Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.0 L+₹25,153.60 (0.62%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.7 L+₹93,322.65 (2.29%)Rejected-Finance PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹43.4 L+₹2.6 L (6.43%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical No remark in CEJZ WLR report of QE Jun 2025 |
| Sl No | Description | Qty | Unit | Hitesh Construction L4 | Radha Enterprises L3 | GAR CONSTRUCTIONS L2 | ALAKNANDA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed by Engr-in-Charge. | 15 | Cum | 400 ₹6,000 | 200 ₹3,000 | 150 ₹2,250 Lowest | 150 ₹2,250 Lowest |
| 2.00 | Demolition of cement concrete (un-renforced) in ground floor and paving n' exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified& directed by Engr-in-Charge. | 14 | Cum | 500 ₹7,000 | 250 ₹3,500 | 150 ₹2,100 Lowest | 200 ₹2,800 |
| 3.00 | Dismantling Asbestos Cement Corrugated or Semicorrugated in Roof covering complete all as specified & directed. | 2,295 | Sqm | 11 ₹25,245 | 6 ₹13,770 | 5 ₹11,475 Lowest | 10 ₹22,950 |
| 4.00 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified & directed. | 945 | Sqm | 11 ₹10,395 | 9 ₹8,505 | 5 ₹4,725 Lowest | 10 ₹9,450 |
| 5.00 | Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq m each & removing to store complete all as specified & directed. | 12 | Each | 75 ₹900 | 70 ₹840 | 60 ₹720 Lowest | 100 ₹1,200 |
| 6.00 | Taking down Chowkatts or frames with shutters (without taking off shutters from the frame n. exc 1.5 sq. m each & removing to store complete all as specified & directed. | 4 | Each | 75 ₹300 | 70 ₹280 Lowest | 90 ₹360 | 200 ₹800 |
| 7.00 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified & directed. | 70 | Sqm | 22 ₹1,540 | 25 ₹1,750 | 10 ₹700 Lowest | 25 ₹1,750 |
| 8.00 | Taking down cement plaster any description on brick or stone any description complete all as specified & directed by Engr-in-Charge. | 500 | Sqm | 22 ₹11,000 | 15 ₹7,500 | 10 ₹5,000 Lowest | 20 ₹10,000 |
| 9.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. | 6 | Per quintal | 500 ₹3,000 | 500 ₹3,000 | 150 ₹900 Lowest | 700 ₹4,200 |
| 10.00 | Dismantling of 75mm/110mm bore PVC(SWR) drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed. | 44 | RM | 10 ₹440 Lowest | 10 ₹440 Lowest | 20 ₹880 | 15 ₹660 |
Tender Value
₹48.4 L
EMD Value
₹97,000
Closing Date
21 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
Alwar
SPL REPAIR TO BLDG NO P-98, P-107 OF INF BDE CAMP AND SPL REPAIR TO ROOF OF BLDG NO P-103, P-104, P-98, P-97, P-102, P-256, P-257, T-8DH, T-10A OF INF BDE AND GE ALWAR AT ITARANA MIL STN ALWAR
2025_MES_732462_1
8459/E8
Open Tender
Civil Works
Item Rate
180 days
GE Alwar
As per NIT
6 documents required · 6 mandatory
₹500
GE Alwar
₹97,000
Yes
12 Jan 2026
24 Sept 2025
23 Oct 2025
24 Sept 2025
21 Oct 2025
14 Oct 2025
24 Sept 2025 - 13 Oct 2025
Amount
Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed by Engr-in-Charge.
Demolition of cement concrete (un-renforced) in ground floor and paving n' exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified& directed by Engr-in-Charge.
Dismantling Asbestos Cement Corrugated or Semicorrugated in Roof covering complete all as specified & directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified & directed.
Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq m each & removing to store complete all as specified & directed.
Taking down Chowkatts or frames with shutters (without taking off shutters from the frame n. exc 1.5 sq. m each & removing to store complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified & directed.
Taking down cement plaster any description on brick or stone any description complete all as specified & directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed.
Dismantling of 75mm/110mm bore PVC(SWR) drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.
M&L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:4 complete all as specified & as directed.
Extra over stone walling for hammer dressing to face stone and dressing of face, beds and joints as specified of random rubble walling with maximum depression on face from straight edge held against the dressed surface n.exc 20mm complete all as specified & directed.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed.
S&F factory made solid PVC Moulded door shutter 28 to 30mm thick (Stiles) with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on front face & 2 mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and directed.
S&F powder coated anodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
S&F Powder coated anodized aluminium door shutters, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as handles 2 Nos in each door, hinges type B-21 100mm long (3 Nos), complete all as specified & as directed.
S&F for powder coated of any colour as approved anodised aluminium grill of approved pattern for windows/ ventilators/doors complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples or nails and screws complete all as specified and directed.
S&F Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane 5.5 mm in thickness complete all as specified& directed by Engr-in-Charge.
Cutting holes in brick/stone walls n. exc. Half brick built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and directed.
S&F in repairs stainless steel rod of 20 mm inner dia (in lengths as directed) including decorative finial at both ends and pair of stainless steel brackets fixed at both ends with rawl plug & steel screws on walls/beam, all as specified & as directed.
M&L for PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate), 25mm thick, as in floor complete all as specified & directed by Engr-in-Charge.
M & L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredmatch over 15mm thick screed bed in CM 1:6 complete all as specified & directed by Engr-In-Charge. Make - Kajaria, AGL, Johnson
M&L Vetrified Ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in vertical surfaces as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over incl 10 mm thick cement rendering in CM 1:4 complete all as specified & directed. Make - Kajaria, AGL, Johnson
M&L for light shade joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed of cement mortar 1:6 complete all as specified & directed. Make - Kajaria, AGL, Johnson
M&L Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified & directed by Engr-in-Charge.
M&L 75 mm thick PCC(1:3:6) type C2 (using 40 mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified& directed by Engr-in-Charge.
Demolition of Roofs, floors (other than ground floors), beams staircases, landing, chajjas, & similar suspended work Cement concrete (reinforced) complete all as specified and directed.
M&L RCC (nominal mix) type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L Rendring 10mm thick in CM 1:6 on brick work or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement all as specified.
M&L for rendering 15mm thick in CM 1:4 on brick or concrete wall surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proof compound paid seperatly) all as specified.
Supply only Integral waterproofing compound complete all as specified & directed.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primer chalk whiting complete all as specified and directed by Engineer-in-Charge.
Material and labour for prepration over new surface and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance exterior paint emulsion of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm complete all as specified & directed.
M&L for providing and applying minimum 1mm thick wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed.
Material and labour for complete removal of existing treatment from stone wall /plastered wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance, exterior emulsion paint of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm over 1mm thick wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed.
M&L for preparing newly plastered surfaces and applying two coats of Oil bound distemper on walls including 2mm thick wall putty complete all as specified and directed by Engineer-in-Charge.
M&L for complete removing of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salt, trading oil greasy spots etc on old decorated surfaces of wall and applying two coats of oil bound distemper of approved shade/tint and inclucluding 1 mm thick Birla white wall care putty. complete all as specified and as directed.
M&L for brooming down old decorated surfaces of walls, plastered or unplastered including cornices, plasters etc and applying one coats of white wash complete all as specified and as directed by Engr- in - Charge.
All as per description of serial item No.44.00 here-in-above but on ceiling surfaces complete all as specified & directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified.
Material and labour preparation of newly plastered/unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of old treated surfaces of walls, plastered or unplastered and applying one coat of cement base paint of approved shade/tint. complete all as specified and as directed by Engr- in - Charge.
M&L for brooming down old decorated surfaces of walls, plastered or unplastered including cornices, plasters etc and applying one coat of oil bound distemper of approved shade/tint complete all as specified and as directed by Engr- in - Charge.
M&L for brooming down old decorated surfaces of walls, plastered or unplastered including cornices, plasters etc and applying one coats of white wash complete all as specified and as directed by Engr- in - Charge.
Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified & directed by Engr-in-Charge.
M&L screed laid 15mm thick in CM 1:4 with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified & directed by Engr-in-Charge.
M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces over bituminious primer complete all as specified & directed by Engr-in-Charge.
M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven reinforcement/mat (center core) with thermal insulation laid by toarch application method with overlaps 100mm on length side and 100mm on the width side as per manufacture,s instructions with fabric (wt not less than 150 gms/sqm) on primed surface including two coat of refelective silver aluminium paint over APP membrane complete all as specified & directed.
M&L For False Ceiling Complete With Armgyp-FB ceiling Tiles of Size 595x595,9mm thick (as approved by GE) fixed with and including galvanised iron Powder coated inverted 'Tee" or "L" section (Concealed GI frame Work) Suspended From Ceiling with provision of Galvanised wire 4mm dia and wall tapping screws including butterfly clips,hold down clips for fixing the board to frame complete all as per manufacturer's instruction, complete all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Fixed with self tapping screws including fixing of wind tie with screwing bolt for roof sheet complete all as specified & directed by Engr-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
S&F for steel work in tubular section for purlin/rafters etc including special shaped washer etc. complete using induction butt welded tubes conforming to I.S. 1161-1998 grade St- 240 complete all as specified & directed.
M&L for roof truses (framed), trussed, purlins, cranes gantries, rail and fastening and heavy bracket framing (Beam, tee, angle , channel or flat section) Fe 410-W (Gde-E250) quality A including distance pieces, cleats, bracket, etc complete all as specified & directed.
M&L for plate (plain or chequred channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachement complete all as specified & directed..
S&F for preparation of new steel surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat over red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces over 10 cm in width or girth and applying one coat of synthetic enamel paint on old painted surfaces, complete all as specified and as directed by Engr- in - Charge.
M&L Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in coping of brick masonry wall chajja including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified& directed by Engr-in-Charge.
M&L for Rough cast plaster on exterior walls applying the under coat of cement and sand mortar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even .The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified and directed by Engineer in Charge.
Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified & directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) bends any radius 110 mm bore complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl 110mm complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR),110mm junction single, (Single T) equal or unequal complete all as specified & directed by Engr-in-Charge.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls complete all as specified & directed.
S&F PVC (SWR) bends 75mm dia any radius complete all as specified & directed.
S&F PVC (SWR) junction single(Single T) equal or unequal 75mm dia complete all as specified & directed.
M&L for complete removing of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salt, trading oil greasy spots etc on old decorated surfaces of wall and applying two coats of Texture emulsion paint of approved shade/tint over a coat of primer over and inclucluding 1 mm thick Birla white wall care putty complete all as specified and as directed.
Taking out existing roof treatment of any description including plaster cement concrete etc rubbing with water including 20mm thick cement plaster in CM 1:3 on roof slab mixed with WPC 3% by weight of cement including finishing fair and even all as specified and directed. Note :- WPC shall be measured and paid seperately.
M&L water proofing treatement to RCC roof slab including parapet comprising of following course of treatement/specified from bottom to top (a) (i) The surface shall be painted with one coat of cold applied bituminous primer conforming to IS:3384, @ 0.40 kg per sqmii)applied a coat of hot blown bitumen @ 1.20 kg per sqm over a coat of bituminous primer, conforming to IS:338(iii)) APP based polymeric membrane not less than 3 mm thick, weighing not less than 3.5 kg/sqm, reinforced with polyst non-woven fabric (weighing not less than 150gm/sq m) aed. It shall be laid by torch application ( two coat of heat resisting paint over App membrane all as specified and directed by Engineer -in-Chargre. Side overlaps shall be 75 mm and the ends shall be 100 mm and all overlaps and joints shall also be sealed by torch application. For parapets, membrane shall be taken to a height of min 60 cm and then inserted inside the parapet in a groove. The same shall be finished by a membrane flashing.(iii) Coved fillet in PCC(1:2:4) type B0 of radius 75mm shall be provided at the junctions of roof and parapet wall /mumty/ chimney/other vertical surfaces.
Taking down carefully copper/aluminium point wiring of any size (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified & directed.
M&L for concealed Point wiring for One Light point controlled by one, one way switch with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including Modular MS shunk sheet metal box with modular cover plate of required Module with brass counter shunk screws with washer complete all as specified & directed. Note - Quoted rate shall include cost of cutting chases in Stone/Brick Wall for inserting PVC Conduit and Cost of Modular Cover plate of required module and making good to the disturbed surfaces including plastering and painting to match with the existing colour.
All as per srl item No 78.00 but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches.
All as per srl item No 78.00 but for One 3 pin 5 amps switch socket outlet point on independent board.
All as per srl item No 78.00 but for One fan point controlled by one switch and regulator.
All as per srl item No 78.00 but for wiring with 4.0 sq.mm multistranded cable and earth wire with copper conductor of size 4.0 sq.mm for 15 amps power/geyser point.
Supply and fixing in repair Modular switch, one way 6 Amp, 1 module, piano type, 230/250 volts grade on top covers (catered in point wiring above).
All as per srl item No 83.00 but for Modular switch, one way 16 Amp, 1 module
Supply and fix in repair Modular socket outlet 2in1, 3pin 5A, 2 module multipurpose use, flush mounting type, 230/250 Volts grade on Top covers (catered in point wiring above).
All as per srl item No 85.00 but for Modular socket outlet 2in1, 3 pin 15 Amps flush type.
Supply and fix in repair ceiling rose surface bakelite two to three terminals/plate, polycarbonate, isolated body.
Supply and fixing in repair PVC Blanking Plates one way with internal lock complete all as specified & directed.
Supply and fix in repair Lamp holder, PVC/Polycarbonate type complete with lamp LED 9 Watt for Batten fitting with back plate and all fittings complete all as specified and directed by Engr-In-Charge
Supply and fixing in repair LED 36 Watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixtures in white finish suitable for low ceiling height, 3 in 1 , 3K,4K,6K with & including LED prewired and connecting up dismantling of old UNSV recessed mounted light Complete all as specofoed and as directed by Engr-In-Charge
Supply and fix LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffisure duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd <10 and PF>0.95 complete all as specified and directed. Make - Crompton Cat Part CIS-305-40-57-SL-DP-NWH, Philips Cat part BN308C LED20S-6500 L120 PSU WH, Havells Cat Part STOUTPLUS600BS20WLED840SPCWH
Supply and fix Surface mounted COB LED fixture of 18 Watt with pressure die cast aluminium housing heat sink and clear PC as a Cover in white coated powder finish with integrated electronic LED driver and prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 18 watt . it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd <10 and PF>0.95 complete all as specified and directed. Make/Model : Crysta Deco Surf COB 18 W 6K Chrome W, Cat Part No.LHEEBGPGUE1W018 in Havells
Supply and fixing LED light fitting as building security lights of 35 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover, incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge.
Supply and hanging /fixing aesthetically designed BLDC ceiling fan with soothing LED Indication 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 26W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan including taking down old ceiling fan complete all as specified and as directed by Engineer-in-charge. Make/Model : Orient-Ecotech Prime CX 5 Star/ Havells-Epic Pro BLDC FHCPP5SGRY48/Bajaj- Nex Glyde A-60. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Old ceiling fan shall be deposited in AGE E/M store yard for further disposal.
Supply and fixing heavy duty exhaust fan with copper winding motor 100 Watt Capacity, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers mounted in suitable opening arrangement with louvers shutters suitable for operation on 230 Volt Single Phase 50 Cycle per second, AC Supply and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 1.0 Sqmm drawn in flexible PVC conduit and fixed by using 4 Nos 200 mm long 12 mm dia bolts nuts and washers grouted in wall in CM (1:3) complete all as specified and as directed by Engineer-in-charge and deposit the existing exhaust fans to AGE E/M Store yard for further disposal.
Supply and fix Wall Mounted fan , copper winding motor and accessories 230V 450 mm sweep complete all as specified and directed by engineer-in-charge.
S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar, 8 Way, 230 Volts and including taking down old U/S DB ,SPN,8 way complete all as specified & directed.
Supply and fix in repair Vertical TPN DB 4 way suitable for Double Pole outgoing MCB-40 Amp-04 Nos with incoming 100 Amps, 16 KA, MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified & directed.
Supply and fixing in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6-32 Amp poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge.
All as per srl item No 99.00 but for SPN 40-63 Amps
S&F in repair Modular AC box with a two pin and earth plug and socket complete with 01 No. double pole MCB 32 Amps & including taking down old U/S enclosure complete all as specified & directed .
Material & Labour for Sub Main Wiring in repair with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed.
Supply and lay in repairs and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm 3.5 Core complete all as specified & directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
All as per srl item No 104.00 but for 50 Sqmm 3.5 Core
All as per srl item No 104.00 but for 35 Sqmm 3.5 Core.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed
Supply and spreading, levelling river sand in trenches for cables cushioning on top and bottom of cable all as specifede and directed.
M&L brick protection with sub class'B' brick laid flat across the cable complete all as specified and directed.
M&L for boring under roads for crossing of UG Cables complete all as specifie and directed by Engr-In-Charge.
Supply and fix GI Pipe light grade of size 40 mm laid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge
Supply and fixing in repair of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviciable pipe of the size 25 mm bore complete all as specified & directed. Note :-Excavation and Earth work will be measured and paid separately
Supply and fixing Split type AC 1.5 ton single phase 50 Hz complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. glass wool, plywood, moulded thermocoal etc complete with steel bracket for condensing unit and copper cable of suitable size for making electric connections including necessary PCC in 1:2:4 Type B-I, using 20mm graded crushed stone aggregates as in founation, Platform, form work and angle iron work, steel frame made with angle iron size complete all as specified & directed. Make : Voltas/LG/Carreir/Blue Star/LLOYD Note :- The quoted rated shall be deemed to inclusive of supply and fixing set of bracket including nuts and bolts for outdoor unit complete.
Supply and fixing Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with working input voltage stabilized at 230 V with accuracy of ± 2.5% of capacity 5 KVA complete all as specified & directed.
Supply & install, testing & commissioning LT control panel compartmental type,Lockable fabrication made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement with the following :- (a) Al bus bar 300 Amp Cap- 1 Set ( Set of 4 strips) (b) MCCB 250 Amp 415V TPN 36 KA- 1 No (incoming) (c) MCCB 160 Amp,4 Pole, 25 KA with spreader links - 1 Nos(Outgoing) (d) MCCB 125 Amp,4 Pole,16 KA with spreader links - 1 Nos(Outgoing) (e) MCCB 63 Amp,4 Pole,16 KA with spreader links - 2 Nos(Outgoing) (f) Indicating fuse LED type R,Y,B - 3 Nos (g) On Load Change Over Switch 250 Amps - 01 Nos
GAR CONSTRUCTIONS (BID ID -3461767)
Radha Enterprises (BID ID -3459838)
Hitesh Construction (BID ID -3456439)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Tender8459.pdf
Tender Documents • 0.97 MB
BOQ_820112.xls
BOQ • 1.50 MB
Amendment01.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .