Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹49.1 L+₹1.6 L (3.40%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹52.7 L+₹5.2 L (11.0%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹54.0 L+₹6.6 L (13.9%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹57.3 L+₹9.8 L (20.7%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/s Pooja Enterprises L4 | Ravi Enterprises L5 | bansal construction L1 | A. R. ELECTRICALS L2 | Kathir Marketing Services L7 | ICON AGENCIES L6 | DELTA ELECTRICALS L8 | Allied Trading Company L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply and fix in repair for aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed:- | |||||||||||
| 1.01 | (i) 06 Sqmm | 15 | Each | 20 ₹300 | 21 ₹315 | 18 ₹270 | 16 ₹240 Lowest | 20 ₹300 | 30 ₹450 | 28 ₹420 | 22 ₹330 |
| 1.02 | (ii) 10 Sqmm | 20 | Each | 21 ₹420 | 25 ₹500 | 22 ₹440 | 20 ₹400 Lowest | 22 ₹440 | 40 ₹800 | 35 ₹700 | 23 ₹460 |
| 1.03 | (iii) 16 Sqmm | 31 | Each | 23 ₹713 Lowest | 30 ₹930 | 26 ₹806 | 25 ₹775 | 24 ₹744 | 50 ₹1,550 | 45 ₹1,395 | 28 ₹868 |
| 1.04 | (iv) 25 Sqmm | 24 | Each | 25 ₹600 Lowest | 35 ₹840 | 30 ₹720 | 28 ₹672 | 28 ₹672 | 60 ₹1,440 | 50 ₹1,200 | 32 ₹768 |
| 1.05 | (v) 35 Sqmm | 22 | Each | 28 ₹616 Lowest | 40 ₹880 | 35 ₹770 | 30 ₹660 | 32 ₹704 | 62 ₹1,364 | 55 ₹1,210 | 36 ₹792 |
| 2.00 | Taking down of old UG Cable of any size/core and any type complete from trenches/cable duct/on wall/roof carefully, identifying for faults, dismantling unserviceable cable and saggregating serviceable cable for reuse all as specified and directed. | 1,165 | RM | 20 ₹23,300 | 45 ₹52,425 | 15 ₹17,475 Lowest | 18 ₹20,970 | 40 ₹46,600 | 63 ₹73,395 | 60 ₹69,900 | 18 ₹20,970 |
| 3.00Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: Earth work/HDPE pipe/straight through joints if required will be measured and paid separately.The rates should be includs in Cable lugs, Cable Gland and necessary insulation taping | |||||||||||
| 3.01 | (a) 4 Core 6 Sqmm | 145 | RM | 300 ₹43,500 | 314 ₹45,530 | 282 ₹40,890 Lowest | 288 ₹41,760 | 310 ₹44,950 | 350 ₹50,750 | 325 ₹47,125 | 291 ₹42,195 |
| 3.02 | (a) 4 Core 10 Sqmm | 145 | RM | 400 ₹58,000 | 432 ₹62,640 | 388 ₹56,260 Lowest | 398 ₹57,710 | 450 ₹65,250 | 440 ₹63,800 | 462 ₹66,990 | 398 ₹57,710 |
Tender Value
₹43.8 L
EMD Value
₹87,500
Closing Date
24 May 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Sri Vijaya Puram - 744 103
REPAIRS MAINT REPLACEMENT OF PERIMETER LIGHTS, STREET LIGHTS, SECURITY LIGHTS, POST TOP LANTERNS, GARDEN LIGHTS AND GATE LIGHTS AND ALLIED WORKS AT HQ 34 WEU AND MINNIEBAY AREA UNDER AGE EM-I OF GE MINNIEBAY
2025_MES_706504_1
8562/E8
Open Tender
Civil Works - Canal
Item Rate
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE Minnie Bau
₹87,500
Yes
23 Aug 2025
3 May 2025
26 May 2025
3 May 2025
24 May 2025
17 May 2025
Amount
Supply and fix in repair for aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed:-
(i) 06 Sqmm
(ii) 10 Sqmm
(iii) 16 Sqmm
(iv) 25 Sqmm
(v) 35 Sqmm
Taking down of old UG Cable of any size/core and any type complete from trenches/cable duct/on wall/roof carefully, identifying for faults, dismantling unserviceable cable and saggregating serviceable cable for reuse all as specified and directed.
Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: Earth work/HDPE pipe/straight through joints if required will be measured and paid separately.The rates should be includs in Cable lugs, Cable Gland and necessary insulation taping
(a) 4 Core 6 Sqmm
(a) 4 Core 10 Sqmm
(b) 4 Core 16 Sqmm
(c) 3.5 Core 25 Sqmm
(d) 3.5 Core 35 Sqmm
Supply & Laying in repair of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge Make : REX POLYEXTRUSION LTD or its equivalent as approved.
Relaying/ Rerouting old serviceable UG cable of size 10 to 25 Sqmm any core retrieved from item No above in trench/pipe/DWC pipes /on wall /cable duct with necessary saddles/clamps of suitable size complete all as directed. Note: Earth work, DWC pipe/GI pipe will be measured and paid separately.
S&F GI pipe of medium grade 40 mm dia all fitting fixture for fixing with wall and road crossing etc. complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge
All as per item No 7.00 here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
M&L for road cutting, removing of material , returning filling and pcc 1:2:4 for laying of LT UG cable /Galvanised Iron Pipe/DWC Pipe all as specified and as directed by Engineer-in -charge.
S & F in repair for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 25 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. .Make : DENSON / M Seal / RAYCHEM
Dismantling old RCC / rusted poles including PCC and supply & erect minimum 7 mtr height above GL / foundation made out of Hot dip Galvanized single section octogonal pole with foundation base plate of size 250x250x16 mm, foundation bolts 04 Nos of size 24 x 700/750 mm,with signle type arm bracket 1500 mm long, the pole shaft shall be tapered with single longitudinal welding and door opening for cable with 01 No MCB SP 6 Amp and 32 Amp connector and 03 run of 1.5 sqmm PVC wire for connecting street light fitting from MB complete all as specified and as directed by Engineer-in -charge. Note : Earth work, cement concrete in foundation, coping etc will be measured and paid seperately under relevant item.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted/ unserviceable cross arms.
Reinforced cement concrete (design mix) Foundations M-30 Grade, including rafts, footings, foundation beams, plinth beams, bases for columns, etc,basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr in charge.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
M&L for TMT bars from but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for foundation work complete all as specified and as directed by Engr in charge.
M&L for fixing in repair bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair of GI clamp made out of 50x6 mm flat iron of suitable size for steel tabular poles all as specified and directed by Engineer-in-charge.
Supply & fixing IP 65/66 thermoplastic-polycarbonate cable junction box of size 205X255X112mm with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of Two nos of GI calmp of size 25X3 mm including 40Amps connector, lugs and equivalent MCB complete all as directed.
Supply & fixing IP 65/66 thermoplastic-polycarbonate cable junction box of size 130X180X77mm with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of Two nos of GI calmp of size 25X3 mm including 40Amps connector, lugs and equivalent MCB complete all as directed.
S&F in replacement of LED street light Warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 90 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with 3000k-4000K, THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 8400 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 70 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with 3000K-4000K THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 7200 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 60 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with 3000K-4000K, THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 5400 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 45 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with 3000K, THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light warm white fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 3000 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 25 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with 3000K THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 90 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 8400 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 70 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 7200 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 60 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 5400 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 45 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 3000 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 25 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge Notes for Item Nos:-23.00 to 32.00: (a) GI pipe bracket if required shall be measured and paid separately
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type), IP 54 with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
Material and labour for painting to Steel tublar pole 9 m long with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal and lettering the pole details with adhesive sticker of dia 125 mm with white letters (indicating pole No/location code) on blue background blackground etc complete all as specified and as directed.
M&L for preparation of old painted surfaces of 9 m long RCC poles incl removing oily/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.0 mtr height including applying a coat of white distamper on pole, pole coping and lettering the pole details with adhesive sticker of dia 125 mm with white letters (indicating pole No/location code) on blue background blackground
Material and labour for fixing in repair radium reflective, water proof adhesive sticker of width not less than 50 mm wrapped around the street light pole of approved colour by Engineer in Charge complete all as specified and as directed.
S&F in replacement energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 25 W with THD less than 10%.CRI>80,P.F>0.9,IK>08,black case aluminium including all necessary wiring LED bulb,clamps,nut and bolts mounting accessories etc and providing connection complete all as specified and as directed by Engineer in charge
S&F in replacement energy efficient LED Garden light fitting 360 degree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 10 W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
S&F in replacement energy efficient LED bollard fitting with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long 12W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
S&F in replacement energy efficient LED Gate light Warm White fitting with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long 40W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
Supply & fixing LED Strip RGB light of length not less than 20mtr including remote control of 24 keys for multifunctioning light pattern and having 60 LEDs per mtr with total lumen output not less than 9000 lumens and suitable efficiency not less than 450 lumens per mtr min wattage 240 watt,with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl 2 set of strip connector and 1 driver, necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Helonix/Luker .
Supply & fixing LED Strip light of length not less than 5mtr including remote control/ WIFI for multifunctioning light pattern and lumen output not less than 2200 lumens and suitable wattage for efficiency not less than 25W ,with ingress protection IP 45 and SPD of capacity 10 KV etc incl 2 set of strip connector and 1 driver, necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Helonix/Luker .
S&F in replacement energy efficient LED Garden Spike light fitting with IP 65 protection high quality integerated LEDs assuring soothing multicolour of Red, Green, Blue, Ambar light all night long with output lumen not less than 360 lumens and suitable wattage not less than LED 7 W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 18000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 14400 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 24000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 30000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt) min wattage 250 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Supply and fix LED aviation lamp of minimum 10 watts with total lumen output not less than 1000 lumens and suitable wattage for efficiency not less than 100 lumens / watt made up of die-cast aluminum housing with red polycarbonate dome for better illumination, Integral driver, Ingress Protection : IP65, protection against short-circuit, protection against surge, wide operating input voltage range 100 – 270VAC complete all as specified and as directed by Engineer in Charge.
Supply & fixing in replacement of LED bay light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame, (with total lumen output not less than 9600 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 80 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker .
Supply & fixing in replacement of LED bay light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame, (with total lumen output not less than 14400 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 120 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker .
Supply fixing as in repair connection and testing of MCB SP 6-32Amps Amps Make : Legrand / L&T/Schiender.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note: a) Ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site. d) Spares required for repair to LED panel shall be measured and paid separately as "Supply only".
Supply only the following spares suitable for LED street/Flood light fittings of Make: Crompton/Phillips/C&S/Havells/Wipro/Henolix/Luker.
Electronic driver suitable for 90 to 120 W LED light fitting
Electronic driver suitable for 70 to 80 W LED light fitting
Electronic driver suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Surge protection device of capacity 5 KV suitable for LED light fitting
Supply only the following spares suitable for street/Gate Light/Garden Light fittings of Make: Crompton/Phillips//Havells//Wipro/Luker.
Lamp Holder suitable for 9-40 watt LED
LED Lamp 40 watt
LED Lamp 9 watt thread type/ Button Type
Supply and fix in repair MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.Make:-Legrand /schender/Hager/L& T
Dismantling LED light fitting of any existing make of capacity 90 to120 W ,strip opening the elctronic driver, LED panel , SPD , control wiring etc complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule itemsall as specified and as directed by Engineer-in -charge.
Dismantling LED light fitting of any existing make of capacity 70 to 80 W ,strip opening the elctronic driver, LED panel , SPD , control wiring etc complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items all as specified and as directed by Engineer-in -charge.
Dismantling LED light fitting of any existing make of capacity 40 to 60 W ,strip opening the elctronic driver, LED panel , SPD , control wiring etc complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items all as specified and as directed by Engineer-in -charge.Notes for item Nos.52 to 54:- The quoted rate is not inclusive of taking down and spares required shall be measured and paid separately
Dismantling the existing old rusted /unserviciable Steel / RCC poles of any type including all fitting fixture complete all as specified and as directed by Engineer-in -charge.
S&F in repair PVC copper cable insulated shealthed of size 1.5sqmm x 3 core complete all as specified and as directed by engineer in charge. Make- Havells or equivalent.
Supplying and laying on wall/ on pole of CPVC pipes outer diameter 20mm SDR 13.5 pipes & plain CPVC SDR 11 fittings complete all as specified and as directed including dismantling old one.
Suppy and laying in high mast lights Elastomer LT cables, PVC insulated, PVC sheathed, 2.5 Sqmm 3 core steel strip or wire armoured electric power cable with stranded copper conductor, 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: The rates should be include thimbles and connectors complete where ever required.
M & L for servicing of High Mast of less than 15 Mtrs height by lowering, checking, rectifying the defects, over hauling of winch drum assembly, motor including checking and replacing of gears, winch motor, wire ropes, trailing cable along with lugs, lubricating the moving mechanism and raising the high mast upto its height complete all as specified and as directed by Engineer in Charge. Note: The items gears, winch motor, wire ropes and trailing cable will be measured and paid separetely under relevant item.
Supply and fixing as in repair of Service wire Al Conductor Weather Proof 10 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Service wire Al Conductor Weather Proof 6 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
Supply only gear mechanism complete all as specified and directed by Engr-in-Charge.
Supply only stainless steel wire rope 6mm dia (7/19 construction).
M & L for dismantling the defective induction motor of capacity upto 1 HP any make/class of insulation from foundation bed, disconnecting all electric supply connections, duly coupled with pump/compressor, trasnporting to workshop removing burnt out widing from stator/rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE /NDE bearings, insulation materials, varnishing , heating, greasing of bearings etc complete, re-assembling, testing and commissioning of following capacity motors all as directed. Note : Terminal block, Bearings of motor if required will be measured & paid separately under relevant schedule items.
Supply and fix as in repair Digital Timer with Digital time switch ,contactor pre wired Distribution Board complete time lite 40A 3 Pole 415 V complete as specifed and directed by Engineer-in -charge.
Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr around each pole upto 1.0X1.0Mtr from each pole coping of pole complete all as specified and directed by Engineer-in -charge.
M&L for wiring of unserviciable timer panel box complete and replacement of existing size of copper wire and copper lugs and testing complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair contactors of capacity 40-63 A 3 Pole 415 V with 2NO+2NC complete all as specified and as directed by Engineer-in -charge. Make Legrand/L&T
Supply and fix as in repair NO/NC auxillary contacts of capacity 40A of 415 V complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair digital timer switch, current capacity 16A, with 1 changeover complete all as specified and as directed by Engineer-in -charge. Make Legrand/L&T /Indoasian
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth wire 4mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
A. R. ELECTRICALS (BID ID -3304007)
Allied Trading Company (BID ID -3303304)
M/s Pooja Enterprises (BID ID -3303224)
Ravi Enterprises (BID ID -3303859)
ICON AGENCIES (BID ID -3304128)
Kathir Marketing Services (BID ID -3304066)
DELTA ELECTRICALS (BID ID -3304050)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .