| 1 | L1₹24.9 LAccepted-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | ₹24.9 L | L1 | Accepted-Finance L1 Accepted |
| 2 | L2₹25.5 L+₹59,250 (2.38%)Rejected-Finance G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹25.5 L+₹59,250 (2.38%) | L2 | Rejected-Finance Rejected. |
| 3 | L3₹25.5 L+₹66,944 (2.69%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹25.5 L+₹66,944 (2.69%) | L3 | Rejected-Finance Rejected. |
| 4 | L4₹27.0 L+₹2.1 L (8.42%)Rejected-Finance | ₹27.0 L+₹2.1 L (8.42%) | L4 | Rejected-Finance Rejected. |
| 5 | Rejected-Technical 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | - | - | Rejected-Technical Not meeting NIT criteria. |
Tender Value
₹25.4 L
EMD Value
₹50,712
Closing Date
22 Feb 2024, 11:00 amClosed
AGM Engg Electrical
Electrcial dept,AAI,Belagavi airport-591124
SITC of Split, Tower AC units in Terminal Building, Offices, CCRs, KSPO, Dog Kennel, etc. and SITC of Water Coolers in Terminal Building at Belagavi Airport
2024_AAI_185262_1
SITC of Split, Tower AC units in TB,Technical Bloc
Open Tender
Electrical Works
Item Rate
90 days
Belagavi airport
Please refer tender document
14 documents required · 14 mandatory
₹1,180
₹50,712
8 Apr 2024
9 Feb 2024
23 Feb 2024
9 Feb 2024
22 Feb 2024
9 Feb 2024
9 Feb 2024 - 15 Feb 2024
Amount
Supply of 1 ton split ac,230v,50Hz single phase,5 star inverter, minimum ISEER 5, with refrigerant R32 including soft Copper refrigerant piping of required sizes for gas (suction) & liquid, with Armaflex insulation (upto 3m free supplied by the OEM)with 5 years on PCB and 10 years warranty on compressor including remote and batteries to the suitable location as decided by the engineer in charge.(Bluestar,model:IA512TNU or Daikin, Model:FTKM35 or equivalent)
Supply of 1.5 ton split ac,230v,50Hzsingle phase,5 star inverter minimum ISEER 5,with refrigerant R32 including soft Copper refrigerant piping of required sizes for gas (suction) & liquid, with Armaflex insulation (upto 3m free supplied by the OEM)with 5 years on PCB and 10 years warranty on compressor including remote and batteries to the suitable location as decided by the engineer in charge.(Bluestar,model:IA518TNU or Daikin,model:FTKM50 or equivalent)
Supply of 1.8/2 ton split ac,230v,50Hzsingle phase,5 star inverter,minimum ISEER 5, with refrigerant R32 including soft Copper refrigerant piping of required sizes for gas (suction) & liquid, with Armaflex insulation(upto 3m free supplied by the OEM) with 5 years on PCB and 10 years warranty on compressor including remote and batteries to the suitable location as decided by the engineer in charge.(Bluestar,model:IC524DNU or Daikin,Model:FTKM60 or equivalent)
Supply of 3.8/4 ton,3phase ,415v,50Hz,minimum ISEER 2.5,Non inverter with minimum 1 year warranty on compressor, floor standing with refrigerant R410 with remote,etc all accessories to the suitable location as decided by the engineer in charge.(Blustar,model:VC148GBTUR3 or equivalent)
Supply of water cooler stainless steel tank 304grade ,cold 30lts(minimum),normal 30lts(minimum),hot 2lts minimum with 7 stage purification of stages Prefilteration,precarbon filter,Post filtration,RO,UV,post carbon filter,etc complete as required .(Make :Conway,Model:125HC or acquetta ,model:NHC 250 or equivalent)
Supply of 3.5 X 35 sq mm cable,Al cable XLPE insulated 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.
Installation, Testing and Commissioning of Split AC of various capacities of 1/1.5/1.8/2.02 TR.
Installation, Testing and Commissioning of Tower AC of various capacities of 2.4/3.3/3.8/4.6 TR.
Installation, Testing and Commissioning of old Tower AC 3.3/3.8/4.6 TR units dismantled from other sites
Uninstallation of old split ac including outdoor,retracting of copper pipe line and drain pipe and shifting the same to the store as decided by the Engineer in charge.
Uninstallation of old tower ac including outdoor,retracting of copper pipe line and drain pipe and shifting the same to the store as decided by the Engineer in charge.
Supply and laying of of Control cabling and remote cable with copper conductor min. 4 core x 2.5 sq.mm. cable with end termination for Indoor units.
SITC of timer units for the ac units in UPS room and battery room of GLF, tower CCR units complete as required.
Supply and fixing of stand for ODU /Table L Type including drilling of wall, fasteners,nut,bolts complete as required.
Core cutting of the wall for ac units for the movement of Copper refrigerant piping of required sizes for gas (suction) & liquid, with Armaflex insulation and connecting the 25/32 mm dia for branch connection drain pipe from indoor to outdoor as per the location as decided by Engineer in charge.
Supplying and fixing of MS fabrication stands for tower ac with powder coating complete as required.
Soft Copper refrigerant piping of 1/4 sizes for gas (suction) & liquid, with Nitrile Rubber insulation.
Soft Copper refrigerant piping of 1/2 sizes for gas (suction) & liquid, with Nitrile Rubber insulation.
Soft Copper refrigerant piping of 3/8 sizes for gas (suction) & liquid, with Nitrile Rubber insulation.
Soft Copper refrigerant piping of 5/8 sizes for gas (suction) & liquid, with Nitrile Rubber insulation.
19mm dia Drain pipe with required size insulation
25mm dia Drain pipe with required size insulation
32 mm dia for branch connection with required size insulation
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following sizes directe in ground including excavation and refilling the trench etc as requried, but exculding sand cushioning and protective covering. Upto 35 sq. meters
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. meters
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. meters
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required(size 3 X 35 sq. mm (28))
Supplying and fixing following 6 way, Double door , single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following 12 way, Double door , single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following 6 way (8 + 18), Double door , vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 40A double pole, 240 volts, mcb in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 32A TP mcb in the existing DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, 63A,10KA MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of Four pole, (three phases and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 20 A, 240 volts,SPN Industrial type, socket outlet, with 2 pole and earth, metel enclosed plug top alongwith 20 A '' C'' curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metel cover for the socket out let and complete with conection, testing and commissioning etc. as required
Supplying and fixing 32 A,TP&N enclosure with 3 pole and Earth Metal Plug & Socket for Incorporating TP MCB Industrial type, alongwith 32 A '' C'' curve, , in sheet steel enclosure, on surface or in recess, with chained metel cover for the socket out let and complete with conection, testing and commissioning etc. as required
wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper cunductor,single core cable in surface/recessed midium class PVC conduit as required (2X4 sq.mm +1 X 4 sq.mm earth wire)
Suplling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the exiting surface/recessed steel /PVC conduit as required (4 X 6 sq.Mm )
AQUATICS ENIGINEERS
Manish Electricals
COOL STAR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .