Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.3 LAccepted-AOC | 1 | Accepted-AOC Bidder has been financial qualified |
Tender Value
Refer Docs
EMD Value
₹34,639
Closing Date
14 Jul 2020, 5:00 pmClosed
EE WSSD Faridkot
EE WSSD Faridkot, Near City Kotwali, Railway Station Road, Faridkot
Providing improved access to water through household connections in existing water supply scheme Gumti Khurd Block Kotkapura Distt. Faridkot
2020_WB_48960_1
Gumti Khurd
Open Tender
Civil Works - Water Works
Item Rate
90 days
Gumti Khurd
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
TIA
₹34,639
Yes
7 Jun 2021
23 Jun 2020
15 Jul 2020
23 Jun 2020
14 Jul 2020
23 Jun 2020
Amount
5.2 (i)/Carriage of Material Jallabad Sand Lead upto 80 km 6km to 40 km
41km to 60 km
61km to 80 km
5.2 (i)/Carriage of Material Pathankot Sand Lead upto 240 km 6km to 40 km
41km to 60 km
61km to 80 km
151km to 240 km
5.2+4.1/Carriage of Earth including loading for earth filling under lining Lead upto 1.00 km
Compaction:- (i)/Extra for laying earth/fly ash as per specifications for compaction in 20 cm layers and dressing but excluding cost of rolling.
(ii)/Extra for watering the earth/fly ash laid in 20 cm layers as per specifications for compaction.
8.5(b)/Dismantling brick work tile mesonary or tile lining
8.6(d)/Dismantling concrete or precast concrete.
8.6(e)/Dismantling concrete or precast concrete.
8.31(c)/Scraping cement plaster
9.8/Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
10.10(b)/Cement Concrete 1:4:8 with stone ballast of size 40mm gauge using concrete mixer volumatric type.
10.12/Cement Concrete 1:2:4 with stone ballast or shingle.
10.15/Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS 1791 & vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
11.5/First class burnt brick work laid in cement sand mortor 1:5 in foundation and plinth
13.74/Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item)
15.7+15.48/12.5mm thick cement plaster in 1:2 with rendering 1mm thick
15.65/Striking joints in lime or cement on brick walls
15.67/Cement pointing 1:2 flush on flat brick flooring
16.8/Distempering with dry distemper (of approved quality) 2 coats over 1 priming coat
16.14/Finishing walls with exterior decorative cement based paints such as snowcem, Robbiacem etc. on new work two coats to give an even shade.
18.1(c)/Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position :- Tees, angles and channels.
18.18/Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.
19.16/Extra allowance for scaffolding in tile, brick and concrete lining for side slopes only.
28.2+28.13B+28.18/Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including specials, excavation by mechanical means and refilling in origional condition. PVC 6kg/Cm2 (more than 3 mtr street width). (xiii)/63mm o/d P.V.C. pipe 6Kg/Cm2
(xiv)/90mm o/d P.V.C. pipe 6Kg/Cm2
28.27(A)/Providing & fixing CI/DI Flenged End stem of SS (AIS:1410) and bronze (gun metal) working parts sluice valves ISI marked 14846-2000 including jointing, testing and cost of nut bolts and insertion sheet, all carriage complete (with the approval of Engineer-in-Charge) (a)/80 mm i/d sluice valve flanged
(c)/150 mm i/d sluice valve flanged
28.31/Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. A(d)/150mm i/d Non-return valve
28.36/Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (e)/40mm i/d (for Charging Line)
28.51(a)/Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below.
28.66/Construction of masonary Sluice Valve Chamber excluding sluice valve cover as per standard design and drawing of Public Health Department. (a)/Size 0.60 m x 0.60 m
(b)/Size 0.90 m x 0.90 m
28.90/Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
29.26/First class flat brick paving or flooring laid over and in cement sand mortar 1:5
33.14/COPPER EARTHING :- A(i)/Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with 20mm x 3mm thick electrolytic copper tape revitted (with 10 Nos. copper rivets) to 30cm x 120cm x 3mm thick tinned copper plate burried 4 meter below ground level in the hole of excavation having bore dia etc complete in all respect.
NS/Taking out filter media 1st to 5th layer & plasing the same into filter beds ofter washing, screaning & cleaning complete in all respect. Top Layer
2nd to Bottom Layer
NS/Supplying and fixing 200 mm i/d Galvanized iron sheet floating arm of 3mtr. With sluice valve.
NS/Supplying and fixing 150 mm i/d Galvanized iron sheet floating arm of 5.20 mtr. Long with sluice valve complete.
NS/Providing and placing black L.D.P.E. film 200µ thick (confirming to B.I.S. 2508/1984 revised up to date amendments) on side slopes and in bed including sealing overlaps as per industrial best practice (keeping minimum overlap 45cm wide)
NS/Repair of Expantion Joints
NS/Providing and fixing Aluminium Ledder (inside)
NS/Providing & fixing Shunt capastor for control panal
NS/Providing & fixing Control Switch, ampier meter for control panal
NS/Repair of Starter
NS/Providing & Fixing cutout for control panal
NS/Repair of Panal Board and Door etc.
NS/Barbed wire fencing including Strengthening.
NS/Labour for cutting 41 Nos. angle iron and making holes in angle iron including painting.
NS/Repair of Sand Washing Plateform
NS/Providing, fixing & jointing water connection in MDPE pipe (inside ground) and G.I. pipe (outsaide Ground) line 15mm i/d including cutting and threading pipe and making long screw etc. complete including cost of Orifice Type Innovative GI Union, PVC/Metalled 15mm i/d Tap, Nipple, Elbow, clump etc. complete in all respect. (On New Pipe Line)
NS/Providing, fixing & jointing water connection in MDPE pipe (inside ground) and G.I. pipe (outsaide Ground) line 15mm i/d including cutting and threading pipe and making long screw etc. complete including cost of Orifice Type Innovative GI Union, PVC/Metalled 15mm i/d Tap, Nipple, Elbow, clump etc. complete in all respect. (On Existing Pipe Line)
NS/Providing, fixing & jointing Orifice Type Innovative GI Union complete in all respect. (On Existing Water Connections)
NS/Painting on Sign Board.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .