Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹58.2 L+₹10.4 L (21.7%)Rejected-Finance DEEDAR MARKET ROOM NO 16 POLICE BAZAR SHILLONG 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | L2 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 3 | L3₹58.9 L+₹11.1 L (23.3%)Rejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L3 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | R K CONSTRUCTION L1 | TN CONSTRUCTION L2 | S K Construction L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down chowkat or frame exc 1.5 Sqm but n.exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. | 12 | Each | 200 ₹2,400 Lowest | 300 ₹3,600 | 200 ₹2,400 Lowest |
| 2.00 | Taking down chowkats or frames n. exc 1.50 Sqm each with shutters (without taking off shutter from the frames) complete all as specified and as directed. | 24 | Each | 200 ₹4,800 Lowest | 300 ₹7,200 | 200 ₹4,800 Lowest |
| 3.00 | Taking down shutters of any description nexc 1.0 Sqm reach complete all as specified and as directed. | 8 | Per leaf | 150 ₹1,200 Lowest | 200 ₹1,600 | 230 ₹1,840 |
| 4.00 | Taking down shutters of any description nexc 1.0 Sqm refixing in same opening ccomplete all as specified and as directed. | 4 | Per leaf | 350 ₹1,400 | 200 ₹800 Lowest | 230 ₹920 |
| 5.00 | Taking down shutters of any description exc 1.0 Sqm and nexc 2 sqm refixing in same opening complete all as specified and as directed. | 4 | Per leaf | 350 ₹1,400 | 200 ₹800 Lowest | 230 ₹920 |
| 6.00 | Demolition of Brickwork/solid concrete block work built in Cement mortar complete all as specified and as directed. | 7.5 | Cum | 500 ₹3,750 Lowest | 500 ₹3,750 Lowest | 700 ₹5,250 |
| 7.00 | Dismantling unframed wooden work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. | 75 | Rm | 5 ₹375 Lowest | 10 ₹750 | 25 ₹1,875 |
| 8.00 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed. | 14.4 | Cum | 400 ₹5,760 Lowest | 900 ₹12,960 | 800 ₹11,520 |
| 9.00 | Demolition of reinforced cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed. | 0.48 | Cum | 500 ₹240 Lowest | 1,000 ₹480 | 850 ₹408 |
| 10.00 | Dismantling plain or corrugated steel sheeting, any guage, thickness incl Nainital, similar pattern as in roof coverings. complete all as specified and directed by Engr-in-Charge. | 51 | Sqm | 10 ₹510 Lowest | 50 ₹2,550 | 40 ₹2,040 |
Tender Value
₹49.1 L
EMD Value
₹98,140
Closing Date
3 Sept 2025, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG PIN 793002
SPL REPAIR TO OR MARRIED ACCN BLOCK NO. LM-43 (1-4) OF 17 JAT AT SHILLONG CANTT AND PROVN OF 01 X STORE ROOM FOR CQMH STORES AT 101 AREA SIG COY AND PROVN OF 200 MTR INTERLOCKING PARTHWAY ALONGWITH PERIMETER FENCE ROAD AROUND THE PT GROUND OF 17 JAT
2025_MES_724074_1
GE/SHL/TOKEN-62 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE SHILLONG
₹98,140
Yes
17 Oct 2025
1 Aug 2025
4 Sept 2025
1 Aug 2025
3 Sept 2025
15 Aug 2025
Amount
Taking down chowkat or frame exc 1.5 Sqm but n.exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed.
Taking down chowkats or frames n. exc 1.50 Sqm each with shutters (without taking off shutter from the frames) complete all as specified and as directed.
Taking down shutters of any description nexc 1.0 Sqm reach complete all as specified and as directed.
Taking down shutters of any description nexc 1.0 Sqm refixing in same opening ccomplete all as specified and as directed.
Taking down shutters of any description exc 1.0 Sqm and nexc 2 sqm refixing in same opening complete all as specified and as directed.
Demolition of Brickwork/solid concrete block work built in Cement mortar complete all as specified and as directed.
Dismantling unframed wooden work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any guage, thickness incl Nainital, similar pattern as in roof coverings. complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth , wall tiling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors aprons laid in any mortar complete all as specified and as directed.
Dismantling wall and ceilling boards of any description including cover fillets complete all as specified and as directed.
Dismantling boarding any description fixed in any position with nails complete all as specified and directed.
Dismantling of timber scantling 40 sqcm over in section in any position (unframed work) complete all as specified and as directed.
RCC nominal mix 1:2:4 type B-1 (using 20mm graded aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in kitchen shelves and the like including necessary form work complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to Fe 500 or Fe-550 as in steel reinforcement for concrete complete all as specified and directed.
S&F Gl frame work for snapgrid false ceiling comprising of Gl perimeter channnel 0.55 mm thick with Main T- flange of 25 mm and web of 30 mm fixed to surrounding wall angle with flange and web 25 mm each , Cross T with flange 25 mm and web 25 mm fixed to main T, Main T is suspended from soffit @ 1200 mmm c/c using GI wire of 4mm thickness GI frame will be 60 x 60 cm to recieve E-board ceiling complete all as specified and as directed .
M&L 4mm thick E Board 600x600 mm prepainted fibre boards ceiling designer/decorative type with different designs as approved by the Engr-in-charge fixed or laid in ceiling timber /GI/ aluminium frame work in ceiling flat or sloping complete all as per manufacturer instruction complete all as specified and as directed.
M&L for 2nd class hard wood plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads , sectional area exc. 13 and n.exc. 25 sqcm complete all as specified and as directed.
S&F 2nd class SW boarding 20mm thick fixed with nails in eaves board plained one side with butt joint complete all as directed.
M&L 2nd class hard wood in scantling clean sawn timber fixed all as specified and directed.
M&L 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid ,rounded or chamfered ,put together with glue pinned at joints , supplied and fixed complete all as specified and as directed.
S&F 30 mm thk Flush door shutters solid core construction with block board core and plywood face pannels , commercial type on both sides complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood skelton shutters open rebated and prepare to receive glass, gauze, etc complete all as specified and directed
S&F stainless steel wire cloth,0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F 18/19 mm thick block boards grade 1, exterior grade, commercial type fixed with screws to timber frame complete all as specified and as directed
S&F 12 mm thick block boards grade 1, exterior grade, commercial type fixed with screws to timber frame complete all as specified and as directed.
S&F 0.90 mm thick decorative laminates type 1 of surface finish color and pattern as approved fixed with approved adhesive as per manufactures instruction complete all as specified and directed.
S&F butt hinges 75 mm medium weight, stainless steel, and fixed complete all as specified and as directed.
S&F Butt hinges 125mm, medium weight, stainless steel, and fixed complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolts of extruded section and fixed complete 150 mm long complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolts of extruded section and fixed complete 100 mm long complete all as specified and as directed.
S&F extruded aluminium alloy handles fabricated type anodised of size 150 mm complete all as specified and as directed.
S&F extruded aluminium alloy handles fabricated type anodised of size 125 mm complete all as specified and as directed.
S&F Magnet catches for cupboard shutter, brass body and striking plate including letting in all as specified and as directed.
S&F 30mm width of flaps (When open in mm) continuous (piano) hinges, mild steel , bright finish or electro galvanised complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp staple (bolt type) 300mm size and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
S&F powder coated (powder coating min 50 micron) anodised two or three track sliding type window and ventilator shutters or side hung / without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete as specified
M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium frame n.exc 0.50 sqm complete all as specified and as directed.
M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed.
M&L for 4.80 mm thick frosted sheet glass quality and glazing fixed to aluminium frame n. exc 0.50 sqm complete all as specified and as directed.
M/L precast cement concrete block massonry with solid blocks exc 10 cm in width and settings in CM 1:6 type C1 1:3:6 (20mm graded aggregate) complete all as specified.
M/L precast cement concrete block massonry with solid blocks nexc 10 cm in width and settings in CM 1:4 type C1 1:3:6 (20mm graded aggregate) complete all as specified.
S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof covering / cladding including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, complete all as specified and directed by Engr-in-Charge.
S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof covering including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed by Engr-in-Charge.
M & L Glazed ceramic Coloured Tile 300x450x7mm/300x600x7 mm thick in Skirting, Dados, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Colour Cement to match laid over and including a backing coat of 10mm thick CM 1:4 screed, complete all as specified and as directed.
M&L for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) used as in sub base to recd floor tiles complete all as specified and directed
M&L for Non Skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile colour including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM (1:6). complete all as specified and directed.
M&L for non skid ceremic white tiles 7 to 8mm thick area of each tile exc 0.18 sqm but n exc 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified
M&L for 18/20mm thk granite slab (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and incl pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite over and including 20 mm thick cement screed bed in CM 1:4 complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking plateform, and other similar situation complete all as specified and as directed.
Taking down plastering on lathing (other than wire-netting, without removing lathing, in cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed.
M&L for rendering 10mm (cement plaster 1:6) thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing complete all as specified and as directed.
M&L for rendering 15mm (cement plaster 1:4) thick on the other side of lathing with approved Water proofing compound @ 3% by the weight of cement or as per manufacturers instructions complete all as specified and as directed.
Supply only Integral waterproofing compound
S&F for 20 mm dia harrison rails, stainless steel chromiun plated with fixing brackets stops , rollers etc all as directed and specified.
S&F for 20 mm dia brass chromium plated brackets all as directed and specified.
S&F solid PVC door frame of size 50 mmx 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as per specifiecation complete all as specified and as directed.
S/F Factory made solid panel PVC door shutter 30 mm thick (style) considering of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed togeather with solvent cement, fixing in the frame at site as per specification & drawing.
S&F Bib taps, cast copper alloy fancy type 15mm bore , screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F stainless steel gratings 100mm bore size fixed with cement motar complete all as specified .
S&F 125mm shower rose cast copper alloy, chromium plated, fancy type, with swivel joint fixed to 15 mm bore iron pipe complete all as specified and directed
S&F 15 mm bore brass CP basin mixer for mixing hot & cold water screwed down high pressure for iron pipe and fixed complete all as specified and as directed
S&F vitreous china wash down water closet pan (Pedestal Pattern) with P or S Trap white (excluding flushing cistern & flush pipe) incl connection to out going pipe and flushing pipe complete all as specified and as directed.
S&F plastic water closet seat cover, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed
S&F PVC valveless, 10 ltrs, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified.
S&F in repairs Vitreous china WHB, white, flat back, of size 550 x 400 mm including brackets, waste coupling 32mm, and waste Pipe, 32mm incl pedastal complete all as specified and directed.
M&L 75mm dia PVC(SWR)floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and as directed.
M&L for 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bends 110mm dia complete all as specified and as directed.
S&F PVC (SWR) bends 75mm dia complete all as specified and as directed
S&F PVC(SWR) 75mm dia vent cowls
S&F PVC Connections 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed.
Dismantling water tanks exc 250 ltrs but not exc 500 ltrs capacity , complete all as specified
Supply and fixing rotational moulded HDPE water storage tank ,double layer ,ISI marked (cylendrical vertical type with closed top) of capacity 500 ltrs in position incl float ball brass valves, high pressure, with polythene float and flynut complete , screwed for iron pipe or brass ferrule and fixed for iron pipe and fixed all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10cm in width or girth and treated with one coat of synthetic enamel paint complete all as specified and directed.
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F Stainless steel kitchen plate rack of size 31" X 30' X 10" made out of stainless steel sheet of 1.00 mm with all accessories including taking down old unservicable rack complete all as specified and as directed.
S&F brass chromium plated tubular towel rail 20mm dia D type 60 cm long between flanges complete all as specified and as directed.
Taking up or down steel tubing and disconnection, for 15mm bore of pipes complete all as specified and as directed.
Taking up or down steel tubing and disconnection, for 20mm bore of pipes complete all as specified and as directed.
Supply and Laying Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
All as per Item 86 above, but for 20mm dia (Bore).
S&F stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle 15mm dia complete all as specified and directed.
S&F cutting chases, pinning in concrete block workmaking good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth.
M&L 100mm thick cement concrete using (40mm graded aggregate) type D-2 (1:4:8) as in sub base complete all as specified and as directed.
M & L 75mm thick PCC 1:4:8 type D2 as in subfloors finished even and rough without using extra cement complete all as specified and as directed.
M & L sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L Machine pressed precast concrete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade complete all as specified.
M&L for 75 mm thick cement concrete 1:2:4, type B-2 (using 40mm graded agg) as in plinth protection finished even and smooth without using extra cement.(incl necessary joint filling with mixture of paving bitumen & sand in 1:3) complete all as specified and as directed.
S&F MS framed work such as grills, gratings, etc with ends of bars, shouldered and/ or riveted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk way, railing and framed work of water tanks and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
Complete removal existing treatment and applying 1mm thick of white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint complete all as specified and as directed.
M & L for preparation of new plastered/concrete surfaces of walls, providing 1 mm thick of white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint complete all as specified.
M&L for preparation of new steel surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat red oxide primer all as specified.
M&L for preparation of new or previously untreated surfaces of wood and wood based materials of any description not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primer all as specified and as directed.
M&L preparation surface of wood and wood based material new or old of any description and girth and treated with creosote oil complete.
M&L for preparation of new or previously untreated surfaces of wood and wood based materials description n exc 10cm width or girth and applying two coat of synthetic enamel paint (ordinary tint) over pink primer surfaces when unconnected with other painting or when painted in different tint complete all as specified and as directed.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by washing rubbing down and stopping of any external painted surfaces and priming with alkali resistant primer paint applying two coats of weather coat exterior paint with roller incl filling of holes and cracks with suitable material like cement or plaster of paris etc complete all as specified and as directed.
M&L for preparation of new plastered/concrete surfaces of walls and priming with alkali resistant primer paint applying two coats of weather coat exterior paint with roller etc complete all as specified and as directed.
Excavation in trenches n,exc 1.5m wide and n,exc 1.5m depth for foundation, etc, n exc 10 sqm on plan and n exc 1.5m depth and getting out in soft/loose soil complete all as specified.
Returning filling in including spreading levelling, watering and well ramming in layers n.exc 25cm thick in soils complete all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
M&L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling mass concrete all as specified and directed.
RCC (nominal mix) type B1 1:2:4 (using 20mm graded aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams, lintel beams , roof beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc. complete all as specified.
RCC (nominal mix) type B1 1:2:4 (using 20mm graded aggregates) as in columns, piers , posts etc. complete all as specified.
RCC (nominal mix) type B1 1:2:4 (using 20mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified.
RCC (nominal mix) type B1 1:2:4 (using 20mm graded aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Formwork to sides of concrete foundations, footings, bases of columns,and soffits (if any) of plinth beams; and similar work fair finished flat complete all as specified and as directed.
Formwork to sides of pillars, columns, posts, piers etc fair finished square , rectangular or polygonal complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc fair finished flat complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc fair finished flat complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to Fe 500 or Fe-550 as in steel reinforcement for concrete complete all as specified and directed.
All as item No 116 above but 5 mm dia and over up to 10mm dia of steel bars as in stirrups, spacers, rings etc complete all as specified and directed.
M & L for Block masonry with solid precast cement concrete blocks made out of cement concrete 1:3:6 type C-1, using 20mm graded stone aggregate, exc 10cm width and setting in cement mortar 1:6 complete all as specified by Engr-in-Charge.
M&L Rendering, 15 mm thick in CM 1:4, in two layers, first 5 mm thick with approved Water proofing compound @ 3% by the weight of cement or as per manufacturers instructions over a coat of 10 mm thick base coat finished even and smooth complete all as specified and as directed by Engineer-in-Charge. Note : WPC shall be measured and paid separately.
M&L for 10 mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including ceiling with finishing even & smooth without using extra cement complete all as specified by Engr-in-Charge.
M&L for 2 Coats of cement base paint over a coat of primer incl prepration of newly plastered surface on wall complete all as specified and directed.
M&L for preparation of new plaster /concrete surface of walls, and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed.
M & L for hardcore of broken brick/stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified
M&L for 100 mm thick cement concrete 1:4:8, type D-2 (using 40mm graded agg) as in sub base even and smooth without using extra cement complete all as specified and directed .
M&L for 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) used over sub base to recd tiles complete all as specified and directed
S&F double legged floor door stopper aluminium alloy with rubber etc complete all as specified and as directed.
S&F steel window with side hung shutters including projection as box type hinges with steel handles and peg stay with glazing bars including one shop coat of red oxide primer.
S & F Mild steel Hand Rails, half rounded , Angles, bars, flats drilled and countersunk for balusters running bars for doors , balustes, nosing to steps including embeding in concrete and screwing etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe 410-O 0r Fe 310-O
M&l For Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20 mm thick cement screed bed in CM 1:3 complete all as specified complete.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20 mm thick cement screed bed in CM 1:3 complete all as specified complete.
M&L for water proofing treatment to RCC roof slab, comprising with the following courses of treatment/specification from bottom to top:- (i) Roughening the concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified
M&L providing PCC 1:2:4 type B-1 using 20 mm graded stone agg as in sides , kerbs or mud stops, rounded or chamfered on edges of path etc. all as specified.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified.
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) used over sub base to recd tiles complete all as specified and directed
M&L for light shade vitrified tiles , 9 to 10mm thick (square / rectangular) polished, area of each tile n.exc 0.36 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm dia concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch.
Description all as per Srl item No. 138 here in before but for one bell point controled by one bell push .
Description all as per Srl item No. 138 here in before but for socket outlet point 5 Amp on same board.
Description all as per Srl item No. 138 here in before but for one light point controlled by two way switch.
Description all as per Srl item No.138 here in before but for socket outlet point 5 Amp on Independent board.
Description all as per Srl item No. 138 here in before but with 2.5 Sqmm cable for socket outlet point 5 Amp on Independent board.
Description all as per serial item No 138 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified.
Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified.
Supply and fixing Bell push, flush type, 5 amp 1 way 6 A module 230/250 volt with frame and cover complete , AC supply, ISI Marked, with cover plate complete all as specified and directed.
Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. (For Same Board only)
Supply and fix switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixing piano switch 2 way 6 A module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. Make : Cona , Plaza, Anchor .
Supply and fixing call bell ding dong, AC, 230 V, Single pole ISI marked all as specified and directed. Make- Havells/anchor/ Legrand.
Supply and fixing LED batten fittings 1x18 Watt complete pre wired fixed to wall with 2 nos PVC block of suitable size including taking down old unserviceable one. MAKE: surya,crompton or havells
Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S&F lamp holder, insulated body, with back plate for batten fitting complete. Make- Havells/anchor/Legrand.
Supply and fix ininverter LED bulb 12 Watt B22 base Color complete including taking down old unserviceable one all as directed.
Supply and fix ininverter LED bulb 20 Watt B22 base Color complete including taking down old unserviceable one all as directed.
S & F in replacement of LED / Bulk head Light fitting with lamp 1 x 9 watt including LED light driver, holder, LED lamp and connection up to ceiling rose with three core wire complete with necessary connection including taking down old unserviceable one
S & F Exhaust fan 230 volts , 250mm,plastic body including making all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall. MAKE: Crompton and Havells
Supply and fixing LED security Building light LED 25 Watt , pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete.
Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified.
Supply and fix in repairs MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
Supply and fix MCCB TPN, 240 Volts, 100 Amps, 10 kA rupturing capacity415 Volts complete all as specified and directed including taking down old one.
Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one.
Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's
M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
Taking down existing energy meter and refixing the same after completion on the original location all work all as directed by Engr-in-Charge
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc , of size 16 Sq.mm 4 core , confirming to IS specifications :-
Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of any dismeter in soft/loose soil and getting out complete all as specified and directed
Returning and filling including spreadking levelling watering and well ramming in layers not exc 25 cm thick soft/loose soil complete all as specified and directed
Removing excavated material at a distance n exc 50m and deposited where directed at a level not exc 1.5 above the starting point for soft/lose soil complete all as specified and directed
M & L for sand filing in treances for providing sand cushion for protection of UG cable complete all as specified and directed.
Supply and laying of sub class B bricks locally available alying perpendicular of UG cable complete all as specified and directed.
Supply and fixing modular switch 1 way 6 A module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed.
Supply and fixing modular sockets 6A 2/3 pin combined 2 module, with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
Supply and fixing modular switch 16A 1 module with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, c with cover plate omplete all as specified and directed.
Supply and fixing LED batten fittings 1x 20 Watt complete including LED light driver, holder, LED lamp and connection up to ceiling rose with three core wire fixed to wall with 2 nos PVC block of suitable size including taking down old unserviceable one .
Supply and fix in repairs LED lamp 7 Watt B22 base Color Temp 6500 K complete including taking down old unserviceable one all as directed. MAKE: surya,crompton or havells
Supply and fix/lay in tranches, on floors ,fix on wall/pole, passing through pipes, in air etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc , of size 6 Sq.mm 2 core , confirming to IS specification
TN CONSTRUCTION (BID ID -3413808)
S K Construction (BID ID -3407417)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .