Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAdmitted-Finance S NO 261 1 D SAI MIRACLE ROAD SHIVRAI NAGAR RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | ₹39.5 L | L1 | Admitted-Finance |
| 2 | L2₹40.1 LAdmitted-Finance | ₹40.1 L | L2 | Admitted-Finance |
| 3 | L3₹46.1 LAdmitted-Finance | ₹46.1 L | L3 | Admitted-Finance |
| 4 | L4₹46.9 LAdmitted-Finance | ₹46.9 L | L4 | Admitted-Finance |
| 5 | L5₹47.8 LAdmitted-Finance | ₹47.8 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | OM SAI ELECTRICALS L5 | Shine Enterprises L4 | S and G Constructions L3 | star freeze service L2 | ISHITARAJ ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Checking and attending electrical complaints for continuous electric supply like No light / Short circuit / non working fittings / fixtures /fan / exhaust fan / geyser including replacement of unserviceable parts such as switch, socket, holders, tube light and including carrying out the minor repair like fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.50 mtr length and maintenance work on all working days complete all as specified and as directed.
Note:
(i) Rates inclusive of all small items like screws , wire etc.
(ii) Contractors are advised to visit the sites before quoting their rates.
(iii) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor
(iv) Any nature of electrical complaint, the entire responsibilty of rectification lies with the contractor. | 650 | Each Job | 110 ₹71,500 | 105 ₹68,250 | 120 ₹78,000 | 100 ₹65,000 | 200 ₹1.3 L |
| 1.01(v) Contractor shall be penalised @ Rs. 2000/- per day per complaint, if he fails to attend the complaint within 12 hours. (vi) All serially numbered complaint docket will be provided by contractor and cost of docket included in the rate quoted for the items. (vii) All T&P, safety gadgets shall be provided by the contractor. (viii) Rep of the contractor shall receive complaints in morning 0900 hr and give feedback on daily basis to concerned JE E/M (ix) Payment to contractor released after submission of these complaints duly rectified within time and duly signed by contractor, JE, and Engineer-in-Charge in RAR/Final bill. (x) Contractor shall maintain the maintinance register showing all daily complaints recieved and shall maintain job cards for attending complaints. The signature of the user shall be obtained on the job card showing the material incorporated in the work after completion of the job with date. | ||||||||
| 2.00 | Supply and fix in repairs switch piano type single pole one way 5 Amps 230 V complete all as specified and directed by Engineer in charge. | 500 | Each | 55 ₹27,500 | 50 ₹25,000 | 50 ₹25,000 | 45 ₹22,500 | 35 ₹17,500 |
| 3.00 | Supply and fix in repairs Modular switch 1 way 6A, 1 module 230 V complete all as specified and directed by Engineer in charge. | 60 | Each | 110 ₹6,600 | 80 ₹4,800 | 90 ₹5,400 | 80 ₹4,800 | 80 ₹4,800 |
| 4.00 | Supply and fix in repairs switch piano SP two way 230 V complete all as specified and directed by Engineer in charge. | 30 | Each | 65 ₹1,950 | 70 ₹2,100 | 50 ₹1,500 | 45 ₹1,350 | 170 ₹5,100 |
| 5.00 | Supply and fix in repairs modular Switch socket outlet 3 pin 5 amp' flush type 230 V complete all as specified and directed | 35 | Each | 255 ₹8,925 | 250 ₹8,750 | 250 ₹8,750 | 210 ₹7,350 | 380 ₹13,300 |
| 6.00 | Supply and fix in repairs modular Switch socket outlet multi?purpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch 230 V complete all as specified and directed. | 60 | Each | 325 ₹19,500 | 300 ₹18,000 | 320 ₹19,200 | 300 ₹18,000 | 530 ₹31,800 |
| 7.00 | Supply and fix in repairs Swtich socket combination 2 in 1, 5A 3 Pin and 5A 2 pin combined flush type, 230 V ,complete all as specified and directed. | 200 | Each | 130 ₹26,000 | 100 ₹20,000 | 125 ₹25,000 | 115 ₹23,000 | 210 ₹42,000 |
| 8.00 | Supply and fix in repairs Modular type bell push single pole 6 Amps , 1 Module 230 V complete all as specified and directed. | 10 | Each | 130 ₹1,300 | 100 ₹1,000 | 125 ₹1,250 | 120 ₹1,200 | 155 ₹1,550 |
| 9.00 | Supply and fix in repairs bell push single pole 5 Amps, 230 V complete all as specified and directed. | 96 | Each | 55 ₹5,280 | 45 ₹4,320 | 45 ₹4,320 | 45 ₹4,320 | 90 ₹8,640 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Mar 2026, 6:00 pmClosed
SHRI JITENDRA KUMAR MEENA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8695/E8
2025_MES_733722_3
8695/E8
Open Tender
Electrical and Maintenance Works
210 days
VASCO GOA
Class D Category b i
9 documents required · 9 mandatory
₹500
GE (NW) VASCO
₹90,000
Yes
24 Mar 2026
24 Feb 2026
20 Mar 2026
24 Feb 2026
18 Mar 2026
4 Mar 2026
24 Feb 2026 - 3 Mar 2026
Checking and attending electrical complaints for continuous electric supply like No light / Short circuit / non working fittings / fixtures /fan / exhaust fan / geyser including replacement of unserviceable parts such as switch, socket, holders, tube light and including carrying out the minor repair like fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.50 mtr length and maintenance work on all working days complete all as specified and as directed. Note: (i) Rates inclusive of all small items like screws , wire etc. (ii) Contractors are advised to visit the sites before quoting their rates. (iii) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor (iv) Any nature of electrical complaint, the entire responsibilty of rectification lies with the contractor.
(v) Contractor shall be penalised @ Rs. 2000/- per day per complaint, if he fails to attend the complaint within 12 hours. (vi) All serially numbered complaint docket will be provided by contractor and cost of docket included in the rate quoted for the items. (vii) All T&P, safety gadgets shall be provided by the contractor. (viii) Rep of the contractor shall receive complaints in morning 0900 hr and give feedback on daily basis to concerned JE E/M (ix) Payment to contractor released after submission of these complaints duly rectified within time and duly signed by contractor, JE, and Engineer-in-Charge in RAR/Final bill. (x) Contractor shall maintain the maintinance register showing all daily complaints recieved and shall maintain job cards for attending complaints. The signature of the user shall be obtained on the job card showing the material incorporated in the work after completion of the job with date.
Supply and fix in repairs switch piano type single pole one way 5 Amps 230 V complete all as specified and directed by Engineer in charge.
Supply and fix in repairs Modular switch 1 way 6A, 1 module 230 V complete all as specified and directed by Engineer in charge.
Supply and fix in repairs switch piano SP two way 230 V complete all as specified and directed by Engineer in charge.
Supply and fix in repairs modular Switch socket outlet 3 pin 5 amp' flush type 230 V complete all as specified and directed
Supply and fix in repairs modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch 230 V complete all as specified and directed.
Supply and fix in repairs Swtich socket combination 2 in 1, 5A 3 Pin and 5A 2 pin combined flush type, 230 V ,complete all as specified and directed.
Supply and fix in repairs Modular type bell push single pole 6 Amps , 1 Module 230 V complete all as specified and directed.
Supply and fix in repairs bell push single pole 5 Amps, 230 V complete all as specified and directed.
Supply and fix in repair switch socket combination 2 in one 3 pin 5 A and 3 pin 15 A Combined flush type complete all as specified and directed.
Supply and fix in repairs switch piano flush button type single pole 15 Amps. 230 V complete all as specified and directed.
Supply and fix in repairs socket outlet flush type 2 in 1, 3 pin 5 and 15 Amp single pole, 230 V complete all as specified and directed.
Supply and fix in repairs Socket outlet 2 in 1, 3 pin, 5A single pole, 230 V complete all as specified and directed by Engineer in charge.
Supply and fix in repairs rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ ceiling, complete all as directed
Taking down unserviceable submain wiring Aluminium/ copper of any size/ core/type including earth continuity condutor on teak wood or conduit and removing the materialss/debris from site and making good the disturbed surfaces of wall etc to match with the original existing finish all as directed.
Supply and fix in repairs Submain wiring with 1100 volt grade PVC insulated unsheathed multistranded 02 run of 1.5 sqmm copper conductor cable confirming to IS 694 FRLS grade (for phase, neutral, with proper colour code) drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 01 run of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 1.5 sqmm and 01 run of 1.5 sqmm including 01 run of PVC casing caping shall be measured as one length compete all as specified and directed.
Supply and fix in repairs Submain wiring with 1100 volt grade PVC insulated unsheathed multistranded 02 run of 2.5 sqmm copper conductor cable confirming to IS 694 FRLS grade (for phase, neutral, with proper colour code) drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 01 run of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 2.5 sqmm and 01 run of 1.5 sqmm including 01 run of PVC casing caping shall be measured as one length compete all as specified and directed.
Supply and fix in repairs Submain wiring with 1100 volt grade PVC insulated unsheathed multistranded 02 run of 04 sqmm copper conductor cable confirming to IS 694 FRLS grade (for phase, neutral & earth continuity conductor, with proper colour code) drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision including provision of 01 run of 2.5 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 04 sqmm and 01 run of 2.5 sqmm including 01 run of PVC casing caping shall be measured as one length compete all as specified and directed.
Supply and fix in repairs Submain wiring with 1100 volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS grade (for phase, neutral, with proper colour code) drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 01 run of 4 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 4 sqmm including 01 run of PVC casing caping shall be measured as one length compete all as specified and directed.
Taking down unserviceable aluminium point wiring (light, fan, socket or power ) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed complete all as specified and directed .
M&L for Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed.
One light point controlled by one switch
One fan/ exhaust fan point controlled by one switch and regulator
One 3 pin socket, 5 Amps on the same board, with cables 1.5 sq. mm size
One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size
One light point controlled by two 2-way switches, with cables 1.5 sqmm.
One call bell controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm
Supply and fix in repairs for point wiring complete with FRLS 1100 Volts grade, two runs of 2.5 sqmm copper cable through PVC casing and capping with one run of 2.5 sqmm PVC insulated and unsheathed multistranded copper conductor cable as earth continuity wire connected to common earth dolly complete all as specified and directed
Supply and fix in repairs PVC ceiling rose, surface type, with three terminals complete all as sspecified and directed
Supply and fix in repairs Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed
Supply and fix in repairs PVC insulated body, angle / Straight lamp holder with back plate complete all as specified and directed
Supply and fix in repairs industrial metal clad socket, 3 pin, including 20 amp mcb SP and 3 pin Plug top, concealed on wall and making the surface good, matching with the existing wall complete all as specified and directed.
S & F in repairs Integrated Inverter LED batten tube light fitting type 1x 20 watt indoor type complete with lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours including all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: BAJAJ Cat part No:- 830592 or equivalent approved
S & F in repairs Inverter LED light fitting mirror type with high out put diffuser 2 feet , 10 watt 220 v AC with driver and LED tubelight including with lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: BAJAJ Cat part No: 830414 or equivalent approved.
Supply and fix in repair Inverter LED bulb of 9 Watt, lumen output 1000 Lumen, Backup upto 4 hours, B22, Make :- Bajaj Cat part NO:- 830328 or equivalent approved
Supply and fixing in repairs MCB Isolator DP 40 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed.
Supply and fixing in repairs MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs Isolator TPN 63 Amps 415 volts complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs MCCB 63-100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as sspecified and directed
Supply and fix in repairs hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of sizes 4"x4" , inclusing cutting for fixing switches and sockets complete all as sspecified and directed
Supply and fixing in repairs hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of sizes 8"x10", inclusing cutting for fixing switches and sockets complete all as sspecified and directed
Supply and fixing in repairs hylam sheets 3mm thick including cutting for mounting of switches / sockets / suitable for sunken box of sizes 10"x12",inclusing cutting for fixing switches and sockets
Supply and fix in repair pressed steel sunk box 3mm thick including cutting of walls and making the surface good matching the existing sizes 4"x4" . complete all as sspecified and directed
Supply and fix in repair pressed steel sunk box 3mm thick including cutting of walls and making the surface good matching the existing sizes 8"x10" . complete all as sspecified and directed
Supply and fix in repair pressed steel sunk box 3mm thick including cutting of walls and making the surface good matching the existing sizes 10"x12". complete all as sspecified and directed
Supply and fix in repairs PVC connection pipe of 12 mm ((internal) suitable for hot/cold water, 45 cm long with brass nuts and rubber washers complete all as specified and directed
Supply and fix in repairs hole fastner madeup of MS 10mm dia standard length with nut bolt complete all as specified and directed
Supply and fix in repairs heating element of 1.5/2 KW any type with nut bolt washer complete as per site requirement all as specified
Supply and fix in repairs thermostat for 6"/11" suitable for geysers of capacity 15/25/50 Ltrs complete all as specified and directed
Supply and fix in repairs step type modular electronic fan regulator flush type 2 module for 1200 / 1400 mm sweep ceiling fan including taking down existing regulator. Make: Matching to existing location.
Supply and fix in repairs Ceiling fan regulator electronic step switch type/socket type (as directed by Enginneer in charge), suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as specified and directed.
Supply and fixing in repairs hole fastner madeup of MS 10mm dia standard length with nut bolt, hook for hanging Ceiling Fans complete all as specified and directed.
Taking down ceiling fan form site and hand over to JE E/M for deposit to AGE E/M yard for repair /servicing / rewinding etc complete all as directed at site.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as sspecified and directed
M&L Servicing of Ceiling fan of any make and sweep up to 1200 mm from its installed location cleaning, greasing,oiling,painting with two coat of existing colour,nut and boults, etc. . complete all as sspecified and directed
M&L for Rewinding u/s ceiling fan 1200mm and opening the body cover of c/fan, exhaust fan, any type , any make and cutting the existing winding without damaging the stator removing the coil insulation and rewinding with new wire of suitable gauge with correct number of turns of auxiliary and main winding, varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076, including changing/ servicing of bushes etc, testing, refixing and commissioning complete including transportation from area of AGE E/M II .
Supply and fix in repairs capacitor of capacity 2.5mfd-4mfd, 230 V for ceiling fan/exhaust fan including removing old one complete all as specified and directed .
Supply and fix in repairs rubber reel with MS nut Bolt,split/quarter pin for hanging ceiling fan suitable for C/fan complete all as specified and directed .
Supply and Fix in repair Fan motor Complete suitable for 1200mm sweep ceiling Fan Make : Matching the existing site
Supply and fix in repair Fan Blade suitable for 1200 mm Sweep ceiling Fan Make : Matching the existing site
Supply and fix in repair Ceiling Fan Down rod suitable for 1200 mm Sweep ceiling Fan( length 2-3 feet as required)
Supply and Fix in repair Exhaust Fan(Plastic) Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan matching to existing location.
Supply and Fix in repair Exhaust Fan (Metal) Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan matching to existing location.
Supply and Fix in repair Exhaust Fan (Plastic) motor complete suitable any make and sweep 200mm to 300 mm Sweep exhasut Fan matching to existing location. Make : Matching the Existing Site
Supply and Fix in repair Exhaust Fan (Metal) motor complete suitable any make and sweep 200mm to 300 mm Sweep exhasut Fan matching to existing location. Make : Matching the Existing Site
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
8695TenderDocumentsDAY2DAYtrishulEMii3rdCall.pdf
Tender Documents • 0.75 MB
BOQ_844460.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid