GE 970 EWS
GE 970 EWS C/o 56 APO
REPAIR AND MAINT OF LT PANELS INCL APFC PANELS EARTHING CABLES AND CONNECTED ITEMS AT OAF UNDER GE 970 EWS
2021_MES_409142_1
GE 970 EWS-62/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
OAF srinagar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE 970 EWS
₹70,000
Yes
13 Feb 2021
6 Jan 2021
6 Feb 2021
6 Jan 2021
3 Feb 2021
20 Jan 2021
Amount
Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) from various locations, including any short length and Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 120 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, cable glands and jointed in any description complete all as specified.
Ditto all as per item No 1 here in befor but of size 150 sqmm
Ditto all as per item No 1 here in befor but of size 185 sqmm
Ditto all as per item No 1 here in befor but of size 95 sqmm
Ditto all as per item No 1 here in befor but of size 70 sqmm
Ditto all as per item No 1 here in befor but of size 50 sqmm
Ditto all as per item No 1 here in befor but of size 35 sqmm
Ditto all as per item No 1 here in befor but of size 25 sqmm x 4 core
Ditto all as per item No 1 here in befor but of size 16 sqmm x 4 core
Ditto all as per item No 1 here in befor but of size 16 sqmm x 2 core
Ditto all as per item No 1 here in befor but of size 10 sqmm x 4 core
Ditto all as per item No 1 here in befor but of size 10 sqmm x 2 core Note for item No 1 to 12 :- 1. Excavation, Concrete cable protection bicks, pipe, PCC work for road crossing / hard standing and Sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel / bottle neck type/ring type or any shape), gable gland, new nut, bolt and washers of required size / description are deemed to include in this rate.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
Removal of surplus soil not exceed to a distance of 50 mtr where directed at a level not exc . 1.5M above the starting point
Supply and laying dry river sand / M-Sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only measured and paid
M & L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
S & F in repairs LT Control panel board, outdoor type,double door, padestal mounted, overall size not less than 900 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 500 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Location : At GE 970 EWS Main office
Incoming :-
a) Provision for MCCB 4 Pole, 315 Amp, 35 kA 415V - 01 No.
d) Copper wound with CTR 400/5 - 01 set.
e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
Outgoing :-
a) Provision for MCCB 4 Pole, 250 Amp, 35 kA 415V - 01 Nos.
b) Provision for MCCB 4 Pole, 100/125 Amp, 35 kA 415V - 01 Nos.
c) M & L for necessary grouting and fixing arrangements as reqd incl mounting nut, bolt and washers -01 Job
d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
S & F in repairs LT Control panel board, outdoor type,double door, padestal mounted, overall size not less than 1000 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 500 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Location : At Post No 20 LT Panel
Incoming :-
a) Provision for MCCB 4 Pole, 315 Amp, 35 kA 415V - 01 Nos
e) Copper wound with CTR 400/5 - 01 set.
f) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
Outgoing :-
a) Provision for MCCB 4 Pole, 200 Amp, 35 kA 415V - 02 Nos.
b) Provision for MCCB 4 Pole, 63 Amp, 25 kA 415V - 02 Nos.
c) M & L for necessary fixing arrangements by drilling and provn of fdn bolts in the existing floor - 01 job
d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
S & F in repairs LT Control panel board, outdoor type,double door, padestal mounted, overall size not less than 900 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 400 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Location : At SASE & Shopping Complex
Incoming :-
a) Provision for MCCB 4 Pole, 250 Amp, 35 kA 415V - 01 Nos.
e) Copper wound with CTR 250/5 - 01 set.
f) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
Outgoing :-
a) Provision for MCCB 4 Pole, 200 Amp, 35 kA 415V - 01 Nos.
b) Provision for MCCB 4 Pole, 100/125 Amp, 25 kA 415V - 01 Nos.
c) M & L for necessary fixing arrangements by drilling and provn of fdn bolts in the existing floor - 01 job
d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
S & F in repairs LT Control panel board, outdoor type,double door, padestal mounted, overall size not less than 900 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 400 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Location : At 256 Transist Camp Street light panel
Incoming :-
a) Provision for MCCB 4 Pole, 250 Amp, 35 kA 415V - 01 Nos.
e) Copper wound with CTR 250/5 - 01 set.
f) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
Outgoing :-
a) Provision for MCCB 4 Pole, 100/125 Amp, 25 kA 415V - 01 Nos.
b) Provision for MCCB 4 Pole, 63 Amp, 25 kA 415V - 03 Nos.
c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
d) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
S & F in repairs LT Control panel board, outdoor type,double door, padestal mounted, overall size not less than 900 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 400 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Location : At 33 KV MRS Main Road Panel
Incoming :-
a) Provision for MCCB 4 Pole, 250 Amp, 35 kA 415V - 01 Nos.
e) Copper wound with CTR 250/5 - 01 set.
f) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
Outgoing :-
a) Provision for MCCB 4 Pole, 200 Amp, 35 kA 415V - 01 Nos.
b) Provision for MCCB 4 Pole, 160 Amp, 25 kA 415V - 01 Nos.
c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
d) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
S & F in repairs LT Control panel board, outdoor type,double door, padestal mounted, overall size not less than 900 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 400 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Location : At JCO's Accn Street light Panel
Incoming :-
a) Provision for MCCB 4 Pole, 250 Amp, 35 kA 415V - 01 Nos.
e) Copper wound with CTR 250/5 - 01 set.
f) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
Outgoing :-
a) Provision for MCCB 4 Pole, 100/125 Amp, 25 kA 415V - 02 Nos.
b) Provision for MCCB 4 Pole, 63 Amp, 25 kA 415V - 01 Nos.
c) Provision for MCB 4 Pole, 32 Amp 415V - 02 Nos.
d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
e) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
Note for item No 11 to 18 : - (a) New MCCBs/ Change over switches are measured and paid seperately under relevent item of this schedule. (b) Rate for Interconnecting copper control cable along with necessary copper lugs are inclusive in the quoted rates. (c) The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval / layout /general arrangement for panel form Engg in Charge prior to commencement of work. (d) Cost for connecting of existing old UG cable of any size / type to new incoming / out going terminals by cutting the required length, addn/altrn and provision of necessary cable lugs, cable glands, nut, bolt and washers, etc., shall be included in the quoted rates.
M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable all as directed.
M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 185 to 300 Sqmm aluminium cable all as directed.
S & F in repairs MCCB 4 Pole, current rating 315/400 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of (Make : L & T Cat No CM93003OOOOX1 or equivalent in Legrand / Schenedier) incl necessary spreaders / cable lugs / nut, bolt and washers if required all as direcetd.
Ditto all as per item No 26 here in before but 4 pole 250 A, having breaking capacity 36 kA (Make : L & T Cat No CM92151OOOOX1 or equivalent in Legrand / Schenedier)
Ditto all as per item No 26 here in before but 4 pole 200 A, having breaking capacity 36 kA (Make : L & T Cat No CM92151OOOOX1 or equivalent in Legrand / Schenedier)
Ditto all as per item No 26 here in before but 4 pole 160 A, having breaking capacity 36 kA (Make : L & T Cat No CM92152OOOOX1 or equivalent in Legrand / Schenedier)
Ditto all as per item No 26 here in before but 4 pole 100 /125 A, having breaking capacity 36 kA (Make :L & T Cat No CM92153OOOOX1 or equivalent in Legrand / Schenedier)
Ditto all as per item No 26 here in before but 4 pole 63 A, having breaking capacity 36 kA, (Make : L & T Cat No CM92154OOOOX1 or equivalent in Legrand / Scheneider)
S & F in repairs of 3 pole power Contactor AC control 45 A capacity complete incl fixing arrangement all as direcetd. (Make L & T Cat No CS94110 or equivalent)
S & F in repairs of 3 pole power Contactor AC control 150 A capacity complete incl fixing arrangement all as direcetd. (Make : L & T Cat No CS94139 or Schneider /Siemens
S & F in repairs Four Pole on load manual operated changeover switch disconnector in open execution with sheet steel enclosure of current rating 250 Amps. Make : L&T Cat No CO32500OSOO or equivalent)
Ditto all as per item No 34 here in before but of capacity 400 A all as directed. (Make : L & T Cat No CO44000OSOO or equivalent)
S & F in repairs APFC Relays with auto set function having 6 + 1 steps 7 stage suitable for 415 Volts incl necessary connections all as directed. (Make : L & T Cat No ERPML07D500 or equivalent in Siemens / EPCOS)
S & F in repairs APFC Relays with auto set function having 4 + 1 steps 5 stage suitable for 415 Volts incl necessary connections all as directed. (Make : L & T Cat No ERPML05D500 or equivalent in Siemens / EPCOS)
S & F in repairs APFC Relays with auto set function having 3 steps 3 stage suitable for 415 Volts incl necessary connections all as directed. (Make : L & T Cat No ERPML03D500 or equivalent in Siemens / EPCOS)
S & F in repiars MPP type Box capacitor (Resin filled) three phase heavy duty type of capacity 20 to 50 KVAR rating suitable for 440 Voltage incl necessary connections all as specified. (Make : L & T / EPCOS / Siemens)
S & F copper bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board for any addition / alteration all as directed.
S & F in repairs Aluminium bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board all as directed.
S & F in repairs of copper control cable multistranded with suitable size copper lugs crimped on both side of any type of size 25 Sqmm for internal connection incl PVC tie all as direcetd.
Ditto all as per item No 42 here in before but of size 16 Sqmm
Ditto all as per item No 42 here in before but of size 10 Sqmm
S & F in repairs Copper wound with CTR 400/5 A rating all as directed.
S & F in repairs Copper wound with CTR 200/5A rating all as directed.
S & F in repairs Indicator Lamps (LED type) showing R,Y, B phase all as directed.
S & F in repairs MCB TPN 63Amps, 415 V as per all as specified.
S & F in repairs MCB TPN 32 amps 415 volts C series all as directed.
S & F in repairs MCB DP 32 Amps 240 volts C series all as direcetd.
S & F in repairs MCB SP 'C' series 10 Amps, 230V all as specified.
M & L for Earthing complete with galvanised steel earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to GI strip 32x 6 mm thick dia by mens of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing ten point all as specified and including necessary earth pit PCC 1:3:6 chanber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
S & F in repairs Galvanised iron strip 32 x 6 mm buried in ground / fixed on walls / ceilings by using suitable size GI saddles etc incl taking out old one all as specified.
Re-fixing of serviceable MCCB 3 / 4 pole of any capacity incl necessary suitable size fixing nut / bolt and washers in the new panel / old panel obtained from item No 11 to 20 where directed by Engg in Charge all as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 2 core stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sqmm nominal cross section in service connection / light connections in poles all as diretced
Supply and fix or laying in trenches / on wall / poles / structures in repairs GI tubing light grade for road crossing for cable protection of the following sizes including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed.
(a) 50 mm dia
(b) 40 mm dia
Supply and fix in repairs clamp made up of GI strip 25 x 3 mm thick to fix in the RCC/PCC pole for tying of street light connection cable of required length / size from bottom to top of the LT pole incl necessary GI nut, bolt and washers complete all as directed.
M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed by Engr in charge.
Supply and fix in repairs of LED Floodlight luminaire 240 watts capacity with secondary optics made in pressure die cast housing and heat sik in aluminium extrusion and IP66 Protection fixed in the AOL bracket of High mast light fittings all as specified and as directed. (Make : Bajaj Cat No BARFEG 240W LED or equivalent in Philips / CG)
Supply and fix in repairs of LED Floodlight luminaire 200 watts capacity with secondary optics made in pressure die cast housing and heat sik in aluminium extrusion and IP66 Protection fixed in the AOL bracket of High mast light fittings all as specified and as directed. (Make : Bajaj Cat No BARFEG 200W LED or equivalent in Philips / CG)
S & F in repairs HT / LT MS cable route indicator 5" to 6" dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.02 cum in each at base buried under the ground incl necessary earth work complete all as directed.
Demolition of old PCC of any descrption from site M & L new PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for fdn in any description with one side trawal finishes.
M/S Ghulam Hussain Lone
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .