing complete all as directed . Note: Excavation, earth work, GI Protection Pipe, PCC covers & sand shall be measured and paid separately under respective items.
Supply, laying, fixing on wall/on pole/in ground or passing through pipe, 1100 Volts grade heavy duty cable with XLPE insulation stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 95 sq mm nominal cross section including jointing and testing complete all as directed . Note: Excavation, earth work, GI Protection Pipe, PCC covers & sand shall be measured and paid separately under respective items.
Supply, spread river sand of approval in cable trenches providing for cable cushioning to the full width jof excavated trench 8cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and tesing of cable on transforer yard etc compete all as specfied and directed. NOTE: Punned thickness of sand only will be measured and paid.
S& Lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm all as specified and as directed.
S& Lay 50 mm dia GI tubing light grade in protection of cable at roads crossing/hard standing/pole protection fixed with MS clamps of size 40x4mm nut bolts and washer as per site requirement etc all as specified and directed .
A SOMA RAJU
M/s GM Constructions
rahi consultant
Mavee Syndicate
SHAH ENTERPRISES
PAVAN ENTERPRISES
SAI RUPA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .