| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC ACCEPTANCE | |
| 2 | L2₹18.4 L+₹687.20 (0.04%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹19.0 L+₹60,060.20 (3.27%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹20.7 L+₹2.3 L (12.4%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹21.9 L+₹3.5 L (19.2%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-Finance L5 |
Tender Value
₹24.7 L
EMD Value
₹49,400
Closing Date
2 Apr 2024, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIR OF AUTOMATIC FIRE DETECTION SYSTEM (AFDS) AT P 01 COMNETCEN(KAR) BUILDING AT NAVAL BASE KARWAR UNDER GE (SB) KARWAR
2024_MES_645184_1
85763/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOC
9 documents required · 9 mandatory
₹500
GE (SB) KARWAR
₹49,400
Yes
1 Jul 2024
5 Mar 2024
4 Apr 2024
5 Mar 2024
2 Apr 2024
19 Mar 2024
Amount
Supply, installation, testing & commissioning of analog addressable fire alarm control panel complying with BSEN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detectors and modules, expandable till 6 Loops, LCD Display and required power supply & Batteries for 24 Hours in normal operation & 15 Minutes in Fire condition complete all as specified and directed.
Supply, installation, testing & commissioning in repair active repeater panel to be integrated with addressable fire alarm control panels, larger display and show status of any fire /fault of integrated fire alarm panles and activate fire alarm sounder/sierens complete all as specified and directed.
Supply, installation, testing & commissioning of network card. Network card shall connect panels and repeater panel through RS 485 data. The network module must be configured master/slave, multiple master/slave and peer to peer networking all as specified and directed.
Material and labour for Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination as per IS: 11360 all as specified and directed.
Material and labour for Addressable type heat detector with base with rate of rise cum fixed temperature as per IS: 2175 all as specified and directed.
Material and labour for Addressable manual call point resettable type all as specified and directed.
Material and labour for Addressable electronic sounder cum strobe all as specified and directed.
Material and labour for Remote response indicators all as specified and directed by Engr-in-charge.
Note for item Nos.1 to 8 :- (i) The existing make of Fire Alarm at site is of M/s Edward.All the items required for the work shall be of Edward make or compatible makes suitable for the existing Fire Alarm of Edward Make.
Material and labour in repairs for short circuit isolators complete all as specified and directed.
M & L for 2 core 1.5 sq mm multistranded copper armoured cable including taking down old cable complete all as specified and directed.
Material and labour in repair for 'Fire Alarm Sounders / Sirens Electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 500 mtrs range all as specified & directed.
Material and labour in repair for addressable control module complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.50 meter below ground level connected to but using GI strip 25x4 mm as earthing lead by means of bolts, nuts and washers check nuts of steel GI welding at all joints as shown in drawings and including necessary excavation, earth work in any type of soil, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to an including the earth test point of GI/steel of size 75x75x25 mm, supplying and laying charcoal dust, common salt , PCC (1:2:4) type B-1 (using 20mm graded aggregate) chamber and 40 x 40 x 3mm mild steel angle iron frame and RCC cover 40mm thick 1:2:4 (using 20mm graded aggregate) , reinforced with 6mm dia bars at 75 mm C/C both ways with 12 mm dia round bar MS handle PGI funnel and wire mesh 20 mm dia GI pipe light grade for for watering all as shown in plate No.3 of SSR Part-1 2009,and connected to earth test point including testing complete all as specified.
Supply and lay in repair GI tubing , 'light grade' of size 25 mm with all fittings as in cable protection , laid in trenches all as speciefied and directed.
Excavation in trench not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and not exceeding 1.5m for laying of LT under ground cables/GI pipes getting out as in soft /loose soil complete all as specified and directed.
Returing & filling in trench spreading ,leveling watering and well ramming in layers not exceeding 25 cm deep as in deep as in soil complete all as specified and directed.
Removing excavated material n.exc 50 mtrs and deposting where directed at a leve n.exc 1.5 mtrs above starting point as in soil complete all as specifed and directed.
vinayandsons
Continental Engineers and contractors
shanti enterprises
Shree Ayyappa Engineering
shakti engineering and electrical works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .