| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹23.6 L+₹14,344.16 (0.61%)Rejected-Finance 283 ALIEN MARKET SADAR KABARI BAZAR MEERUT CANTT UP | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹26.3 L+₹2.9 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹26.3 L+₹2.9 L (12.2%)Rejected-Finance 194A LUKER GANJ ALLAHABAD UP | ALLAHABAD | ALLAHABAD | UP | 211001 | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹30.7 L+₹7.3 L (31.0%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance Rejected due to not being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Jan 2024, 6:00 pmClosed
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt The Mall Road Meerut Cantt Distt Meerut-250001(UP)
COMPREHENSIVE MAINT/REPAIR OF INTERNAL WIRING AND CONNECTED ITEMS IN SHIVAJI LINE AND GF ROAD UNDER AGE E/M-II OF GE (SOUTH MEERUT CANTT
2023_MES_631600_1
GE/MRT/S/8102/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MEERUT CANTT
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
Yes
GE (South) Meerut
₹98,000
Yes
25 Jan 2024
7 Dec 2023
6 Jan 2024
7 Dec 2023
4 Jan 2024
21 Dec 2023
Amount
Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site to store making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable FRLS in and including PVC concealed conduit of not less than 20 mm dia or higher medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washer etc, sunk zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated solid copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One Tube light/bulb/fancy light/street light/ Bell point controlled by one, one way switch 05 / 06 Amps.
All as per item No 2.00 here-in-before but for One ceiling fan/exhaust point controlled by one, one way switch 05 / 06 Amps.
All as per item No 2.00 here-in-before but for One two way point controlled by two, two way switches 05 / 06 Amps.
All as per item No 2.00 here-in-before but for One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch.
All as per item No 2.00 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable FRLS for one 5 / 6 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch.
All as per item No 2.00 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable FRLS for one 15 / 16 Amps socket outlet point on independent board controlled by one, oneway 15/16 Amp switch.
M&L switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
Supply & fixing socket outlet 2 in 1, 3 pin, 05 / 06 Amps flush type 240 volts complete all as specified and directed.
Supply & fixing switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified and directed.
Supply & fixing of socket outlet 2 in 1, 3 pin, 05 / 06 Amps and 15 / 16 Amps, flush type, 240 volts complete all as specified and directed.
Supply & fixing switch piano flush type, 05/06 Amps single pole, two way 240 volts complete all as specified and directed.
Supply and fixing steped type electronic fan regulator flush type AC, 230 volts complete all as specified and directed.
S&F in repair bell push flush type , 5 amps , 240 volts complete all as specified and directed.
S&F in repair Bell AC, 230 volts single pole complete all as specified and directed.
S&F in repair lamp holder (Angular / Straight), PCV/Polycarbonate insulated body, with back plate for batten fitting complete all as specified and directed.
S&F in repair Decorative wall light fixture made up of Polycarbonate, suitable for 9/10 W LED lamp B22 base including 9/10 W LED lamp and including all accessories for fixing of fitting on wall complete all as specified and directed.
S&F in repair LED lamp 9/10 watts, CDL, with Star rating complete all as specified and directed.
S&F in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair Integrated wall mounted LED tube light fitting 20 watt with polycarbonate housing and integrated electronic driver with all accessories and fixing material complete all as specified and directed.
S&F in repair LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including provisson of 32 mm bore light grade GI tube mounting bracket 0.6 m long made to shape bend to 100 to 120 degree and fixed to wall by means of flat iron clamps and suitable nuts, bolts grouted in wall etc and provision of weather proof PVC insulated copper conductor cable 2.5 Sqmm 2 core as required for connection complete all as specified and directed.
S&F in repair of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor FRLS cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all PVC conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing including taking down old unserviceable submain wiring of any size & type complete all as specified & directed. Note:-One meter of rigid non-metallic PVC conduit along with two runs of 06mm wire and one run of 06 sqmm earth wire shall be measured and paid as one unit length.
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection with metal door , including MCCB 4 Pole 100 Amps 16 KA, 415 volts , 50 Hz with adjustable thermal & magnetic release and 12 Nos MCB's inside of DB for outgoing, and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing surface including taking down old unserviceable one complete all as specified and directed.
Supply, laying, testing & commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core laid in trenches, fixing on wall/under road crossing through protection pipe etc complete including taking out old unserviceable LT cable any type or size complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft / loose soil and gating out in soft / loose soil complete all as specified and directed.
Material and labour for sand cushioning with dry fine sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading, levelling and hand punning in layers in cable trench for protection of under ground cable complete all as specified and directed.
Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
Supply / laying and fixing 50 mm bore galvanised steel tubes with all fittings, light grade, laid in trenches/wall/pole for cable protection complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft / loose soil complete all as specified and directed.
Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed.
Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 32 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as specified and directed.
S&F in repair Sheet metal enclosure for DB's double door 240 Volt with IP 43 protection 200 amp rated insulated bus bar, shrouded neutral bar, earth bar, blanking plate, cable ties SPN 12 way complete all as specified and directed.
S&F in repair MCB SP, AC, 240 volts of 06 to 32 Amps, B curve, 10 kA. complete all as specified and directed.
S&F in repair MCB SPN, AC, 240 volts of 40 to 63 Amps, B curve, 10 kA. complete all as specified and directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI strip 32x6mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s/ Machinery etc including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed. Note:- (i) The cost of earth electrode, main earthing lead (from earth electrode to test point) up to 7.5 metre, connecting earth electrode & earthing lead as specified and adequate quantity of charcoal, dust, common salt shall be included in this item. (ii) Earth electrode beyond 7.5 metre shall be measured and paid separetely.
vibha associates
M/S ABHI ASSOCIATES
Manish Enterprises
Shikha Enterprises
K S Enterprises
SIDDHARTH TRADERS
Haryana EngineerService
m/s sweta trading co.
NITHYA INFRATECH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .