Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.0 L+₹2.0 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹21.5 L+₹2.5 L (13.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹23.3 L+₹4.4 L (23.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹23.4 L+₹4.5 L (23.6%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
PETTY REPAIR TO E/M NATURE OF WORKS AND CONNECTED ITEMS AT VARIOUS MD ACCN AND OTM ACCN AT VASANT RANGE COLONY, 5 RAJPUT, IHQ OF MOD (ARMY) CAMP, WARDEC, CAMS, 1 CBPO, IML, KHYBER LINE AND HQ DGIS UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2023_MES_607260_1
GE/DS-49/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹70,000
Yes
6 Sept 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
29 Jul 2023
15 Jul 2023
Amount
Attending complaints between 0845 Hrs to 1645 Hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
All as per Srl item No. 1 above, but attending complaints in between 1645 hrs to 2345 Hrs.
Notes for Srl item Nos.01 & 02 :- This item is applicable only where no store is required. 1. The site for attending complaints are VRC, 5 Rajput, HQ DGIS, IHQ of MoD (Army), WARDEC, 1 CBPO, IML, CAMS & Khyber Line and Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7.The above tradesmen shall not be utilized for the items entered here-in-after as taking down, S&F, M&L, S&F in repairs M&L in repairs etc. and the rate quoted by tenderer are deemed to be included for the same. 8. The material like PVC copper cable 1.50/2.50 Sqm upto 3.00 Mtr, fuse, screws, insulation tape, copper thimbles, glands etc. requried to make the electricity functional are to be arranged by the contractor and the quoted rates are deemed to be included for the same.
Taking down burnt/unserviceable copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ new PVC Conduit concealed and including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per Srl item No.4 above, but one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on independent board.
All as per Srl item No.4 above, but one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on same board.
All as per Srl item No.4 above, but point wiring for 16 Amps for modular socket point with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amps modular switch/socket outlet point on independent board.
All as per Srl item No.4 above, but for one AC point controlled using cable of 4 Sq mm for phase and neutral and 4 sqmm for earthing.
S&F switch modular type, 1Module, 6 Amps one way complete all as specified and as directed.
S&F socket outlet modular type 2M, 2/3 pin, 6 Amp complete all as specified and as directed.
S&F switch modular type 1M, 16 Amp complete all as specified and as directed.
S&F socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp complete all as specified and as directed.
S&F electric bell ding dong AC, 230 volts single phase complete all as specified and as directed.
S&F Bell push modular type 1M 5/6 Amp complete all as specified and as directed.
S&F elctronic fan regulator, modular type 2M, 4 steps complete all as specified and as directed.
S&F modular box with MCB 20 Amp complete with metal box and 3 Pin top plug as per sample complete all as specified and as directed. Note : Rates are inclusive of cutting/chases for mounting modular metal box concealed in wall and making good to disturbed surfaces with OBD/Colour wash/white wash and wall putty where ever required complete all as specified and as directed.
S&F in repairs switch modular type, 1Module, 6 Amps one way as per sample complete all as specified and as directed.
S&F in repairs switch modular type 1M 6 Amp 2-way as per sample complete all as specified and as directed
S&F in repairs socket outlet modular type 2M, 2/3 pin, 6 Amp as per sample complete all as specified and as directed.
S&F in repairs switch modular type 1M, 16 Amp as per sample complete all as specified and as directed.
S&F in repairs socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp as per sample complete all as specified and as directed.
S&F in repairs electronic fan regulator, modular type 2M, 4 steps as per sample complete all as specified and as directed.
S&F in repairs electric bell ding dong AC, 230 volts single phase complete all as specified and as directed.
S&F in repairs bell push modular type 1M 5/6 Amp as per sample complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed. One light/fan/bell point/security light conrrolled by one way switch. Note:- The rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.
All as per Srl item No.16 above, but one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm size suitable concealed PVC/MS conduit.
All as per Srl item No.16 above, but 5 Amp socket outlet on same board.
All as per Srl item No.16 above, but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit.
All as per Srl item No.16 above, but for one AC point controlled using cable of 4 Sq mm for phase and neutral and 4 sqmm for earthing.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
S&F switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
S&F universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
S&F electronic fan regulator, 4 steps complete all as specified and as directed.
S&F in repairs switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F in repairs socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
S&F in repairs switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
S&F in repairs universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
S&F in repairs ectronic fan regulator, 4 steps, as per sample complete all as specified and as directed.
S&F in repairs switch piano flush type 6 Amps SP 2-way as per sample complete all as specified and as directed.
S&F in repairs bell push, flush type 6 Amps as per sample complete all as specified and as directed
S&F in repairs LED Bulb 12 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/SK light fittings ias per sample complete all as specified and as directed.
S&F in repairs of ceiling fan capacitor of 2.5 mfd complete all as specified and as directed. Make : TIBCON/AE/ EPCOS/Havells
S&F in repairs of ceiling fan capacitor of 3.15 mfd complete all as specified and as directed. Make : TIBCON/AE/ EPCOS/Havells
S&F in repairs decorative wall light mounting suitable for LED lamp upto 15 Watt complete all as specified and as directed.
S&F in repairs ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F in repairs lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs wall mounted LED integrated batten T-5 20 Watt - 4ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
S&F in repairs wall mounted LED integrated batten T-5 10 Watt - 2ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
S&F in repairs wall mounted LED integrated batten T-5 10 Watt - 2ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
S&F in repairs LED 10 Watt white bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 2.5 Sqmm in 2 runs and 2.5 Sqmm one run for earth drawing through existing PVC concealed conduit complete all as specified and as directed. Note for Srl item No 44 to 46:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in repairs MCCB 125 Amps 4 pole 415 volts fixed type with breaking capacity 16 kA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
S&F in repairs MCB SP 10 to 40 Amps 240 Volts, 10 KA, `B' curve, all as per site requirement complete all as specified and as directed.
S&F in repairs MCB SPN 40/63 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement complete all as specified and as directed.
S&F in repairs MCB TPN 63 Amps 415 volts, 'B' Series 10 KA as per site requirement complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed in green colour complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
S&F in repairs plastic laminated sheet top cover 3mm thick of size 8"x5" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed.
S&F in repairs plastic laminated sheet top cover 3mm thick of size 11"x9" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed.
S&F in repairs MS sunken box of size 8"x11" to fixing of switch board concealed with necessary screws and washers complete as per sample complete all as specified and as directed.
S&F in repairs sheet metal enclosure of size 350 x 300 x 150 mm suitable for mounting electronic meter fabricated from CRCA sheet with anti corrosive dust and vermin proof complete all as specified and as directed. Note:- The meter cover shall have a transparent window. The window shall be of transparent, high grade UV stabilizer engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover.
S&F in repairs MCB DB SPN 8 Way double door type, (IP 43 Protection) flush mounting as per sample complete all as specified and as directed.
S&F in repairs LED Building security light fitting 40W including GI 25mm bracket in replacement of old unsv existing security light fitting any type complete all as specified and as directed.
S&F in repairs distribution board V-TPN 4 way for fixing MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting, in replacement complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4, type B-1, pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement including taking out old unserviceable earthing complete all as specified and as directed.
S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth iron strip 32x6mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement including taking out old unserviceable earthing complete all as specified and as directed.
S&F in repairs earth continuity conductor or main earthing lead fixed to roof wall other indicate situation for loop earthing etc. as required 25x4 mm dia galvanised iron strip as per site requirement complete all as specified and as directed. Note :- The quoted rates are deemed to be included for necessary scaffolding required.
S&F in repairs 2x2 Panel light surface mounted LED light of 40 W fixture with opal diffuser to give glare free light including suitable LED light of 40 W suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
S&F in repairs recessed/surface mounting 40 watt 1' x 4' ' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
S&F in repairs LED 16/18W LED 1'x1' light recess/surface mounted with LED luminaires made in CRCA sheet metal with fliexble wire complete all as specified and as directed.
S&F in repairs Flexible copper 3 Core, 2.5 Sqmm twin core complete all as specified and as directed.
S&F in repairs rigid PVC conduit 20mm dia including accessories tees, bends, reducer, cooption, riddles etc complete all as specified and as directed.
S&F in repairs casing caping size 20x12 mm of ISI Mark or as per manufacturer design withh all accessories for surface wiring complete all as specified and as directed.
S&F in repairs thermostat 9/11" (ISI Marked) for 25 Litres capacity Geyser as per sample complete all as specified and as directed.
S&F in repairs MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
S&F in repairs heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.
S&F in repairs Exhaust fan MS Louvers upto 450 mm Size, as per sample up to Third floor complete all as specified and as directed. Note:- The quoted rates are deemed to be included for necessary scaffolding required.
S&F in repairs PVC Pipe brass nipple 15 mm x 600 mm for Hot & Cold water with brass nuts and washers stainless steel at both ends of length not exc. 60 cms for connection of stainless steel as per sample complete all as specified and as directed.
Supply, laying and testing of cable XLPE insulated screened PVC bedded, galvanised steel strip armoured ,electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 50 sqmm, 3.5 core including taking out old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 95sqmm, 3.5 core on wall and trenches complete all as specified and as directed.
M&L for excavation in trench not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable etc and getting out in soft/loose soil complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering consolidation complete all as specified and as directed.
Supply and laying repairs bricks common burnt clay building sub class 'B' designation 75 complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exe 25 cm complete all as specified and as directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Supplying and laying including taking out G.I. tubing light grade of 50mm bore for encasing lt cables for mechanical protection, laid under plinth/floors/roads/paths/culverts or fixed on walls or concealed in walls or along the steel poles incl bends/clamps and all accessories including taking out old unserviceable cable and pipe complete all as specified size of 50 mm bore complete all as specified and as directed.
M&L for taking out LT Cable 3.5 core upto 50 Sqmm size cable from the cable loop and making connection to V-TPN DB with suitable size of thimbles including necessary excavation & returning filling in and 40mm dia light grade GI protection pipe upto 50 cm length complete all as specified and as directed.
Boring holes under road pavement by bocky manually in any type of soil upto 50 mm bore complete all as specified and as directed.
S&F in repairs surface mounted round shaped LED downlight with durable housing with Al heat shrink with diffuser to give glare free light 12 watt LED 6000K/6500K lamp type from ceiling of stairs/common areas, complete all as specified and as directed.
S&F in repairs PRCD plug top 16 Amps, 30mA complete all as specified and as directed.
S&F in repairs LED post top lantern fitting with die cast aluminium spigot, spun aluminum powder coated top cover Aluminum PDC heat sink opal PC diffuser clear acrylic IP-65 with 40 Watt power including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete including making a hole in pillar/wall with light grade GI pipe of suitable size for fixing the post top lanter fitting complete all as specified and as directed.
S&F in repairs copper cable, 1100 volts grade 25 Sqmm, 3 Core complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
Vijeta Solutions
M/S Malik Construction Corporation
H S KALSI AND BROS
SABHARWAL CONSTRUCTION CO.
RAJDHANI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .