| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹12,182 (0.11%)Rejected-Finance | ₹1.1 Cr+₹12,182 (0.11%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.3 Cr+₹25.9 L (23.9%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.3 Cr+₹25.9 L (23.9%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹1.6 Cr+₹51.3 L (47.2%)Rejected-Finance | ₹1.6 Cr+₹51.3 L (47.2%) | L4 | Rejected-Finance Not Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
17 Apr 2024, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
ADDITION ALTERATION TO BLDG No. P50 FOR ISR PROJECT AT CABS BENGALURU
2024_MES_641687_4
82651
Open Tender
Civil Works
Item Rate
270 days
BANGALORE
Class B
Category a (i)
8 documents required · 8 mandatory
₹1,000
GARRISON ENGINEER RND EAST BANGALORE
₹1.8 L
Yes
17 May 2024
27 Mar 2024
24 Apr 2024
27 Mar 2024
17 Apr 2024
3 Apr 2024
Amount
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba / rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge for door / window / clerestory window.
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-Charge.
Finishing walls with textured paint of required shade (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of primer applied @ 2.20kg/10 sqm complete all as specified and directed.
Providing & fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
All as per Sl item No. 05 above but for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (fittings shall be paid for separately) powder coated aluminium (minimum thickness of powder coating 50 micron).
Providing & fixing glazing in aluminium door, window, ventilator shutters and partitions etc, with EPDM rubber / neoprene gasket etc, complete as per the architectural drawings and the directions of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item): with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) complete all as specified and directed.
Providing & fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc, complete as per architectural drawings and directions of Engineer-in-Charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side complete all as specified and directed.
Providing & laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed.
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-Charge.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed.
Painting with synthetic enamel paint of approved brand and manufacture to give an even two or more coats on new work complete all as specified and directed.
Disconnecting damaged overhead / terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-Charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed (02 Nos, 1000 litres capacity).
Providing & fixing in repairs Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints including taking down old pipe complete as per direction of Engineer-in-Charge 25 mm nominal dia pipes.
Providing & fixing in repairs gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore complete all as specified and directed.
Providing & fixing in repairs ball valve (brass) of approved quality, high or low pressure, with plastic floats complete 25 mm nominal bore complete all as specified and directed.
Providing & fixing 2nd class teak wood flooring plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface 12 mm thick complete all as specified and directed.
Providing & fixing of gypsum board false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45 x 15 x 0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter
channel 0.5mm thick 27mm high having flanges of 20mm and 300mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450mm centre with 25mm long wall dry screws @ 230mm interval including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and including 2mm thick wall care putty over a coats of primer and two coat of premium emulsion paint suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-Charge with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-(Part I): 2011 (Board with BIS certification marks) including dismantling and taking down old existing false ceiling of any type.
S&F, 12mm thick wave free toughened one way vision glass with SS-316 grade steel fittings, fish mouth channel in bottom and top as per design with and including provision of all other neccessary fixture and accesaries, complete all as specified and directed.
S&F, black / golden colour solar control film 50micron reflective type sticked to glass panes as per instruction of manufacturer complete all as specified and directed.
S&F, roller blinds type with approved fabric and powder coated aluminium fittings such as top rails metal weight nylon button loops etc to match with the top rail metal base complete all as specified and directed. Make: VISTA, MAC&MARC.
Mild steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, in stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, complete all as specified and directed.
S&F, 30mm thick regid PUF TR panel made out of profiled sheet on top and plain sheet at bottom with CFC free pentane blown polyurethane foam as the core (the core is CFC/HCFC free pentane blown polyurethane foam density of 40+2 kg/cum in 50mm thick sheet) the panel sheet having 1000mm cover width, 34.5mm crest height @333mm c/c made out of 0.5mm TCT 300mpa stress, colour coated galvalume steel sheet 150 GSM aluminium zinc coated with 20 micron polyester paint, the sheet shall be fixed with self drilling self tapping fasteners complete all as specified and directed.
Taking down carefully unserviceable aluminium / copper point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, removing all material for reuse / issued under schedule of credit and making good the disturbed surface to match with existing surface, complete all as specified and directed.
Taking down old sub main wiring of any type and size complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm single core, PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 Volts grade conforming to IS 694 drawn through and including non metallic rigid PVC conduit 25mm dia medium grade and conduit accessories such as bends, tees, junction boxes etc concealed in walls duly chiselling / grooving as required except in beams, roof and making good the disturbed area to match with adjoining surfaces including single core, PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 Volts grade conforming to IS 694 as earth continuity wire including modular switches 6A, modular GI flush boxes by providing modular cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators etc all as specified and directed for One light point / fan point controlled by one, one way modular switch.
M&L for sub main wiring with 2 runs of 1.5 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit acessories concealed in walls / floors / ceiling etc duly cutting chases / grooves and making good the distrubed surfaces to match with existing surfaces including 1 run of 1.5 Sq mm single core copper conductor cable, PVC insulated, sheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: 3 runs of 1.5 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
All as per Sl item No. 28 here-in-above but sub main wiring with 2 runs of 2.5 sq mm and 1 run of 2.5 Sq mm as earth continuity conductor. Note: 3 runs of 2.5 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
All as per Sl item No. 28 here-in-above but sub main wiring with 2 runs of 4 sq mm and 1 run of 4 Sq mm as earth continuity conductor. Note: 3 runs of 4 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
All as per Sl item No. 28 here-in-above but sub main wiring with 2 runs of 10 sq mm and 1 run of 10 Sq mm as earth continuity conductor. Note: 3 runs of 10 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
All as per Sl item No. 28 here-in-above but sub main wiring with 4 runs of 10 sq mm and 2 runs of 10 Sq mm as earth continuity conductor. Note: 6 runs of 10 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
All as per Sl item No. 28 here-in-above but sub main wiring with 4 runs of 16 sq mm and 2 runs of 16 Sq mm as earth continuity conductor. Note: 6 runs of 16 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin, 5/6 Amps modular socket outlet and 5/6 A modular switch and making connections etc as required complete all as specified and directed.
S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin, 5/6 & 15/16 Amps modular socket outlet and 15/16 A modular switch and making connections etc as required complete all as specified and directed.
S&F, ceiling rose surface backelite two to three terminal 230 volts complete all as specified and directed.
S&F, recess mounted full panel LED luminaire 36 watt fitting of size 2' x 2' with white powder coated housing and frame in CRCA sheet, high efficiency LED grade diffuser, electronic driver duly pre-wired upto terminal block, CRI>80, Colour temperature-5700K, IP20, 50000 burning hours as per L70 Criteria, Ambient temperature-0 to 50DegC, Driver Efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-3KV, Multistage isolated Constant current-Constant voltage operated driver with range 150-270V AC and Safety extra low voltage safe level<60V DC as per IEC Standard and making connections etc as required complete all as specified and directed.
S&F, recess mounted LED swivel spot light fitting 12 watt aesthetically designed lens based accent light for crisp light out put suitable of LED 4000K and making connections etc as required complete all as specified and directed.
Supply and fixing LED light fitting 20 watts decorative ultra slim round LED light fixture with extrudded polycarbonate housing, environment friendly energy efficient type duly pre-wired complete all as specified and directed.
M&L for taking down old existing light fittings of any type and size and refixing in another location as rquired at site complete fixing arrangement and making electric connections complete all as specified and directed.
S&F, wall mounted fans 300 mm sweep PVC body single phase, 230/240 V, AC, 50 Hz with complete fixing arrangement and making electric connections complete all as specified and directed.
S&F, VTPN MCCB distribution board TP&N 4 way, 415 Volts, vertical type with epoxy powder coated with sheet steel enclosure double door, IP 43 protection with 200 Amps rated bus bar suitable for mounting MCCB as incomer and MCB TP/SP as outgoings and making electric connections as required and complete all as specified and directed.
S&F, MCB distribution board TP&N 8 way, 415 V, epoxy powder coated with sheet steel enclosure, IP-43 protection, double door fixed flush to wall and suitable for universal mounting with 200 A copper bus bar, neutral bar, standard DIN rail, earth bar and making electric connections as required complete all as specified and directed.
S&F, MCCB 200Amps, 4P, 16 KA, 415 V, 50Hz, AC with adjustable TM setting and making electric connections as required complete all as specified and directed.
S&F, MCB TP&N 63 Amps, 415 volts, 10 KA, 'C' curve complete all as specified and directed.
S&F, MCB DP 32 Amps, 240 volts, 10 KA rupturing capacity complete all as specified and directed.
S&F, MCB SP 6-32 Amps, 240 volts, 10 KA, 'C' curve complete all as specified and directed.
S&F, metal clad plug and socket outlet 2 pole and earth with plug top alongwith MCB SP 20 A "C" curve, 230V, 50 Hz in recess flush in wall with chained metal cover for the socket out let and making connections complete all as specified and directed.
S&F, metal clad plug and socket outlet 2 pole and earth with plug top alongwith MCB SP 32 A "C" curve, 230V, 50 Hz in recess flush in wall with chained metal cover for the socket out let and making connections complete all as specified and directed.
M&L for earthing complete with galvanised iron plate electrode 600 x 600 x 6 mm thick GI earthing lead buried directly in ground vertically to a depth not less than 2.25 m deep below GL with the top edge of the plate at a depth not less than 1.5m from below normal GL connected to and including galvanised iron strip 25 x 5 mm as earthing lead by means of nuts, bolts, washers, check nuts of galvanised iron and connected to earthing test point and as specified or indicated and testing on completion including excavation / earthwork in any type of strat PCC (1:3:6) type C1 earthing chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kgs of 40mm bore light grade and lugs with and lugs, including GI earth strip with GI protection pipe of 40mm light grade 7.5m long etc complete all as specified and directed. Note: Rate quated shall deemed to include cost of excavation in any type of statra, RFR and removal upto 50 metre, PCC Pit, funnel and RCC cover plate, GI pipe etc.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick GI earthing lead buried directly in ground vertically to a depth not less than 2.25 m deep below GL with the top edge of the plate at a depth not less than 1.5m from below normal GL connected to and including copper strip 25 x 5 mm as earthing lead by means of nuts, bolts, washers, check nuts of galvanised iron and connected to earthing test point and as specified or indicated and testing on completion including excavation / earthwork in any type of strat PCC (1:3:6) type C1 earthing chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kgs of 40mm borelight grade and lugs with and lugs, including copper strip with GI protection pipe of 40mm medium grade 7.5m long etc complete all as specified and directed. Note: Rate quated shall deemed to include cost of excavation in any type of statra, RFR and removal upto 50 metre, PCC Pit, funnel and RCC cover plate, GI pipe etc.
S&F, GI strip of size 25 mm x 5 mm on surface for connections beyond 7.5 metres complete all as specified and directed. Note: The rates are included with all fixing accessories / arrangement as directed.
S&F, copper strip of size 25 mm x 3 mm on surface for connections beyond 7.5 metres complete all as specified and directed. Note: The rates are included with all fixing accessories / arrangement as directed.
S&F, non metallic rigid PVC conduit 25mm dia medium grade and conduit accessories such as bends, tees, junction boxes etc concealed in walls duly chiselling / grooving as required except in beams, roof and making good the disturbed area to match with adjoining surfaces complete all as specified and directed.
S&F, modular metal box of size 75 mm x 75 mm x 60 mm deep (nominal size) in recess including modular plate and frame etc complete all as specified and directed.
S&F, telephone socket RJ 11 (Jack type) outlet and making connections complete all as specified and directed.
S&F, LAN cable socket RJ 45 UTP information outlet tool less 2 module type and making connections complete all as specified and directed.
Supplying and drawing telephone cable 2 pair of size 0.5 mm dia PVC insulated annealed copper conductor drawn in PVC conduit and making connections complete all as specified and directed.
Supplying and drawing telephone cable 4 pair of size 0.5 mm dia PVC insulated annealed copper conductor drawn in PVC conduit and making connections complete all as specified and directed.
S&F, modular type internate socket and making connections complete all as specified and directed.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable of 2 runs drawn in PVC conduit and making connections complete all as specified and directed.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable of 3 runs drawn in PVC conduit and making connections complete all as specified and directed.
Supply, fix, testing & commissioning of On-Line UPS of capacity 40 KVA suitable for 3 Phase 360-440 V input and 3 Phase output 415 V ± 1%, 50 Hz for 30 minute Back up time complete with latest IGBT technology, smart touch panel LCD display, active PF correction and other factors as per latest technology and comprising of Isolation transformer 3 phase 40 KVA and Sealed Maintenance Free Battery 12V, 65 Ah of quantity 40 Nos and along with pre-fabricated open metal rack suitable for installation of complete batteries duly pre wire and making electric connections as required complete all as specified and directed.
S&F, industrial plug and socket with MCB FP 63 Amps, 415 V, AC, 50 Hz suitable for (3P+N+E) complete with all accessories and making electric connections as required complete all as specified and directed.
S&F, industrial plug and socket with MCB FP 32 Amps, 415 V, AC, 50 Hz suitable for (3P+N+E) complete with all accessories and making electric connections as required complete all as specified and directed.
S&F, industrial plug and socket with MCB DP 32 Amps, 240 V, AC, 50 Hz suitable for (3P+E) complete with all accessories and making electric connections as required complete all as specified and directed.
S&F, sheet metal enclousure suitable for MCCB 4 pole, 415V upto capacity 100 Amps complete all as specified and directed.
S&F, MCCB 100Amps, 4P, 16 KA, 415 V, 50Hz, AC with adjustable TM setting and making electric connections as required complete all as specified and directed.
S&F, MCB TP 63 Amps, 415 volts, 10 KA, 'C' curve complete all as specified and directed.
S&F, MCB TP 32 Amps, 415 volts, 10 KA, 'C' curve complete all as specified and directed.
Supply, fix, testing & commissioning of floor mounted tower air conditioner of capacity 4.0 TR suitable for working on 3 phase, 415 volt, 50 Hz 5 star rated with latest inverter technology scroll compressors, copper condenser, LCD display, cordless remote control system, initial filling of eco friendely refrigerent gas and outdoor unit and indoor unit and necessary fixing arrangement by providing bracket and clamps including adequate size and length of copper tubing and copper conductor cables and other components as required and making connections complete all as specified and directed.
Supply, install, testing & commisioning of split type air conditioner of capacity 2.0 TR, five star rated hi wall split units indoor and outdoor with cordless remote control unit and with in-built air ioneser and plasma filter for better indoor Air quality with latest inverter technology, initial filling of eco friendely refrigerent gas and outdoor unit and indoor unit and necessary fixing arrangement by providing bracket and clamps including adequate size and length of copper tubing and copper conductor cables and other components as required and making connections complete all as specified and directed.
S&F, voltage stabilizer of capacity 5 KVA for automatic operation, phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and making connections complete all as specified and directed.
S&F, voltage stabilizer of capacity 10 KVA for automatic operation, three phase naturally air cooled indoor type and designed for input variation between 390 V to 440 V with output voltage stabilized at 415 V with accuracy of ± 2.5% and making connections complete all as specified and directed.
S&F, electrically operated air curtain 6 feet size with sencer type including remote controller 230 volts, 50Hz including other accessories and necessary fixing arrangement as required at site and making connections complete all as specified and directed.
M&L for sub main wiring with 4 runs of 6sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit acessories concealed in walls / floors / ceiling etc duly cutting chases / grooves and making good the disturbed surfaces to match with existing surfaces including 2 run of 6 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: 6 runs of 6 Sq.mm and 1 run of PVC conduit will be measured and paid as one unit.
S&F, metal clad plug and socket outlet 3 pole and earth with plug top alongwith MCB TP 32 Amps "C" curve, 415V, 50 Hz in recess flush in wall with chained metal cover for the socket out let and making connections complete all as specified and directed.
Supply and laying, CPVC pipes of size 50 mm nominal dia (chlorinated polyvinyal chloride) having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes and fittings with one step CPVC solvent cement and testing of joints including taking down old pipe complete all as specified and directed.
Supply and laying, CPVC pipes of size 32 mm nominal dia (chlorinated polyvinyal chloride) having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes and fittings with one step CPVC solvent cement and testing of joints including taking down old pipe complete all as specified and directed.
Supply, laying, jointing, testing & commissioning LT cable of size 95 Sqmm, 3.5 core, XLPE insulated, 1100 volts grade, armoured with galvanised round steel wire or steel strip electric power cable heavy duty with multi stranded aluminium conductor laid in trenches, ducts fixed on walls / poles with proper size saddles and clamp drawn through pipeand making connections with aluminium lugs, steel glands etc complete all as specified and directed.
Supply, laying, jointing, testing & commissioning LT cable of size 70 Sqmm, 3.5 core XLPE insulated, 1100 volts grade, armoured with galvanised round steel wire or steel strip electric power cable heavy duty with multi stranded aluminium conductor laid in trenches, ducts fixed on walls / poles with proper size saddles and clamp drawn through pipeand making connections with aluminium lugs, steel glands etc complete all as specified and directed.
S&F, On-Load change over switch 160 Amps, TP&N, 415 Volt complete in sheet steel enclousure with necessary fixing arrangement as required at site including making connections complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in hard / dense soil for laying of UG cable complete all as specified and directed.
Removal of surplus soil to a distance n exc 50mtr a part and depositing where directed n exc 1.5 mtr above the starting point complete all as specified and directed.
Returning filling and including spreading leveling, watering and well ramming in layers n exc 25cm in soft loose soil complete all as specified and directed.
Supply and spread dry river sand in trenches for cable cushioning of 23cm on both top and bottom of cable and punned down to 18cm complete all as specified and directed. Note: For the purpose of payment the punned thickness only measured.
Supplying and laying un-reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
M&L for demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road / floor / platform etc including form work compaction etc complete all as specified and directed.
Supplying & laying, GI pipe 80 mm dia light grade for protection of cable in road crossing / on wall / on pole as required at site complete all as specified and directed.
B5BUILDING SOLUTIONS
Lucky Enterprises
D NAGI REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .