Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹28.7 L+₹56,870 (2.02%)Rejected-Finance | L2 | Rejected-Finance HIGHER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Nov 2023, 6:00 pmClosed
GE Amritsar
GE Amritsar pin 143001
REPAIR / MAINTENANCE OF GEYSERS AND SOLAR WATER HEATERS AT OLD AMRITSAR CANTT
2023_MES_623393_1
GE/ASR-62/2023-24
Open Tender
Civil Works
Works
180 days
GE Amritsar
class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹70,000
18 Sept 2024
16 Oct 2023
14 Nov 2023
16 Oct 2023
13 Nov 2023
30 Oct 2023
Amount
Geyser Material and labour for maintence of storage type electric water heater geyser capacity 25/35/50 litre comprising of the following activities:- (a) Inspection taking down, opening, dismantling , descaling, replacing unserviceable items brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling and refixing in position (b) Check and connect earth continuity of electric items (c) checking and adjustment of pressure release valves (d) Cleaning and maintainance and refix thermostat and its functioning (e) Checking of dead weight, cleaning and seal and ensuring that vent hole is not fuctioning (f) Visual examination of fuseibie plug ((g) Testing of geyser after repair Note:- The items requires replacement will be measured and paid seapartely under relevant items as supply only
Supply only heating element of geyser ISI Marked any type (Triangular/Rond cup , square etc. as per sample) 2 KW Capacity of INCOLOY material (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate) Make:- Racold/theeta/ Havells ; Complete all as specified and directed by Engineer-in-charge.
Supply only heating element of geyser ISI Marked any type (Triangular/Rond cup, square etc as per sample.) 1.5 KW Capacity of INCOLOY material (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate) Make:- Racold/theeta/ Havells ; Complete all as specified and directed by Engineer-in-charge.
Supply only thermostat as per sample ISI marked for geyser any capacity all as specified and directed Make:- Usha/Racold/Envy or equivalent ISI Marked ; Complete all as specified and directed by Engineer-in-charge.
Supply only thermal cut out as per sample ISI marked for geyser any capacity complete all as specified and directed Make:- Havells/Racold/Usha or equivalent ISI Marked ; Complete all as specified and directed by Engineer-in-charge.
Supply only indicator lamp as per sample to geyser of any size and shape ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of GI hexa nipple (set of two) of size 15 mm having screwed both ends with fine thread ; Complete all as specified and directed by Engineer-in-charge.
Supply only inner shell as per sample of suitable size made of stainless steel sheet of Fe 305 22 SWG ISI Marked can bear pressuure upto 0.8 MPa suitable for geyser of any type/Make and 25/35 litres capacity complete with all suitable accessories such as thermal insulation etc ; Complete all as specified and directed by Engineer-in-charge.
Supply only inner shell as per sample of suitable size made of stainless steel sheet of Fe 305 22 SWG ISI Marked can bear pressuure upto 0.8MPa suitable for geyser of any type/Make and 50 litres capacity complete with all suitable accessories such as thermal insulation etc c; Complete all as specified and directed by Engineer-in-charge.
Supply only inner base assembly as per sample complete with inlet ,outlet, thermostat pipes with drain plug and screw including clamps for holding the elements, nuts, bolt ,washer etc, ISI Marked for geyser of any type/Make and 25/35/50 litres capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of copper wire, 3 core, flexible type of size 2.5 sqmm etc complete all as specified and directed by the Engineer-in-Charge. Make : Havells/L&T/Finolex / Polycab
Supply only bottom cover plate (two halves) and fix with new bottom cover plate with matching colour of geysers of any type/Make and capacity ; Complete all as specified and directed by Engineer-in-charge.
Taking down existing unserviceable Non return valve and supply and dixing in poisition with new multifunction valve(NRV) ISI marked made of cast copper alloy screwed both ends internally suitable for iron pipe of size 15mm ; Complete all as specified and directed by Engineer-in-charge.
Supply only safety pressure valve with vent to geyser as per latest ISI specification ; Complete all as specified and directed by Engineer-in-charge.
Material and labour for PVC connection suitable for hot water of size 15 mm x 600 mm long superior quality for geyser complete with brass adopter for geyser of any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only of neoprene seal (bottom ring)for 25/35/50 ltr capacity geyser of superior quality ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for painting the outer surface of geysers of 25/35/50 itrs as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc and refixing the geyser in position including water/electric connection and testing, ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Brazing / welding of inner tank at leaking spots up to five leakage of geyser of capacity 25/35/50 ltrs of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed by Engineer - in - charge.
Supply and fixing in replacement of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure, ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of sheet metal enclosure (industrial type DB) complete in 2P+E configuration with plug and socket complete with one MCB SP B Curve type of capacity 20 Amp 10 KA ; Complete all as specified and directed by Engineer-in-charge. Make: Legrand/Indoasian/siemens
Material and labour for grouting of nuts & Tee bolts as directed for fixing of 50/35/25 Itrs capacity geyser including cement work and colour matching on existing wall ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement of 3 pin socket suitable for sheet metal enclosure (industrial type DB) 20A ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement of 3 pin plug suitable for sheet metal enclosure (industrial type DB) 20A ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in Replacement of 16 Amp plug top with indicator ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Socket 16 Amp multipurpose shutter type fixed on laminated sheet top cover ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Switch 16 Amp fixed on laminated sheet top cover ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement Brass chromium plated fancy type bib tabs of size 15 mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement MCB B Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 4.0 sqmm drawn into and including electrical grade PVC conduit medium grade not less than 20 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour ; Complete all as specified and directed by Engineer-in-charge.
SOLAR WATER HEATING SYSTEM Disconnecting electrical connection of solar heating device carefully dismantling solar panel with water tube (copper assembly/ETC tube) rubber gasket; nut bolt; biding aluminum channel and glass carefully and servicing/Descaling/cleanning with acid & water circulation and wire brush and brazing of cooper tube checking of leakage if any . After servicing reassemble the same and testing of solar water heater ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of gas kit set for ETC tube All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of ETC tube holder without cups .All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of solar evacuated tube of solar water heater as per existing suitable for 300/ 500 LPD , complete with washer etc complete all as specified and directed. make - Solar Maxx/inter solar/Tata BP Solar
Supplying and fixing rotational moulded polythelene water storage tanks(Triple layer) capacity 500 litres(cylindrical vertical with closed top), with and including 20mm dia float valve with brass fittings hoisted, fixed in position and making connection including dismantling of existing unserviceable tank complete all as specified. Make :-- sintex, Rotex, Fusion
Supply and fixing in replacement of aluminium foil for solar collector All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of rubber grommet (for collector). Make : Inter Solar, Sintex, sun magic are equivalent make in market
supply and fixing in replacement of MS dead flange. All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of heat pipe for collector All as specified and directed by Engineer-in- Charge.
Supply and fixing in replacement of round clamp for hose pipe. All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of brass flange. All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of Toughened/ tempered glass for solar collector having 4 mm thickness transmissivity more than 85 %.as per existing size All as specified and directed by Engineer-in- Charge
Material and labour for coolant/ Food Grade propylene glycol/ etylene glycol for solar heating system all as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of heating element INCOLOY type for water heating system 3 KW as per sample ISI Marked with rubber gasket of suitable Size. All as specified and directed by Engineer-in- Charge Make Racold/inter solar
Supply and fixing in replacement of thermostate ISI marked suitable for solar heater All as specified and directed by Engineer-in- Charge.
Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 500 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank ; Complete all as specified and directed by Engineer-in-charge.
Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 300 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank ; Complete all as specified and directed by Engineer-in-charge.
Suppply and fixing GI Pipe size 25 MM dia med grade galvanised with all fitting All as specified and directed by Engineer-in- Charge
Suppply and fixing GI Pipe size 20 MM dia med grade galvanised with all fitting complete all as specified and directed by Engineer-in- Charge
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of size 20 mm dia ; Complete all as specified and directed by Engineer-in-charge.
Suppply and fixing CPVC Pipe size 25 MM dia suitable for hot water with all fitting all as specified and directed by Engineer-in- Charge.
Suply and fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 25 mm dia All as specified and directed by Engineer-in- Charge
Suply and fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 20 mm dia All as specified and directed by Engineer-in- Charge
RO SYSTEM Disconnecting electrical connection/water connection of RO System carefully dismantling and change the defecting part and reassembling and testing after changing the defects parts. Make Kent, Aqua fresh are equivalent in market
Supply and fixing in replacement RO membrane in welded housing All as specified and directed by Engineer-in- Charge Make Kent, Aqua Guard or Pureit
Supply and fixing in replacement of filter housing ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of SMPS 2.5A 24V DC ADAPTOR with incoming and outgoing wires All as specified and directed by Engineer-in- Charge Make Kent, Aqua Guard or Pureit.
Supply and fixing in replacement sediment filter; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement activated carbon filter All as specified and directed by Engineer-in- Charge.Make Kent, Aqua Guard or Pureit.
Supply and fixing needle control valve assembly ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing plastic pipe 1/4 " blue ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing plastic pipe 1/4 " white ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing elbow PL0404 for 1/4" pipe ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement Solenoid valve 24V DC ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement FRT-800ML ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement LP &HP switch ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Diaphragm Pump 150GPD ; Complete all as specified and directed by Engineer-in-charge.
CENTRAL AC PLANT Material and labour for maintenance of central AC plant (chiller unit 01x 39 TR) with complete decsaling with the help of pressure motor and decsaling material all as specified and directed by engineer-in- charge
Material and labour for maintenance of Air handling unit with complete cleaning with the help of pressure motor and oil and greasing to all bearings all as specified and directed by engineer-in- charge.
Repair / replacement of Air handling unit fine filters suitable for ICUs all as per existing sample all specified and directed by engineer-in-charge
Repair / replacement of Air handling unit wire mesh filters suitable for ICUs all as per existing sample ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Fan belt No- A1382 Lp/A53 for AHU motor ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Fan belt No- A1433 Lp/A53 for AHU motor ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Fan belt No- B 1618 Lp/B62 for AHU motor ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Cooling tower fan assembly (1200 mm)blade as per sample ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing digital wall mounted temp and humidity meter ISI marked ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing Pressure guage of 100 psi kg/ cm sq for condencing and chiller water pipe line ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing line operated three phase AC monoblock motor 7.5 HP, 1450 RPM of BRG: DE/NDE 6208 2Z/6208 2Z , IP -55, IE2, ISI mark of cat No- MHCITHS405X5 ( Havells ) for AHU of capacity 8000 CFM all as specified and directed by Engr in Charge( Note :- Old Unsv motor will be deposited to E/M store yard )
Supply and fixing line operated three phase AC monoblock motor 5 HP, 1450 RPM of BRG: DE/NDE 6206 2Z/6206 2Z , IP -55 ,IE2 ,ISI mark of cat No- MHCITHS403X7 ( Havells ) for AHU of capacity 4000 /4500 CFM all as specified and directed by Engr in Charge( Note :- Old Unsv motor will be deposited to E/M store yard )
Material and Labour for charging of refrigerant Gas R-407 C complete all as specified after carrying out leak test and arresting the leakage ; Complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement heating element of capacity 4 KW suitable for hot water generator all as per sample ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for cleaing of cooling tower complete all as directed incl removal of all dust and replament of Nylon Jali as per sample and ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for servicing of Condensor / chiller pump of capacity 5 HP complete incl oiling greasing of bearing , replacement of shaft seal of Pump set ; Complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement butterfly valve ISI marked 100 mm dia ; Complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement butterfly valve ISI marked 150 mm dia ; Complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement chiller sensor all as per make and sample ; Complete all as specified and directed by Engineer-in-charge.
Attending day to day emergency complaints for geysers shock, sparking in geyser wiring , geyser not working etc ; Complete all as specified and as directed by Engineer-in-Charge. Notes for Sl Item No.86 (i) Contractor has to take the complaint at MES power house (E/M) from Concern JE E/M Daily Basis (Except Sunday & holiday). (ii) Contrcator has to attend the complaint within 24 Hrs after recived from JE E/M. (iii) Contrctor has to provide the Mobile no so that massges can be send on the same mobile No. (iv) For non collection of complaits from JE E/M Rs.500/- per day will be charged. (v) For Non attendence of complaints in 24 Hrs Rs.200/- per day per complaint will be charged (vi) Contractor has to return the complaint duly signed from the user with time & date.
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .